mom 4s 190309 - acare.cz · 25030 Castel Mella (BS) Italy Sales Switzerland Invatec Innovative...
Transcript of mom 4s 190309 - acare.cz · 25030 Castel Mella (BS) Italy Sales Switzerland Invatec Innovative...
0170293-1
ISO 9001:2000 & EN ISO 13485:2003 Cer t i f ied0124
Global Sales & Marketing Offi ceInvatec Technology Center GmbHHungerbüelstrasse 128500 Frauenfeld - Switzerland
Manufacturer & Global HeadquartersInvatec S.p.A. - Via Martiri della Libertà, 725030 Roncadelle (BS) - Italywww.invatec.com - [email protected]
Sales ItalyInvatec Italia s.r.l.Via Oriana Fallaci 3825030 Castel Mella (BS)Italy
Sales SwitzerlandInvatec Innovative Technologies AGHungerbüelstrasse 12a8500 FrauenfeldSwitzerland
Sales USAInvatec Inc3101 Emrick Blvd, Suite #113Bethlehem, PA 18020USA“Not available for sale in the US”
Sales JapanInvatec Japan K.K.Shinjuku Island Tower 5th fl .6-5-1 Nishi-shinjukuShinjuku-ku Tokyo 163-1305Japan
Sales ChinaInvatec Beijing RepresentativeOffi ce Room 1901, Tower A, Beijing Global Trade CenterNo. 36 East Road, BeisanhuanDongcheng District, BeijingChina
Sales TaiwanInvatec Taiwan No. 141 6F-4 Sec. 1 Kee Lung Road R.O.C.,TaipeiTaiwan
DistributorManufacturer
Ultra safe and effi cientin cerebral embolic protection
Under continuous product development program, Invatec reserves the right to modify specifi cations without prior notice.
Balloon material Compliant elastomeric rubber
Balloon marker distance 6 cm
Usable shaft length 95 cm
Length of the working channel 104.5 cm
Distal shaft profi le 5 F
Recommended guidewire 0.035” (0.89 mm)
Balloon occlusion range Up to 13 mm (CCA prox. balloon) Up to 6 mm (ECA dist. balloon)
1 French (F) = 0.333 mm – 1 inch (“) = 25.4 mm = 2.54 cm – 1 cm = 10 mm
Proximal Cerebral Protection Device
Ref. N° Minimum Inner diameter sheath size of the working channel
MOM0130068X5 8F 0.069“/ 1.76 mm
MOM0130069X6 9F 0.083“ / 2.12 mm
1045 mm
950 mm
60 mm
Technical specifi cations
Proximal Cerebral Protection Device
Mo.Ma Ultra protects the brain from
embolization, blocking antegrade blood fl ow
from the Common Carotid Artery (CCA) and
retrograde blood fl ow from the External Carotid
Artery (ECA): protection is established even
before the lesion is crossed.
Ultra safe Ultra easy Ultra fast Mo.Ma Ultra
Protect & C
ontrolTreat
The easiest way to achieve full time protection and controlBefore the stent crosses the lesion, the patient is fully protected.
Stagnation of the injected contrast medium at the carotid bifurcation, confi rms the proper Flow Blockage.
Effi cient and secure treatmentThe double occlusion-balloon is like a “builtin” guiding catheter, providing back-up support for successful lesion crossing and accurate stent deployment.
Blood will then be aspirated through the Mo.Ma™ Ultra working channel, until the last syringe is clear of debris.
Two in One: Ultra stable guiding catheter combined with proximal cerebral protection system
All types and sizes of debris will be captured
Capture