MovinCool Classic and Classic Plus Series€¦ · MovinCool Classic and Classic Plus series units...
Transcript of MovinCool Classic and Classic Plus Series€¦ · MovinCool Classic and Classic Plus series units...
MovinCool® Classic and Classic Plus Series
The Portable Spot Cooling Solution
Features
• Digital Temperature Controls
• Up to 26,000 Btu/h of Cool Air
• Economical
• Handles Wide OperatingTemperature Ranges
• Rugged Reliable Design
• Dramatic Temperature Drop
• Totally Self-Contained
• No Costly Installation Needed
Benefits
• Easy-to-use digital controls let you set the desired temperature.*
• Maximum spot air conditioningBtu/h provides cool air to just the spot that needs it.
• Costs as little as 10 cents per hour to run.
• Operates in high temperatureranges, far beyond what most air conditioners can handle.
• Performs in the harshestenvironments, 24 hours a day, seven days a week.
• Up to a 30-degree drop fromambient temperature, required foreffective spot air conditioning.
• All-in-one design provides for convenient, low maintenance operation.
The Classic
When the heat is on, turn on the MovinCool Classic & Classic Plus series…
People, processes, and equipmentdon’t perform well under extremeheat. That’s why more companies relyon the proven performance of ourMovinCool Classic and Classic Plusseries units to spot air condition theirheat-sensitive areas.
MovinCool’s portable airconditioning system:Improves employee moral andmanufacturing quality … relievingworkers from extreme environmentsto increase productivity and prevent heat exhaustion.
Reduces excess cool-down time for production processes … eliminating heat-related defects and additional scrap.
Protects equipment fromdowntime due to heat … saving systems from a costly failure or shutdown, which can cripple daily operations.
DENSO, the pioneer of portable airconditioning and manufacturer ofMovinCool is a registered ISO 9002facility. Every unit passes through aseries of performance tests to ensure100% quality and is UL approved. So when the heat starts, stop it withthe MovinCool Classic and Classic Plusportable air conditioning systems.
Simply roll it in,plug it in and turn it on!**
© 2002 American Standard Inc. All rights reserved RSP-SLB066-EN
* For Classic Plus 14 and Classic Plus 26 models only.
** Exhaust duct required in some applications.
Auto Condensate RemovalWhy bother with emptying the drain tank when you can install a condensate pump to remove the water automatically? This pump has an 18-ft liftcapacity to reach virtually any remote drain. With the condensate pump installed, drainage is automatic and access to the compartment is no longernecessary. A cover plate can then be added to conceal and protect the pump.
# PART NAME CLASSIC 10 CLASSIC 18 CLASSIC PLUS 14 CLASSIC PLUS 26
Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN
9 Cover Plate COV03325 484009-0480 COV03325 484009-0480 COV03325 484009-0480 COV03325 484009-048010 Condensate PMP01587 CPK2 PMP01586 CPK1 PMP01588 CPK3 PMP01589 CPK4
Pump Kit
Condenser Air RemovalTo exhaust the warm condenser air above the work area, attach the warm air flange and duct to the top of the unit. When using MovinCool inside anoffice, simply replace the ceiling tile with the MovinCool ceiling tile and insert the duct to exhaust the warm air. No special tools or equipment arerequired for the installation.
# PART NAME CLASSIC 10 CLASSIC 18 CLASSIC PLUS 14 CLASSIC PLUS 26
Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN
5 Warm Air Flange FLG01056 481170-0190 FLG01056 481170-0190 FLG01056 481170-0190 FLG01056 481170-01906 Warm Air Duct DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-00607 Ceiling Tile PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-8280
Make-Up AirWhen balanced air flow is required, attach the air plenum with a duct from the side of the unit to an outside air source. The air to the condenser ispulled from outside the room to eliminate problems associated with negative air pressure.
# PART NAME CLASSIC 10 CLASSIC 18 CLASSIC PLUS 14 CLASSIC PLUS 26
Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN
6 Air Duct DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-0060 DUC01043 481744-00607 Ceiling Tile PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-8280 PLT03642 LA146373-82808 Air Plenum KIT07912 LAY84270-0040 KIT07910 LAY84270-0020 KIT07910 LAY84270-0020 KIT07911 LAY84270-0030
Remote CoolingThe amount of air supplied to remote areas can be quickly and conveniently increased by attaching 10 ft extension ducts directly over the standardducts. For more permanent installations, use the flange and clamp to secure the extension ducts to the unit. Each duct can be extended 30 to 60 ftfrom the unit, depending on the model. Add trim rings to the end of the extension ducts to give a finished look and keep the ducts from unraveling.The dual duct accessory can be used to divide each 5 in. nozzle opening into two 4 in. outlets to multiply your cooling options.
# PART NAME CLASSIC 10 CLASSIC 18 CLASSIC PLUS 14 CLASSIC PLUS 26
Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN Trane PN MovinCool PN
1 Cold Air Flange FLG01055 481170-0180 FLG01055 481170-0180 FLG01055 481170-0180 FLG01058 481170-02502 Extension Duct DUC01044 481744-0090 DUC01044 481744-0090 DUC01044 481744-0090 DUC01041 481744-00303 Trim Ring RNG01760 481851-0200 RNG01760 481851-0200 RNG01760 481851-0200 RNG01761 481851-02104 Dual Duct DUC01045 484209-0030 DUC01045 484209-0030 DUC01045 484209-0030 N/A N/A
Auto CondensateRemoval
Condenser AirRemoval Remote Cooling Make-Up Air
RSP-SLB066-EN
MovinCool Classic/Classic Plus Series
Part Descriptions for MovingCool Classic/Classic Plus
1 Cold Air Flange 5 in. or 6 in. diameter white metal flange with wire clamp and mounting screws.
2 Cold Air Extension Duct 5 in. or 6 in. diameter white plastic duct that extends from 6 1⁄2 ft to 10 ft in length.
3 Trim Ring 5 in. or 6 in. diameter black plastic ring mounts as end caps for extension ducts.
4 Dual Duct 5 in. diameter white plastic flange with two 4 ft nozzles that extend to 3 1⁄2 ft in length.
5 Warm Air Flange 12 in. diameter gray metal flange with wire clamp and mounting screws.
6 Warm Air Duct 12 in. adjustable diameter white plastic duct that extends from 6 1⁄2 ft to 10 ft in length.
7 Ceiling Tile 24 in. x 24 in. white tile with 12 in. hole for warm air duct.
8 Air Plenum White plastic plenum, hinged for filter cleaning.
9 Cover Plate Blue metal plate covers condensate collection area.
10 Condensate Pump Kit 110V or 220V pump kit includes 3⁄8 in. diameter x 20 ft length hose and installation hardware.
RSP-SLB066-EN
Accessories
Classic & Classic Plus Specs
DENSO SALES CALIFORNIA, INC.REGISTERED TO ISO 9002
FILE NO. A5537
All specifications subject to change without notice. Standard warranty includes 12 months on entire unit. All models are UL listed and feature compressor overload relay and fan motorprotection. All models also feature compressor short-cycle protection, return air thermostat, automatic restart and accommodate a condensate pump kit. All models are 50 Hertz (Hz)compatible with a slight performance decrease from specifications listed above.
©2002 DENSO SALES CALIFORNIA, INC.MovinCool is a registered trademark
of DENSO Corporation.
Classic 18
UNT00864
MechanicalMechanical18,000 Btu/h
1 Phase, 208/230V2.1 kW10.8/10.0 amps15 amps6–15187–2530.35 kWCentrifugal530 CFM0.52 IWGCentrifugal1180 CFM0.25 IWGHermetic Rotary1.1 kW1.59 lb19 x 26 x 41 in167/200 lb14 AWG (3-core)6 ft5 gal68°–105°F50 ft60 ft63 dB67 dB
Electronic Features
Cooling Capacity
Electrical
Characteristics
Fans
Evaporator
Condenser
Compressor
R-22 Charge
Dimensions
Net Weight/Shipping Weight
Power Cord
Condensate Tank Capacity
Operating Conditions
Max. Duct Length
Max. Sound Level
Classic Plus 14
UNT00861
ElectronicElectronic14,000 Btu/h
1 Phase,115V1.3 kW12.3 amps15 amps5–15104–1260.24/0.19 kWCentrifugal440/380 CFM0.31 IWGCentrifugal880/760 CFM0.19 IWGHermetic Rotary0.8 kW1.5 lb19 x 26 x 41 in153/195 lb14 AWG (3-core)10 ft5 gal70°–115°F30 ft60 ft57/55 dB60/58 dB
MovinCool PN
Trane PN
Control Panel
Thermostat Control(Btu/h) Rating conditions: 95°F at 60% RHVoltage RequirementTotal Power ConsumptionCurrent ConsumptionRecommended Fuse SizeNEMA Plug ConfigurationMin.–Max. VoltageMotor Output–high/lowFan TypeMax. Air Flow–high/lowMax. External Static PressureFan TypeMax. Air flow–high/lowMax. External Static PressureTypeOutput
W x D x H
GaugeLength
Min.–Max. (@ 50% RH)Per Cold Duct Hose Hot Duct HoseWith Condenser Duct–high/lowWithout Condenser Duct–high/low
Classic Plus 26
UNT00862
ElectronicElectronic26,000 Btu/h
1 Phase, 208/230V3.1 kW15.6/14.0 amps20 ampsL6–20187–2530.55/0.38 kWCentrifugal708/600 CFM0.54 IWGCentrifugal1680/1460 CFM0.25 IWGHermetic Scroll1.6 kW1.87 lb19 x 29 x 47 in235/265 lb12 AWG (3 core) 6 ft5 gal70°–115°F60 ft45 ft66/64 dB69/67 dB
Classic 10
UNT00863
MechanicalMechanical10,000 Btu/h
1 Phase,115V1.1 kW10.6 amps15 amps5–15104–1260.14 kWCentrifugal270 CFM0.33 IWGCentrifugal740 CFM0.13 IWGHermetic Rotary0.6 kW1.15 lb19 x 26 x 41 in145/170 lb14 AWG (3-core)6 ft5 gal68°–105°F40 ft60 ft55 dB58 dB
RSP-SLB066-EN
Literature Order Number
Date
Supersedes
Stocking Location
Trane has a policy of continuous product and product data improvement and reserves the right to changedesign and specifications without notice.
The Trane Company
An American Standard Company
www.trane.com
For more information contactyour local district office ore-mail us at [email protected]
RSP-SLB066-EN
February 2002
New