Low Energy Door Operator
Complies with ADA Accessibility Guideline
MPower 3000
Copyright 20062009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
-
8/3/2019 MPower 3000 Data Sheet
2/129014
6:C08/01/11
Copyright2006-2009,2011,SargentMan
ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve
d.
Reproductioninwholeorinpartwithoutth
eexpresswrittenpermissionofSargentManufacturingCompanyisproh
ibited.
1-800-727-5477 www.sargentloc.com
Table of ContentsMPower 3000 Low Energy Door Operator
On the Cover
3000
Patents: 5,881,497, 7,316,096 and 7,484,333
MPOWER 3000 Series is the latest generation of power dooroperators. Low energy door operators were once considered anecessity only for those with physical challenges. Today, due tothe populations busy lifestyles, the convenience of hands-freedoor opening is more popular than ever. The patented designof MPOWER 3000 is based on ease and simplicity. MPOWER3000 installs in minutes rather than hours and consists of threebasic components: inverter, motor and closer body.
What separates MPOWER 3000 Series from other operators isits ability to function as a standard door closer. When the door is
opened manually, there is little resistance and the drive train andmotor are not engaged. The closer, not the motor, controls theclosing cycle. Since the door closer does not back-drive the motorduring the closing cycle, there is no loss of closer efficiency. In theevent of a power outage, the door can be manually opened andwill close via the door closers spring force.
MPOWER 3000 Series is listed with UL and ANSI/BHMA A156.19and meets the requirements of ADA and ANSI/BHMA 156.4.MPOWER 3000 is ideal for doctors offices, retirement facilities,schools, churches, and any location where noise is a majorconcern and special features are not a requirement. MPOWER3000 can be activated via wall switch, radio frequency device ormotion sensor, and is available for push or pull side applications.Based on its dual functionality, ease of use and quiet operation,MPOWER 3000 Series offers the customer a unique choice!
Note: Any retrofit or other field modification to a fire ratedopening can potentially impact the fire rating of the opening, andSargent Manufacturing Company makes no representations orwarranties concerning what such impact may be in any specificsituation. When retrofitting any portion of an existing fire ratedopening, or specifying and installing a new fire-rated opening,please consult with a code specialist or local code official(Authority Having Jurisdiction) to ensure compliance with allapplicable codes and ratings.
Overview & Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Standard Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
How to Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
T y p i c a l D o o r T r a f f i c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
S w i t c h e s & R F P a r t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical System Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Technical Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Architectural Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
-
8/3/2019 MPower 3000 Data Sheet
3/1211-800-727-5477 www.sargentloc.com
Overview & CertificationsMPower 3000 Low Energy Door Operator
Ease of installation and setup- Simple instructions
Application versatility and ease of adjustment- Push or pull side mounting units available
Operates as mechanical surface closer during close cycles,when door is opened manually or if power is turned off
- Quiet operation- Spring force provides the feel of a normal manual
door closer- Door can be opened manually if desired
SARGENT 1130 series door closer- Adjustable Spring Power- Backcheck Valve- Sweep Valve & Latch Valve
Non-handed
Unit Activation Options- Wall switches- Radio frequency device
End-User On/Off Switch
Hold open options- 0-30 seconds (5 seconds minimum required for ADA and
ANSI/BHMA A156.19)
Obstruction detection- Motor stops if door is obstructed during an opening- Door closes under manual spring force (not to exceed
15lbf)
Push and Close- Allows the operator to skip the hold open time
when it is not necessary or required- Adjustable door sensitivity
Overload Safety Shut-Off- After two minutes of receiving a door activation
signal, the inverter will time out and close the door- Prevents motor/inverter damage
Motor Start Delay for Locking Hardware- 0-5 second delay to allow locking hardware to release first
Features & Functions
Power Input; 120 VAC, 60Hz
Current Draw: .6A or .3A
Relay Output: DPDT- Normally Open/Normally Closed (jumper)
- For electric strike function
Electrical Data
C-UL US listed for use on fire and smoke barrier doors
2-year warranty (refer to current SARGENT price bookfor terms & conditions)
Meets requirements for Americans with Disabilities Act (ADA)
ANSI/BHMA A156.19 certified
Meets ANSI/BHMA A156.4 requirements
Certifications
InverterMotor
1130 Closer Body
-
8/3/2019 MPower 3000 Data Sheet
4/129014
6:C08/01/11
Copyright2006-2009,2011,SargentMan
ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve
d.
Reproductioninwholeorinpartwithoutth
eexpresswrittenpermissionofSargentManufacturingCompanyisproh
ibited.
21-800-727-5477 www.sargentloc.com
Standard ApplicationsMPower 3000 Low Energy Door Operator
Standard Applications
3060
Hinge (Pull) Side of Door
Adjustable Stop 180 swing (trim permitting)
Minimum Door widthSingle Door - 29" (74cm)Double Door - 30" (76cm)
An auxiliary stop is suggested where severe conditions exist.
NOTE: Contact factory for use on doors exceeding 250 lbs.
3051Stop (Push) Side of Door
Standard Duty Double Lever Arm Frame reveals 2-5/8" to 6-3/4" (67-171mm) An auxiliary door stop is required for these applications 170 swing (trim permitting)
NOTE: Contact factory for use on doors exceeding 250 lbs.
-
8/3/2019 MPower 3000 Data Sheet
5/1231-800-727-5477 www.sargentloc.com
How to OrderMPower 3000 Low Energy Door Operator
Note: Door switches and sensors are not included with the MP3000Series Door Operators. These items must be ordered separately.
SARGENT
DesignationDescription
BHMA
Designation
EN Sprayed Aluminum 689
EB Sprayed Bronze 690
EAB Sprayed Brass 696
3051 x finish
For stop (push) side of the door withdouble lever arm for reveals 2-5/8" to6-3/4" to swing up to 170
3060 x finish
For hinge (pull) side of the door withrigid arm & slide track for a maximumreveal of 1/8" to swing up to 180
How to Order:
-
8/3/2019 MPower 3000 Data Sheet
6/129014
6:C08/01/11
Copyright2006-2009,2011,SargentMan
ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve
d.
Reproductioninwholeorinpartwithoutth
eexpresswrittenpermissionofSargentManufacturingCompanyisproh
ibited.
41-800-727-5477 www.sargentloc.com
Typical Door TrafficMPower 3000 Low Energy Door Operator
APPLICATION DAILY AVERAGE YEARLY AVERAGE USAGE OPERATOR
Executive Office
ADA Dorm Room
ADA Hotel orRetirement Home Room
Assisted Living Up to 100 Up to 22,000 Low Low EnergyCommon Area Door
Office/Warehouse Door
ADA Auxiliary Entrance
ADA Accessible Restroom
Government/Public Restroom 300 108,000
Hospital Corridor Door 600 220,000
Office Building Entrance 1,200 450,000 Moderate
Airport Entrance 3,000* 1,100,000
Large Office Building Entrance 4,000* 1,200,000
Large Dept. Store Entrance 5,000* 1,500,000
* Representspowered cycles
Note: The above applications and data are examples for guidance only. Contact your
ASSA ABLOY Door Security Solutions Sales Representative or SARGENT Technical Consultantto confirm the suitability of your specification and system design.
Typical Door Traffic Categories
Moderate
MP3000
Besam HighEnergy Door
Operator
High
MP4000 LowEnergy
-
8/3/2019 MPower 3000 Data Sheet
7/12
REED SWITCH
CHAIN63-0781
RF POWER SUPPLY
BREAKER SWITCH
(optional)
OPEN / CLOSE POSITIONING ASSEMBLY63-4293
PINION EXTENSION / CLUTCH ASSEMBLY63-4295
1130 SERIES
CLOSER BODYMOTOR ASSEMBLY
63-4294
POWER SWITCH63-0783 BACKPLATE
INVERTER
63-0784
51-800-727-5477 www.sargentloc.com
Parts ListMPower 3000 Low Energy Door Operator
63-4287 - Arm and Track Assembly63-4288 - Arm Assembly63-4289 - Track Assembly
63-4290 - Standard Arm Assembly63-4291 - Arm Assembly less Rod
and Shoe63-4292 - Foot Assembly
Arm and Trac Assemblies
COVER63-0780
Parts List
-
8/3/2019 MPower 3000 Data Sheet
8/129014
6:C08/01/11
Copyright2006-2009,2011,SargentMan
ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve
d.
Reproductioninwholeorinpartwithoutth
eexpresswrittenpermissionofSargentManufacturingCompanyisproh
ibited.
61-800-727-5477 www.sargentloc.com
Switches and RF PartsMPower 3000 Low Energy Door Operator
SARGENTMODEL DESCRIPTION VIEW NOTES
4396HP
6" x 6" Squarewall switch
with handicap
logo & Pressto Open
Momentary SPDT contacts rated at500ma @ 12 VDC or 24 VAC
Mounts in standard single or double gangelectrical box or in 6-1/2" x 6-1/2" x 1-3/4"surface mount box provided
Wireless Switch Option:- Operates at 433MHz- Operator requires RF receiver (#RFR1)- Switch is to be surface mounted in box provided- Specify RF to switch number to order
(Ex: 4395HPRF)
4396P6' x 6" Square
wall switch withPress to Open
4395HP
6" Roundwall switch withhandicap logo &Press to Open
4395P6" Round
wall switch withPress to Open
FOB1Key Fob
Transmitter 433MHz Key Fob used with RF Receiver
RFR1 RF Receiver Radio Frequency Receiver (433 MHz) 24 VDC power supply Activation switches not included.
4397HPNarrow type
switch
Mounts flush through a 1-3/4" x 2-7/8" cutout injamb or in the 4-3/4" x 2" x 1-7/8" box provided
Momentary SPDT contacts rated at500ma @ 12 VDC or 24 VAC
43411" x 3/4"
Surface MountPushbutton
Surface mount push button Momentary DPST contacts rated at 3 Amps
43992" Square
GreenPushbutton
Single gang push button with green LED Momentary SPDT contacts rated at 10 Amps
Accessories
Supplied with each MP3000 is the 63-4306 Signage Kit which containstwo of each of the three labels shown above
-
8/3/2019 MPower 3000 Data Sheet
9/1271-800-727-5477 www.sargentloc.com
Typical System ApplicationsMPower 3000 Low Energy Door Operator
ACCESS CONTROL FOR ENTRYOpening Description: Fail SecureADA Opening Electric Strike &Door Operator
ApplicationRated or Non-Fire Rated Metal Door Interior or Exterior Office, Main Entranceor Stairwell Openings
Operation Activate or deactivate system by a key
control switch When outside, door switch is inactive,
ingress will be by Pin or Prox only Inside door switch will unlock
and open the door automatically Push exit device bar to exit at
all times
Door operator acts as standarddoor closer when entering orexiting manually
Material SARGENT MPower 3000 Door Operator SARGENT 8900 Mortise Exit Device 2-SARGENT 4396HP Door Switches SARGENT 4370L Maintained Key Switch SARGENT 4293 Wall Prox Card Reader HES 1006 Electric Strike 1- 12 VDC or 24 VDC Regulated and
Filtered Power Supply Dual out put timer by others
120 VAC
ELECTRIC STRIkESOpening Description: Fail Secure ADAOpening Double Electric Strike & DoorOperators on Pair of Doors
ApplicationInterior, Non-Fire Rated Wood or Metal
Doors Corridor or Emergency RoomOpenings
Operation Doors are to be closed and latched at
all times Key Switch activates and deactivates
door switches to signal door operators Active door switch will energize the
electric strike and automaticallyopen doors
Door operators will act as standarddoor closers when entering or exitingmanually
Material 2-SARGENT MPower 3000 Door
Operators
FOLGER ADAMS 310-4-1 Double ElectricStrike
2-SARGENT 8700 Surface Vertical RodExit Devices
2-SARGENT 4396HP Door Switches SARGENT 4370L Maintained Key Switch SARGENT 4293 Wall Prox Dual output timer by other
120 VAC
MAGNETIC LOCkOpening Description: Fail SafeADA Opening - Magnetic Lock &Door Operator
ApplicationNon-Fire Rated Glass Door -Interior or Exterior Office or MainEntrance Openings
Operation Lock or unlock system by a key control
switch at all times Free ingress & egress using thedoor operator or manuallywhen unlocked
Outside door switch will be inactivedenying ingress other than by Pin orProx when locked
To exit, inside door switch will unlockmagnetic lock and open the door ormanually push bar to exit
Door operator acts as standard doorcloser when entering or exiting manually
Material SARGENT MPower 3000 Door Operator SARGENT 1584 Electromagnetic Lock McKINNEY QC4 Electric Hinge SARGENT 55-8895 Mechanical Touch
Bar with Switch
2-SARGENT 4396HP Door Switches SARGENT 4370L Maintain Switch SARGENT 4293 Wall Prox
120 VAC
Note: Not available for use with latch retraction exit devices
-
8/3/2019 MPower 3000 Data Sheet
10/129014
6:C08/01/11
Copyright2006-2009,2011,SargentMan
ufacturingCompany,anASSAABLOYGroupcompany.Allrightsreserve
d.
Reproductioninwholeorinpartwithoutth
eexpresswrittenpermissionofSargentManufacturingCompanyisproh
ibited.
81-800-727-5477 www.sargentloc.com
Technical DetailsMPower 3000 Low Energy Door Operator
Circuit breaker
Activation switch terminal Relay terminal
POT DESCRIPTION
H/O TQMotor Torque at Hold OpenPosition
REV SPD Motor Reversing Speed
M/DLY Motor Delay on Opening
H/O TM Hold Open Time (5 - 30 Seconds)
OBSTR SENS Obstruction Detection on Open
PUSH SENSE Push Recognition Sensitivity
-
8/3/2019 MPower 3000 Data Sheet
11/1291-800-727-5477 www.sargentloc.com
Architectural SpecificationsMPower 3000 Low Energy Door Operator
General Specifications
2.0 Low Energy Door Operators
A. Door Controls____ (interior) (exterior) swinging door(s) shall be of rack and pinion design contained within a precision castaluminum housing.
B. Door closing force shall be adjustable to ensure adequate closing control.
C. Door closing speed shall be controlled by independent hydraulic adjustment valves in the sweep and latch range of the closing cycle.
D. Door Operator shall provide conventional door closer opening forces unless the power operator motor is activated.
E. Door Operator shall provide conventional door closing forces at all times except in the event of power outage duringpowered door open cycle.
F. Door Operator opening force and speed shall be adjustable by independent electronic adjustment to ensure adequateopening control per accessibility codes.
G. Door Operator shall have an adjustable hydraulic backcheck valve to cushion the door speed if door is opened violently.
H. Door Operator shall have a manual adjustment to locate both full open and full closed door positions.
I. Maximum door open shall be adjustable and capable to a maximum 180 conditions permitting.
J. Door Operator shall be SELECTIVELY ACTIVATED by external initiating device, i.e., wall switch, etc.
K. Door Operator shall be both AUTOMATICALLY ACTIVATED and SELECTIVELY ACTIVATED.
L. Door operator shall have adjustable hold open time capability in range from 5 to 30 seconds.
K. Door operator shall have input line rating of 120VAC, .6A or 240VAC, .3A.
M. Units shall have relay contact for interfacing products having a contact rating of 30VDC at 1A or 125VAC at .5A.
N. Unit shall have an external On/Off Switch to defeat powered opening when desired.
O. Unit shall have an internal circuit breaker switch to interrupt input power for servicing.
P. Unit shall be U.L. Listed for automatic closing door.
Q. Unit shall be in compliance with the requirements of the Americans With Disabilities Act (ADA), ANSI standards A117.1 andA156.19. Unit shall meet C-UL US.
Additional Detailed SpecificationsA. When activated, the unit shall, by means of an integral motor and chain drive, power open the door at both a speed and force
that are adjustable to meet accessibility codes.
B. The door shall be powered from a door closed position to a full door open position and remain in momentary hold openfor ___seconds (adjustable 0 to 30 seconds) [(Unit shall power open door to full open position up to 180 (3060); 170(3051), conditions permitting.) (Unit shall be capable of allowing the door to be opened manually from 0 to 180, conditionspermitting.)]
C. Once unit reaches full hold open position, if reinitiated, units momentary hold open time shall restart from the initially sethold open time.
D. If unit is initiated during the closing cycle, unit shall revert to opening cycle beginning at that door position.
E. Obstruction detection on open shall neutralize and reverse motor action reverting motor to closed position thus allowingdoor to close under closer spring force only.
F. This obstruction detection feature shall be integral to unit.G. During closing cycle, the unit shall close door under spring power not to exceed a closing force of 15 lbf.
-
8/3/2019 MPower 3000 Data Sheet
12/12
90146 C 08/01/11
SARGENT Manufacturing Company100 Sargent Drive, New Haven, CT 06511 USA800-727-5477 www.sargentlock.com
Founded in the early 1800s, SARGENT is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The companys customer base includes commercial construction, institutional, and industrial markets.
Copyright 2006-2009, 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisf ing end ser needs for sec rit safet and con enience