Accessories WIKA data sheet AC 09.17 Page 1 of 10 WIKA data sheet AC 09.17 03/2019 Monoflange Process and instrument version Model IVM Applications Shut-off and venting of pressure measuring instruments Flange connection of instruments with threaded connections to pipelines or vessels For aggressive liquids, gases and vapours, also in aggressive environments Oil and gas industry, chemical and petrochemical industries, power plants, primary metals Special features Compact design with low number of potential leakage points reduces overall weight Threaded mounting of bonnets not wetted to avoid seizure and leaks Smooth valve actuation, even under high pressure, leads to fault-free operation and long service life Metal valve seat with leak-tested tightness in accordance with BS6755 / ISO 5208 leakage rate A Instrument version for “fugitive emissions” according to TA-Luft and ISO 15848-1 Description Due to its one-piece design, the model IVM monoflange can withstand high overpressures. It ensures a robust and compact mounting of the measuring instrument directly to the process flange. The use of metal and graphite seals allows working at high temperatures. In combination with pressure measuring instruments, diaphragm seals or level measuring instruments, the valves are suitable for use in critical applications like refineries or steam generation systems. The IVM can be used for “fugitive emissions” in chemical applications or for processes with critical gases. The bubble-tight leak-tested metal seat makes these valves perfectly suitable for sour gases and natural gas processing or nitrogen production plants. The super-finished machining of the internal parts, such as spindle and spindle tip, allows a very smooth and precise operation, even at high pressures, and avoids leaks or seizure of the valve. The OS&Y bonnet has been specifically developed in accordance with the highest international standards for the direct mounting of IVM monoflanges on pipelines or vessels. WIKA offers the professional assembly of different instruments and valves into ready-to-install hook-up solutions. Fig. left: Instrument version Fig. right: Process version with OS&Y bonnet Data sheets showing similar products: Block-and-bleed valve, 2-valve manifold; models IV20 and IV21; see data sheet AC 09.19 Valve manifold for differential pressure measuring instruments, models IV30, IV31, IV50 and IV51; see data sheet AC 09.23

Transcript of Monoflange Process and instrument version Model IVM · Smooth valve actuation, even under high...

  • Accessories

    WIKA data sheet AC 09.17

    Page 1 of 10WIKA data sheet AC 09.17 ∙ 03/2019

    MonoflangeProcess and instrument versionModel IVM

    Applications

    ■ Shut-off and venting of pressure measuring instruments ■ Flange connection of instruments with threaded

    connections to pipelines or vessels ■ For aggressive liquids, gases and vapours, also in

    aggressive environments ■ Oil and gas industry, chemical and petrochemical

    industries, power plants, primary metals

    Special features

    ■ Compact design with low number of potential leakage points reduces overall weight

    ■ Threaded mounting of bonnets not wetted to avoid seizure and leaks

    ■ Smooth valve actuation, even under high pressure, leads to fault-free operation and long service life

    ■ Metal valve seat with leak-tested tightness in accordance with BS6755 / ISO 5208 leakage rate A

    ■ Instrument version for “fugitive emissions” according to TA-Luft and ISO 15848-1

    Description

    Due to its one-piece design, the model IVM monoflange can withstand high overpressures. It ensures a robust and compact mounting of the measuring instrument directly to the process flange. The use of metal and graphite seals allows working at high temperatures.

    In combination with pressure measuring instruments, diaphragm seals or level measuring instruments, the valves are suitable for use in critical applications like refineries or steam generation systems. The IVM can be used for “fugitive emissions” in chemical applications or for processes with critical gases. The bubble-tight leak-tested metal seat makes these valves perfectly suitable for sour gases and natural gas processing or nitrogen production plants.

    The super-finished machining of the internal parts, such as spindle and spindle tip, allows a very smooth and precise operation, even at high pressures, and avoids leaks or seizure of the valve. The OS&Y bonnet has been specifically developed in accordance with the highest international standards for the direct mounting of IVM monoflanges on pipelines or vessels.

    WIKA offers the professional assembly of different instruments and valves into ready-to-install hook-up solutions.

    Fig. left: Instrument versionFig. right: Process version with OS&Y bonnet

    Data sheets showing similar products:Block-and-bleed valve, 2-valve manifold; models IV20 and IV21; see data sheet AC 09.19Valve manifold for differential pressure measuring instruments, models IV30, IV31, IV50 and IV51; see data sheet AC 09.23

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 2 of 10

    Specifications

    Monoflange, model IVMStandards used

    Design ■ ASME B16.5, pipe flanges and flange fittings ■ ASME B16.34, valves - flanged, threaded and welding end ■ ASME B1.20.1, pipe threads, general purpose (inch) ■ ASME B31.1, power piping ■ ASME B31.3, process piping ■ ISO 17292, metal ball valves for petroleum, petrochemical and allied industries ■ MSS SP-99, valves for measuring instruments

    Tests ■ API 598, valve inspection and testing ■ BS EN ISO 10497, type testing in accordance with fire safety requirements ■ ISO 5208, pressure testing of metallic valves with leakage rate A ■ MSS SP-61, pressure testing of valves ■ DIN EN 12266-1, pressure tests, test procedures and acceptance criteria for industrial valves

    Material requirements ■ NACE MR0175 / ISO 15156, use in H₂S-containing environments in oil and gas production ■ NORSOK M-630, specificaiton for use in pipelines (Norway)

    Marking MSS SP-25, marking on valvesFunction(for functional diagram, see next page)

    ■ Block (shut off)- 1 x bonnet for shutting off the process

    ■ Block and bleed (shut off and vent)- 1 x bonnet for shutting off the process- 1 x standard bonnet for venting

    ■ Double block and bleed (2 x shut off and 1 x vent)- 2 x bonnets for shutting off the process- 1 x standard bonnet for venting

    Version ■ Process version (with OS&Y bonnet on the process side) ■ Instrument version (with standard bonnet on the process side)

    Process connection(see page 8 ff.)

    ■ Flange ½" … 2" / class 150 … class 2500, following ASME B16.5 ■ Flange DN 15 … DN 25 / PN 16 … PN 100, following EN 1092-1

    Surface roughness Ra of the sealing faceFollowing ASME B16.5 ■ RF: 3.2 ... 6.3 μm [125 ... 250 μin] (spiral surface)

    ■ RJ: 1.6 μm [63 μin]Following EN 1092-1 ■ Form B1: 3.2 ... 6.3 μm [125 ... 250 μin]

    ■ Form B2: 0.8 ... 3.2 μm [32 ... 125 μin]Instrument connection(see examples on page 7)

    ■ 1 x ½" NPT female, axial ■ 1 x ½" NPT female, swivel adapter, axial ■ 2 x ½" NPT female, 1 x radial and 1 x axial 1) ■ 2 x ½" NPT female, 1 x swivel adapter, radial and 1 x axial 1) ■ Connecting flange

    Vent connection ■ Without ■ ¼ NPT female, plug screw is included in delivery, though not pre-fitted. ■ ½ NPT female, plug screw is included in delivery, though not pre-fitted.

    1) Axial and/or radial instrument connection can be used. Optionally, one measuring instrument connection can be closed with the supplied plug screw.

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 3 of 10

    Block (shut off) Block and bleed (shut off and vent)Functional diagram

    Colour code Blue: Shut offRed: Vent

    Double block and bleed (2 x shut off and 1 x vent)

    MaterialsWetted parts

    Flange ■ Stainless steel 316L (standard) ■ Duplex F51 (1.4462) ■ Super Duplex F55 (1.4501) ■ Hastelloy C276 (2.4819) ■ Monel 400 (2.4360) ■ Steel A350 LF2 (1.0566), galvanised carbon steel per ISO/EN 2081 1) 2)

    MonoflangeSpindle tip

    Sealing packing ■ PTFE ■ Graphite ■ RTFE

    Reinforced PTFE, material for optional certificate „Emission protection in accordance with TA-Luft (VDI 2440) and ISO-15848-1

    Non-wetted partsGland packing, gland nut, yoke, valve spindle, seal bush, threaded bolt with nut

    Stainless steel 316L

    Handle ■ Stainless steel ■ Stainless steel 316/316L

    1) Lacquered version on request2) Flange from steel A350 LF2 (1.0566), bonnet and spindle tip from stainless steel 316/316L

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 4 of 10

    Anti-tamper version with padlockAnti-tamper versionBonnet options

    Standard

    T-bar handle

    Coloured dust cap

    Gland nut

    Valve spindle

    Seal bush

    Sealing packing

    Bonnet bodySpindle tip

    Bonnet versions

    OS&Y

    Sealing ring

    T-bar handle

    Blue dust cap

    Gland packing

    Valve spindleSeal bushSealing packing

    Bonnet body

    Spindle tipSealing ring

    Threaded bolt with nut

    Yoke

    Specification Standard bonnet OS&Y bonnetStandards complied with ■ ASME VIII div. 1 and MSS SP-99

    ■ TA-Luft (VDI 2440) and ISO-15848-1 (option) ■ ASME VIII div. 1 and ASME B31.1, ASME B31.3 ■ API 607, ISO 10497, BS 6755-2

    Dust cap colour code Blue: Shut offRed: Vent

    Spindle tip Non-rotating, low-wear, blow-out-safeValve seat Metal-to-metal, back seat designValve bore size 5 mm [0.197 in]

    1) The anti-tamper key is not included in delivery of the anti-tamper version, but available as accessory.

    Anti-tamper key

    1)

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 5 of 10

    Material of the sealing packing

    Max. permissible operating pressure in bar at temperature in °C

    Max. permissible operating pressure in psi at temperature in °F

    PTFE 690 bar at 38 °C 10,000 psi at 100 °F276 bar at 204 °C 4,000 psi at 400 °F

    Graphite 420 bar at 38 °C 6,000 psi at 100 °F209 bar at 538 °C 3,030 psi at 1.000 °F

    RTFE 1) 420 bar at 38 °C 6,000 psi at 100 °F276 bar at 180 °C 4,000 psi at 356 °F

    1) Reinforced PTFE, material for optional certificate „Emission protection in accordance with TA-Luft (VDI 2440) and ISO-15848-1

    The minimum design temperature is -54 °C [-65 °F].For continuously low operating temperatures ≤ -54 °C [≤ -65 °F] a special design is needed.

    Pressure-temperature diagramPr

    essu

    re in

    bar

    (psi

    )

    Temperature in °C (°F)

    PTFEGraphiteRTFE 1)

    0

    100(1450)

    200(2901)

    300(4351)

    400(5802)

    500(7252)

    600(8702)

    700(10153)

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 6 of 10

    Installation examples

    Instrument monoflanges are, as shown, installed behind an initial shut-off device. Process monoflanges are designed with an OS&Y bonnet for the process-side shut-off. The broad design of the passage geometries of the OS&Y bonnet prevents clogging through particle accumulation. With the use of process monoflanges, the purchase of traditional shut-off devices can be saved.

    Instrument versionHorizontal flange arrangement

    Process versionHorizontal flange arrangement

    Vertical flange arrangementVertical flange arrangement

    The monoflange assembly enables the integration of up to three bonnets with compact dimensions. Flange connections are advantageous for frequent maintenance and service operations and for applications with hazardous media.

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 7 of 10

    Examples for process connection and instrument connection

    Process and instrument connection: Flange Process connection: FlangeInstrument connection: Swivel adapter, axial

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 8 of 10

    Model IVM, process version

    DN Class Dimensions in mm [in] x 1) Weight kg [lb]

    A B C Ø D E for RF E for RJ F

    ½" 150 100 [3.94] 96 [3.78] 113 [4.45] 88.9 [3.5] 50.6 [2] - 40 [1.57] 4 0.7 [1.45]½" 300/600 103.2 [4.06] 99.3 [3.91] 116.8 [4.60] 95.2 [3.75] 55.4 [2.18] 54.5 [2.15] 4 0.8 [1.8]½" 900/1500 116 [4.57] 112.3 [4.42] 131.4 [5.17] 120.6 [4.75] 55.4 [2.18] 55.4 [2.18] 4 1.3 [2.95]½" 2500 121 [4.76] 117 [4.61] 138.5 [5.45] 133.3 [5.25] 55.4 [2.18] 55.4 [2.18] 4 1.7 [3.71]¾" 150 105 [4.13] 101 [3.98] 118.8 [4.68] 98.4 [3.87] 50.6 [2] - 4 0.9 [1.9]¾" 300/600 115 [4.53] 110.8 [4.36] 129.6 [5.10] 117.5 [4.62] 55.4 [2.18] 55.4 [2.18] 4 1.3 [2.8]¾" 900/1500 121 [4.76] 117 [4.61] 136.7 [5.38] 130.2 [5.12] 55.4 [2.18] 55.4 [2.18] 4 1.6 [3.5]¾" 2500 122 [4.80] 118 [4.65] 142 [5.59] 139.7 [5.5] 55.4 [2.18] 55.4 [2.18] 4 1.9 [4.2]1" 150 109.8 [4.32] 106 [4.17] 124.2 [4.89] 107.9 [4.25] 50.6 [2] 55.4 [2.18] 4 1.1 [2.4]1" 300/600 118 [4.65] 114 [4.49] 133 [5.24] 123.8 [4.87] 55.4 [2.18] 55.4 [2.18] 4 1.5 [3.3]1" 900/1500 130.8 [5.15] 127 [5] 147 [5.79] 149.2 [5.87] 55.4 [2.18] 55.4 [2.18] 4 2.1 [4.7]1" 2500 135.6 [5.34] 132 [5.20] 152 [5.98] 158.7 [6.25] 55.4 [2.18] 55.4 [2.18] 4 2.5 [5.5]1 ½" 150 119.5 [4.70] 115.6 [4.55] 135 [5.31] 127 [5] 50.6 [2] 55.4 [2.18] 4 2.4 [5.3]1 ½" 300/600 134 [5.28] 130 [5.12] 150.2 [5.91] 155.6 [6.12] 55.4 [2.18] 55.4 [2.18] 4 2.4 [5.3]1 ½" 900/1500 146.5 [5.77] 142.6 [5.61] 163 [6.42] 177.8 [7] 55.4 [2.18] 55.4 [2.18] 4 3.2 [7.1]1 ½" 2500 158 [6.22] 154 [6.06] 174.7 [6.88] 203.2 [8] 55.4 [2.18] 56.9 [2.24] 4 5.4 [11.8]2" 150 132.5 [5.22] 128.6 [5.06] 148.7 [5.85] 152.4 [6] 50.6 [2] 55.4 [2.18] 4 2.4 [5.2]2" 300/600 138.9 [5.47] 135 [5.31] 155.5 [6.12] 165.1 [6.5] 55.4 [2.18] 56.9 [2.24] 8 2.8 [6.1]2" 900/1500 164.6 [6.48] 161 [6.34] 182 [7.17] 215.9 [8.5] 55.4 [2.18] 56.9 [2.24] 8 4.8 [10.5]2" 2500 174 [6.85] 170.2 [6.70] 191.5 [7.54] 234.9 [9.25] 66.2 [2.61] 67.7 [2.67] 8 7.1 [15.7]

    1) Number of screws

    Flange connection per ASME B 16.5

    Plug screw for vent connection is included in delivery, though not pre-fitted.

    1432

    5853

    .01

    1432

    5848

    .01

    1432

    5839

    .01

    1432

    5842

    .01

    Double block and bleed, up to DN 2" Class 150

    Monoflange design from DN 2" Class 300 and higher

    Block

    Block and bleed, up to DN 2" Class 150

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 9 of 10

    DN Class Dimensions in mm [in] x 1) Weight kg [lb]

    A B Ø D E for RF E for RJ F

    ½" 150 99.9 [3.9] 96 [3.7] 88.9 [3.5] 40.6 [1.6] -. 30 [1.2] 4 0.5 [1.15]½" 300/600 103.2 [4.1] 99.3 [3.9] 95.2 [3.75] 45.3 [1.8] 44.5 [1.7] 30 [1.2] 4 0.5 [1.2]½" 900/1500 116.3 [4.6] 112.4 [4.4] 120.6 [4.75] 45.3 [1.8] 45.3 [1.8] 30 [1.2] 4 1 [2.2]½" 2500 122.8 [4.8] 118.9 [4.7] 133.3 [5.25] 45.4 [1.8] 45.4 [1.8] 30 [1.2] 4 1.3 [2.9]¾" 150 104.9 [4.1] 101 [3.9] 98.4 [3.87] 40.6 [1.6] - 30 [1.2] 4 0.7 [1.5]¾" 300/600 114.7 [4.5] 110.8 [4.4] 117.5 [4.62] 45.4 [1.8] 45.4 [1.8] 30 [1.2] 4 0.7 [1.5]¾" 900/1500 121.2 [4.8] 117.3 [4.6] 130.2 [5.12] 45.4 [1.8] 45.4 [1.8] 30 [1.2] 4 1.2 [2.7]¾" 2500 126 [4.9] 122.1 [4.8] 139.7 [5.5] 47.1 [1.8] 47.1 [1.8] 31.7 [1.25] 4 1.6 [3.5]1" 150 109.8 [4.3] 105.9 [4.2] 107.9 [4.25] 40.6 [1.6] 45.3 [1.8] 30 [1.2] 4 1 [2.1]1" 300/600 118 [4.6] 114 [4.5] 123.8 [4.87] 45.4 [1.8] 45.3 [1.8] 30 [1.2] 4 1.2 [2.6]1" 900/1500 130.9 [5.1] 127 [5.0] 149.2 [5.87] 45.4 [1.8] 45.4 [1.8] 30 [1.2] 4 1.6 [3.6]1" 2500 135.4 [5.3] 131.5 [5.2] 158.7 [6.25] 50.4 [2.0] 50.4 [2.0] 35 [1.4] 4 2.5 [5.5]1 ½" 150 119.6 [4.7] 115.7 [4.6] 127 [5] 40.6 [1.6] 45.4 [1.8] 30 [1.2] 4 1.4 [3]1 ½" 300/600 134 [5.3] 130 [5.1] 155.6 [6.12] 40.6 [1.6] 45.4 [1.8] 30 [1.2] 4 1.8 [4]1 ½" 900/1500 146.5 [5.8] 142.6 [5.6] 177.8 [7] 47.2 [1.9] 47.2 [1.9] 31.8 [1.2] 4 3.5 [7.7]1 ½" 2500 158.1 [6.2] 154.2 [6.1] 203.2 [8] 60.1 [2.3] 61.6 [2.4] 44.7 [1.76] 4 4.8 [10.6]2" 150 132.5 [5.2] 128.6 [5.1] 152.4 [6] 40.6 [1.6] 45.4 [1.8] 30 [1.2] 4 1.8 [3.9]2" 300/600 138.9 [5.5] 135 [5.3] 165.1 [6.5] 45.4 [1.8] 46.9 [1.85] 30 [1.2] 8 1.8 [4]2" 900/1500 164.6 [6.5] 160.7 [6.3] 215.9 [8.5] 53.5 [2.1] 55 [2.2] 38.1 [1.5] 8 4.7 [10.3]2" 2500 174 [6.85] 170.1 [6.7] 234.9 [9.25] 66.2 [2.6] 67.7 [2.7] 50.8 [2.0] 8 7.4 [16.3]

    1) Number of screws

    Model IVM, instrument version

    Flange connection per ASME B 16.5

    Plug screw for vent connection is included in delivery, though not pre-fitted.

    1432

    5430

    .01

    1432

    5434

    .01

    1432

    5447

    .01

    1432

    5450

    .01

    Double block and bleed, up to DN 2" Class 150

    Monoflange design from DN 2" Class 300 and higher

    Block

    Block and bleed, up to DN 2" Class 150

  • WIKA data sheet AC 09.17 ∙ 03/2019 Page 10 of 10

    © 03/2019 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.The specifications given in this document represent the state of engineering at the time of publishing.We reserve the right to make modifications to the specifications and materials.

    03/2

    019

    EN

    WIKA Alexander Wiegand SE & Co. KGAlexander-Wiegand-Straße 3063911 Klingenberg/GermanyTel. +49 9372 132-0Fax +49 9372 [email protected]

    Approvals

    Logo Description CountryEAC (option)Machinery directive

    Eurasian Economic Community

    - CRNSafety (e.g. electr. safety, overpressure, ...)

    Canada

    Manufacturer‘s information and certificates

    Logo Description- PMI 1) test certificate (option)

    Valve body- Certificate for oxygen versions (option)

    - Oil and grease free for oxygen per ASTM G93 level C- Sealing packing 2) and lubricants in accordance with BAM requirements- Limits of the permissible operating ranges for pressure and temperature:

    420 bar at 60 °C or 6,000 psi at 140 °F90 bar at 200 °C or 1,305 psi at 392 °F

    - Emission protection in accordance with TA-Luft (VDI 2440) and ISO-15848-1 (option) 3)- Tightness class: AH- Endurance class: C01- Temperature class: -29 ... +180 °C [-20 ... +356 °F]

    - Type tested for fire safety in accordance with API 607, ISO 10497, BS 6755-2 4)

    1) Positive material identification2) PTFE or graphite3) Only for standard bonnet4) Only for OS&Y bonnet

    Certificates

    ■ 3.1 inspection certificate per EN 10204- Material certificate for the valve body per NACE MR0103/MR0175- Confirmation of pressure tests per API 598 5)

    ■ 3.1 inspection certificate per EN 10204 (option)- Material certificate for all wetted parts per NACE MR0103/MR0175- Confirmation of pressure tests per API 598 5)

    5) Shell test: 15 s test duration with 1.5 times the permissible working pressureSeat test: 15 s test duration with 1.1 times the permissible working pressure