PCU Addition in BSC For Internal use only
Page 1
METHOD OF
PROCEDURE
PCU ADDITION IN BSC
Nokia Siemens Networks Pvt Ltd.
MS India Process & Quality Team
PCU Addition in BSC For Internal use only
Page 2
Document History
Document Author N V Ajay Prabhu
Specialist - Fault Management
Document Contributor(s)
Soney M G Manager - BSS O&M
Document Approver Vipindas Regional BSS Manager-South
Document Release Authority Lalit Sharma National BSS-Head [email protected]
Versions
Date Name Version Platform Contents of change
27/09/2011 N V Ajay Prabhu V1.0 Vendor platform: Nokia DX 200 BSC
Initial Document
PCU Addition in BSC For Internal use only
Page 3
Table of contents 1. Purpose and Scope of Document ................................................................................................. 42. Prerequisite .................................................................................................................................. 43. Compatibility / Dependencies to other products/system/owner ..................................................... 44. Acronym Glossary ........................................................................................................................ 45. Assumptions & Out of Scope details ............................................................................................ 46. Relations with other work instructionns ........................................................................................ 47. Detailed description ...................................................................................................................... 5
7.1 Detailed job description .......................................................................................................... 57.2 Tools Used. ........................................................................................................................... 57.3 Impact on Service .................................................................................................................. 57.4 Identification of the Stakeholders ........................................................................................... 67.5 Specific Instructions ( Entry / Exit Criteria) ............................................................................. 67.6 Software backup and change control requirements ............................................................... 67.7 Pre-Test Plan and expected results ....................................................................................... 67.8 Detailed step-by-step procedures .......................................................................................... 77.9 Post-Test Plan and expected results .................................................................................... 157.10 Roll back Plan .................................................................................................................. 157.11 Emergency Contact Details .............................................................................................. 167.12 Additional Document Reference ....................................................................................... 16
Appendix ............................................................................................................................................ 16
PCU Addition in BSC For Internal use only
Page 4
1. Purpose and Scope of Document
This technical document covers the activity of PCU ADDITION in BSC. The purpose of this document is to describe the actions needed for PCU ADDITION definition in BSC. This document is intended for the use of Managed services professional only for the purpose of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted without the prior permission of Nokia Siemens Networks.
2. Prerequisite
• Engineer should have detailed knowledge about the architecture, Fault Management, Configuration & Integration of Nokia BSC.
3. Compatibility / Dependencies to other products/system/owner
NA
4. Acronym Glossary
Table 4.1 Acronym and Glossary S.No: Key Word Definition
1. BTS Base Transeiver Station
2. BCF Base Control Function
3. PCU Packet Control Unit
4. BSC Base Station Controller
5. Assumptions & Out of Scope details
• NONE
PCU Addition in BSC For Internal use only
Page 5
6. Relations with other work instructions
None
7. Detailed description 7.1 Detailed job description
PCU Addition in BSC
7.2 Tools Used.
(Vendor Platform, Software version, Application Details)
7.3 Impact on Service
• NONE
• Tools Used: Reflection
• Vendor platform: Nokia DX 200 BSC
PCU Addition in BSC For Internal use only
Page 6
7.4 Identification of the Stakeholders
7.5 Specific Instructions (Entry / Exit Criteria)
7.6 Software backup and change control requirements
7.7 Pre-Test Plan and expected results
NA
• NA
• Check the correct username and password of given BSC • Check the user rights of particular user name • Post check should be done befote exit
• GNSC-CM team • RF team
PCU Addition in BSC For Internal use only
Page 7
7.8 Detailed step-by-step procedures
• Open Reflection • Log into the specified BSC
ZQNI;
• Make the BCSU 0 to Spare mode ZUSC:BCSU,0:SP;
• Create the PCU in BCSU //BCSU_0// PCU2_D IN 7th
ZWTP:BCSU,0:PCU2_D,5,7::PCUDSP,4,134,TSL,0&&31:PCUDSP,4,135,TSL,0&&31:PCUPPC,4,141,TSL,0&&31;
Slot
ZWTP:BCSU,0:PCU2_D,6,7::PCUDSP,4,132,TSL,0&&31:PCUDSP,4,133,TSL,0&&31:PCUPPC,4,140,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,0:PCU2_D,5; ZWUC:BCSU,0:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,0:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,0:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,0:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,0:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 0 to test mode ZUSC:BCSU,0:TE;
• Run diagnostics of the Unit ZUDU:BCSU,0;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 1 to Spare mode ZUSC:BCSU,1:SP;
• Create the PCU in BCSU // BCSU_1// PCU2_D IN 7th Slot
PCU Addition in BSC For Internal use only
Page 8
ZWTP:BCSU,1:PCU2_D,5,7::PCUDSP,4,150,TSL,0&&31:PCUDSP,4,151,TSL,0&&31:PCUPPC,4,157,TSL,0&&31; ZWTP:BCSU,1:PCU2_D,6,7::PCUDSP,4,148,TSL,0&&31:PCUDSP,4,149,TSL,0&&31:PCUPPC,4,156,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,1:PCU2_D,5; ZWUC:BCSU,1:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,1:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,1:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,1:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,1:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 1 to test mode ZUSC:BCSU,1:TE;
• Run diagnostics of the Unit ZUDU:BCSU,1;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 2 to Spare mode
ZUSC:BCSU,2:SP;
• Create the PCU in BCSU // BCSU_2// PCU2_D IN 7th
ZWTP:BCSU,2:PCU2_D,5,7::PCUDSP,4,166,TSL,0&&31:PCUDSP,4,167,TSL,0&&31:PCUPPC,4,173,TSL,0&&31;
Slot
ZWTP:BCSU,2:PCU2_D,6,7::PCUDSP,4,164,TSL,0&&31:PCUDSP,4,165,TSL,0&&31:PCUPPC,4,172,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,2:PCU2_D,5; ZWUC:BCSU,2:PCU2_D,6;
PCU Addition in BSC For Internal use only
Page 9
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,2:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,2:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,2:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,2:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 2 to test mode ZUSC:BCSU,2:TE;
• Run diagnostics of the Unit ZUDU:BCSU,2;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 3 to Spare mode ZUSC:BCSU,3:SP;
• Create the PCU in BCSU // BCSU_3// PCU2_D IN 7th
Slot ZWTP:BCSU,3:PCU2_D,5,7::PCUDSP,4,182,TSL,0&&31:PCUDSP,4,183,TSL,0&&31:PCUPPC,4,189,TSL,0&&31;
ZWTP:BCSU,3:PCU2_D,6,7::PCUDSP,4,180,TSL,0&&31:PCUDSP,4,181,TSL,0&&31:PCUPPC,4,188,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,3:PCU2_D,5; ZWUC:BCSU,3:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,3:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,3:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,3:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,3:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 3 to test mode ZUSC:BCSU,3:TE;
• Run diagnostics of the Unit ZUDU:BCSU,3;
PCU Addition in BSC For Internal use only
Page 10
• Check the status od the diagnostics
ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 4 to Spare mode ZUSC:BCSU,4:SP;
• Create the PCU in BCSU // BCSU_4// PCU2_D IN 7th
ZWTP:BCSU,4:PCU2_D,5,7::PCUDSP,4,262,TSL,0&&31:PCUDSP,4,263,TSL,0&&31:PCUPPC,4,269,TSL,0&&31;
Slot
ZWTP:BCSU,4:PCU2_D,6,7::PCUDSP,4,260,TSL,0&&31:PCUDSP,4,261,TSL,0&&31:PCUPPC,4,268,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,4:PCU2_D,5; ZWUC:BCSU,4:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,4:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,4:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,4:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,4:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 4 to test mode ZUSC:BCSU,4:TE;
• Run diagnostics of the Unit ZUDU:BCSU,4;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 5 to Spare mode ZUSC:BCSU,5:SP;
• Create the PCU in BCSU
PCU Addition in BSC For Internal use only
Page 11
// BCSU_5// PCU2_D IN 7th
ZWTP:BCSU,5:PCU2_D,5,7::PCUDSP,4,278,TSL,0&&31:PCUDSP,4,279,TSL,0&&31:PCUPPC,4,285,TSL,0&&31;
Slot
ZWTP:BCSU,5:PCU2_D,6,7::PCUDSP,4,276,TSL,0&&31:PCUDSP,4,277,TSL,0&&31:PCUPPC,4,284,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,5:PCU2_D,5; ZWUC:BCSU,5:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,5:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,5:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,5:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,5:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 5 to test mode ZUSC:BCSU,5:TE;
• Run diagnostics of the Unit ZUDU:BCSU,5;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 6 to Spare mode ZUSC:BCSU,6:SP;
• Create the PCU in BCSU // BCSU_6// PCU2_D IN 7th
ZWTP:BCSU,6:PCU2_D,5,7::PCUDSP,4,1078,TSL,0&&31:PCUDSP,4,1079,TSL,0&&31:PCUPPC,4,10 85,TSL,0&&31;
Slot
ZWTP:BCSU,6:PCU2_D,6,7::PCUDSP,4,1076,TSL,0&&31:PCUDSP,4,1077,TSL,0&&31:PCUPPC,4,10 84,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,6:PCU2_D,5; ZWUC:BCSU,6:PCU2_D,6;
PCU Addition in BSC For Internal use only
Page 12
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,6:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,6:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,6:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,6:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 6 to test mode ZUSC:BCSU,6:TE;
• Run diagnostics of the Unit ZUDU:BCSU,6;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 7 to Spare mode ZUSC:BCSU,7:SP;
• Create the PCU in BCSU // BCSU_7// PCU2_D IN 7th
ZWTP:BCSU,7:PCU2_D,5,7::PCUDSP,4,1158,TSL,0&&31:PCUDSP,4,1159,TSL,0&&31:PCUPPC,4,11 65,TSL,0&&31;
Slot
ZWTP:BCSU,7:PCU2_D,6,7::PCUDSP,4,1156,TSL,0&&31:PCUDSP,4,1157,TSL,0&&31:PCUPPC,4,11 64,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,7:PCU2_D,5; ZWUC:BCSU,7:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,7:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,7:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,7:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,7:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 7 to test mode ZUSC:BCSU,7:TE;
• Run diagnostics of the Unit ZUDU:BCSU,7;
PCU Addition in BSC For Internal use only
Page 13
• Check the status od the diagnostics
ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 8 to Spare mode ZUSC:BCSU,8:SP;
• Create the PCU in BCSU // BCSU_8// PCU2_D IN 7th
ZWTP:BCSU,8:PCU2_D,5,7::PCUDSP,4,1174,TSL,0&&31:PCUDSP,4,1175,TSL,0&&31:PCUPPC,4,11 81,TSL,0&&31;
Slot
ZWTP:BCSU,8:PCU2_D,6,7::PCUDSP,4,1172,TSL,0&&31:PCUDSP,4,1173,TSL,0&&31:PCUPPC,4,11 80,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,8:PCU2_D,5; ZWUC:BCSU,8:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,8:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,8:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,8:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,8:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 8 to test mode ZUSC:BCSU,8:TE;
• Run diagnostics of the Unit ZUDU:BCSU,8;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 9 to Spare mode ZUSC:BCSU,9:SP;
PCU Addition in BSC For Internal use only
Page 14
• Create the PCU in BCSU
// BCSU_9// PCU2_D IN 7th
ZWTP:BCSU,9:PCU2_D,5,7::PCUDSP,4,1190,TSL,0&&31:PCUDSP,4,1191,TSL,0&&31:PCUPPC,4,11 97,TSL,0&&31;
Slot
ZWTP:BCSU,9:PCU2_D,6,7::PCUDSP,4,1188,TSL,0&&31:PCUDSP,4,1189,TSL,0&&31:PCUPPC,4,11 96,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,9:PCU2_D,5; ZWUC:BCSU,9:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,9:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,9:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,9:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,9:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 9 to test mode ZUSC:BCSU,9:TE;
• Run diagnostics of the Unit ZUDU:BCSU,9;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 10 to Spare mode ZUSC:BCSU,10:SP;
• Create the PCU in BCSU // BCSU_10// PCU2_D IN 7th
ZWTP:BCSU,10:PCU2_D,5,7::PCUDSP,4,1206,TSL,0&&31:PCUDSP,4,1207,TSL,0&&31:PCUPPC,4,1 213,TSL,0&&31;
Slot
ZWTP:BCSU,10:PCU2_D,6,7::PCUDSP,4,1204,TSL,0&&31:PCUDSP,4,1205,TSL,0&&31:PCUPPC,4,1 212,TSL,0&&31;
• Connect the PCU with BCSU ZWUC:BCSU,10:PCU2_D,5;
PCU Addition in BSC For Internal use only
Page 15
ZWUC:BCSU,10:PCU2_D,6;
• Configure the new network interface, i.e., to create new PCU2_D ZQRA:BCSU,10:PCU2D,5:IFETH0:1500:UP:; ZQRA:BCSU,10:PCU2D,5:IFETH1:1500:UP:; ZQRA:BCSU,10:PCU2D,6:IFETH0:1500:UP:; ZQRA:BCSU,10:PCU2D,6:IFETH1:1500:UP:;
• Make the BCSU 10 to test mode ZUSC:BCSU,10:TE;
• Run diagnostics of the Unit ZUDU:BCSU,10;
• Check the status od the diagnostics ZUDQ:BCSU,<BCSU no>;
• Check the Result of diagnostics & confirm the unit is OK ZUDH:BCSU,<BCSU no>;
• (Needs to perform the diagnosis of the same BCSU, with both MCMUs. If the diagnosis is
OK, then we will go for next BCSU for PCU addition) then put the BCSU 1 to spare mode.
• Make the BCSU 10 to working mode ZUSC:BCSU,10:WO;
• Finally Give BSC system restart ZUSS::C=DSK;
• Check if any alarms are active or not in BSC. ZAHO ;
7.9 Post-Test Plan and expected results
• Inform to RF Team the PCU added.
7.10 Roll back Plan
• NONE
PCU Addition in BSC For Internal use only
Page 16
7.11 Emergency Contact Details
7.12 Additional Document Reference
Appendix
• NED of BSC
Mandatory Name & Phone No. Contact details,time line Escalation Priority RF Engg SPOC Escalation Matrix Team Lead