MOUSE / RAT EUTHANASIA INSTRUCTIONS...EUTHANASIA INSTRUCTIONS For more detailed step-by-step...
Transcript of MOUSE / RAT EUTHANASIA INSTRUCTIONS...EUTHANASIA INSTRUCTIONS For more detailed step-by-step...
-
Updated 7.10.2020
MOUSE / RATEUTHANASIA
INSTRUCTIONSFor more detailed step-by-step instructions, please refer to the
Guidelines for Rats & Mice Euthanasia Procedures for Investigative Personnel(az.research.umich.edu/node/1016)
In-House CO2 Setup
https://animalcare.umich.edu/https://az.research.umich.edu/node/1016
-
7.10.
2020
REMEMBER, IF CONSOLIDATING ANIMALS FOR EUTHANASIA:
No more than 10 mice in a standard mouse (#1) cageor 25 mice in a large mouse / small rat (#3) cage
Follow standard housing densities when consolidatingother rodents (e.g. rats) for euthanasia
Provide ample space for animals to move and assumenormal postures if using your own euthanizing chamber
Start the procedure no more than 10 minutesafter the animals have been consolidated
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
01STEP7.10.20
20
The flow meter (1) should be at zero
The supply valve (2) and flow meter (3)should be turned o� (all the way clockwise)
3
1
1
2
3
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
02STEP
Insert the CO2 hose through thewater bottle grommet on the cage lid
ORthrough the lixithole
in the back of the cage
MOUSE – SMALL RAT CAGE
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
03STEP
Turn supply valve (1) to the leftor counterclockwise to turn on the CO2
1
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
04STEP
Until the gauge (floating black ball)(2) reaches the desired color line
Adjust CO2 flow into the cageby turning regulator knob (1) slowly
BLACK is for RAT #3 cages
GREEN is forLARGE MOUSE #3 cages
BLUE is forSMALL MOUSE #1 cages
INSET
1
2
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
05STEP
Allow gas to flow until animalsare no longer moving or breathing
You MUST remain with your animals untildeath is confirmed by a secondary means
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
06STEP
Note that gauge (2)is falling back to zero now
Turn o� the CO2 supply valve (1)
1
2
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
07STEP
Gauge should now be set at zerowith no more CO2 flowing
After gauges reach zero, ensure flow meter valve (1) is shut o� by turning it clockwise until snug
Do NOT overtighten
INSET
seepicture inset
1
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
08STEP
Check your protocol for approvedsecondary euthanasia method
ALWAYS perform a secondary, physical method to ensure euthanasia is e�ective
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
09STEP
After you have confirmed deathby a secondary, physical means
Put carcass in a glove or opaque bag
Label with PI name, date, and nameof individual conducting euthanasia
DATE:
PI NAME:
INDIVIDUAL:or
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
7.10.
2020
Place in appropriate binwithin carcass cooler
10STEP
MOU
SE /
RAT E
UTHA
NASI
A IN
STRU
CTIO
NS –
IN-H
OUSE
CO2
SET
UP
-
We want to acknowledge that the ethical cost of using animals in researchmay cause some individuals emotional distress, especially if they perform euthanasia
as part of their occupational/research duties.
If you think you may be struggling with what is commonly referred to as“compassion fatigue,” there are resources that can help.
Visit animalcare.umich.edu/cap or email [email protected] learn more about our Compassion Awareness Project.
QUESTIONS?Contact your ULAM Faculty Veterinarian and/or
your facility’s ULAM Husbandry Supervisor
Bookmark and review therodent euthanasia guidelines on Animal Care A-Z
(az.research.umich.edu/node/1016)
https://animalcare.umich.edu/https://az.research.umich.edu/node/1016mailto:[email protected]://animalcare.umich.edu/cap