LOCATION: HYDRABAD, INDIA

CLIMATE: INLAND COMPOSITE

CONSTRUCTION AREA: 234.00 m2

BUILDING TYPE: RESIDENTIAL BUILDING

OWNED BY: RAMLALS

Page 3: Monama house
Page 4: Monama house

This house relies on energy efficient design to reduce loads and, where possible, reverts to renewable energy to meet them. The house was completed in 2001

Page 5: Monama house

A Low environmental impact:

The underlying ideology behind the building design was to generate as low an

environmental impact as possible

Construction materials: The upper floor and roof structure is made with

reinforced concrete,which has low environmental impact. Natural materials have been chosen for most internal

finishes

Page 6: Monama house

Wall orientation:

West oriented openings are associated with external conditions of high solar radiation and

ambient temperature during the summer. Thus the windows in this orientation were

minimized or replaced with other solutions. Depending on the time of the day, high or low

pressure zones form in either east or west directions. This induces air movement from

the zone of high pressure to that of low pressure. Ventilation:

The windows of the house have been 195 degrees specially oriented such that these

pressure differences, in combination with the prevailing wind direction, may be utilized for

continuous ventilation. There is also a ventilation shaft to exhaust hot air located in the central part of the house. The open plan design supports this process by eliminating any internal resistance to the full movement

of air

Page 7: Monama house

Buried pipes and evaporative cooling:

The system used is a water pond along with an air fan. The system provides cooling by consuming just the amount of electricity necessary for the operation of the fans.

Since the fans consume less energy than air conditioners this proves an energy efficient design for maintaining human

comfort. During the humid months evaporative coolers are rendered

inefficient owing to the high humidity levels. The system allows for the ponds to

be drained during these months (July through October) and window fans used to

forcefully ventilate the house

Page 8: Monama house

Renewable energy:In Hyderabad there are four hours of power cut each day. The client specifications were

to design a system that works as a photovoltaic stand alone system during

power cuts, and as a regular grid connected system when the grid is working. The

battery chosen for this design allows for four days of autonomy, making unlikely that

the client has to use the utility power to charge the battery.

Page 9: Monama house

Solar hot water collector:

The system chosen in this house was the free flow system known as a thermosiphon

system. The system has no pump or controls and is fully automatic in operation.

In the thermosiphon system the tank is positioned above the collector. As the water in the

collector is heated by the sun, it rises into the tank mounted above the collector. This

causes the cold water in the tank to flow into the collector, where it is heated. In this way,

flow is created and the tank is filled with hot water