Msijute Rfi Survey
Transcript of Msijute Rfi Survey
-
8/10/2019 Msijute Rfi Survey
1/16
Site Name
Site ID
Number of Sectors (Direction)
Site Antenna Band
Coordinates(Decimal)- to show in GPS using a photo
Site Type
Tower Type and Height If Greenfield Site
Building Height if Rooftop
Pole Height if Rooftop
Single Band 900
YES 3
Proposed type (Yes/No), (how many?)
Sector 1
1 -
Sector 1
NO
Sector 1
KATHREIN
Existing Antenna Heights (Count starting from Ground) Sector 1
900MHz Band (Height/m, Azimuth/deg, Quntity of Antennas 40M,0,1
1800MHz Band(Height/m, Azimuth/deg)
2100MHz Band(Height/m, Azimuth/deg)
900MHz & 1800MHz Band
900MHz & 1800MHz &2100MHz Band
Existing Antenna Mechanical & Electric Tilt Sector 1
900MHz Band (M/E) 0/3
1800MHz Band (M/E)
2100MHz Band (M/E)
900MHz & 1800MHz Band (M/E)
900MHz & 1800MHz &2100MHz Band (M/E)
Proposed Antenna Azimuth if too high or has blockage Sector 1
900MHz Band (Height/m, Azimuth/deg)
1800MHz Band(Height/m, Azimuth/deg)
2100MHz Band(Height/m, Azimuth/deg)
900MHz & 1800MHz Band
900MHz & 1800MHz &2100MHz Band
RF-Joint Sit
Existing Antenn Models (See the labels in Antenna )
Greenfield Indoor
Tower Type: 50 M
_______________
_______________
airtel Antennas
Existing type (Yes/No), (how many?)
Existing Quantity of Poles and Free Poles (GSM)
If There is TMA for GSM(YES/NO)
Single Band -YES
Longitude: 40.058
-
8/10/2019 Msijute Rfi Survey
2/16
Proposed Antenna Height (Airtel) Sector 1
900MHz Band (Height/m, Azimuth/deg)
1800MHz Band(Height/m, Azimuth/deg)
2100MHz Band(Height/m, Azimuth/deg)
900MHz & 1800MHz Band
900MHz & 1800MHz &2100MHz Band
Further Details Required Remarks
Space Availability on Tower at required heightRequirement for Poles/Special Brackets/ H-Frames
Poles already available
Space Availability on Tower at required height
Space Availability on Tower at required height if not remarks for solution
Any other specific requirement
1 If there is a blockage. If yes, need to point out which sector
2 If there are free ports in Some Antenna, If yes, need to point out which Antenna & which band as well as which s
3 If any sector with more than one antenna and antennas has different mechanical and electrical tilts and azimuth ,
4 if any ...
Comments If Any
-
8/10/2019 Msijute Rfi Survey
3/16
Single Band 1800 Single Band 2100 Dual band Tri band
Sector 2 Sector 3 Sector 4 (if any) Sector 5 (if any)
1 - 1 -
Sector 2 Sector 3 Sector 4 (if any) Sector 5 (if any)
NO NO
Sector 2 Sector 3 Sector 4 (if any) Sector 5 (if any)
KATHREIN KATHREIN
Sector 2 Sector 3 Sector 4 (if any) Sector 5 (if any)
40M,120,1 40M,240,1
Sector 2 Sector 3 Sector 4 (if any) Sector 5 (if any)
0/3 0/3
Sector 2 Sector 3 Sector 4 Sector 5
e Survey (airtel)
_M
_M
Dual Band
8 Latitude: -10.266590 Elev: 25M
MSIJUTE
TZ1683
3
Triple Band
-
8/10/2019 Msijute Rfi Survey
4/16
Sector 2 Sector 3 Sector 4 Sector 5
Qty.
ctor
need to point out which Antenna &which band as well as which Sector
-
8/10/2019 Msijute Rfi Survey
5/16
-
8/10/2019 Msijute Rfi Survey
6/16
-
8/10/2019 Msijute Rfi Survey
7/16
-
8/10/2019 Msijute Rfi Survey
8/16
BOL/HTT/ Sector-3 22 270 GSM BOL/HTT/ Sector-3
-
8/10/2019 Msijute Rfi Survey
9/16
-
8/10/2019 Msijute Rfi Survey
10/16
-
8/10/2019 Msijute Rfi Survey
11/16
Details Required
Site Name
Site ID
Operator
Cabinet Type (I/D or O/D)
If I/D site than space available for I/D cabinet Installation
If O/D site than requirement for Slab & its Proposal for locationFeeder routing detail (OK or Any requirement) In I/D & O/D both cases
ESB Cable Length required from existing cabinet to new cabinet
Power Cable requirement (Length in meters) for new cabinet
Cable Tray requirement
Ladder Requirements
Grounding Points identifications (For requesting length for Grounding Cable)
Any other specific requirement
Existing Cabinet Detail
Cabinet Type & ID (2K-2106, 2206 or any other) (6K- 6102, 6201, 6101 or 6601)
Modules working in existing cabinets like CDU, DXU, DTRU, RUS, RRUS, RUG
Any other Module
ESB cables or any other spare unit in the existing cabinet
Comments If Any
1 If there is a blockage. If yes, need to point out which sector
2 If there are free ports in Some Antenna, If yes, need to point out which Antenna & which band as well as w
3 If any sector with more than one antenna and antennas has different mechanical and electrical tilts and azi
4 if any ...
E/// BTS TRX Borad Type & Quantity
(DRU / DTRU / RRU / RUG / RUS / other)
Combiner Type & Quantity
(CDU-G / DUG / CDU-F CDU-A/ CDU-C CDU-C+ CDU-D CDU-J CDU-M/ EHCU /Other) ----(Note:most ofthem locate in E/// BTS, some of them is external)
-
8/10/2019 Msijute Rfi Survey
12/16
Remarks QTY. Additional Remarks
MSIJUTE
TZ1683
AIRTEL
O/D
YES SLAB SPACE AVAILABLE, AT THE CENTRE OF TOWER LEGS
10M 1
10M 1
YES
NO
Remarks QTY.
2206V2 1
Template given below
Cell 1 Cell 2 Cell 3 Cell 4
Type: DTRU - G9
Quantiy:2
Type: DTRU - G9
Quantiy:1
Type: DTRU - G9
Quantiy:1
Cell 1 Cell 2 Cell 3 Cell 4
Type: CDU - G9
Quantiy:1
Type: CDU - G9
Quantiy:1
Type: CDU - G9
Quantiy:1
Type: CDU - G18
Quantiy:1
ich sector
uth , need to point out which Antenna &which band as well as which Sector
900MHZ
-
8/10/2019 Msijute Rfi Survey
13/16
Cell 5 Cell 6 Other Cell( if any)
Cell 5 Cell 6 Other Cell( if any)
1800MHZ
-
8/10/2019 Msijute Rfi Survey
14/16
DC Box Location
DC Power Source Generator DC Capacity
Existing CB rating Quantity
Free Circuit
Breakers
Quantity
6A - -
10A - 1
16A 2 0
20A - -
25A - -
32A 4 1
63A - 2
80A - -
100A - -
125A - 2
Other ____A - -
New MCB requirement
Power availability for new Cabinet
Type of Rectifier HUAWEI GRID
Rectifier 1 HUAWEI GRID HYBRID
Rectifier 2 DELTA
Rectifier 3
Rectifier 4
Battery Type
Battery Information
Any other specific information or requirement
NEED ADDITIONAL DC/DC CONVERTERS FROM HUAWEI TO
ACCOMMODATE THE NEW 24V RBS
If yes than Quantity & Rating
Length of Power Cable from DC Box to the new RBS Location 25 M
Capacity:66A Module Quantity: -48 - 5 +24 -
Capacity:________ Module Quantity: 3
Capacity:________ Module Quantity: ____
Capacity:________ Module Quantity: ____
AGISSONCapacity 650AH, 2V Banks 1(24 CELLS)
Indoor/ Outdoor
Mains Batteries266.67A
Existing DC Circuit Breakers and
Rating
Dummy Breakers Quantity -
-
8/10/2019 Msijute Rfi Survey
15/16
Both 24V AND 48V2
-
8/10/2019 Msijute Rfi Survey
16/16
Details Required Remarks Qty.
TN Type or Transmission Type Third Party / Ericsson
E1 Cable length required from TN to New RBS 10M
DDF port availability on TN/TP Equipment AVAILABLE
Any other specific requirement