Most Frequently CitedSerious Violations
Construction – FY 2004
![Page 2: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/2.jpg)
Number of Serious Violations - FY 2004 2
1660
1374
1353
1232
980
935
907
892
851
802
501(b)(1) - M
501(b)(13) - M
100(a) - E
451(g)(1) - L
451(e)(1) - L
453(b)(2)(v) - L
652(a)(1) - P
451(b)(1) - L
503(a)(1) - M
1053(b)(1) - X
Most Frequently Cited Serious Violationsin Construction – FY 2004
Fall hazards training program
Head protection
Scaffolds - Platform construction
Excavations - Protection of employees
Aerial lifts – Body belt & lanyard
Scaffolds - Fall protection
Fall protection - Unprotected sides & edges
Fall protection – Residential construction 6’ or more
Portable ladders 3 feet above landing surface
Scaffolds - Access
Sta
nd
ard
& S
ub
part
- 1
92
6.
--
There were also 400 Section 5(a)(1) violations cited in construction SIC codes during this period.
![Page 3: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/3.jpg)
Number of Serious Violations - FY 2004 3
766
586
415
193
89
21(b)(2)
20(b)(2)
20(b)(1)
25(a)
28(a)
Sta
nd
ard
- 1
92
6.
Subpart C - General Safety & Health(1926.20 - 35)
Employee training programs
Inspections by competent person
Initiate and maintain accident prevention programs
Personal protective equipment – Employer responsibility
Housekeeping
![Page 4: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/4.jpg)
Number of Serious Violations - FY 2004 4
Subpart D - Occupational Health & Environmental Controls
(1926.50 - 66)
58
46
46
38
29
62(d)(1)(i)
50(c)
55(a)
55(b)
62(d)(1)(iii)
Sta
nd
ard
- 1
92
6.
Gases, vapors, fumes, dusts & mists - Employee exposure
Lead - Exposure assessment
First aid training
Lead – Representative personal sampling
Gases, vapors, etc. – Administrative/Engineering controls
![Page 5: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/5.jpg)
Number of Serious Violations - FY 2004 5
Subpart E - Personal Protective & Life Saving Equipment
(1926.95 - 107)
1353
548
286
14
13
100(a)
102(a)(1)
95(a)
106(a)
106(d)
Sta
nd
ard
- 1
92
6.
Head protection
Lifesaving skiff for employees working over water
PPE - Provided, used and maintained
Eye and face protection
Life jackets/vests
![Page 6: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/6.jpg)
Number of Serious Violations - FY 2004 6
Subpart F - Fire Protection & Prevention(1926.150 - 159)
36
30
23
17
17
150(c)(1)(i)
150(c)(1)(vi)
153(o)
150(a)(1)
150(c)(1)(iv)
Sta
nd
ard
- 1
92
6. Extinguishers within 50 ft. of flammables/combustibles
2A fire extinguishers - Building area
Fire protection program
LP-Gas systems – Protection from vehicular traffic
Extinguishers on each floor
![Page 7: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/7.jpg)
Number of Serious Violations - FY 2004 7
60
35
35
20
7
200(g)(1)
200(g)(2)
201(a)
202
200(a)
Sta
nd
ard
- 1
92
6.
Subpart G - Signs, Signals & Barricades(1926.200 - 203)
Traffic control signs/devices - Requirements
Barricades - Requirements
Flaggers – Proper signaling by and use of
Traffic signs at points of hazard
Visible signs and symbols
![Page 8: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/8.jpg)
Number of Serious Violations - FY 2004 8
Subpart H - Materials Handling, Storage, Use & Disposal
(1926.250 - 252)
33
20
18
13
12
251(a)(1)
251(a)(6)
252(a)
251(e)(8)(iii)
251(e)(8)
Sta
nd
ard
- 1
92
6.
Rigging equipment inspection & removal from service
Torn/cut synthetic web slings - Removal from service
Slings – Daily inspections
Exterior drop chutes
Unsafe synthetic web slings – Removal from service
![Page 9: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/9.jpg)
Number of Serious Violations - FY 2004 9
Subpart I - Tools: Hand & Power(1926.300 - 307)
88
85
39
37
33
304(f)
300(b)(1)
304(i)(1)
300(b)(2)
304(d)
Sta
nd
ard
- 1
92
6.
Woodworking tools - ANSI requirements
Guarding of rotating/moving parts
Tools designed for guards - Guards in place
Guarding of circular saws
Guarding of circular hand-fed ripsaws
![Page 10: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/10.jpg)
Number of Serious Violations - FY 2004 10
Subpart J - Welding & Cutting(1926.350 -354)
91
75
30
24
23
350(a)(9)
350(a)(10)
350(a)(1)
350(h)
352(d)
Sta
nd
ard
- 1
92
6.
Cylinders secured upright
Fire extinguishing equipment in area
Oxygen cylinder storage
Valve protection caps
Regulators/Gauges in working order
![Page 11: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/11.jpg)
Number of Serious Violations - FY 2004 11
Subpart K - Electrical(1926.400 - 449)
349
328
215
190
159
404(b)(1)(i)
404(f)(6)
403(b)(2)
404(b)(1)(ii)
405(g)(2)(iv)
Sta
nd
ard
- 1
92
6.
Branch circuits - Ground fault protection/Assured equipment grounding conductor program
Grounding path
Equipment installation and use
Ground-fault circuit interrupters
Flexible cords – Strain relief
![Page 12: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/12.jpg)
Number of Serious Violations - FY 2004 12
Subpart L - Scaffolds(1926.450 - 454)
1232
980
935
892
649
451(g)(1)
451(e)(1)
453(b)(2)(v)
451(b)(1)
454(a)
Sta
nd
ard
- 1
92
6.
Scaffolds above 10 ft. - Fall protection
Scaffold access
Scaffold platform construction
Aerial lifts - Body belt and lanyard
Training for employees using scaffolds
![Page 13: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/13.jpg)
Number of Serious Violations - FY 2004 13
1660
1374
851
465
286
501(b)(1)
501(b)(13)
503(a)(1)
501(b)(10)
501(b)(11)
Sta
nd
ard
- 1
92
6.
Subpart M - Fall Protection(1926.500 - 503)
Fall protection - Residential construction 6’ or more
Fall hazards training program
Fall protection - Unprotected sides & edges
Fall protection - Roofing work on low-slope roofs
Fall protection – Steep roofs
![Page 14: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/14.jpg)
Number of Serious Violations - FY 2004 14
29
25
21
18
16
550(a)(15)(i)
550(a)(9)
550(a)(6)
550(b)(2)
550(a)(1)Sta
nd
ard
- 19
26.
Subpart N - Cranes, Derricks, Hoists, Elevators & Conveyors
(1926.550 - 556)
Crawler, locomotive, & truck cranes - ANSI B30.5-1968
Cranes and derricks – Manufacturers’ specifications
Hoisting machinery – Annual inspection
Clearances between power lines and equipment
Swing radius at rear of crane barricaded
![Page 15: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/15.jpg)
Number of Serious Violations - FY 2004 15
Subpart O - Motor Vehicles, Mechanized Equipment, & Marine Operations
(1926.600 - 606)
70
56
34
28
27
602(c)(1)(vi)
602(a)(9)(ii)
602(a)(2)(i)
602(c)(1)(viii)(A)
602(a)(9)(i)
Sta
nd
ard
- 1
92
6.
Earthmoving/compacting equipment - Reverse signal alarm
Bi-directional machines - Horn
Seat belts
Lifting/hauling equipment - Use of safety platform
Industrial trucks - ANSI B56.1-1969
![Page 16: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/16.jpg)
Number of Serious Violations - FY 2004 16
Subpart P - Excavations(1926.650 - 652)
107
370
394
461
907652(a)(1)
651(c)(2)
651(k)(1)
651(j)(2)
651(k)(2)
Sta
nd
ard
- 1
92
6.
Employee protection in excavations - Protective system use
Inspections by competent person
Protection from falling/rolling materials/equipment
Egress from trench excavations
Competent person inspection - Employees removed from hazard
![Page 17: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/17.jpg)
Number of Serious Violations - FY 2004 17
Subpart Q - Concrete & Masonry Construction(1926.700 - 706)
248
24
15
701(b)
706(b)
706(a)(1)
Sta
nd
ard
- 1
92
6.
Reinforcing steel - Guarding
Masonry walls - Bracing
Masonry walls – Limited access zone prior to start
![Page 18: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/18.jpg)
Number of Serious Violations - FY 2004 18
Subpart R – Steel Erection(1926.750 - 761)
285
45
37
15
12
12
760(a)(1)
761(b)
760(b)(3)
760(b)(1)
752(b)
755(a)(1)
Sta
nd
ard
- 1
92
6.
Protection from fall hazards
Written notification prior to steel erection
Fall protection for connectors – 15’ to 30’
Fall hazard training
Fall protection for connectors – More than 2 stories or 30’
Columns anchored by anchor rods
![Page 19: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/19.jpg)
Number of Serious Violations - FY 2004 19
48
9
7
6
6
850(a)
850(i)
851(b)
850(g)
852(e)
Sta
nd
ard
- 1
92
6.
Subpart T - Demolition(1926.850 - 860)
Engineering survey - Prior to operations
Stairs, passageways, ladders – Inspected and maintained
Chute openings protected
Floor openings covered
Wall openings protected
![Page 20: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/20.jpg)
Number of Serious Violations - FY 2004 20
Subpart X - Ladders(1926.1050 - 1060)
Stairrails & handrails
802
281
207
201
171
1053(b)(1)
1052(c)(1)
1053(b)(4)
1060(a)
1053(b)(13)
Sta
nd
ard
- 1
92
6.
Portable ladders 3 feet above landing surface
Top of stepladder not to be used as a step
Training program
Appropriate use of ladders
![Page 21: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/21.jpg)
Number of Serious Violations - FY 2004 21
Subpart Z - Toxic & Hazardous Substances(1926.1100 - 1152)
30
23
19
14
11
11
11
1101(f)(2)(i)
1101(e)(1)
1101(i)(1)
1101(k)(9)(i)
1101(f)(1)(i)
1101(g)(1)(i)
1101(g)(1)(ii)
Sta
nd
ard
- 1
92
6.
Asbestos - Exposure assessment by competent person
Asbestos - Class I, II, & III asbestos work in regulated areasAsbestos - Protective clothingAsbestos - Training program
Asbestos - Monitoring
Asbestos – Vacuum cleaners with HEPA filtersAsbestos – Wet methods or wetting agents
![Page 22: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/22.jpg)
Number of Serious Violations - FY 2004 22
63
62
36
36
22
134(e)(1)
134(c)(1)
134(d)(1)(iii)
134(f)(2)
134(f)(1)
Respiratory Protection (1910.134)Cited in Construction SIC Codes
Medical evaluation to determine employee’s ability to use respirator
Fit testing prior to initial use and annually
Evaluation of respiratory hazards
Qualitative or quantitative fit testing
Written respiratory protection program
Sta
nd
ard
: 19
10.
![Page 23: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/23.jpg)
Number of Serious Violations - FY 2004 23
118
21
14
5
178(l)(1)(i)
178(l)(6)
178(l)(1)(ii)
178(l)(4)(iii)
Powered Industrial TruckOperator Training [1910.178(l)]Cited in Construction SIC Codes
Training prior to truck operation
Evaluation of operator once every 3 years
Operator certification
Sta
nd
ard
: 19
10.
Operator competency
![Page 24: Most Frequently Cited Serious Violations Construction – FY 2004.](https://reader034.fdocuments.in/reader034/viewer/2022042607/551407dc550346d8488b4c20/html5/thumbnails/24.jpg)
Number of Serious Violations - FY 2004 24
Hazard Communication (1910.1200)Cited in Construction SIC Codes
168
63
62
59
56
1200(e)(1)
1200(g)(1)
1200(g)(8)
1200(h)(1)
1200(h)
Written program
Information and training
Material Safety Data Sheets readily accessible
Training initially and for new hazards
Material Safety Data Sheets
Sta
nd
ard
: 19
10.