MPFM-50 SERIES€¦ · high, Agar’s unique flow range extender (F.R.E.) MPFM-50 design is used....

4
MPFM-50 SERIES

Transcript of MPFM-50 SERIES€¦ · high, Agar’s unique flow range extender (F.R.E.) MPFM-50 design is used....

  • MPFM-50 SERIES

  • The AGAR MPFM-50 is a low-cost multiphase meter that continues the long tradition of excellent multiphase meters provided by Agar for over 15 years.

    AdvAnTAGES OF ThE AGAR MPFM-50 SERIES:

    • Gasvoidfraction0-100%

    • Water-cut0-100%

    • Notaffectedbyflowregimes

    • Highaccuracy,real-timeflowmeasurement

    Highandlowviscosities

    • Nonuclear(radioactive)sources

    • Compact,portable,andeasytotransportand

    install

    • Wetgasapplication

    FEATuRESTheAGARMPFM-50combinesadvancedcoriolis

    technologywithtraditionalflow-measurementdevices

    toachievesuperioraccuracyintheentireGVFrange;

    0-100%,includingthewetgasregimefrom95-100%.

    TheAGARMPFM-50isalow-cost,compactmultiphase

    flowmeterthatcanaccuratelymeasureoil,water,

    andgasflowrateswithoutseparation.TheAGARoil/

    watermonitoriscapableofmeasuringwatercutsfrom

    0-100%andisnotaffectedbychangingsalinities.

    TheAGARMPFM-50eliminatestheneedforexpensive,

    secondaryequipmentsuchasphaseseparators,

    valves,andpumpsforflowmeasurement.Itisfully

    self-containedandcompactforuseinruggedfield

    conditionsandcaneasilybetrailer-mountedfor

    portableservice.

    TheAGARMPFM-50isa

    multiphaseflowmeteringtoolfor

    fieldandwelloptimization,capable

    ofhandlingallflowregimes.

    World-ClassProcessMeasurement

    &ControlSolutions

    MPFM-50 COMPRISES FIvE

    PRIMARY SubSYSTEMS:

    • The mass flow and density

    measurement isbasedon

    coriolisandotherancillary

    sensors.Engineeringadvances

    allowAgartoutilizethesesensorsatextended

    operatingmultiphaseflowranges.Themassflow

    momentumanddensitydataarefedintotheAGAR

    DataAnalysisSystem(DAS),whichdeterminesthe

    netgasflowrateandnetliquidflowrate.density.

    Water-cutdataisfedintotheDASandusedto

    determinetheindividualoilandwaterflowrates

    fromthenetliquidflowrate.

    • TheAGARWater-cutmeter(OW-201orOW-301)

    isusedtomeasurewatercontentaccuratelyover

    thefullrangeof0-100%inbothoilandwater-

    continuousphases.Accuracyisnotaffected

    bychangesinvelocity,salinity,pH,viscosity,

    temperature,ordensity.Water-cutdataisfedinto

    theDASandusedtodeterminetheindividualoil

    andwaterflowratesfromthenetliquidflowrate.

    • TheAGARDataAnalysisSystem(DAS)performs

    on-lineanalysisofdataacquiredfromtheabove

    subsystemstodeterminetheoil,water,gas,and

    totalfluidflowrates.ItsupportsavarietyofPVT

    calculationsthatconverttheflowfromprocess

    conditionstostandardconditions.Italsohasthe

    abilitytoacceptuserdefinedPVTrelations.

    • HighFlowRateCapability:Inapplicationswhere

    theflowlineislargerthan4”andtheflowrateis

    high,Agar’suniqueflowrangeextender(F.R.E.)

    MPFM-50designisused.Inthisdesigna2”MPFM-

    50isinstalledonthesplitstreamandflownozzle

    andGVFisinstalledonthemainstream.This

    designhastheabilitytomanageanyflowrateand

    pipesizeatalowcostandhighaccuracy.

    • TheAgarDualVenturiMeterisusedtomeasure

    flowratesofthemultiphaseinextremeconditions

    wheretheflowisnothomogeneous.

    MPFM-50 SERIES

    Email: [email protected]

  • TYPICAL APPLICATIOnS• The AGAR Water-cut meter (OW-201 or OW-

    301) isusedtomeasurewatercontentaccurately

    overthefullrangeof0-100%inbothoiland

    water-continuousphases.Accuracyisnotaffected

    bychangesinvelocity,salinity,pH,viscosity,

    temperature,ordensity.Water-cutdataisfedinto

    theDASandusedtodeterminetheindividualoil

    andwaterflowratesfromthenetliquidflowrate.

    • The AGAR data Analysis System (dAS)performs

    on-lineanalysisofdataacquiredfromtheabove

    subsystemstodeterminetheoil,water,gas,and

    totalfluidflowrates.ItsupportsavarietyofPVT

    calculationsthatconverttheflowfromprocess

    conditionstostandardconditions.Italsohasthe

    abilitytoacceptuserdefinedPVTrelations.

    • high Flow Rate Capability:Inapplicationswhere

    theflowlineislargerthan4”andtheflowrateis

    high,Agar’suniqueflowrangeextender(F.R.E.)

    MPFM-50designisused.Inthisdesigna2”MPFM-

    50isinstalledonthesplitstreamandflownozzle

    andGVFisinstalledonthemainstream.This

    designhastheabilitytomanageanyflowrateand

    pipesizeatalowcostandhighaccuracy.

    • The Agar dual venturi Meterisusedtomeasure

    flowratesofthemultiphaseinextremeconditions

    wheretheflowisnothomogeneous.

    MPFM-50 GEnERAL SPECIFICATIOnSPREFERREd InSTALLATIOn:Verticalupwardflow

    ElECTRICAl:PowerSupply:24VDC,110&220VAC

    PowerRequirements:50Wattsforthebasicoption

    (lowerpoweroptionsavailableuponrequest)SAFETY

    CERTIFICATIOnS:ATEX:Sensor-II1GExiaIIBT4

    (-20ºC

  • ACCuRACYTheaccuraciesshownbelowtakeintoaccountchangesinsalinity,viscosity,density,temperature,pressure,andpH.

    MPFM-50 SERIES

    Email: [email protected]

    INS-DS-0102-JUNE2018