    SYSTEM FOR ENVIRONMENT QUALITY SUPERVISION ON THE

     INDUSTRIAL PATFORMS

    The system achieves technological control

    of pollution level into a zone with noxious

    generating units The system assures all local environment

    data acquisition and processing and

    transmits them, via satellite , in the

    INTERNET network 

  • 8/19/2019 .Monitorizare Imisii IPA.

    4/22

    System Features:

    Continuous acquisition of on-site analog and

    digital values

    Analog /Digital Conversion Local processing (filtering, normalization, average

    values)

    On schedule data transmitting over the geo-stationary satellite network ORBCOMM to a data

    server 

    Public access via Internet

  • 8/19/2019 .Monitorizare Imisii IPA.

    5/22

    The interests and needs of

    industrial companies

    for CO: 72 %

    f or CO2 : 55 %

    for Nox: 30% for Sox : 36 %

    for NH3 : 10 %

    for CH4

    : 10 %

    for metalic dusty : 72 %

  • 8/19/2019 .Monitorizare Imisii IPA.

    6/22

    The component parts of functional -

    model:

    Gaz analyzer INFRARED–2 for CO andCO2

    Communicator ST2500C 

    Real-time data acquisition software

    Communication and processing software

    Application server and dedicated website

  • 8/19/2019 .Monitorizare Imisii IPA.

    7/22

    ENVIRONMENT MONITORING SYSTEM

    FOR INDUSTRIAL AREAS

    MAIL SERVER for

    collected data

    INFRARED-2 -CO

    Mobile bi-directional

    Communicator

    + antenna

    INFRARED-2 -CO2

    Web Server for data

    Satellite

    ORBCOMM

    CONTROL CENTER

    INTERNET

  • 8/19/2019 .Monitorizare Imisii IPA.

    8/22

    DATA ACQUISITION

    The analyzer  INFRARED -2 measures thelevel of the noxious (in particular CO) andis provided with current output (4-20mA)

    The voltage analog input of the ST2500-C communicator measures voltage in therange 1..5 V

    The A/D Conversion resolution is 10 bits Final measured values are given in mg/m3

  • 8/19/2019 .Monitorizare Imisii IPA.

    9/22

    The level of the imission noxious

    (STAS 12574 compliant):

    Pre-alarm value for CO: 4,2 mg/m3

    Alarm value for CO : 6,0 mg/m3

  • 8/19/2019 .Monitorizare Imisii IPA.

    10/22

    TESTING THE FUNCTIONAL

    MODEL

    In the time period 19.08.2002 – 10. 12. 2002 the

     Environment monitoring system for industrial areas was

    installed in a five floor administrative building at METAV SA,

    in Bucharest. The collected environmental data was published on METAV SA website. Generally, the pre-alarm

    value wasn’t exceeded (see fig. 2 and fig. 3). Only in the

     period 4-6.08.2002 the pre-alarm value was exceeded with

    the medium value : 0,3mg/m3. Then the medium temperature

    was high (about 40oC - 42o C). Also in 13.08.2002 (medium

    temperature 34oC) and 23.08.2002(medium temperature

    38oC ) the pre-alarm value was exceeded .

  • 8/19/2019 .Monitorizare Imisii IPA.

    11/22

    TESTING THE FUNCTIONAL

    MODEL

    In September (13.09.2001), while the system was running, we

    made measurements with an analyzer which measured the CO

    instantaneous values. The measured value was 1,25 mg/m3 in

    the interval 12.45-13.00 (Bucharest time) and 0.7mg/m3

    at13.20 (Bucharest time) . The average values published on the

    Internet in the interval 12.00-14.00 and 14.00-16.00

    (Bucharest time) was 1.45mg /m3 and respectively 1.25

    mg/m3. In November (14.11.2001) while the system was

    running we made measurements with the OLDHAM analyzer

     between 12.00-14,00 (Bucharest time) . Between the measured

    value and the average value published on the Web site was an

    error of 0.10 mg/m3 (6%) . This means that the average values

     published on the web site are real .

  • 8/19/2019 .Monitorizare Imisii IPA.

    12/22

    Fig.2 August maximum values

  • 8/19/2019 .Monitorizare Imisii IPA.

    13/22

    Fig.2 .1August maximum values

  • 8/19/2019 .Monitorizare Imisii IPA.

    14/22

    Fig.2.2 Maximum values from August 4-th 2001

  • 8/19/2019 .Monitorizare Imisii IPA.

    15/22

    Fig 2.3 Maximum values from August 4-th 2001

  • 8/19/2019 .Monitorizare Imisii IPA.

    16/22

    Fig3 September maxim values

  • 8/19/2019 .Monitorizare Imisii IPA.

    17/22

    Fig 3.1 September maxim values

  • 8/19/2019 .Monitorizare Imisii IPA.

    18/22

    Fig. 4 November maxim values

  • 8/19/2019 .Monitorizare Imisii IPA.

    19/22

    Fig. 4.1 November maxim values

  • 8/19/2019 .Monitorizare Imisii IPA.

    20/22

    Fig 4.2 The values from November 14-th 2001

  • 8/19/2019 .Monitorizare Imisii IPA.

    21/22

    Fig 4.2 The values from November 14-th 2001

  • 8/19/2019 .Monitorizare Imisii IPA.

    22/22

    CONCLUSION

    The acquired results determine us to conclude the

     Environment Monitoring System is a very important tool for 

    industrial companies. By the mean of this system theindustrial companies can perform the control of pollution

    level in their action area . Also the communication channel

    via satellite has a small cost in comparison with other  

    communication means.