MR8518_8518.pdf
Transcript of MR8518_8518.pdf
![Page 1: MR8518_8518.pdf](https://reader031.fdocuments.in/reader031/viewer/2022020202/577cc2f81a28aba71194e130/html5/thumbnails/1.jpg)
MRx18
miniRepeater
Simple, affordable, compact, and extremely easy to setup,
the MRx18 miniRepeater is the ideal solution for extending
coverage in small venues ranging from 2,300 square meters
(25,000 square feet) and smaller. Two band segments are pro-
vided by the MRx18, particularly to cover Band A and AE or
Band B and BE. The positioning of the filters can be determined
by entering the start frequency via web based GUI.
Eliminating the need for bulky and expensive test equipment
like spectrum analyzers, everything you need to determine
proper signal levels can be viewed on the LCD display. No
special software or hardware is required to set up the MRx18
miniRepeater. Autogain functionality enables automatic gain
adjustment in order to maximize the unit’s performance, while
still allowing gain to be set manually if desired. The Ethernet
port on the unit allows for easy connectivity and commissioning through a web-based browser.
The MRx18 allows remote monitoring—alarms are forwarded via SNMP V1 traps.
Key Features
• Multi-functional capabilities and modular design
• Continuously monitors and adapts to the RF environment via Autogain feature
• Lightweight and compact footprint for easy installation
• Easy commissioning and setup via web-based browser
• Fixed bandwidth to be matched to Band A and AE or Band B and BE
• Variable positioning of filters within the frequency band by individual start frequency setting
• LEDs for local alarm indicators
• LCD display for RSSI, Gain, Output Power, and Status Indication
• Remote alarming through SNMP alarm traps
• Connection to LAN
• Compliant with all regulatory agencies
MR8518/8518Indoor Coverage and 850 MHz Cellular Applications
![Page 2: MR8518_8518.pdf](https://reader031.fdocuments.in/reader031/viewer/2022020202/577cc2f81a28aba71194e130/html5/thumbnails/2.jpg)
www.commscope.com/andrewVisit our Web site or contact your local Andrew Solutions representative for more information.
© 2010 CommScope, Inc. All rights reserved.
Andrew Solutions is a trademark of CommScope. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Andrew Solutions products or services.
BR-103807-EN (01/10)
Status, Setting, and Maintenance interfaces make for easy configuration
MR8518/8518
Electrical
Uplink Downlink
Frequency range, MHz 824 to 849. . . . . . . . . . 869 to 894
RF output power, dBm +22 @ 1 carrier. . . . . . . +22 @ 1 carrier +19 @ 2 carriers . . . . . . +19 @ 2 carriers
OICP3, dBm +41 . . . . . . . . . . . . . +41
P-1dBc, dBm +28 . . . . . . . . . . . . . +28
Noise figure 8.0 . . . . . . . . . . . . . 8.0 maximum gain, dB
Spurious emission, dBm . . . . . . . . . . . . . . . . <-13
Gain, dB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Gain adjust range, dB. . . . . . . . . . . . . . . . . . . . . 30 in steps of 1
Bandwidth options, MHz . . . . . . . . . . . . . . . . . . . Fixed Bandwidth Band Segment 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8 Band Segment 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .start frequency adjustable
Flatness, dB . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3
Delay, µs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Power Supply Mains Power, Vac . . . . . . . 100 to 240 Local Power, Vdc . . . . . . . . 6
Power consumption, watts* . . . . . . . . . . . . . . . . . 20
Antenna port Connectors . . . . . . . . . . . SMA Female Return loss, dB . . . . . . . . . 10
Indoor antenna . . . . . . . . . . . . . . . . . . . . . . . . . . Optional
Antenna gain, dBi. . . . . . . . . . . . . . . . . . . . . . . . 2.0
System Supervision and Control
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature, current, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ALC, heartbeat
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMS-Alarming
Environmental
Operating temperature range, °C. . . . . . . . . . . . . +5 to +40
Ingress protection . . . . . . . . . . . . . . . . . . . . . . . . IP30
Mechanical
Height, width, depth, mm (in). . . . . . . . . . . . . . . . 240 x 240 x 35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(9.5 x 9.5 x 1.4)
Weight, kg (lb) . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 (3.3)
* without power supply All figures are typical values
Specifications