MRS6014GB.2 Fieldbus PCI-card - Motoman...Page 2 Revised: 2011-11-30 MRS6014GB-2 Front Fieldbus...
Transcript of MRS6014GB.2 Fieldbus PCI-card - Motoman...Page 2 Revised: 2011-11-30 MRS6014GB-2 Front Fieldbus...
MANUAL NO.
2MRS6014GB
Part Number: 158050-1CDRevision: 1
FIELDBUS PCI-CARDINSTRUCTION MANUALFOR NX100 OR DX100 CONTROLLER
Upon receipt of the product and prior to initial operation, read these instructions thoroughly and retain for future reference.
MOTOMAN INSTRUCTIONS
MOTOMAN INSTRUCTIONSNX100 or DX100 INSTRUCTIONSNX100 or DX100 OPERATOR’S MANUALNX100 or DX100 MAINTENANCE MANUAL
The NX100 or DX100 operator’s manual above corresponds to specific usage. Be sure to use the appropriate manual.
Upon receipt of this product and prior to initial operation, read these instructions thoroughly, and retain for future reference.
INSTRUCTION MANUALFIELDBUS PCI-CARD
© 2011 YASKAWA NORDIC AB · Reg No.: MRS6014GB.2
Page 2 Revised: 2011-11-30 MRS6014GB-2 Front Fieldbus PCI-card.fm
Reference list
MOTOMAN NX100 Installation and wiring manual Fieldbus appendix (AnyBus manuals form HMS)
Revision
060425 First release of this document.
Revision
070208 New version including new fieldbus brands.
Revision
20111130 Now also covering DX100 controller.
Fieldbus PCI-card
1. General 3About this manual ........................................................................................3System requirements ....................................................................................3In manual included Fieldbus PCI-cards and NetTools .............................4Safety ..............................................................................................................5Manufacturer ................................................................................................5Introduction ..................................................................................................5Terms .............................................................................................................5Fieldbus systems ...........................................................................................6PCI-cards .......................................................................................................7Introduction to the fieldbus PCI-cards .......................................................7Hardware compatibility ...............................................................................7
2. Installation 9General ..........................................................................................................9Hardware installation ...................................................................................9
3. Software configuration 13Settings .........................................................................................................13Manual I/O allocation (FD 134) ................................................................17I/O map ........................................................................................................17Fieldbus status byte ....................................................................................18
4. Profibus DPV1 Slave 19Profibus Interface Details ..........................................................................19Card .............................................................................................................19PROFIBUS network setup .........................................................................21
5. Profibus DPV1 Master 23Profibus interface details ...........................................................................23Card .............................................................................................................23PROFIBUS network setup .........................................................................25
6. DeviceNet Adapter(Slave) 27DeviceNet Interface Details ........................................................................27Card .............................................................................................................27DeviceNet network setup ............................................................................29
7. DeviceNet Scanner(Master) 31DeviceNet Interface Details ........................................................................31Card .............................................................................................................31DeviceNet network setup ............................................................................33
8. AS-Interface Master 35AS-Interface Master ...................................................................................35Card .............................................................................................................35Principle of Input/Outputs in ASI .............................................................37Configuration interface ..............................................................................37
MRS6014GB.2 Fieldbus PCI-cardTOC.fm Revised: 11-11-29 Page 1
Fieldbus PCI-card
9. EtherNet/IP Master/scanner 47EtherNet/IP Master/Scanner interface details ........................................ 47Card ............................................................................................................. 47EtherNet/IP network setup ........................................................................ 49
10. EtherNet/IP Adapter/Slave 51EtherNet/IP Adapter/Slave interface details ........................................... 51Card ............................................................................................................. 51EtherNet/IP network setup ........................................................................ 54
11. PROFINET-IO Slave 55PROFINET-IO Slave interface details ..................................................... 55Card ............................................................................................................. 55Network setup ............................................................................................. 57
12. FL-Net 59FL-Net interface details ............................................................................. 59Card ............................................................................................................. 59Network setup ............................................................................................. 60
Page 2 Revised: 11-11-29 MRS6014GB.2 Fieldbus PCI-
Fieldbus PCI-cardAbout this manual
Fieldbus PCI-card
1. General
1.1 About this manualThis Instruction manual comprises information about: Installation Setup
This documents may not be copied without our written permission and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose.
The fieldbus PCI-cards are valid for YASKAWA controller NX100 and DX100 (hereafter called the controller).
Text written in BOLD letters means command or button.Text written in ITALIC means text shown on display.
WARNING! Observe precautions for handling electrostatic sensitive devices
1.2 System requirements1.2.1 NX100 Software For the fieldbus PCI-card installation, the PCI card driver and version NS3.14-01A (or
later) of the NX100 system software are required.
1.2.2 DX100 softwareNo specific requirements.
MRS6014GB-ch1.2 Fieldbus PCI-card.fm Revised: 11-11-30 Page 3
Fieldbus PCI-cardIn manual included Fieldbus PCI-cards and NetTools
1.3 In manual included Fieldbus PCI-cards and NetTools
Device: Motoman Part No
DeviceNet PCI-card, Scanner(Master) AB3604 34790090
DeviceNet PCI-card, Adapter(Slave) AB3603 34790080
Profibus DP PCI-card, Master AB3602 34790190
Profibus DP PCI-card, Slave AB3601 34790180
AS-Interface(ASI) PCI-card, Master AB3605 34790290
EtherNet/IP PCI-card, Master/Scanner AB3607 34790390
EtherNet/IP PCI-card, Slave/Adapter AB3606 34790380
PROFINET-IP PCI-card, Slave AB3609 34790480
FL-Net PCI-card, Slave AB3610 34790580
NetTool-DeviceNet (Network setup software) 8501405
NetTool-PROFIBUS (Network setup software) 8501401
ASI configuration cable
347583-80 (3 meters) (standard)
347583-81 (6)
347583-82 (9)
347583-83 (12)
347583-84 (15)
The delivered Fieldbus PCI-card kit comprises: PCI-card Software (drivers, GSD-files, EDS-files etc) Available on www.hms.se
The delivered Fieldbus NetTools comprises: Software Network adapter
Page 4 Revised: 11-11-30 MRS6014GB-ch1.2 Fieldbus
Fieldbus PCI-cardSafety
1.4 SafetyThis equipment is constructed, produced and tested according to the laws of the Member States relating to the EMC-directive (2004/108/EC) as well as the LVD-directives (2006/95/EC).
YASKAWA Nordic AB’s responsibility does not cover errors or safety risks that may occur in equipment connected to the YASKAWA Nordic AB machine, nor errors or safety risks that may occur in the machine caused by equipment con-nected to the YASKAWA Nordic AB’s machine.
External cables must be connected according to our cable connection guide, see separate document.
1.5 ManufacturerAddress YASKAWA Nordic AB
Box 504385 25 TorsåsSweden
Telephone: +46 480 417 800Telefax: +46 486 414 10
1.6 IntroductionThe purposes of this document is to provide instructions for users of the YASKAWA fieldbus PCI-cards and for supporting the configuration process. For further information regarding fieldbus configuration and programming please contact supplier.
This document is limited to the functionality of the fieldbus PCI-cards and the connections to the YASKAWA Robot Controller (hereafter referred to as the robot controller). It is assumed that the reader has an understanding of the functionality of the robot controller.
1.7 TermsThroughout this document the term “user“, refers to the person or persons who are installing and programming the robot controller with a fieldbus PCI-card installed. The end user of the robot equipment will be referred to as the customer.
As in all communication systems the terms “inputs“ and “outputs“ can be ambiguous, because their meaning depends on which end of the link that is being referenced. The convention in this document is that “inputs“ and “outputs“ are always being referenced from the robot con-troller end of the link.
MRS6014GB-ch1.2 Fieldbus PCI-card.fm Revised: 11-11-30 Page 5
Fieldbus PCI-cardFieldbus systems
1.8 Fieldbus systemsInstead of using traditional wiring to distribute input and output signals, the automation indus-try more frequently relays on computer communications. By using communication systems cost for material, installation, documentation and maintenance can be greatly reduced. The communication system can also be used for more advanced features like connecting different control systems and to distribute the control functions to intelligent sub-systems, sensors and actuators.
The communication systems used for these tasks are commonly called a fieldbus system. Fieldbus systems are used in all sectors of automation: Factory automation, manufacturing automation, assembly automation, building automation, process automation, etc.
Different systems are used because of different technical requirements of the application. Those different requirements are different levels of bus systems, bus structures, real-time behaviour, amount of data being transferred, transmission media, distribution of power on the communication media. The difference between the technical demands and the fact that no system on the market fulfils all requirements has lead to a wide variety of different fieldbus systems.
When designing a product which includes fieldbus systems it is necessary to also take the local computer network or communication system into consideration.
Page 6 Revised: 11-11-30 MRS6014GB-ch1.2 Fieldbus
Fieldbus PCI-cardPCI-cards
1.9 PCI-cardsThe PCI cards are optimized for PC-based industrial control and visualization applications and support. All boards are equipped with their own microprocessor to process the complete Fieldbus control independent from the host CPU of the PC. The Anybus PCI card family includes intelligent Master and Slave versions, providing effective solutions for a wide range of PC-based industrial applications.
The interface between the PCI cards and the CPU of the PC is based upon a Dual Port Ram. This guarantees a constant high data throughput and supports data consistency for the pro-cess data. The network configuration is created and loaded into the AnyBus PCI cards with the windows based NetTool configuration software.
1.10 Introduction to the fieldbus PCI-cardsThe PCI-cards are designed to make it possible to connect the robot control system to the most commonly used fieldbus systems on the market. It controls the exchange of data between the robot control system and the AnyBus system modules.
1.11 Hardware compatibilityThe fieldbus PCI-cards are electrically compatible with the motherboards in all current models of robot controllers. From the users point of view the fieldbus board will be used as a standard I/O board available for the robot controller.
Fig.1 PCI card system overview
MRS6014GB-ch1.2 Fieldbus PCI-card.fm Revised: 11-11-30 Page 7
Fieldbus PCI-cardHardware compatibility
Page 8 Revised: 11-11-30 MRS6014GB-ch1.2 Fieldbus
Fieldbus PCI-cardGeneral
2. Installation
2.1 General2.1.1 Specification 3.3 and 5 V support (Universal keyed add-in) Competitively priced - high performance Easy plug-and-play interface 33 Mhz PCI bus clock Common API used for all Anybus-PCI’s - one driver for all buses Supports Interrupt/Polling Free OPC server Drivers and API supporting Win 98/ME/NT/2000/XP SDK included (CD, drivers, DLL’s, sample code) 2 kB Dual Port RAM (4 kB Profibus Master) On-board microprocessor 256 byte mailbox interface extendable up to 2048 bytes for parameter data Galvanically isolated fieldbus interface comDTM driver for Profibus Master CoDeSys support (Profibus cards) 10/100MB Ethernet with included IT functions, Web, FTP server and more
2.1.2 Technical specification Size(W x L x D): 100 x 120 22 mm (3.94” x 4.72” x 0.87”) Power supply: 3.3 and 5 V, 600 mA VDC Temperature: operating 0° +55°C
2.1.3 Compliances and conformances EMC compliance: 2004/108/EC
-Emission: EN 61000-6-4:2001 -Immunity: EN 61000-6-2:2001
CE marked UL conformance Tested and verified for Fieldbus and network conformance RoHS compliance
2.2 Hardware installation
WARNING! To prevent electrical shock to personnel and to prevent equipment damage, ensure
power to the robot control system is turned OFF before beginning the installation The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to
observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges.
Never change any of the settings on the PCI-card while controller power is ON.The following installation instruction apply to all fieldbus PCI-cards delivered by YASKAWA.
MRS6014GB-ch2.2 Fieldbus PCI-card.fm Revised: 11-11-30 Page 9
Fieldbus PCI-cardHardware installation
2.2.1 NX100 Installation
PCI-card
Hole for securingscrew
1. Unplug AC power and remote system cover2. If present, remove the bracket opposite the PCI slot.3. Align the card connector with the slot and press firmly until the card is completely seated.4. Secure the card connector to the chassis using a screw.
INFORMATION!To ensure trouble-free operation, the front plate of the card must be screwed together with the system cover. The system cover must also be grounded in compliance with local regulations.5. Re-attach the system cover and AC power
Fig.2 PCI-card installation
Page 10 Revised: 11-11-30 MRS6014GB-ch2.2 Fieldbus
Fieldbus PCI-cardHardware installation
2.2.2 DX100 installation1. Remove the installation frame from the CPU rack. To do so, loosen the 4 marked screws.
See Fig.3. Remove installation frame.
2. Remove the cover and the retaining bracket for the PCI-card. Loosen the indicated screws in Fig.4. Cover.
Fig.3 Remove installation frame
Fig.4 Cover
MRS6014GB-ch2.2 Fieldbus PCI-card.fm Revised: 11-11-30 Page 11
Fieldbus PCI-cardHardware installation
3. Insert the PCI-card in an available slot. See Fig.5. PCI-card in slot.
4. Install the installation frame in the CPU-rack and fasten it using the 4 screws. See Fig.6. Installed frame.
Fig.5 PCI-card in slot
Fig.6 Installed frame
Page 12 Revised: 11-11-30 MRS6014GB-ch2.2 Fieldbus
Fieldbus PCI-cardSettings
3. Software configuration
3.1 Settings To setup the configuration of the system, maintenance mode has to be entered firstly.1. Maintenance mode:
To entrance maintenance mode keep the [MAIN MENU] pressed while turning the power supply on. The first window entered is following.
2. Go to Security by: Stepping to SYSTEM and choose by pressing [SELECT] button
3. On the appearing “pull down menu”, choose SECURITY.
4. In the MODE box in security window: Press [SELECT], Choose MANAGEMENT MODE and press [SELECT]. A password window will be shown
Fig.7 Menu maintenance
Fig.8 Security
MRS6014GB-ch3.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 13
Fieldbus PCI-cardSettings
5. Enter “99999999” and press [ENTER].
6. To do a setup: Step to SYSTEM and choose SETUP on the “pull down menu”.
7. In SETUP screen: Mark the OPTION BOARD and then press [SELECT].
Fig.9 Password
Fig.10 Setup
Page 14 Revised: 11-11-29 MRS6014GB-ch3.2 Fieldbus
Fieldbus PCI-cardSettings
8. Step to the PCI-card, object for installation(AB3605 ASI M in this fig). Press [SELECT].
9. Step to (A) and set the value to USED by [SELECT].10. On IO SIZE (B) the size of the signals are specified. Type the desired value and press
[ENTER]. The maximum values of this choice depends on the limitation of the different cards, see specific PCI-card.
11. The NODE ADDRESS (C). This is an unavailable choice on the ASI PCI-cards.12. Depending of the design of the fieldbus system, different BAUD RATE’s (D) are
desired. The maximum value of this choice depends on the limitation of the different cards, see specific PCI-card. This is an available choice only at the DeviceNet PCI-cards.
Fig.11 Option board (ASI PCI-card)
Fig.12 Setup for the choosen board(AB3604 DeviceNet M)
A)B)C)
D)
MRS6014GB-ch3.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 15
Fieldbus PCI-cardSettings
13. Press [ENTER].14. A question “MODIFY” appears. Select YES.15. You will continue to the IO MODULE.
16. In the IO MODULE, press [ENTER]. The card in CPU option 1 will allways be placed as number 16 (card in CPU option 2 as No.17). The amount of desired Inputs and Outputs (I/O’s) are shown (in DeviceNet Master ex. above 20 bytes x 8 bits + 8 status bits = 168 bits)
17. The last position will automatically be marked, press [ENTER] again.18. A question “MODIFY” appears. Select YES.
Fig.13 IO MODULE settings
Fig.14 PCI card (AB3602 Profibus M)
Page 16 Revised: 11-11-29 MRS6014GB-ch3.2 Fieldbus
Fieldbus PCI-cardManual I/O allocation (FD 134)
3.2 Manual I/O allocation (FD 134)The installed PCI-cards are given specific areas by default. But from generation DX100 it is possible to allocate certain areas. As an option this possibillity can be enabled. The procedure for this function is located in a separate instruction for External I/O signal allocation function
3.3 I/O mapDepending on the application of the system, the number of userdefinable I/O points will vary. The robot controller I/O’s follows a basic octal numbering system, i.e. each input or output group will occur in a grouping of eight. The NX100 system has the capability of supporting 1024 input and 1024 output signals. The DX100 system has the capability of supporting 2048 input and 2048 output signals.
3.3.1 Fieldbus input data mapThe data received from the PCI fieldbus card appears in the robot controller memory map according the tables below. The base address in the robot controller where the data will appear depends on the installation. In the examples below the PCI card inputs are repre-sented from address 20060.
Table above shows the memory map when the I/O size is set to a total of 24 input bits (16 fieldbus input bits).
Table above shows the memory map when the I/O size is set to a total of 56 input bits (48 fieldbus input bits).
Address Contents DescriptionMSB LSB
20060 Module and network statusStatus information. See section Fieldbus status byte på sidan 18 below.
20070 b7 b6 b5 b4 b3 b2 b1 b0 Fieldbus input byte 1 (b0 - b7)20080 b15 b14 b13 b12 b11 b10 b9 b8 Fieldbus input byte 2 (b8 - b15)
Address Contents DescriptionMSB LSB
20060 Module and network statusStatus information. See section Fieldbus sta-tus byte på sidan 18 below.
20070 b7 b6 b5 b4 b3 b2 b1 b0 Fieldbus input byte 1 (b0 - b7)20080 b15 b14 b13 b12 b11 b10 b9 b8 Fieldbus input byte 2 (b8 - b15)20090 b23 b22 b21 b20 b19 b18 b17 b16 Fieldbus input byte 3 (b16 - b23)20100 b31 b30 b29 b28 b27 b26 b25 b24 Fieldbus input byte 4 (b24 - b31)20110 b39 b38 b37 b36 b35 b34 b33 b32 Fieldbus input byte 5 (b32 - b39)20120 b48 b47 b46 b45 b44 b43 b41 b40 Fieldbus input byte 6 (b40 - b48)
MRS6014GB-ch3.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 17
Fieldbus PCI-cardFieldbus status byte
3.3.2 Fieldbus output data mapThe data transferred from the robot controller to the PCI fieldbus card appears in the robot controller memory map according the table below. The base address in the robot controller where the data will appear depends on the installation. In the examples below the PCI card inputs are represented from address 30060.
Table above shows the memory map when the I/O size is set to a total of 24 output bits (16 fieldbus output bits).
Table above shows the memory map when the I/O size is set to a total of 56 output bits (48 fieldbus output bits).The first byte of output data is reserved for future use and is not accessed by the PCI fieldbus card. This byte should not be used by the robot controller program.
3.4 Fieldbus status byteOne byte of input status data is generated by the PCI fieldbus card. The status byte contains information about the PCI card and the fieldbus environment. The byte is continuously updated by the software. The information available in this byte can be used by the robot con-troller to monitor the PCI card and the fieldbus system.
The status byte contains the following information:
Address Contents DescriptionMSB LSB
30060 Reserved Not available for use30070 b7 b6 b5 b4 b3 b2 b1 b0 Fieldbus output byte 1 (b0 - b7)
30080 b15 b14 b13 b12 b11 b10 b9 b8 Fieldbus output byte 2 (b8 - b15)
Address Contents DescriptionMSB LSB
30060 Reserved Not available for use30070 b7 b6 b5 b4 b3 b2 b1 b0 Fieldbus output byte 1 (b0 - b7)30080 b15 b14 b13 b12 b11 b10 b9 b8 Fieldbus output byte 2 (b8 - b15)30090 b23 b22 b21 b20 b19 b18 b17 b16 Fieldbus output byte 3 (b16 - b23)30100 b31 b30 b29 b28 b27 b26 b25 b24 Fieldbus output byte 4 (b24 - b31)30110 b39 b38 b37 b36 b35 b34 b33 b32 Fieldbus output byte 5 (b32 - b39)30120 b48 b47 b46 b45 b44 b43 b41 b40 Fieldbus output byte 6 (b40 - b48)
Bit no: Function Valid
0 0 Not used
1 0 Not used
2 0 Not used
3 0 Not used
4 0 Not used
5 1 = Some configured slaves are unreachable Master only
6 1 = All configured slaves are unreachable Master only
7 1 = Master is unreachable Slave only
Page 18 Revised: 11-11-29 MRS6014GB-ch3.2 Fieldbus
Fieldbus PCI-cardProfibus Interface Details
4. Profibus DPV1 Slave
4.1 Profibus Interface Details Complete Profibus DPV1 Slave functionality according to extensions of IEC 61158 Up to 244 bytes input and 244 bytes output Supports PA baud rate up to 45.45 Kbit/s Supports class 1 and class 2 services Automatic baudrate detection (9.6 kbit/s - 12 Mbit/s) RS-485 optically isolated Profibus interface with on-board DC/DC converter
4.2 Card
Warning!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors , and han-dle the card only by its edges.
4.2.1 Status LED:s
Fig.15 PCI Profibus DPV1 slave card
No. Indication State Meaning
1 Appl. connectedGreen Controlled by application
Red Standalone
2 I/O ACCESS
Green flashing I/O accesses going on
Red flashing I/O access failure (recoverable)
Off No activity
MRS6014GB-ch4.2 Fieldbus PCI-card.fm Revised: 11-11-28 Page 19
Fieldbus PCI-cardCard
4.2.2 Connectors 9-pin D-sub
The 9-pin D-sub is the standard connector and is recommended for data transfers rates higher than 1500kbit/s.
3 Acyclic TrafficOff No power or no DPV1 request currently being
executed
Green A DPV1 request is currently being executed
4 Fieldbus Diagnostics
Off No diagnostics present or no power on the mod-ule
Red, Flashing 1 Hz Error in configuration data
Red, Flashing 2 Hz Error in parameter data
Red, Flashing 4Hz Profibus ASIC initialisation error
5 Fieldbus On Line
Off Bus is not online, or no power on the nodule
Green Bus is online and data exchange is possible
Green, flashing Clear mode
6 Fieldbus Off lineOff Bus is off line
Red Bus is off line, or no power on the module
Fig.16 D-subs, male and female layout
Pin Signal
Housing Shield
1 NC
2 NC
3 B-Line
4 RTS*
5 GND BUS**
6 +5V BUS**
7 NC
8 A-Line
9 NC
No. Indication State Meaning
Male Female
Page 20 Revised: 11-11-28 MRS6014GB-ch4.2 Fieldbus
Fieldbus PCI-cardPROFIBUS network setup
*) RTS is used in some equipment to determine the direction of transmission. In normal appli-cations only A-Line, B-Line and shield are used.**) +%V BUS and GND BUS are used for bus termination. Some devices, like optical trans-ceivers(RS485 to fibre optics) might require external power supply from these pins.
4.3 PROFIBUS network setupFor a complete network setup See “PROFIBUS network setup” on page 25. Each slave device in a PROFIBUS network is associated with an GSD-file which has to be downloaded to the network.
4.3.1 The GSD-file The GSD-file, contains all the necessary information about the device. The configuration tool uses the GSD-file during configuration of the Profibus DP network.
INFORMATION!The latest version of the GSD-file can either be downloaded from http://www.anybus.com or received by contacting HMS.
MRS6014GB-ch4.2 Fieldbus PCI-card.fm Revised: 11-11-28 Page 21
Fieldbus PCI-cardPROFIBUS network setup
Page 22 Revised: 11-11-28 MRS6014GB-ch4.2 Fieldbus
Fieldbus PCI-cardProfibus interface details
5. Profibus DPV1 Master
5.1 Profibus interface details Complete Profibus class 1 and class 2 Master according to IEC 61158 Up to 125 DP/DPV1 slaves can be connected Upto 1536 bytes input and 1536 bytes output data Supports Profibus baud rates up to 12 Mbit/s RS-485 optically isolated Profibus interface with on-board DC/DC converter Configuration via Anybus NetTool Windows based configuration software
5.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges.
5.2.1 Status LED:s
Fig.17 PCI Profibus DPV1 Master card
No. Indication State Meaning
1 Appl. connectedGreen Controlled by application
Red Standalone
2 I/O ACCESS
Green flashing I/O accesses going on
Red flashing I/O access failure (recoverable)
Off No activity
MRS6014GB-ch5.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 23
Fieldbus PCI-cardCard
INFORMATION!If all indicators goes RED, it means “Fatal error”.
Fieldbus interface
Male Female
3 Master status
Green Operate Mode
Green flashing Clear Mode
Red Stop Mode
Off Offline
4 Token holdGreen Master has the token
Off Master does not have the token
5 Database Status
Green Database OK
Green flashing Database download in progress
Red Database invalid
Off No database downloaded
6 Communication status
Green Data exchange with all configured slaves
Green, flashing Data exchange with at least one configured slave
Red Bus control error (Possible short circuit or config-uration error)
Off No data exchange with any off the configutated slaves
Fig.18 D-subs, male and female layout
Pin D-sub (Male) Signal
Housing Cable shield
1 -
2 -
3 B-Line
4 RTS
No. Indication State Meaning
Page 24 Revised: 11-11-29 MRS6014GB-ch5.2 Fieldbus
Fieldbus PCI-cardPROFIBUS network setup
Serial interface
Pin D-sub (Male) Signal
Housing PE
1 -
2 RxD
3 TxD
4 -
5 GND
6 -
7 -
8 -
9 -
5.3 PROFIBUS network setupTo be able to setup the PROFIBUS fieldbus network, the AnyBus NetTool for PROFIBUS is recommended to use.
5.3.1 The AnyBus NetTool for PROFIBUSAnybus NetTool for Profibus is a configuration tool to create complete Profibus-DP network configurations. The graphical workbench of NetTool allows the compilation of Profibus net-work configurations based on slave GS*-files. By online functionality the Profibus configura-tion can be downloaded to the master module and the I/O-data of the connected slaves be monitored and modified.
The configuration tool includes all necessary software and a hardware interface to configure, manage and troubleshoot your PROFIBUS network. When installed, go to the Help-menu where all necessary information/guidelines for the
setup can be found.
5.3.2 TerminationThe end nodes(first and last nodes) in a PROFIBUS network must be terminated to avoid reflections on the bus line. Attach a terminating resistor, equal to 220 ohms, to each end of the data transfer cable.
The resistors are connected across the A- and B-lines(Pin 8 and 3 of the SUB-D connector).
5 GND_BUS
6 +5V BUS (output)
7 -
8 A-Line
9 -
Pin D-sub (Male) Signal
MRS6014GB-ch5.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 25
Fieldbus PCI-cardPROFIBUS network setup
WARNING!If you do not use terminating resistors as described, the PROFIBUS cable system will NOT operate properly.
5.3.3 Node settingsAll nodes have to be, by hardware, setup according to the configuration defined in the soft-ware. The kind of setting device is varying, depending on which manufacturer used.
5.3.4 Coniguration onlineThe network configuration have to be scanned and downloaded to the PCI-card. Before going online a connection must be established to the configuration connector on the PROFIBUS PCI-card.
Page 26 Revised: 11-11-29 MRS6014GB-ch5.2 Fieldbus
Fieldbus PCI-cardDeviceNet Interface Details
6. DeviceNet Adapter(Slave)
6.1 DeviceNet Interface Details Complete DeviceNet 2.0 Adapter implementationaccording to ODVA, group 2 only
server DIP switch select baud rate and MACID Baud rate 125-500 kbit/s Optically isolated DeviceNet interface Up to 512 bytes input and 512 output data
6.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors , and han-dle the card only by its edges.
6.2.1 Status LED:s
Fig.19 PCI DeviceNet adapter(slave) card
No. Indicate State Meaning
1 Appl. connectedGreen Controlled by application
Red Standalone
2 I/O ACCESS
Green flashing I/O accesses going on
Red flashing I/O access failure (recoverable)
Off No activity
MRS6014GB-ch6.2 Fieldbus PCI-card.fm Revised: 11-11-28 Page 27
Fieldbus PCI-cardCard
6.2.2 Connectors Application interface
The module is available in both serial and parallel versions.
Fieldbus interface
1. 2. 3. 4. 5.
Pin Signal Decription
1 V- Negative supply voltage*
2 CAN_L CAN_L bus line
3 shield Cable shield
4 CAN_H CAN_H bus line
5 V+ Positive supply voltage
INFORMATION!The layout in figure is from a male connector. the female connectors are in opposite order.
3- - (not used)
4
5 Network Status
Off No power or not online
Green Link OK, online, connected
Green, flashing Online not connected
Red Critical link failure
Red, flashing Conection timeout
6 Module status
Off No power to device
Green Device operational
Green, flashing Data size bigger than configured
Red Unrecoverable fault
Red, flashing Minor fault
Fig.20 Male Connector DeviceNet
No. Indicate State Meaning
Page 28 Revised: 11-11-28 MRS6014GB-ch6.2 Fieldbus
Fieldbus PCI-cardDeviceNet network setup
6.3 DeviceNet network setupFor a complete network setup See “DeviceNet network setup” on page 33. Each slave device in a DeviceNet network is associated with an EDS-file which has to be downloaded to the network.
6.3.1 The EDS-file The EDS-file contains all the necessary information about the device. The configuration tool uses the EDS-file during configuration of the DeviceNet network.
INFORMATION!The latest version of the EDS-file can either be downloaded from http://www.hms.se or received by contacting HMS.
MRS6014GB-ch6.2 Fieldbus PCI-card.fm Revised: 11-11-28 Page 29
Fieldbus PCI-cardDeviceNet network setup
Page 30 Revised: 11-11-28 MRS6014GB-ch6.2 Fieldbus
Fieldbus PCI-cardDeviceNet Interface Details
7. DeviceNet Scanner(Master)
7.1 DeviceNet Interface Details Complete DeviceNet 2.0 scanner implementation according to ODVA Group 2 Client/Server/UCMM support Optically isolated DeviceNet interface Baud rate 125-500 kbit/s Up to 512 bytes input & 512 butes output data Controls up to 63 DeviceNet slaves/Adapters Supports FLASH field upgrades Configuration via Anybus Nettool or RSNetworx
7.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges
7.2.1 Status LED:s
Fig.21 PCI DeviceNet scanner(master)
No. Indication State Meaning
1 Appl. connectedGreen Controlled by application
Red Standalone
2 I/O ACCESS
Green flashing I/O accesses going on
Red flashing I/O access failure (recoverable)
Off No activity
MRS6014GB-ch7.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 31
Fieldbus PCI-cardCard
7.2.2 Connectors Fieldbus interface
1. 2. 3. 4. 5.
Pin Signal Decription
1 V- Negative supply voltage*
2 CAN_L CAN_L bus line
3 shield Cable shield
4 CAN_H CAN_H bus line
5 V+ Positive supply voltage
INFORMATION!The layout in figure is from a male connector. the female connectors are in opposite order.
3 - - (not used)
4 Operation mode
Off No power or not initialized
Flashing Green Idle mode
Green Run mode
5 Network status
Off No power, not initialized or no connection estab-lished
Flashing green Online, no connection established
Green Online, at least one connection established
Flashing Red Minor fault; at least one connection has a minor fault
Red Critical link failure
6 Module status
Off No power or not initialized
Green Module status OK
Flashing red Minor fault
Red Major fault
Fig.22 Male Connector DeviceNet
No. Indication State Meaning
Page 32 Revised: 11-11-29 MRS6014GB-ch7.2 Fieldbus
Fieldbus PCI-cardDeviceNet network setup
7.3 DeviceNet network setupTo be able to setup the DeviceNet fieldbus network, the AnyBus NetTool for DeviceNet is rec-ommended to use.
7.3.1 The AnyBus NetTool for DeviceNetThe AnyBus NetTool for DeviceNet is a Configuration Tool that allows configuration and main-tenance of your DeviceNet Network. Setup functions include full Scanner configuration and DeviceNet slave configuration. The AnyBus NetTool-DN lets users configure, manage and troubleshoot any DeviceNet network or network component on a DeviceNet network.
The tool consists of a Windows 32-bit graphical network configuration software and a DIN rail mountable adapter that connect a PC, via RS232, to the DeviceNet cable. The configuration tool includes all necessary software and a hardware interface to configure, manage and trou-bleshoot your DeviceNet network. When installed, go to the Help-menu where all necessary information/guidelines for the
setup can be found.
7.3.2 TerminationThe end nodes(first and last nodes) in a DeviceNet network must be terminated to avoid reflections on the bus line.
Attach a terminating resistor equal to 121 ohms, 1 %, 1/4W or greater wattage, to each end of the trunk cable. The resistors are connected across the CAN_H and CAN_L lines (Blue and white wires of the DeviceNet cable).
WARNING!If you do not use terminating resistors as described, the DeviceNet cable system will NOT operate properly.
7.3.3 NodesAll nodes have to be, by hardware, setup according to the configuration defined in the soft-ware. The kind of setting device is varying, depending on which manufacturer used.
7.3.4 Configuration onlineThe network configuration have to be scanned and downloaded to the PCI-card. Before going online a connection must be established to the DeviceNet network. The adapter can be con-nected parallelly anywhere within the fieldbus network
MRS6014GB-ch7.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 33
Fieldbus PCI-cardDeviceNet network setup
Page 34 Revised: 11-11-29 MRS6014GB-ch7.2 Fieldbus
Fieldbus PCI-cardAS-Interface Master
8. AS-Interface Master
8.1 AS-Interface Master Complete AS-Interace Master supporting version 2.1 and also backwards compatible
with version 2.0 Controls up to 62 AS-Interface slaves Up to 248 digital outputs/186 digital inputs Up to 124 (16 bit) analog values Optically isolated interface Full extended master M1E Supports auto-configuration or configuration via RS-232 using standard Windows hyper-
terminal program on PC
8.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges.
8.2.1 Status LED:s
Fig.23 PCI AS-Interface Master
No. Indication State Meaning
1 Appl. connectedGreen Controlled by application
Red Standalone
MRS6014GB-ch8.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 35
Fieldbus PCI-cardCard
8.2.2 Connectors
1. 2. 3.
Pin Signal
1 AS-Interface +
2 -
3 AS-Interface -
8.2.3 Rectifying of interruptionSince there are possibilities of AS-interface being affected by interruption, a ferrite clip should be attached to its bus cable according to this figure.
2 I/O ACCESS
Green flashing I/O accesses going on
Red flashing I/O access failure (recoverable)
Off No activity
3 Running/IdleGreen Module is in running mode
Red Module is in idle mode
4 Auto prog, slave 0 exist
Off No error, no slave 0, autoprogrammming not possible
8Hz Green Auto programming possible
1Hz Green Slave address 0 exist
Red Periphery error
8Hz Red Perophery error, auto-programming possible
1Hz Red Periphery error, slave address 0 exist
5 Network status
Off No power or not initialized
Flashing green online according to configuration
Green Online, but no connections established
Red Offline
6 Module status
Off No power or not initialized
Flashing green Protected mode
Green Configuration mode
Red Power fail bus
Fig.24 Connector PCI AS-interface Master
Fig.25 Ferrite clip on cable
No. Indication State Meaning
Page 36 Revised: 11-11-29 MRS6014GB-ch8.2 Fieldbus
Fieldbus PCI-cardPrinciple of Input/Outputs in ASI
8.3 Principle of Input/Outputs in ASI
INFORMATION!For every Input or Output in ASI the respective Input/Output will be allocated(blocked).
The Inputs/Outputs of the nodes in an ASI fieldbus system can be set up as in following example:
8.4 Configuration interfaceThis interface provides a simple text based interface via the onboard RS232 interface. All net-work configuration parameters are available using a standard terminal emulator such as the windows Hyperterminal.
INFORMATION!No data exchange is halted and no mailbox activity is possible while using this interface.
The interface uses the following communication settings:Terminal emulation: ASCIIBaudrate: 38400Databits: 8Stopbits: 1Parity: NoneFlowcontrol: None
I/O NO: Function Comment
25-32 8 bits of system status For NX100 specific fieldbus status data
33-36 4 bits of system status For ASI fieldbus system internal status data. Allways 4 first bits of the first node in ASI.
37-404 bits of data input
Node 14 bits of data output
41-444 bits of data input
Node 24 bits of data output
45-484 bits of data input
Node 34 bits of data output
49-524 bits of data input
Node 44 bits of data output
MRS6014GB-ch8.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 37
Fieldbus PCI-cardConfiguration interface
8.4.1 Menu Tree Overwiev
Fig.26 Menu tree
Page 38 Revised: 11-11-29 MRS6014GB-ch8.2 Fieldbus
Fieldbus PCI-cardConfiguration interface
Enable Terminal Interface MenuThe module displays the following screen when connecting to the configuaration interface.
To activate the configuration interface, press [Enter]. Note that data exchange and mailbox activity will be halted until the RS232 cable is physically disconnected.
Main menuThe following menu entries are available from the main menu. Detailed information of each menu entry is presented in the following pages.
Fig.27 Enable terminal interface menu
MRS6014GB-ch8.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 39
Fieldbus PCI-cardConfiguration interface
The status section reflects the contents of the AS-Interface flag bytes.
View scan-listsThis command displays all network status lists in the format shown below:
Fig.28 Main menu
Page 40 Revised: 11-11-29 MRS6014GB-ch8.2 Fieldbus
Fieldbus PCI-cardConfiguration interface
- = No slave presentX = Slave present
Fig.29 Scan-list
MRS6014GB-ch8.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 41
Fieldbus PCI-cardConfiguration interface
View all nodesThis command displays I/O configuration, ID codes and all parameters for slave.
View all detected nodesThis command will display all detected nodes
To alter a setting for a specific node, type the desired node address and press [Enter].
Fig.30 All nodes
Fig.31 Detected nodes
Page 42 Revised: 11-11-29 MRS6014GB-ch8.2 Fieldbus
Fieldbus PCI-cardConfiguration interface
View single nodeThis command displays information about a single node.
To view or alter the settings for a specific node, type the desired node address and press [Enter].
Toggle mode This mode is used to alter the current operating mode of the module.
Press [ESC] to cancel.
Online/Offline modeThis command is used to toggle Online/Offline mode.
Press [ESC] to cancel.
Fig.32 Single node
Fig.33 Toggle mode
Fig.34 Online/Offline mode
MRS6014GB-ch8.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 43
Fieldbus PCI-cardConfiguration interface
Auto addressThis command is used to enable/disable the automatic address programming feature.
Press [ESC] to cancel.
Save configurationThis command stores the current configuration into non-volatile memory.
Press [Enter] to store the current configuration, or press [ESC] to cancel.
NOTE!This command is not allowed in protected mode.
8.4.2 Alter settingsThis menu is displayed when a specific node has been selected in main menu commands 1 to 4.
Fig.35 Auto address
Fig.36 Save configuration
Page 44 Revised: 11-11-29 MRS6014GB-ch8.2 Fieldbus
Fieldbus PCI-cardConfiguration interface
To alter the value of a parameter, select the desired parameter by typing the corresponding number and press [Enter]
A menu similar to the one below is displayed, allowing the selected parameter to be altered.
Fig.37 Alter settings
MRS6014GB-ch8.2 Fieldbus PCI-card.fm Revised: 11-11-29 Page 45
Fieldbus PCI-cardConfiguration interface
Type the new value and press [Enter]. The parameter value will change accordingly.
Fig.38 Change parameter
Page 46 Revised: 11-11-29 MRS6014GB-ch8.2 Fieldbus
Fieldbus PCI-cardEtherNet/IP Master/Scanner interface details
9. EtherNet/IP Master/scanner
9.1 EtherNet/IP Master/Scanner interface details Complete EtherNet/IP Master/Scanner interface Dual Port (DPRAM) parallel interface Ethernet settings configurable through an inbuilt web server or with on-board DIP
switches EtherNet/IP level 4 I/O client - ODVA certified Transformer isolated Ethernet interface IT functions dynamic web, FTP server and Email client
9.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges.
9.2.1 Status LED:s
Fig.39 PCI EtherNet/IP Master card
No. Indication State Meaning
1 Link/Activity
Green Link estabished
Green flashing Activity; recieving/transmitting data
Off No link or power off
1 2
4 3
A
View A
MRS6014GB-ch10.1 Fieldbus PCI-card.fm Revised: 11-11-29 Page 47
Fieldbus PCI-cardCard
INFORMATION!If all indicators goes RED, it means “Fatal error”.
2 Module status
Green Device operational- Module is operating correctly in Run-state
Green, flashingStandby- Module has not been configured- Scanner in Idle-state
Red Major fault- Major unrecoverable fault
Red flashingMinor fault- Minor recoverable fault (originated on timeout)- An originated connection could not be opened
Alternating Red/Green Self test- Module is performing power up test procedures
Off No power
3 Network status
GreenConnected- The module has at least one established Ether-Net/IP connection (target or originated)
Green flashing
No connections- There are no EtherNet/IP connections estab-lished to the module (class 1 or class 3, target or originated)
Red Duplicate IP- Configured IP address already in use
Red, flashing
Connection timeout- One or several EtherNet/IP target connections have timed-out- The module can only leave this state if all timed-out target connections are re-established, or if the module is reset
Off No power or no IP address
4 - - -
No. Indication State Meaning
Page 48 Revised: 11-11-29 MRS6014GB-ch10.1 Fieldbus
Fieldbus PCI-cardEtherNet/IP network setup
Fieldbus interface
1 8
Pin RJ45 (Female) Signal
1 TD+
2 TD-
3 RD+
4 Termination
5 Termination
6 RD-
7 Termination
8 Termination
9.3 EtherNet/IP network setupTo configure the EtherNet/IP fieldbus network RS-Networx is used.
Fig.40 RJ45 female layout
MRS6014GB-ch10.1 Fieldbus PCI-card.fm Revised: 11-11-29 Page 49
Fieldbus PCI-cardEtherNet/IP network setup
Page 50 Revised: 11-11-29 MRS6014GB-ch10.1 Fieldbus
Fieldbus PCI-cardEtherNet/IP Adapter/Slave interface details
10. EtherNet/IP Adapter/Slave
10.1 EtherNet/IP Adapter/Slave interface details Complete EtherNet/IP Adapter/Slave interface IP address settings configurable through on-board DIP switches, Webpage, DCP or
DHCP Baud rate: 10/100 MBit/s EtherNet/IP level 2 I/O server Transformer isolated Ethernet interface IT functions Dynamic web, FTP server and Email client
10.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges.
Fig.41 PCI EtherNet/IP Slave card
1 2
4 3
A
View A
MRS6014GB-ch11.1 Fieldbus PCI-card.fm Revised: 11-11-29 Page 51
Fieldbus PCI-cardCard
10.2.1 Status LED:s
No. Indication Configuration Colour State Meaning
1 Link(Activity)
1 GreenOn The module has a link
Off The module do not sense a link
2 Green
On The module has a link
Off The module do not sense a link
Flashing The module is recieving/transmitting on ethernet
2 Module sta-tus
1
Green Flashing 1HZ IP address not set using configuration switch
Red
Flashing 1HZ Invalid MAC address. (Internal error)
Flashing 2HZ Failed to load Ethernet configuration from FLASH
Flashing 4HZ Internal error. (Fatal)
On Duplicate IP address detected
2
GreenOn The module operates in 100Mbit
Off The module operates in 10Mbit
Red
Telephone flash (2 flashes on and long off)
Invalid MAC address
Telephone flash (3 flashes on and long off)
Failed to load Ethernet configuration from FLASH
Telephone flash (4 flashes on and long off)
Internal error. (Fatal)
Telephone flash (5 flashes on and long off)
Duplicate IP address detected
3
- Off No power applied to the module
GreenOn The module is operating correctly
Flashing The module has not been configured
RedFlashing A minor recoverable fault has been
detected
On A major internal error has been detected
Green/Red Flashing The module is performing a power on self
test
4 - - This configuration deactivates this Led
Page 52 Revised: 11-11-29 MRS6014GB-ch11.1 Fieldbus
Fieldbus PCI-cardCard
INFORMATION!If all indicators goes RED, it means “Fatal error”.
3 Network sta-tus
1 - -
In this configuration, this Led indicates the number of Modbus/TCP connections to the module. The number of established connections is equal to the number of flashes on this Led.
2 - - This configuration deactivates this Led
3
- Off The module has no power or no IP address has been assigned
GreenOn The module has at least one established
EtherNet/IP connection
Flashing There are no Ethernet/IP connections established to the module
RedFlashing
One or more of the connections in which this module is the target has timed-out. This state is only left if all timed-out con-nections are re-established or if the mod-ule is reset
On The module has detected that its IP address is already in use
Green/Red Flashing The module is performing a power on self
test
4 Activity
1 Green Flashing A packet is recieved or transmitted
2 - -In this configuration, this Led is deactived and the activity and link indications are merged
No. Indication Configuration Colour State Meaning
MRS6014GB-ch11.1 Fieldbus PCI-card.fm Revised: 11-11-29 Page 53
Fieldbus PCI-cardEtherNet/IP network setup
Fieldbus interface
1 8
Pin RJ45 (Female) Signal
1 TD+
2 TD-
3 RD+
4 Termination
5 Termination
6 RD-
7 Termination
8 Termination
10.3 EtherNet/IP network setupTo configure the EtherNet/IP fieldbus network RS-Networx is used.
Fig.42 RJ45 female layout
Page 54 Revised: 11-11-29 MRS6014GB-ch11.1 Fieldbus
Fieldbus PCI-cardPROFINET-IO Slave interface details
11. PROFINET-IO Slave
11.1 PROFINET-IO Slave interface details Complete PROFINET-IO device functionality Max. 1300 bytes of input and 1300 bytes of output data 100 Mbit full duplex transmission RJ45 connector Powerful 32 Bit processor for short cycle times GSD file for easy configuration IT functions dynamic web, FTP server and Email client
11.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges.
11.2.1 Status LED:s
Fig.43 PCI PROFINET-IO Slave card
No. Indication State Meaning
1 Link/Activity
Green Link established
Green flashing Recieving/transmitting data
Off No link or power off
1 2
4 3
A
View A
MRS6014GB-ch12.1 Fieldbus PCI-card.fm Revised: 11-11-29 Page 55
Fieldbus PCI-cardCard
INFORMATION!If all indicators goes RED, it means “Fatal error”.
2 Communication status
GreenOnline, RUN- Connection with IO controller established- IO controller is in RUN state
Green, 1 flashOnline, STOP- Connection with IO controller established- IO controller is in STOP state
Off Offline- No connection with IO controller
3 Module status
Green Initialized, no error
Green, 1 flash Diagnostic data available
Green, 2 flashes Blink. Used by an engineering tool to identify the Anybus module
Red, 1 flash
Configuration Error- Too many modules/submodules- I/O size derived from IO controller configuration is too large- Configuration mismatch 8no module, wrong module)
Red, 3 flashes No station name or no IP address assigned
Red, 4flashes Internal Error
Off No power or not initialized
4 - - -
No. Indication State Meaning
Page 56 Revised: 11-11-29 MRS6014GB-ch12.1 Fieldbus
Fieldbus PCI-cardNetwork setup
Fieldbus interface
1 8
Pin RJ45 (Female) Signal
1 TD+
2 TD-
3 RD+
4 Termination
5 Termination
6 RD-
7 Termination
8 Termination
11.3 Network setupTo configure network e.g. Step7 HWconfig is used.
Fig.44 RJ45 female layout
MRS6014GB-ch12.1 Fieldbus PCI-card.fm Revised: 11-11-29 Page 57
Fieldbus PCI-cardNetwork setup
Page 58 Revised: 11-11-29 MRS6014GB-ch12.1 Fieldbus
Fieldbus PCI-cardFL-Net interface details
12. FL-Net
12.1 FL-Net interface details Complete FL-Net server functionality Support shielded (STP) and unshielded (UTP) cables FL-Net class 1 node Customizable identity/profile information Up to 512 bytes cyclical I/O in each direction Dual Port (DPRAM) parallel interface Transformer isolated Ethernet interface
12.2 Card
WARNING!The card contains ESD (Electrostatic Discharge) sensetive components. Be sure to observe ESD precautions when installing the card; do not touch any circuits or connectors, and handle the card only by its edges.
12.2.1 Status LED:s
Fig.45 PCI FL-Net card
No. Indication State Meaning
1 LNKGreen Link established
Off No link established
1 2
4 3
A
View A
MRS6014GB-ch13.1 Fieldbus PCI-card.fm Revised: 11-11-29 Page 59
Fieldbus PCI-cardNetwork setup
INFORMATION!If all indicators goes RED, it means “Fatal error”.
Fieldbus interface
1 8
Pin RJ45 (Female) Signal
1 TD+
2 TD-
3 RD+
4 Termination
5 Termination
6 RD-
7 Termination
8 Termination
12.3 Network setupTo configure network e.g. Step7 HWconfig is used.
2 ERR
RedUnit needs to be replaced (e.e. invalid MAC ID)... or.. Anybus watchdog enabled and not updated properly
Red, flashing Parameter error
Off Normal state
3 FL-LNKGreen Participating on FL-Net
Off Not participating on FL-Net
4 COMGreen Packet recieved or transmitted
Off No activity
Fig.46 RJ45 female layout
No. Indication State Meaning
Page 60 Revised: 11-11-29 MRS6014GB-ch13.1 Fieldbus
Notes
YASKAWA Nordic ABPO Box 504, SE-385 25 Torsås, SwedenPhone: +46-480-417800, Fax: [email protected]
YASKAWA Company group:
AT YASKAWA Europe GmbHAm Concorde Park 1/B6/108-110, AT-2320 Schwechat-Wien, Austria Phone +43-1-707-9324-15
CZ YASKAWA Czech s.r.o.West Business Center Chrášt’any, Chrášt’any 206CZ-252 19 Rudná u Prahy, Czech Republic Phone +420-257-941-718
DE YASKAWA Europe GmbHKammerfeldstrasse 1, DE-85391 Allershausen, Germany Phone: +49-8166-90-0
DK YASKAWA Nordic ABRobotcenter Danmark Helge Nielsens Allé 7, 2E, DK-8723 Løsning, DenmarkPhone: +45-7022-2477
ES YASKAWA Iberica S.L.Avenida Marina 56 b, Parcela 90, ES-08830 St. Boi de Llobregat (Barcelona), SpainPhone: +34-93-6303478
FI YASKAWA Finland OYMessinkikatu 2, FI-20380 Turku, FinlandPhone: +358-403000600
FR YASKAWA S.A.R.LRue Nungesser et Coli, D2A Nantes-Atlantique, FR-44860 Saint-Aignan-de-Grand-Lieu, FrancePhone: +33-2-40131919
IT YASKAWA Italia SRLVia Massimo d’Antona 41/43, IT-10040 Rivalta di Torino, ItalyPhone: +39-011-9005833
NL YASKAWA Benelux B.VScience Park Eindhoven 5031, Industrieterrein EkkersrijtNL-5692 EB Son, The NetherlandsPhone: +31-40-2895500
PT YASKAWA Iberica S.L.Z. Ind. Aveiro Sul, lote 21 N. S. Fátima, PT-3810 Aveiro, PortugalPhone: +351-234-943-900
RU YASKAWA Nordic AB2B Otradnaya Building 2RU-127237 Moscow, RussiaPhone:+7 495 6442409
SE YASKAWA Nordic ABP.O. Box 504, Verkstadsgatan 2, SE-385 25 Torsås, SwedenPhone: +46-480-417800
SI YASKAWA Slovenia d.o.o.Lepovce 23, Parcela 90, SI-1310 Ribnica, Slovenia Phone: +386-1-8372410
SL YASKAWA GmbH, o.z.Kutlikova 17 821SK-02 Bratislava, SlovakiaPhone: +421 2 6828 6535
UK YASKAWA UK LtdJohnson Park, Wildmere Road, Banbury, Oxon OX16 3JU, United KingdomPhone: +44-1295-272755
Distributors
BG Kammarton Bulgaria LtdSofia +359 (02) 926 6060
CZ Hadyna International spol. s.r.o.Ostrava-Marianske Hory +420 596 622 636
CH MESSER Eutectic Castolin Switzerland S.A.Dällikon +41-44-847 17 17
GR Kouvalias Roboticsvlona +30-22950 42902
HU Rehm Hegesztéstechnika KftBudapest +36-53-380 078
HU Flexman Robotics Kft.Budapest +36-30-951 0065
IL YASKAWA Europe Technology LTD.Rosh Haáyin +972-3-9004114
LT Profibus UABPanevezys +370-45-518575
NO Optimove asLierstranda +47-32240600
PL Integrator RHC Sp.z.o.oTorun +48 56 65 19 710
RO Sam Robotics srlTimisoara +40 720 279 866
TR Teknodrom Robotics & Automation INCGebze/Kocaeli +90 262 678 8818
ZA Robotic Systems SA PTY LtdJohannesburg +27-11-6083182
FIELDBUS PCI-CARD INSTRUCTION MANUALFOR NX100 OR DX100 CONTROLLER
2MRS6014GBMANUAL NO.
Specifications are subject to change without noticefor ongoing product modifications and improvements.