MSAG3.1 Commission Guide v3.1 GISB(Control Card)

47
  Confidential and Proprietary Informatio n of ZTE CORPORATION  Confidential and Proprietary Information of ZTE CORPORATION  Integrated Access Gateway ZXMSG5200 V3.1 Commissioning Guide Preface Welcome to use MSG5200 equipment. If you have used 5200-V3.1 and previous versions, you have had a full knowledge of our equipment and it may be an easy thing for you to configure th is equipment. You need to read this guide carefully. If you have never used 5200 equipment, this guide provides you a quick understanding of the equipment. V 3.1 Made by liuxin 10125036 Mail:[email protected] Contact:03145111470

description

USERMANUALS OF CARDS EXPLANATION.

Transcript of MSAG3.1 Commission Guide v3.1 GISB(Control Card)

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Integrated Access Gateway

    ZXMSG5200 V3.1 Commissioning Guide

    Preface

    Welcome to use MSG5200 equipment.

    If you have used 5200-V3.1 and previous versions, you have had a full knowledge of our

    equipment and it may be an easy thing for you to configure this equipment. You need to read

    this guide carefully. If you have never used 5200 equipment, this guide provides you a quick

    understanding of the equipment.

    V 3.1 Made by liuxin 10125036

    Mail:[email protected]

    Contact:03145111470

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    contents

    Preface ...................................................................................................................................................... 1

    commission guide ..................................................................................................................................... 3

    1. OverView of MSAG5200 ................................................................................................................ 3

    2. Hardware introduce .......................................................................................................................... 3

    2.1. Card type and service .................................................................................................. 4

    2.2. Hardware connection ................................................................................................... 5

    3. Service Commission introduce......................................................................................................... 7

    3.1. Entering into Data Configuration Interface ................................................................. 8

    3.2. Delete original data ................................................................................................... 10

    3.3. configuring Physical Position .................................................................................... 11

    3.4. Upgradation the version ............................................................................................ 12

    3.5. HSI Service configuration ......................................................................................... 17

    3.6. IPTV Service configuration....................................................................................... 20

    3.7. VOIP service configuration ....................................................................................... 22

    3.8. NMS service configuration ....................................................................................... 25

    3.9. 1+1 uplink protection LACP ............................................................................ 26

    3.10. 1:1 uplink protection UAPS ............................................................................. 27

    3.11. Selfswitch function .................................................................................................... 28

    3.12. EPM configuration .................................................................................................... 29

    3.13. Second dail configuration .......................................................................................... 35

    3.14. DDN service configuration ....................................................................................... 36

    3.15. ISDN-BRI service configuration ............................................................................... 39

    3.16. ISDN PRI CONFIGURATIONS .............................................................................. 40

    3.17. PPPOE+ function ...................................................................................................... 41

    3.18. Function switch ......................................................................................................... 41

    3.19. STAND BY SS CONFIGURATIONS ...................................................................... 43

    3.20. SHDSL configration .................................................................................................. 43

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    commission guide

    1. OverView of MSAG5200

    MSAG is the access equipment of SS (soft switch equipment MGC). MSAG connects with

    SS via H248 protocol (or MGCP). MSAG is made up of control cardmedia resources sub

    card test card and several subscriber cards, converging with a certain amount of

    narrowband analog phone access and broadband ADSL access. The phone services are

    provided by SS and broadband services are provided by internet.

    2. Hardware introduce

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    2.1. Card type and service

    Card name Type Using Shelf/slot---function

    GISB Control and switch card All shelves 9/10 slot;

    GISE/GISB with

    out voip subcard

    Control and switch card Slave shelves 9/10 slot;

    GISE only support Narrow band

    service

    GISB support both Narrow band

    and Broad band services

    VOIP subcard Resource card for

    VOIP ,GISB card

    accessory

    Only install On main shelf GISB

    card

    ODTI Octal digital interface card Main shelf 8,11,12 slot,

    subscriber cable is special,

    for ISDN PRI / DDN/E1 service

    HDB High-speed digital

    subscriber card

    Main shelf 1~8,11~13 slot

    Slave shelves need special version

    for DDN/E1/SHDSL service

    STD HDB card accessory Only install On HDB card

    ALC Analog line card All shelf 1~8,11-15 slot

    for 32 Voip normal user

    RALC Reverse Analog line card All shelf 1~8,11-15 slot

    for 32 Voip Payphone User

    TSLCE Subscriber test card Main shelf 16 slot

    for 112 test

    GELC 32-port integrated voice

    data subscriber card

    GISB shelf 1~8,11~15 slot

    for 32 Voip/ADSL normal user

    GVDL 16-port VDSL subscriber

    card

    GISB shelf 1~8,11~15 slot

    for 16 VDSL normal user

    DLCE ISDN digital subscriber

    card

    all shelves 1~8,11~13 slot

    for ISDN BRI service

    GEI 1000 Mbps Ethernet

    cascade

    interface card

    Main shelf uplink card backplane

    subcard

    for 2GE+2FE uplink

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    SUPI Slave shelf uplink

    interface card

    Slave shelf uplink card backplane

    subcard

    Expansion shelf, for cascading,

    without uplink function

    MBSL Backplane of the

    dual-power rear outlet

    shelf

    Mother board for MSAG

    2.2. Hardware connection

    1) DIP switch(on backplan) :

    MBSL----Master: ON:ON:OFF:OFF(0011)

    MBSL----Slave: ON:ON:OFF: ON(0010)

    Following is Slave shelf dip switch configurations

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    2) Hw connection:

    Master shelf ----Uplink card: GEI

    slave shelf ----Uplink card: SUPI

    X7 and X8 provide two 100 Mbps Ethernet electrical interfaces for

    broadband service uplink.

    X5 and X6 provide two 1000 Mbps Ethernet optial interfaces for

    broadband service uplink.

    X4 is used to connect broadband/narrowband cascade cables,

    which provide 5 4 jack. Leave two rows of pins empty, and

    then plug in the first cascade cable. Plug one cascade cable every

    three rows. Four cascade cables are supported at most to connect

    to four slave shelves

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    3) Fiber connection:

    Fiber need connect with Swith/TXN;

    check GISB BACT light change to green Flashing every half second The broadband

    service is normal.

    Also can using command to check uplink status

    4) Subscriber cable connection:

    Leave the first pin empty plug 3*8 cable connector then after that connector leave one

    another pin plug another 3*8 cable connector, this for 1~16 user

    Leave the last pin empty plug 3*8 cable connector then befor that connector leave

    one another pin plug another 3*8 cable connector,this for 17~32 user

    DSL service checking : GELC card ACT light change to green means DSL link up

    VOIP service checking: ALC/RALC card hook light change to green means phone hook

    up

    Also can using command to check status

    3. Service Commission introduce

    Topology for commission

    X4 is used for cascading. The cascade cables provide 5 4 jack.

    Leave the first two rows of pins empty. The third, fourth, fifth, and

    sixth rows are used for FE broadband/narrowband uplink.

    The ninth, tenth, eleventh, and twelfth rows are used for GE broadband/

    narrowband uplink.

    X1, X2, and X3 are only used to connect the backplanes

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Laptop

    Cross cable

    Console cable

    Laptop

    Console cable

    Cross cable

    Infront of MSAG MSAG MBSL board

    GISB card

    Preparing test equipment for commission

    1) 2 Laptop (wftp;wireshark; Procomm Plus;VLC)

    2) 1 ADSL 4 lan port modem;

    3) Stubbox &TV;

    4) Numbers of cross cables&console cables

    5) Usb to s323 convertor for laptop

    3.1. Entering into Data Configuration Interface

    Console service: provide operationmaintenancedebuggingboot mode

    Outband service: provide operation ,maintenance port ;connect GISB ethnet port

    Inband service: provide operation,maintenance,service port;connect GEI uplink port

    Diagram for configuration interface:

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Laptop

    Console cable

    Cross cable

    MSAG MBSL board

    GISB card

    Network cable

    1) Power on the master shelf of the cabinet, and the two GISB are in positions. Make the

    GISB in Slot 9 as the active card. All the data configurations below are based on the

    situation where the Slot 9 is active. we recommend you set Slot 9 as active.

    2) Enter the user name and password in serial port ;serial configure baud rate is 9600

    Configure your laptop ip using 144.1.1.0/24 then telnet 144.1.1.1 using outband service

    user name/passwordzte/zte

    3) Enter into the data configuration interface ;

    five mode:

    ZXAN #; ZXAN (config)#; ZXAN (config-msag)#; ZXAN (version)#; ZXANconfig-if)#

    See as below

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Specifications on Data Configuration Interface

    Interface Function Transfer

    SHELL Debugging output exit

    ZXAN # Commands of show types can be

    used.

    configure terminal transfer to ZXAN (config)#

    Version transfer to ZXANversion)#

    ZXAN (config)# Hardware and broadband data

    configuration interface

    ZXAN transfer to ZXAN (config-MSAG)#;

    Interface x/x transfer to ZXAN (config-if)#

    ZXAN (config-msag)# Narrowband data configuration

    interface

    exit transfer to ZXAN#;

    ZXAN (version)# Version configuration interface exit transfer to ZXAN#

    ZXAN (config-if)# Sub interface configuration exit transfer to (config)#

    3.2. Delete original data

    Numbe

    r

    Step Function

    1 ZXAN #cd cfg Go to cfg folder

    /cfg

    2 ZXAN #dir Check all the folder

    3 ZXAN#del startrun.dat delete broadband data

    4 ZXAN #cd / exit cfg folder,go to root folder

    5 ZXAN # cd data Go to data folder

    /data

    6 ZXAN #cd v0100 Go to V0100 folder

    /data/v0100

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    7 ZXAN #del *.zdb delete narrowband data in v0100 folder

    8 ZXAN #cd / Exit folder ,Go to root folder

    9 ZXAN #cd data

    Go to data folder

    /data

    10 ZXAN #cd v0101

    Go to V0101 folder

    /data/v0101

    11 ZXAN #del *.zdb

    delete narrowband data in v0101 folder

    12 ZXAN (config) #reboot

    Reboot system

    Notes: all data running on flash, after reboot will reload save data; never do wr after you delete data

    3.3. configuring Physical Position

    Numbe

    r

    Step Function

    1 ZXAN (config) #add-rack rackno 1 racktype MSAG Add Rack

    2 ZXAN (config) #add-shelf rackno 1 shelfno 1 shelftype

    CTL_SHELF

    Add Master Shelf

    3 ZXAN (config) #add-shelf rackno 1 shelfno 2 shelftype

    SLAVE_SHELF connectid 1

    ZXAN (config) #add-shelf rackno 1 shelfno 3 shelftype

    SLAVE_SHELF connectid 2

    Add Slave shelf

    HW Connectid start from 1;

    Shelf range (2-5);Connectid range

    (1-4)

    4 ZXAN (config) #add-card rackno 1 shelfno 1 slotno 3 ALC

    ZXAN (config) #add-card rackno 1 shelfno 1 slotno 4 GELC

    Add user board for each service

    card for Master shelf

    (ALC/RALC/DLCE/ODTI/HDB/G

    ELC/GVDL)

    Add user board for each service

    card for Master shelf

    5 ZXAN (config) #add-card rackno 1 shelfno 2 slotno 9 GISB

    ZXAN (config) #add-card rackno 1 shelfno 3 slotno 3 GELC

    Add slave shelf Main control card

    GISE/GISB

    Add slave shelf user board for each

    service card

    (ALC/RALC/DLCE/ODTI/HDB/G

    ELC/GVDL)

    6 ZXAN (config) #show card Can check all card

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    7 ZXAN(config)#del-subcard slotno 9 subcardno 2

    default value NO.2 subcard is

    CNIC/MAPP,you need delete

    this,add voip card to NO.2

    8 ZXAN(config)#add-subcard slotno 9 subcardno 2 VOIP default value NO.2 subcard is

    CNIC/MAPP,you need delete

    this,add voip card to NO.2

    9 ZXAN(config)#show subcard Check subcard 2voip online

    10 ZXAN#write Save data

    Notes: Only after config rack system can start update version;uplink card GEI will be auto add by MSAG

    3.4. Upgradation the version

    1 Diagram for HSI configuration and troubleshooting

    Ethernet cable

    Ip add:144.1.1.100

    Submask:255.255.255.0

    Defult outband ip add:144.1.1.1

    Submask:255.255.255.0

    2 System FTP configuration

    Number Step Function

    1 ZXAN#config terminal Shift to config mode

    2 ZXAN(config)#show interface mng1 Display outband ip and ftp

    configration

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    3 ZXAN(config)#interface mng1

    ZXAN(config-if)#boot-server 144.1.1.100

    ZXAN(config-if)#boot-username target

    ZXAN(config-if)#boot-password target

    Shift to management interface;

    Both FTP username & Password

    must be same at both MSAG &

    FTP software

    modify ftp server ip address;

    modify ftp server username;

    modify ftp server password;

    4 ZXAN(config-if)#ex

    ZXAN(config)#ex

    ZXAN#wri

    Quit mng1 interface

    Quit config mode

    Save config data

    3 ftp server config

    Run this ftp server software,you can see this windows as below:

    Click security menu,choice users/rights

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Click

    Enter username uni,click OK

    Enter password uni,click OK

    Enter version file directory like as E:\version

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Click Done,then minimum software window.

    4 Update progress

    Download version file to memery

    Number Step Function

    1 ZXAN#version Shift to config mode

    2 ZXAN(version)#download version ics.bt

    ZXAN(version)#download version ics.fw

    ZXAN(version)#download version ics.mvr

    ZXAN(version)#download version voip_normal.fw

    Download GISB boot/version

    3 ZXAN(version)#download version gise.bt

    ZXAN(version)#download version gise.mvr

    Download GISE boot/version

    4 ZXAN(version)#download version gelca.bt

    ZXAN(version)#download version gelca.mvr

    Download gelca boot/version

    5 ZXAN(version)#download version gdl.bt

    ZXAN(version)#download version gvdld.fw

    ZXAN(version)#download version gvdld.mvr

    Download gvdld boot/version

    6 ZXAN(version)#download version dti.bt

    ZXAN(version)#download version dti.mvr

    Download odti boot/version

    7 ZXAN(version)#download version dlce.mvr

    ZXAN(version)#download version tslce.mvr

    Download dlce/tslceversion

    Tslc use GDL.BT as its boot

    version

    NotesALC/HDB no need version

    update boot one-by-one slot for sevice card(except control card)

    Number Step Function

    1 ZXAN#version Shift to config mode

    2 ZXAN(version)#update-boot shelfno 1 slotno 3 local

    ZXAN(version)#show update-status shelfno 1

    Update boot for shelfno 1 slotno 3

    Display update status,you can see

    success or same versions

    3 ZXAN(version)#update-boot shelfno 1 slotno 4 local

    ZXAN(version)#show update-status shelfno 1

    Update boot for shelfno 1 slotno 4

    Display update status,you can see

    success or same version

    4 Same for all the service cards for all the shelves . Update boot is slot by slot .

    5 ZXAN(version)#update-boot shelfno 2 slotno 3 local

    ZXAN(version)#show update-status shelfno 2

    Update boot for shelfno 2 slotno 3

    Display update status,you can see

    success or same versions

    6 ZXAN(version)#update-boot shelfno 3 slotno 3 local

    ZXAN(version)#show update-status shelfno 3

    Update boot for shelfno 3 slotno 3

    Display update status,you can see

    success or same versions

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    NotesALC/HDB no need version,this document only give the sample ,all configuration follow actually

    situation

    update version batch every shelf

    Number Step Function

    1 ZXAN#version Shift to config mode

    2 ZXAN(version)#update-version shelfno 1 local

    ZXAN(version)#show update-status shelfno 1

    Update version batch for shelfno 1

    Display update status, you can see sucess

    3 ZXAN(version)#update-version shelfno 2 local

    ZXAN(version)#show update-status shelfno 2

    Update version batch for shelfno 2

    Display update status, you can see sucess

    4 ZXAN(version)#update-version shelfno 3 local

    ZXAN(version)#show update-status shelfno 3

    Update version batch for shelfno 3

    Display update status, you can see sucess

    NotesAll configuration follow actually situation

    update boot for main control card every shelf

    Number Step Function

    1 ZXAN#version Shift to config mode

    2 ZXAN(version)#update boot shelfno 1 slotno 9 local Update version batch for shelfno 1

    Display update status, you can see sucess

    3 ZXAN(version)#update boot shelfno 2 slotno 9 local Update version batch for shelfno 2

    Display update status, you can see sucess

    4 ZXAN(version)#update boot shelfno 3slotno 9 local Update version batch for shelfno 3

    Display update status, you can see sucess

    NotesAll configuration follow actually situation

    Update version for slave control card every shelf

    Number Step Function

    1 ZXAN#version Shift to config mode

    2 ZXAN(version)#main-backup version

    synchronization shelfno 1

    ZXAN(version)#show sync-status shelfno 1

    Synchronization shelfno 1

    Display syn status

    3 ZXAN(version)#main-backup version

    synchronization shelfno 2

    ZXAN(version)#show sync-status shelfno 2

    Synchronization shelfno 2

    Display syn status

    4 ZXAN(version)#main-backup version

    synchronization shelfno 3

    ZXAN(version)#show sync-status shelfno 3

    Synchronization shelfno 3

    Display syn status

    NotesAll configuration follow actually situation

    Check version every shelf

    Number Step Function

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    1 ZXAN(version)#exit Shift to config mode

    2 ZXAN#show card Display Card status

    3 ZXAN#show version-running shelfno 1

    ZXAN#show version-running shelfno 2

    ZXAN#show version-running shelfno 3

    Display old version,active version,

    This version store in flash

    4 ZXAN#show version-saved shelfno 1

    ZXAN#show version-saved shelfno 2

    ZXAN#show version-saved shelfno 3

    Display new version,inactive version

    This version store in memory

    NotesAll configuration follow actually situation

    Reboot shelf start from slave shelf

    Number Step Function

    1 ZXAN#reboot shelfno 4

    ZXAN#show card shelfno 4

    After reboot ,check all cards status for

    shelf 4

    2 ZXAN#reboot shelfno 3

    ZXAN#show card shelfno 3

    After reboot ,check all cards status for

    shelf 3

    3 ZXAN#reboot shelfno 2

    ZXAN#show card shelfno 2

    After reboot ,check all cards status for

    shelf 2

    4 ZXAN#reboot shelfno 1

    ZXAN#show card

    Master shelf reboot ,need wait same time

    before all shelf running

    NotesAll configuration follow actually situation

    5 Simple trouble shooting

    All Card not get up ,change the slot

    Shelf not get up ,check DIP switch & HW cable connection

    3.5. HSI Service configuration

    1) Diagram for HSI configuration and toubleshooting

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Configure the Modem in

    Bridge mode

    Make a dialer in user

    laptop and dial.

    Soft Bras

    Connect the laptop on

    Spare FE Uplink port

    Configure HSI VLAN untag

    the Spare Uplink

    Subscriber cable

    TRX Equipment

    Bras

    2) Preparing for starting configure HSI

    equipment preparing

    1 Laptopsoftwarewiresharksoftbras

    2 4 port ADSL modem

    3 Number of Network cables

    4 Number of subscriber cables

    Data preparing:

    1) HSI vlan

    2) PPPOE username & password

    3) HSI configuration step

    1) Create vlan

    2) User port untag to this vlanuplink port tag to this vlan

    3) Change PVC value same to modemenable PVC 1

    4) Change ADSL profile

    Numbe

    r

    Step Function

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    1 ZXAN (config)#vlan 402

    ZXAN(config)#vlan database

    ZXAN(vlan)#vlan 101,201,301,3999,401

    Create vlan 402 (for create one by one)

    Create vlan database (for create multi vlan

    together)

    2 ZXAN (config) #interface adsl_1/4/1-32

    ZXAN (config-if-range) #no shutdown

    ZXAN(config-if-range) #switchport default vlan

    101 pvc 1

    Configure the port transfer sub-interface using

    range

    Open this interface

    Add first PVC 1 untag to Vlan 101,

    when type default vlan means pvid same to vid

    3 ZXAN (config-if-range) #atm pvc 1 vpi 8 vci 81

    ZXAN (config-if-range) # PVC 1 enable

    Change the first PVC 1 ; VPI&VCI need same to

    modem;

    Enable the first PVC

    4 ZXAN(config-if-range)#adsl profile def2m.prf

    Apply adsl profile for link up rate

    ADSL2+ can reach 24 M download speed

    ADSL2+ can reach 1 M upload speed

    5 ZXAN(config)#adsl profile xyz

    Creat and modify new adsl profile;profile name is

    xyz

    6 ZXAN(config)#interface gei_1/9/3

    ZXAN(config-if)#switchport vlan

    101,201,301,3999,401 tag

    ZXAN(config-if)#no shutdown

    Configure the uplink

    Tag uplink to vlan 101,201,301,399,401

    Enable uplink port

    7 ZXAN#show vlan 402

    Check the vlan information include tag port &

    untag port

    8 ZXAN#show adsl port-info adsl_1/3/1

    Check dsl service link up rate

    9 ZXAN#show dsl interface adsl_1/3/1 pvc 1 Check port pvc status

    10 ZXAN#show adsl port-config adsl_1/3/1

    Check line profile for this adsl port

    11 ZXAN#show runing Check all the configuration

    12 ZXAN#write Save the data

    Notes: all data configure need check again,show running will be more easy to check all the configuration

    If configure 1+1 uplink using sgsmartgroup

    4) Simple trouble shooting

    1) Using one laptop to dialing ,another laptop connected spare FE port,configure

    uplink to untag to HIS vlan first ;then using monitor session to capture the PPPOE

    packet

    2) Using one laptop to dialing, another laptop using softbras to simulate Bras,to check

    this vlan is ok or not

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Authentication failure testing method at MSAN.doc

    software BRAS setting.doc

    3.6. IPTV Service configuration

    1 Diagram for IPTV configuration and troubleshooting

    Uplink network

    modem

    televisionSTB

    subscribercable

    LAN cable

    Audio/video cable

    Fiber cable

    Configure the Modem in Bridge mode

    PVC same as MSAG

    2 Preparing for starting configure IPTV

    IPTV include two partlive channel&VOD

    live channel: using multicast packet, protocol using IGMP;

    function is see the live channel together

    VOD : using unicast packet,protocol ;also using for stubbox authentication PPPOE

    protocol

    Function is register to Bras and also can see the movie

    equipment preparing

    1 Laptopsoftwarewiresharksoftbrasvlc

    2 4 port ADSL modem

    3 Number of Network cables

    4 Number of subscriber cables

    5 Stubbox & TV

    Data preparing:

    Live channel

    1) Mvlan using 3999

    2) Channel group

    VOD

    1) PPPOE username & password for VODneed provide by PTCL

    2) VOD vlan

    3 IGMP configuration step

    Live channel

    1) Create vlan

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    2) Make the MVlan

    3) Enable IGMP

    4) Change IGMP mode to proxy

    5) Add source port for IGMP

    6) Add receive port for IGMP

    7) Add group for IGMP

    8) Add uplink port tag to MVlan

    9) Mvlan translate VOD vlan to Mvlan

    VOD vlan

    1 Add user port PVC 2 untag to VOD vlan;Add uplink port tag to VOD Vlan

    2 Change PVC 2 value same to modem;enable PVC 2

    3 Add uplink port tag to MVlan

    4 Change ADSL profile

    IGMP configuration

    Number Step Function

    1 ZXAN (config)#vlan 3999

    ZXAN (config) # igmp mvlan 3999

    Create vlan 3999 for MVlan

    Create MVLan

    2 ZXAN (config) #igmp enable Igmp global enable

    3 ZXAN(config) #igmp mvlan 3999 work-mode proxy Igmp work mode snooping/proxy

    4 ZXAN (config) #igmp mvlan 3999 group 239.194.0.1 to

    239.194.0.170

    Set Iptv channel

    5 ZXAN(config)#igmp mvlan 3999 source-port gei_1/9/3 Set iptv source port

    6 ZXAN (config) #igmp mvlan 3999 receive-port

    adsl_1/5/1-32 pvc 2

    Set iptv receive port

    7 ZXAN(config)#interface gei_1/9/3

    ZXAN(config-if)#switchport vlan 3999 tag

    Add uplink to this 3999 Mvlan & VOD

    vlan also

    8 ZXAN (config) #interface adsl_1/5/1-32 Enter ADSL port config mode

    9 ZXAN (config-if-range) #no shutdown Port enable

    10 ZXAN (config-if-range) #switchport mode access Set port mode access/trunk/hybrid

    VOD part

    11 ZXAN (config-if-range) #switchport default vlan 201 pvc

    2

    Add vlan to PVC2,PVID is 201

    VOD part

    12 ZXAN (config-if-range) #atm pvc 2 vpi 0 vci 35 Set pvc 2,VPI/VCI

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    ZXAN (config-if-range) # pvc 2 enable PVC2 enable

    13 ZXAN (config-if-range) #adsl profile def4m.prf Set adsl port profile

    14 ZXAN (config-if-range) # mvlan-translate 3999 to untag

    pvc 2

    Translate municast vlan 3999 to

    ports PVID 201

    Notes: all data configure need check again,show running will be more easy to check all the configuration

    4 Simple trouble shooting

    VOD register failed

    a) If STB fail to connect the server use PPPOE dialing trough computer and verify

    username and password.

    b) If PPPOE dialing fail through computer please verify VOD vlan

    configuration.Using this document

    IPTV troubleshooting.doc

    UNICAST AND MULTICAST TESTING.doc

    3.7. VOIP service configuration

    1) Diagram for IPTV configuration and troubleshooting

    Configure Monitor session

    for uplink ,untag spare unlink

    to capture magaco packet

    Subscriber cable

    TRX Equipment

    Softswitch

    2) Preparing data for starting config VOIP

    Normally using H248 protocol

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    equipment preparing

    1) Phone

    2) Number of Network cables

    3) Number of subscriber cables

    Data preparing:

    1) SS type & IP address

    2) VOIP protocol H248 or MGCPprotocol port 2944 for h248

    3) TID for narrow band user and RTP resource

    4) MSAG VOIP IP address and next hop;NAT protocol

    5) VOIP vlan

    3) VOIP configuration step

    1) VOIP subcard should be ok,first time configure will be take long time 10~15 minuter

    2) Create VOIP vlan and bind vlan

    3) Set Softswitch(MGC) parameter

    4) Create MG bind with MGC

    5) Set MSAG voip ipaddress and set MSAG voip next hop

    6) Set NAT protocol for MSAG

    7) Create VOIP TID on each narrow band cards// HW:A ZTE: USER

    8) Create RTP resource

    9) Add uplink port tag to VOIP vlan

    10) Configure IP on VOIP vlan

    Number Step Function

    1 ZXAN(config)#del-subcard slotno 9 subcardno 2

    ZXAN(config)#add-subcard slotno 9 subcardno 2 VOIP

    ZXAN(config)#show subcard

    Delete default subcard 2

    Add voip card to subcard 2

    Get VOIP subcard status should be OK

    2 ZXAN(config)#vlan 301

    ZXAN(config-vlan)#voip-bind

    ZXAN(config-vlan)#voip-ctrl

    ZXAN(config-vlan)#exit

    Create VOIP vlan

    Bind VOIP media

    Bind VOIP signal

    3 ZXAN#msag

    ZXAN(config-msag)#mgc add 1 10.20.32.5 port 2944

    type 1

    Config softswitch(MGC) parameter

    Type 1 for zte ss

    Type 2 for huawei ss

    4 ZXAN(config-msag)#mg add 1 1 port 2944

    Create MSAG bind with

    Softswitch(MGC)

    5 ZXAN(config-msag)#voip interface add ctrl-ip

    10.63.86.113 ctrl-mask 255.255.255.0 media-ip

    Set MSAG VOIP IPaddress

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    10.63.86.113 media-mask 255.255.255.0 route-mode 2

    ZXAN(config-msag)#voip route add 10.63.86.254

    Set MSAG VOIP next hop

    6 ZXAN(config-msag)#media-nat add 9 1 9 5 5

    10.63.86.113 10000

    Add NAT protocol for RTP translater

    Nat port start from 10000

    7 ZXAN(config-msag)# slc terminationid add rackno 1

    shelfno 1 3 USER type 3 begin-no 0 digit-length 4

    mgid 1

    ZXAN(config-msag)# slc terminationid add rackno 1

    shelfno 1 7 A type 2 begin-no 0

    ZTE Softswitch TID must using

    USER0000~USER00XX..ETC

    HW Softswitch TID must use

    A0~Axxx

    8 ZXAN(config-msag)# rtp terminationid add RTP

    begin-seqno 1 240 type 3

    ZXAN(config-msag)#rtp terminationid add RTP/

    begin-seqno 1 240

    Add RTP resources if ZTE SS must

    start RTP000~RTP0XX

    Add RTP resource if HW ss must start

    RTP/0~RTP/xx

    9 ZXAN(config)#interface gei_1/9/3

    ZXAN(config-if)#switchport vlan 301 tag

    ZXAN(config)#interface vlan 301

    ZXAN(config-if)#ip address 10.63.86.113

    255.255.255.0

    ZXAN(config-if)#exit

    ZXAN(config)# ip route 10.0.0.0 255.0.0.0

    10.63.86.254 (vrrp ip , voip next hope )

    Add uplink port to VOIP vlan

    Configure this IP on this vlan .

    Ping next hope to check your config

    Add route to PING SS ,

    Now Ping SS ip

    ZXAN#show vlan 312

    ZXAN#show msag mgc

    ZXAN#show msag mg

    ZXAN#show msag voip-ipaddr

    ZXAN#show msag allnat

    ZXAN#show msag rtp terminationid

    ZXAN#show msag slc terminationid shelf 1 3

    ZXAN#show msag h248-status

    verify that up link tagged over VOIP

    VLAN.

    verify that SS parameter is

    configured properly or not

    vertify Mg configure properly or

    not

    check MSAG VOIP address and next

    hop

    check NAT parameter

    check RTP

    check TID

    check H248 status

    Notes: all data configure need check again,show running will be more easy to check all the configuration

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    4) Simple trouble shooting

    1) Using wireshark to capture uplink packet to check H248 packet (Megaco),

    monitor session for this spare uplink port

    2) Ping SS IP address ZXAN# ping 10.16.98.102

    3.8. NMS service configuration

    1) Diagram for NMS configuration and troubleshooting

    Uplink network

    LAN cable-outbandSerial cable-console port

    terminal

    Fiber cable

    2) Preparing data for starting config nms

    1) NMS vlan

    2) NMS IPaddress for MSAG

    3) NMS Next hop

    Number Step Function

    1 ZXAN(config)#interface gei_1/9/4 Enter GE port config mode

    2 ZXAN(config-if)#switchport vlan 401 tag Create FE port VID connect uplink port

    3 ZXAN(config-if)#exit Quit to global config mode

    4 ZXAN(config)#interface vlan 401 Enter vlan config mode

    5 ZXAN(config-if)#ip address 10.100.10.10

    255.255.255.0

    Create L3 ip address

    6 ZXAN(config-if)#exit Quit to global config mode

    7 ZXAN(config)#ip route 10.0.0.0 255.0.0.0

    10.100.10.1

    Create ip route information,nexthop and

    network

    8 ZXAN#ping 10.100.10.1 Ping

    Notes:You can ping nexthop ip address

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    ZXAN#ping 10.100.10.1

    sending 5,100-byte ICMP echos to 10.100.10.1,timeout is 2 seconds.

    !!!!!

    Success rate is 100 percent(5/5),round-trip min/avg/max= 0/8/40 ms.

    3) Simple trouble shooting

    1) Using spare FE uplink to connect one laptop ,configure this spare port in NMS vlan

    Configure Laptop ipaddress same to NMS next hop IP

    2) Ping MSAG using laptop

    NMS.doc

    3.9. 1+1 uplink protection LACP

    Using 2 GE uplink to meet load sharing with traffic

    LACP configuration step

    1 Create Smartgroup

    2 2 GE uplink must same using same vlan

    3 Add smartgroup in these vlan same configuration with GE uplink

    Number Step Function

    1 ZXAN(config)#interface smartgroup1

    ZXAN(config-if)#switchport vlan 401 tag

    ZXAN(config-if)exit

    create smartgroup 1

    add this smartgroup to this vlan

    2 ZXAN(config)#interface fei_1/9/3

    ZXAN(config-if)#switchport vlan 401 tag

    ZXAN(config-if)#smartgroup 1 mode active

    ZXAN(config)#interface fei_1/9/4

    ZXAN(config-if)#switchport vlan 401 tag

    ZXAN(config-if)#smartgroup 1 mode active

    Add uplink to this vlan

    Smartgroup mode have three

    Activepassiveon

    LACP using active mode

    Trunk using on mode

    Our suggestion active mode

    3 ZXAN(config)#show lacp internal Check LACP status

    Simple trouble shooting

    ZXAN(config)#show lacp internal

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    Smartgroup:1

    Flag *--LOOP is TRUE

    Actor Agg LACPDUs Port Oper Port RX Mux

    Port State Interval Priority Key State Machine Machine

    -----------------------------------------------------------------------------

    gei_1/9/3 selected 30 32768 0x103 0x3d current distributing

    gei_1/9/4 selected 30 32768 0x103 0x3d current distributing

    if you see two port are all select, means the one plus one function is OK, you can do the

    test!

    3.10. 1:1 uplink protection UAPS

    AG

    Uplink network

    gei_1/9/3 gei_1/9/4

    gei_2/22 gei_2/22

    gei_1/10 gei_1/10

    gei_1/11 gei_1/11

    VLAN plan:

    100 HSI

    200 NMS

    300 VOIP

    IP plan:

    NMS 12.12.12.254/24 nexthop 12.12.12.1/24

    VOIP 10.10.10.254/24 nexthop 10.10.10.3/24

    VRRP ipaddress:10.10.10.3/24

    VLAN 300 interface

    ipaddress:10.10.10.1/24

    VLAN 300 interface

    ipaddress:10.10.10.2/24

    modem

    Number Step Function

    1 ZXAN#configure termianal

    ZXAN(config)#uaps-group 1

    Create uplink protection group

    2 ZXAN(cfg-uaps-1)#port master-port gei_1/9/4

    slave-port gei_1/9/3

    add port to protection group

    (1/9/4 active, 1/9/3 for

    standby)

    3 ZXAN(cfg-uaps-1)#next-hop 10.10.10.3 link-type

    media

    Set up to detect link type

    (media or normal), can examine

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    the next-hop ok or not.

    ZXAN(config)#show uaps

    Group List :

    ---------------------------------------

    Group List :

    ---------------------------------------

    1

    ZXAN(config)#show uaps groupid 1

    Revertive control : disable

    Next-hop : 10.10.10.3

    Link-type : media

    Link-detect-retry : 5

    Link-detect-interval : 3

    Link status : connected or NA

    Bfd next_hop : 0.0.0.0

    Bfd Link status : connected or NA

    Switch-type : common port

    Master ports status : block gei_1/9/3 : up

    Slave ports status : forwarding gei_1/9/4 : up

    3.11. Selfswitch function

    Dont need connect Softswitch can make dail

    Selfswitch configure step

    1) Add-phone number

    2) Add-digitmap

    3) Self-exchange configuration

    Number Step Function

    1 ZXAN (config-msag) #SLC phone-number modify 3

    begin-index 1 num 16 begin-phone-number 88801

    ZXAN (config-msag) #show msag slc phone-number

    ZXAN (config-msag) #SLC phone-number del

    Add selfswitch phone number

    Get result

    Delete selfswitch phone number

    2 ZXAN (config-msag) #digitmap add 1 SELFDM digit-map

    888XX servicetype 1

    Digitmap must follow the number

    Like phone number 8888,so digitmap

    need 8xxx;

    3 ZXAN (config-msag)#MG capability 1 self-exchange 1 Enable self exchange

    ZXAN (config-msag)#mg parameter 1 link-kept-time 10

    ZXAN(config-msag)#show msag mg parameter mgid 1

    Change H248 linkdown time

    Check the result

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    ZXAN (config-msag) #mgc type modify 2 dm-long 15

    ZXAN (config-msag) #mgc type modify 2 dm-start 15

    ZXAN (config-msag) #show msag mgc type mgctype 2

    Change dial tone time

    Check the result

    3.12. EPM configuration

    Creat SNMP TRAP SERVER first use the following command set to set SNMP TRAP

    SERVER

    Zxan(config)#snmp-server host 116.71.241.228 trap

    version 2c public enable NOTIFICATIONS

    server-index 1 udp-port 162

    MSAG SERVER IN H-9

    Zxan(config)#snmp-server host 119.153.44.116 trap

    version 2c public enable NOTIFICATIONS

    server-index 2 udp-port 162

    SNMP TRAP SERVER IN PTCL NOC

    Zxan(config)#snmp-server host 144.1.1.100 trap

    version 2c private enable NOTIFICATIONS

    server-index 3 udp-port 162

    FOR LOCAL CHECK DURING PRE PAT

    Show snmp config

    ZXAN(config)#fan-epm-console epm

    Show fan-epm-console

    1. Create EPM unit on nms

    2. Choose the NE, click create button

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    3. you will see EPM in the bottom of the rack map

    4. config environment sensor

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    5,only need config the sensor 1 , after this , you can test if all the sensor works well

    6,config the power unit

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    7,click create button

    8. COM No usually be 2 , the power type depend on which type of power the site use, then

    create OK

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    9,then at here you will see the temperature , humidity , AC, DC, battery sensor value

    10, you can config the sensors threshold at here

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    11,for test the temperature sensor , you can config the upper value very low

    10. power threshold config , config 52 for battery and DC voltage test

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    11,here to check all the environment and power alarm

    3.13. Second dail configuration

    182_191_255_20(config-msag)#rtp mprb-parameter dtmf dtmfrelaymode 1 choose viice

    coding,

    If you still find issue in dialing phone numbers like 1218, 080080800 , 1217, 131 777 77 then use

    the following commond

    182_191_255_20(config-msag)#rtp mprb-parameter dtmf dtmfrelaymode 6

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    0 NOT RELAY.

    1 VOICE CODING.

    2 Red RFC2833.

    4 AAL2/IETF.

    6 nRed RFC2833.

    3.14. DDN service configuration

    1) Diagram for NMS configuration and troubleshooting

    E1 analysis tester

    E1 cable

    transmision

    Subscriber cable

    V35 cable

    2) Topo Logic

    O H

    D D

    T B

    I

    MODEM SDH

    Network

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    3) equipment preparing

    1 SHDSL (X3208D) modem

    2 Modem interface :V35

    3 Test equipmenterror E1 analysis equipmentACTERNA E1 and Data EDT-135

    4 HDB card hardware jumper wire config X12~X15X1223X1312X1412

    X1512

    5 ODTI card hardware jumper wire config X10-X25:12---75ohm,23---120ohm

    4) DDN service configure step

    1) Configure HDB work mode

    1 port mode i.e 1*n*64k

    32x64k

    1

    32

    1 port mode is using maximum of 2mb circuit, if your using 1 port mode, it uses all timeslot

    for 1 E1 i.e 32 timeslots, the command for configuring 1 port mode is :

    msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_32x64k

    2 port mode i.e 2*n*64k

    16x64k 16x64k

    1 17

    32

    2 port mode is using maximum two 1mb circuits i.e 1mb circuit for first 16 timeslots (1-16 ts),

    and 1mb circuit for other 16 timeslots (17-32 ts),the commands for configuring 2 port mode

    is :

    msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k

    msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_16x64k

    3 port mode i.e 1*n*64k+2*m*64k

    16x64k 8 x64k 8x64k

    1 17 25 32

    3 port mode can using maximum one 1mb circuit and two 512 kbs circuit , using 1-17

    timeslots for 1mb, 17-25 time slots for 512kbs and 25-32 timeslots for other 512kbs,

    commands for configuring 3 mode is :

    msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k

    msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_8x64k

    msag(config-msag) ddn port add hdb 5 25 type type_hdb subratetype subratetype_8x64k

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    4 port mode 4*n*64k

    8x64k 8x64k 8x64k 8x64k

    1 9 17 25 32

    4 port mode is using maximum four 512kbs circuits,i.e using first 1-9 timeslots for 512kbs,

    other 9-17 timeslots 512kbs, other 17-25 for next 512kbs,similarly 25-32 timeslot for last

    512kbs circuit,commands for 4 port mode is:

    msag(config-msag) ddn port add hdb 5 1 type type_hdb subratetype subratetype_16x64k

    msag(config-msag) ddn port add hdb 5 9 type type_hdb subratetype subratetype_8x64k

    msag(config-msag) ddn port add hdb 5 17 type type_hdb subratetype subratetype_8x64k

    msag(config-msag) ddn port add hdb 5 25 type type_hdb subratetype subratetype_8x64k

    2) Create DDN port for HDB

    3) Create DDN port for ODTI

    4) Create DDN connection from HDBODTI

    Number Step Function

    1 ZXAN(config-msag)#ddn hdb portnum modify 3 portnum

    4*n*64K

    Configure HDB work mode

    Notes: it can using 4 ports

    First port is 24A/24Csecond port is

    26A/26Cthird port is 28A/28C

    fourth port is 30A/30C

    2 ZXAN(config-msag)# ddn port add HDB shelf 3 4 1 type

    type_hdb subratetype subtype_3x64k

    Create DDN port for HDB

    3 ZXAN(config-msag)#ddn port add ODTI shelf 1 8 1 type

    type_odti subratetype subtype_3x64k ts 1

    Create DDN port for ODTI

    Notestotal 364Konly can bind 1

    E1 ,start must from ts 1

    4 ZXAN(config-msag)#ddn connection add 1 PortName1 HDB

    PortName2 ODTI DDN--HBL

    Create DDN connection from

    HDBODTI

    Notes:using name to bind each other

    5 ZXAN(config)#set-e1clktype EST2M Set clock source

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    6 ZXAN#show msag ddn connection

    ZXAN#show msag ddn hdb portnum shelf 3 4

    ZXAN#show msag ddn port shelf 1 slot 8

    ZXAN#show msag ddn port shelf 3 slot 4

    ZXAN#show e1clock

    check DDN connect

    check work mode

    check DDN port(ODTI)

    check DDN port(HDB)

    check clock source

    7 ZXAN(config-msag)#pcm attribution modify 8 1

    loop-back 1

    ODTI E1 loop

    5 Simple trouble shooting

    Test way pls check this document

    DDN config manul.doc

    DDN-test.doc

    3.15. ISDN-BRI service configuration

    1) Diagram for NMS configuration and troubleshooting

    Configure Monitor session

    for uplink ,untag spare unlink

    to capture magaco packet

    Subscriber cable

    TRX Equipment

    Softswitch

    NT1

    2) equipment preparing

    1 ISDN NT1

    2 Connect Phone with DLCE card

    ISDN parameter preparing

    1) Desport 6100 ;local port 2905

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    2) Interface ID (IID)

    3) TID for ISDN user

    3) ISDN service configure step

    1) Add AS

    2) Add ASP ,

    3) Bind AS & ASP,

    4) Configure D channel

    5) Add TID for ISDN user

    6) Add SCTP signal port

    Notes:before configure ensure H248 is OK;check licence.dat

    Number Step Function

    1 ZXAN(config-msag)#as add 1

    ZXAN(config-msag)#asp add 1 6100 2905 1 10.16.98.102

    instream 8 outstream 8

    ZXAN(config-msag)#asasp add 1 1

    ZXAN(config-msag)#show msag as

    ZXAN(config-msag)#show msag asp

    Add AS ;

    Add ASP set parameter for ASP need

    Same to Softswith;

    Bind AS&ASP;

    Check AS status

    Check ASP status

    2 ZXAN(config-msag)#isdn dlink span add 7 1 1 100 1

    ZXAN(config-msag)#show msag isdn dlink attribute

    Add Dlink,IID must same to SS

    Check ISDN Dlink status

    3 ZXAN(config-msag)#show msag slc terminationid 7

    ZXAN(config-msag)#slc terminationid add 7 BRA 1

    Check ISDN BRI terminal ID

    Add ISDN BRI user terminal ID

    4 ZXAN(config-msag)#ctrlport add 1 6610 info 1 Add ctrl port

    4) Simple trouble shooting

    1) First AS & ASP need active ,check parameter with SS

    2) Then capture the signal to check

    3.16. ISDN PRI CONFIGURATIONS

    Number Step Function

    1 ZXAN(config-msag)#as add 1

    ZXAN(config-msag)#asp add 1 6100 2905 1 10.16.98.102

    instream 8 outstream 8

    ZXAN(config-msag)#asasp add 1 1

    ZXAN(config-msag)#show msag as

    ZXAN(config-msag)#show msag asp

    Add AS ;

    Add ASP set parameter for ASP need

    Same to Softswith;

    Bind AS&ASP;

    Check AS status

    Check ASP status

    2 ZXAN(config-msag)#isdn dlink span add 8 pcm-no 1 1 17 1 1

    ZXAN(config-msag)#show msag isdn dlink attribute

    Add Dlink,IID must same to SS

    17 is the index for version 3

    Check ISDN Dlink status

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    3 ZXAN(config-msag)#show msag trunk terminationid 8 1

    ZXAN(config-msag)#trunk terminationid add 8 1 A

    begain-no 4001 type 2

    Check ISDN PRI terminal ID

    Add ISDN PRI user terminal ID

    4 ZXAN(config-msag)#ctrlport add 1 9899 info 1 Add ctrl port

    3.17. PPPOE+ function

    ZXAN(config)#pppoe-plus enable

    ZXAN(config)#interface adsl_2/11/2

    ZXAN(config-if)#pppoe-plus enable pvc 1

    ZXAN(config)#port-location ?

    access-node-identifier Config access-node-identifier info

    hostname Config port-location hostname

    vlan Config specific vlan

    vlan-control Config vlan control

    3.18. Function switch

    Function switch provides additional features which could adjust CPU to process certain type of

    traffic and disable the process for certain type of traffic for exam you enable CPU to process

    IGMP service but disable DDN service

    This file could be accessed by attaining the LICENSE.DAT placed inside CFG folder

    182_191_255_32-ITR_DHKLH_MG#dir

    Directory of flash:/

    attribute size date time name

    1 drwx 16384 JUL-06-2011 12:06:40 img

    2 drwx 16384 AUG-22-2011 20:10:40 cfg

    3 drwx 16384 AUG-29-2011 07:24:46 data

    4 drwx 16384 FEB-18-2010 10:31:54 gponont

    5 -rwx 8822 AUG-29-2011 07:29:50 error.log

    6 drwx 16384 FEB-18-2010 13:48:32 user

    7 -rwx 51645 JUN-10-2011 14:40:38 error.log.bak

    64880640 bytes total (43188224 bytes free)

    drwx ddirectory

    r read

    wwrite

    Img Version saved in this

    directory

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    xexcute

    drwx ddirectory

    r read

    wwrite

    xexcute

    Cfg Startrun.dat saved in

    this directory

    drwx ddirectory

    r read

    wwrite

    xexcute

    Data Narrowband data saved

    in this directory

    drwx ddirectory

    r read

    wwrite

    xexcute

    Gponont Gpon ont version saved

    182_191_255_32-ITR_DHKLH_MG#cd cfg

    182_191_255_32-ITR_DHKLH_MG#dir

    Directory of flash:/cfg

    attribute size date time name

    1 drwx 16384 AUG-22-2011 20:10:40 .

    2 drwx 16384 JAN-01-1970 00:00:00 ..

    3 -rwx 676 FEB-18-2010 13:48:48 license.dat

    4 -rwx 236108 AUG-22-2011 20:10:40 startrun.dat

    5 -rwx 4096 JUL-14-2011 01:19:08 nvram.dat

    64880640 bytes total (43188224 bytes free)

    License.dat There are many functions which defined by

    this file, H248,MGCP,DDN,ISDN etc.

    Startrun.dat Broadband data file, rack,shelf,card,etc.

    Nvram.dat Boot parameter, outband ip, mac,etc.

    You can download it by using this command

    ZXAN#copy flash: /cfg/license.dat ftp: //144.1.1.100/startrun.dat@root:root

    you just have to configure FTP server attributes before you download this data

    once you finish download this file open it in NOTEPAD and you will see:

    #ZXMSAG V2.0 License File

    #Comments must start with a '#' mark

    #Supported by WuFeng, [email protected]

    #define LM_ITEM_START_H248 ((int) 1) /*whether or not enable H.248 services*/

    #define LM_ITEM_START_MGCP ((int) 2) /*whether or not enable MGCP services*/

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    #define LM_ITEM_START_V5 ((int) 3) /*whether or not enable V5 services*/

    #define LM_ITEM_START_ISDN ((int) 4) /*whether or not enable ISDN services*/

    #define LM_ITEM_START_E1_MNG ((int) 5) /*e1 management*/

    #define LM_ITEM_START_ISDN2B ((int) 6) /*ISDN2B Term */

    #define LM_ITEM_START_SIP ((int) 7) /*whether or not enable SIP services*/

    1=1

    2=1

    3=1

    4=1

    5=1

    6=1

    7=1

    1 is for enabling any feature and 0 is to disable any feature.

    Set the parameters as per requirement adjust it if required . before doing this please contact

    zte if they allow then do it

    LM_ITEM_START_H248 INT 1 1 1:enable 0:disable

    LM_ITEM_START_MGCP INT 2 1 1:enable 0:disable

    LM_ITEM_START_V5 INT 3 1 1:enable 0:disable

    LM_ITEM_START_ISDN INT 4 1 1:enable 0:disable

    LM_ITEM_START_E1_MNG INT 5 1 1:enable 0:disable

    LM_ITEM_START_ISDN2B INT 6 1 1:enable 0:disable

    LM_ITEM_START_SIP INT 7 1 1:enable 0:disable

    3.19. STAND BY SS CONFIGURATIONS

    Use following commands to set stand by SOFT SWITCH whenever required

    ZXAN(CONFIG-MSAG)#mgc add

    2 10.20.16.2 port 2944 type 2 (TYPE 2 =hauwie TYPE 1 =ZTE)

    ZXAN(CONFIG-MSAG)# mg modify 1 1

    mgcid2 2 port 2944

    Show msag mg Check

    Show msag mgc Check

    3.20. SHDSL configration

    1). Test Enviroment

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    MSAGV3.1

    SHDSL MODEM

    SMARTBITS600B

    2). Hareware configration

    Main control card GISB slot 9

    SHDSL CARD GSDLB slot 15

    MODEM TAILET 1608

    SMARTBITS SMARTBITS 600B

    UPLINK SUBCARD GEI

    32 subscriber pin to port

    M S BLUE ORANGE GREEN BROWN

    WHITE 1 2 3 4

    RED 5 6 7 8

    BLACK 9 10 11 12

    YELLOW 13 14 15 16

    WHITEBLUE 17 18 19 20

    REDBLUE 21 22 23 24

    BLACKBLUE 25 26 27 28

    YELLOWBLUE 29 30 31 32

    GSDLB support 16 shdsl ports, the subscribe sequence is first 8 ports and last 8 ports

    There is a connector box: RJ45 transfer to subscriber

    RJ45 TRANSFERBOX SUBSCRIBER

    WHITEORANGE BLUE 4TH

    ORANGE YELLOW 5TH

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    WHITEGREEN BLACK 3RD

    BLUE RED 6TH

    WHITEBLUE GREEN 7TH

    GREEN YELLOW 8TH

    WHITEBROWN BROWN 1ST

    BROWN WHITE 2ND

    3). Software Configuration

    config rack shelf add rack shelf cards

    set data-path-mode msag(config)#interface shdsl_1/15/1-16

    msag(if-config)#data-path-mode efm

    modem only support

    efm mode

    create shdsl profile msag(config)#shdsl profile 2wire create 4wire and 8wire

    like this

    Apply profile to ports msag(config)#interfaceshdsl_1/15/1-4

    shdsl profile 2wire

    shdsl alarm profile sdefval.prf

    we use default alarm

    profile

    Config uplink and shdsl

    ports interface shdsl_1/15/1-4

    switchport mode hybrid

    switchport default vlan 1000

    interface fei_0/9/0

    no shutdown

    switchprot mode hybrid

    negotiation auto

    switchport defaut vlan 1000

    set modem with 8wire Pls check modem configuration docx

    check the synchronize

    status

    show shdsl port-status shdsl_1/15/1

    smartbits Send and receive packet for testing

    MSAG(CONFIG)#shdsl profile 2wire

    SpanConfWireInterface(1-twoWire,2-fourWire,3-sixWire,4-eightWire):[1]

    SpanConfMinLineRate(192..30000kbps):[200]

    SpanConfMaxLineRate(200..30000kbps):[6000]

    SpanConfPSD(1-symmetric,2-asymmetric):[1]

    SpanConfTransmissionMode(0-default,1-custom):[0]

    SpanConfRemoteEnabled(1-enable,2-disable)):[1]

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]

    SpanConfCurrCondTargetMarginDown(0..10dB):[5]

    SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]

    SpanConfCurrCondTargetMarginUp(0..10dB):[5]

    SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]

    SpanConfUsedTargetMargins(0-default,1-custom):[0]

    SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]

    SpanConfLineProbeEnable(1-disable,2-enable):[1]

    MSAG(CONFIG)#shdsl profile 4wire

    SpanConfWireInterface(1-twoWire,2-fourWire,3-sixWire,4-eightWire):[2]

    SpanConfMinLineRate(192..30000kbps):[200]

    SpanConfMaxLineRate(200..30000kbps):[6000]

    SpanConfPSD(1-symmetric,2-asymmetric):[1]

    SpanConfTransmissionMode(0-default,1-custom):[0]

    SpanConfRemoteEnabled(1-enable,2-disable)):[1]

    SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]

    SpanConfCurrCondTargetMarginDown(0..10dB):[5]

    SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]

    SpanConfCurrCondTargetMarginUp(0..10dB):[5]

    SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]

    SpanConfUsedTargetMargins(0-default,1-custom):[0]

    SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]

    SpanConfLineProbeEnable(1-disable,2-enable):[1]

    MSAG(CONFIG)#shdsl profile 8wire

    SpanConfWireInterface(1-twoWire,2-fourWire,3-sixWire,4-eightWire):[4]

    SpanConfMinLineRate(192..30000kbps):[200]

    SpanConfMaxLineRate(200..30000kbps):[6000]

    SpanConfPSD(1-symmetric,2-asymmetric):[1]

    SpanConfTransmissionMode(0-default,1-custom):[0]

    SpanConfRemoteEnabled(1-enable,2-disable)):[1]

    SpanConfPowerFeeding(1-noPower,2-powerFeed,3-wettingCurrent):[1]

    SpanConfCurrCondTargetMarginDown(0..10dB):[5]

    SpanConfWorstCaseTargetMarginDown(-10..10dB):[0]

    SpanConfCurrCondTargetMarginUp(0..10dB):[5]

    SpanConfWorstCaseTargetMarginUp(-10..10dB):[0]

    SpanConfUsedTargetMargins(0-default,1-custom):[0]

  • Confidential and Proprietary Information of ZTE CORPORATION

    Confidential and Proprietary Information of ZTE CORPORATION

    SpanConfReferenceClock(1-LocalClk,2-NetworkClk,3-DataOrNetworkClk,4-DataClk):[1]

    SpanConfLineProbeEnable(1-disable,2-enable):[1]

    4). test 4wires and 2wires like above procedures;

    NOTE

    pls make sure the pin to port is correctif it is wrongmaybe linkstatus is okbut service not through

    G,SHDSL TAINET MODEM CONFIGRATION.docx