SYSTEM FOR ENVIRONMENT QUALITY SUPERVISION ON THE
INDUSTRIAL PATFORMS
The system achieves technological control
of pollution level into a zone with noxious
generating units The system assures all local environment
data acquisition and processing and
transmits them, via satellite , in the
INTERNET network
-
8/19/2019 .Monitorizare Imisii IPA.
4/22
System Features:
Continuous acquisition of on-site analog and
digital values
Analog /Digital Conversion Local processing (filtering, normalization, average
values)
On schedule data transmitting over the geo-stationary satellite network ORBCOMM to a data
server
Public access via Internet
-
8/19/2019 .Monitorizare Imisii IPA.
5/22
The interests and needs of
industrial companies
for CO: 72 %
f or CO2 : 55 %
for Nox: 30% for Sox : 36 %
for NH3 : 10 %
for CH4
: 10 %
for metalic dusty : 72 %
-
8/19/2019 .Monitorizare Imisii IPA.
6/22
The component parts of functional -
model:
Gaz analyzer INFRARED–2 for CO andCO2
Communicator ST2500C
Real-time data acquisition software
Communication and processing software
Application server and dedicated website
-
8/19/2019 .Monitorizare Imisii IPA.
7/22
ENVIRONMENT MONITORING SYSTEM
FOR INDUSTRIAL AREAS
MAIL SERVER for
collected data
INFRARED-2 -CO
Mobile bi-directional
Communicator
+ antenna
INFRARED-2 -CO2
Web Server for data
Satellite
ORBCOMM
CONTROL CENTER
INTERNET
-
8/19/2019 .Monitorizare Imisii IPA.
8/22
DATA ACQUISITION
The analyzer INFRARED -2 measures thelevel of the noxious (in particular CO) andis provided with current output (4-20mA)
The voltage analog input of the ST2500-C communicator measures voltage in therange 1..5 V
The A/D Conversion resolution is 10 bits Final measured values are given in mg/m3
-
8/19/2019 .Monitorizare Imisii IPA.
9/22
The level of the imission noxious
(STAS 12574 compliant):
Pre-alarm value for CO: 4,2 mg/m3
Alarm value for CO : 6,0 mg/m3
-
8/19/2019 .Monitorizare Imisii IPA.
10/22
TESTING THE FUNCTIONAL
MODEL
In the time period 19.08.2002 – 10. 12. 2002 the
Environment monitoring system for industrial areas was
installed in a five floor administrative building at METAV SA,
in Bucharest. The collected environmental data was published on METAV SA website. Generally, the pre-alarm
value wasn’t exceeded (see fig. 2 and fig. 3). Only in the
period 4-6.08.2002 the pre-alarm value was exceeded with
the medium value : 0,3mg/m3. Then the medium temperature
was high (about 40oC - 42o C). Also in 13.08.2002 (medium
temperature 34oC) and 23.08.2002(medium temperature
38oC ) the pre-alarm value was exceeded .
-
8/19/2019 .Monitorizare Imisii IPA.
11/22
TESTING THE FUNCTIONAL
MODEL
In September (13.09.2001), while the system was running, we
made measurements with an analyzer which measured the CO
instantaneous values. The measured value was 1,25 mg/m3 in
the interval 12.45-13.00 (Bucharest time) and 0.7mg/m3
at13.20 (Bucharest time) . The average values published on the
Internet in the interval 12.00-14.00 and 14.00-16.00
(Bucharest time) was 1.45mg /m3 and respectively 1.25
mg/m3. In November (14.11.2001) while the system was
running we made measurements with the OLDHAM analyzer
between 12.00-14,00 (Bucharest time) . Between the measured
value and the average value published on the Web site was an
error of 0.10 mg/m3 (6%) . This means that the average values
published on the web site are real .
-
8/19/2019 .Monitorizare Imisii IPA.
12/22
Fig.2 August maximum values
-
8/19/2019 .Monitorizare Imisii IPA.
13/22
Fig.2 .1August maximum values
-
8/19/2019 .Monitorizare Imisii IPA.
14/22
Fig.2.2 Maximum values from August 4-th 2001
-
8/19/2019 .Monitorizare Imisii IPA.
15/22
Fig 2.3 Maximum values from August 4-th 2001
-
8/19/2019 .Monitorizare Imisii IPA.
16/22
Fig3 September maxim values
-
8/19/2019 .Monitorizare Imisii IPA.
17/22
Fig 3.1 September maxim values
-
8/19/2019 .Monitorizare Imisii IPA.
18/22
Fig. 4 November maxim values
-
8/19/2019 .Monitorizare Imisii IPA.
19/22
Fig. 4.1 November maxim values
-
8/19/2019 .Monitorizare Imisii IPA.
20/22
Fig 4.2 The values from November 14-th 2001
-
8/19/2019 .Monitorizare Imisii IPA.
21/22
Fig 4.2 The values from November 14-th 2001
-
8/19/2019 .Monitorizare Imisii IPA.
22/22
CONCLUSION
The acquired results determine us to conclude the
Environment Monitoring System is a very important tool for
industrial companies. By the mean of this system theindustrial companies can perform the control of pollution
level in their action area . Also the communication channel
via satellite has a small cost in comparison with other
communication means.