LightningMaster Corporation · Best Available Technology Meets API 545, NFPA 780, and IEC 62305 Standards requirements for bypass conductors · Safe insulated conductor, and no metal on metal friction Eliminates risk of arcing between moving and fixed components · Unsurpassed Durability UV and thermal protected cable rated for use from <50 degrees f to >100 degrees f · Low Maintenance, nothing to break Simple gravity powered design, no spring loaded parts or retracting reels · Highest quality components 300 series stainless steel base, fiber glass arm · Manufactured in-house Lightning Master Corporation, USA · Patent Pending Extensive research and development, and product testing result in highest quality system Contact us at: 1-800-749-6800 | [email protected] | www.lightningmaster.com LightningMaster Corporation MAGS Bonding for Floating Roof Tanks Lightning Master is a full service, full spectrum static solutions and lightning and transient protection company serving the oil and gas and chemical industries since 1984. Our complete line of products and systems is backed by our world- wide support and customer service. Lightning Master is the global leader in lightning and static protection Moveable Arm Grounding System

Transcript of Moveable Arm Grounding System - PROTEGO · 2017. 8. 30. · Meets API 545, NFPA 780, and IEC 62305...

  • LightningMasterCorporation

    · Best Available Technology Meets API 545, NFPA 780, and IEC 62305 Standards requirements for bypass conductors

    · Safe insulated conductor, and no metal on metal friction Eliminatesriskofarcingbetweenmovingandfixedcomponents

    · Unsurpassed Durability UV and thermal protected cable rated for use from 100 degrees f

    · Low Maintenance, nothing to break Simple gravity powered design, no spring loaded parts or retracting reels

    · Highest quality components 300seriesstainlesssteelbase,fiberglassarm

    · Manufactured in-house Lightning Master Corporation, USA

    · Patent Pending Extensiveresearchanddevelopment,andproducttestingresultin

    highest quality system

    Contact us at: 1-800-749-6800 | [email protected] | www.lightningmaster.com

    LightningMasterCorporation

    MAGS

    Bonding forFloating Roof Tanks

    Lightning Master is a full service, full spectrum static solutions and lightning and transient protection company serving the oil and gas and chemical industries since 1984. Our complete line of products and systems is backed by our world-

    wide support and customer service. Lightning Master is the global leader in lightning and static protection

    Moveable Arm Grounding System

  • Contact us at: 1-800-749-6800 | [email protected] | www.lightningmaster.com

    LightningMasterCorporation

    Bonding forFloating Roof Tanks

    LightningMasterCorporation

    DIFFICULTY OFLOOSE CABLE

    BENEFITS OF MOVEABLE ARM

    LIGHTNING MASTERis a full service, full spectrum static solutions and light-ning and transient protection company serving the oil and gas and chemical industries since 1984. Our complete line of products and systems is backed by our worldwide support and customer service. Lightning Mas-ter is recognized internationally as the industry leader in lightning and static protection.

    Unparalleled Customer Service

    COMMITTEE PARTICIPATION

    Site Survey and Evaluation · System DesignProducts · Customer Service

    NFPA 780 API 545

    NFPA 781 IEEE 1576

    Loose cable can create a high-impedance path for current,

    increasing the risk for arching

    Cable can tangle and interfere with proper roof operations

    Cable can tangle and break, eliminating the electrical connection

    Stainless steel base, light glass reinforced plastic arm keeps

    cable from tangling

    Gravity powered design,no spring loaded parts

    or moving reels

    UV and thermal protected cable

    About 30% of tank fire and explosion incidents are due to lightning. EFR tanks are particularly vulnerable to the effects of lightning because of the iso-latedfloating roof. Adirector nearby lightning strike will cause a difference in potential between the float-ing roof and the tank shell, which, if not properly bonded canbeanignitionsource.