Modular contactors for installation into distribution boards · Modular contactors for installation...

7
176 Modular contactors for installation into distribution boards Modular contactor for installation into distribution board Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shop- ping centres, sport centers, production halls, warehouses etc. They are used for remote switching and automatic control of electric devices and equipment, such as: n lightning n all types of pumps n air-conditioning n electric heating n single-phase and three-phase motors They excel in silent operation, long mechanical life time and high quality. The contactors are designed for mounting on 35 mm mounting rail in accordance with the EN 60715 standard and they can be leaded by means of lead covers. The auxiliary contact block is available for signalization and ventilation module is available for preventing exceeded heating when contactors are used side-by-side. All contactors have degree of protection IP20. Besides the basic AC controlled types R20, R25, R40 and R63, types with increased silent operation RD20, RD25, RD40 and RD63 are available. Due to DC magnet and rectifier enable DC and AC voltage control. Surge arrestor is built in for over voltage protection. Types R20-R, RD20-R, R25-R and RD25-R are upgraded versions of basic types of modular contactors. Besides basic functions they enable manual control with a handle. Description of the handle positions: n A: the contactor functions as an installation contactor without manual control n O: permanently OFF n I: manual shifting the handle from position A to I causes the contactor to close; when control voltage is applied, the handle is automatically set to position A. Types RD20-R and RD25-R are provided with a varistor for over voltage protection and a rectifier, which enables con- trol with AC and DC voltage. Contactors with manual control enable: n switching depending on tariff (selection of the most convenient tariff) n switching when control voltage is not applied Technical specifications according to: EN60947-4-1; EN60947-5-1; VDE 0660, IEC 947-4-1; IEC 947-5-1 Modular contactors for installation into distribution boards ETICON

Transcript of Modular contactors for installation into distribution boards · Modular contactors for installation...

Page 1: Modular contactors for installation into distribution boards · Modular contactors for installation into distribution boards - type R Contactors RD series are universal power supply

176

Modular contactors for installation into distribution boards

Modular contactor for installation into distribution board

DescriptionModular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shop-ping centres, sport centers, production halls, warehouses etc.

They are used for remote switching and automatic control of electric devices and equipment, such as:n lightningn all types of pumps n air-conditioning n electric heatingn single-phase and three-phase motors

They excel in silent operation, long mechanical life time and high quality.

The contactors are designed for mounting on 35 mm mounting rail in accordance with the EN 60715 standard and they can be leaded by means of lead covers. The auxiliary contact block is available for signalization and ventilation module is available for preventing exceeded heating when contactors are used side-by-side.

All contactors have degree of protection IP20.

Besides the basic AC controlled types R20, R25, R40 and R63, types with increased silent operation RD20, RD25, RD40 and RD63 are available. Due to DC magnet and rectifier enable DC and AC voltage control. Surge arrestor is built in for over voltage protection.

Types R20-R, RD20-R, R25-R and RD25-R are upgraded versions of basic types of modular contactors. Besides basic functions they enable manual control with a handle. Description of the handle positions: n A: the contactor functions as an installation contactor without manual control n O: permanently OFF n I: manual shifting the handle from position A to I causes the contactor to close; when control voltage is applied, the handle is automatically set to position A.

Types RD20-R and RD25-R are provided with a varistor for over voltage protection and a rectifier, which enables con-trol with AC and DC voltage.

Contactors with manual control enable: n switching depending on tariff (selection of the most convenient tariff) n switching when control voltage is not applied

Technical specifications according to:EN60947-4-1; EN60947-5-1; VDE 0660, IEC 947-4-1; IEC 947-5-1

Modular contactors for installation into distribution boards

ETIC

ON

Page 2: Modular contactors for installation into distribution boards · Modular contactors for installation into distribution boards - type R Contactors RD series are universal power supply

177

Modular contactors for installation into distribution boards - type R

Contactors RD series are universal power supply AC/DC with built-in var-

istor surge protection. RD contactors produce less noise (DC coil inside)

Spring-loaded latch ensures reli-able mounting on DIN rail TH 35

Spring loaded contacts to reduce bouncing effect and prolong contact life time

Silver contacts provide the best conductivity and lowest contact

resistance

Contact status can be monitored visually or remote

by auxiliary contacts

Special terminals provide reliable connection with cables.

Specially designed mechanism consisting of two movable cores

significantly reduces the noise level at switching

Contactors series R-R have operating mode switch:

- Automatic mode (normal operation with control circuit-coil)

- Manual mode (0 - permanently open, I - constantly closed).

In manual mode constantly close operation I presence of voltage on

control circuit-coil returns contactor in automatic mode operation.

Advantages

ETIC

ON

Page 3: Modular contactors for installation into distribution boards · Modular contactors for installation into distribution boards - type R Contactors RD series are universal power supply

178

R 20-20 230V 002461210 130 12R 20-20 24 V 002461211 130 12R 20-11 230 V 002461220 130 12R 20-11 24 V 002461221 130 12R 20-02 230 V 002461230 130 12R 20-02 24 V 002461231 130 12

R 25-40 230 V 002462310 220 6R 25-40 24 V 002462311 220 6R 25-31 230 V 002462320 220 6R 25-31 24 V 002462321 220 6R 25-13 230 V 002462330 220 6R 25-13 24 V 002462331 220 6R 25-22 230 V 002462340 220 6R 25-22 24 V 002462341 220 6R 25-04 230 V 002462350 220 6R 25-04 24 V 002462351 220 6

R 25-10-24V 002463507 130 12R 25-10-230V 002463500 130 12

R 25-20-24V 002463501 130 12R 25-20 230V 002463502 130 12R 25-11 24V 002463503 130 12R 25-11 230V 002463504 130 12R 25-02 24V 002463505 130 12R 25-02 230V 002463506 130 12

1

2

A1

A2

1

2

A1

A2

3

4

1

2

A1

A2

R3

R4

R1

R2

A1

A2

R3

R4

227

R 40-40 230 V 002463410 360 4R 40-40 24 V 002463411 360 4R 40-31 230 V 002463420 360 4R 40-31 24 V 002463421 360 4R 40-22 230 V 002463430 360 4R 40-22 24 V 002463431 360 4R 40-04 230 V 002463440 360 4R 40-04 24 V 002463441 360 4

2-pole, 1 module (17,5 mm), 20 A (AC1, 400 V)Type Code No. Wiring diagram Weight Packaging

[g] [pcs]

4-pole, 2 modules (35 mm), 25 A (AC1, 400 V)Type Code No. Wiring diagram Weight Packaging

[g] [pcs]

1-pole, 1 module (17,5 mm), 25 A (AC1, 400 V)Type Code No. Wiring diagram Weight Packaging

[g] [pcs]

2-pole, 1 module (17,5 mm), 25 A (AC1, 400 V)

Technical data on page

Modular contactors for installation into distribution boards - type R

4-pole, 3 modules (52,5 mm), 40 A (AC1, 400 V) Type Code No. Wiring diagram Weight Packaging

[g] [pcs]

ETIC

ON

Page 4: Modular contactors for installation into distribution boards · Modular contactors for installation into distribution boards - type R Contactors RD series are universal power supply

179

RH 11 002461101 26 3

P721 002461110 R 25 2 10P690 002461120 R 40…, R 63… 3 10

P730 002461130 R20-R63 12 10

R 63-40 230 V 002463450 360 4 R 63-40 24 V 002463451 360 4R 63-31 230 V 002463460 360 4R 63-31 24 V 002463461 360 4R 63-22 230 V 002463470 360 4R 63-22 24 V 002463471 360 4R 63-04 230 V 002463480 360 4R 63-04 24 V 002463481 360 4

227

R 63-20 230V  002463482 1

2

A1

A2

3

4

240 6/60R 63-20 24V 002463483 240 6/60R 63-11 230V 002463484 1

2

A1

A2

3

4

240 6/60R 63-11 24V 002463485 240 6/60

Modular contactors for installation into distribution boards - type R

Auxiliary contactor block for contactors R25, R40, R63 (max. 1 piece)Type Code No. Wiring diagram Weight Packaging

[g] [pcs]

Sealing coverType Code No. For use with Weight Packaging

[g] [pcs]

Distance pieceType Code No. For use with Weight Packaging

[g] [pcs]

4 pole, 3 modules (52,5mm), 63 A(AC1, 400 V)Type Code No. Wiring diagram Weight Packaging

[g] [pcs]

Technical data on page

Distance piece

Distance piece is used where ambient temperature is higher than 40°C. Piece width is 1/2 module (8,8 mm)

Max 3 contactors can be side by side - use of distance piece is highly recommended.

2 pole, 2 modules (35 mm), 63 A(AC1, 400 V)Type Code No. Wiring diagram Weight Packaging

[g] [pcs]

New!

ETIC

ON

Page 5: Modular contactors for installation into distribution boards · Modular contactors for installation into distribution boards - type R Contactors RD series are universal power supply

180 230

RD 20-10-230V AC/DC 002464000

130 10RD 20-10-24V AC/DC 002464001

RD 20-01-230V AC/DC 002464002

RD 20-01-24V AC/DC 002464003

RD 20-20-230V AC/DC 002464004

130 10

RD 20-20-24V AC/DC 002464005

RD 20-11-230V AC/DC 002464006

RD 20-11-24V AC/DC 002464007

RD 20-02-230V AC/DC 002464008

RD 20-02-24V AC/DC 002464009

1

2

A1(+)

A2(-)

R1

R2

A1(+)

A2(-)

1

2

A1(+)

A2(-)

3

4

1

2

A1

A2

R3

R4

R1

R2

A1(+)

A2(-)

R3

R4

RD 25-40-230V AC/DC 002464010

240 5

RD 25-40-24V AC/DC 002464011

RD 25-31-230V AC/DC 002464012

RD 25-31-24V AC/DC 002464013

RD 25-22-230V AC/DC 002464014

RD 25-22-24V AC/DC 002464015

RD 25-04-230V AC/DC 002464016

RD 25-04-24V AC/DC 002464017

1

2

A1(+)

A2(-)

3

4

5

6

7

8

1

2

A1(+)

A2(-)

3

4

5

6

R7

R8

1

2

A1(+)

A2(-)

R3

R4

R5

R6

7

8

R1

R2

A1(+)

A2(-)

R3

R4

R5

R6

R7

R8

RD 40-40-230V AC/DC 002464018

420 5

RD 40-40-24V AC/DC 002464019

RD 40-31-230V AC/DC 002464020

RD 40-31-24V AC/DC 002464021

RD 40-22-230V AC/DC 002464022

RD 40-22-24V AC/DC 002464023

RD 40-04-230V AC/DC 002464024

RD 40-04-24V AC/DC 002464025

1

2

A1(+)

A2(-)

3

4

5

6

7

8

1

2

A1(+)

A2(-)

3

4

5

6

R7

R8

1

2

A1(+)

A2(-)

R3

R4

R5

R6

7

8

R1

R2

A1(+)

A2(-)

R3

R4

R5

R6

R7

R8

RD 63-40-230V AC/DC 002464026

420 5

RD 63-40-24V AC/DC 002464027

RD 63-31-230V AC/DC 002464028

RD 63-31-24V AC/DC 002464029

RD 63-22-230V AC/DC 002464030

RD 63-22-24V AC/DC 002464031

1

2

A1(+)

A2(-)

3

4

5

6

7

8

1

2

A1(+)

A2(-)

3

4

5

6

R7

R8

1

2

A1(+)

A2(-)

R3

R4

R5

R6

7

8

Modular contactors for installation into distribution boards - type RD, R...R, RD...R

Technical data on page

1-pole, 1 module (17,5 mm), 20 A (AC1, 230 V)

Type Code No. Wiring diagramWeight

[g]Packaging

[pcs]

2-pole, 1 module (17,5 mm), 20 A (AC1, 230 V)

4-pole, 2 modules (35 mm), 25 A (AC1, 400 V)

Type Code No. Wiring diagramWeight

[g]Packaging

[pcs]

4-pole, 3 modules (52,5 mm), 40 A (AC1, 400 V)

Type Code No. Wiring diagramWeight

[g]Packaging

[pcs]

4 pole, 3 modules (52,5mm), 63 A(AC1, 400 V)

Type Code No. Wiring diagramWeight

[g]Packaging

[pcs]

Take care of dissipated heat by: ≤ 40 °C max. 3 modules side by side 40 - 55 °C max. 2 modules side by side.For more contactors together, use distance piece IKV

Take care of dissipated heat by: ≤ 40 °C max. 3 modules side by side 40 - 55 °C max. 2 modules side by side.For more contactors together, use distance piece IKV

Take care of dissipated heat by: ≤ 40 °C max. 3 modules side by side 40 - 55 °C max. 2 modules side by side.For more contactors together, use distance piece IKV

Take care of dissipated heat by: ≤ 40 °C max. 3 modules side by side 40 - 55 °C max. 2 modules side by side.For more contactors together, use distance piece IKV

ETIC

ON

Page 6: Modular contactors for installation into distribution boards · Modular contactors for installation into distribution boards - type R Contactors RD series are universal power supply

181 232

R 25-40-R-230V AC 002464052

240 5

R 25-40-R-24V AC 002464053

RD 25-40-R-230V AC/DC 002464054

RD 25-40-R-24V AC/DC 002464055

R 25-31-R-230V AC 002464056

R 25-31-R-24V AC 002464057

RD 25-31-R-230V AC/DC 002464058

RD 25-31-R-24V AC/DC 002464059

R 25-22-R-230V AC 002464060

R 25-22-R-24V AC 002464061

RD 25-22-R-230V AC/DC 002464062

RD 25-22-R-24V AC/DC 002464063

R 25-04-R-230V AC 002464064

R 25-04-R-24V AC 002464065

RD 25-04-R-230V AC/DC 002464066

RD 25-04-R-24V AC/DC 002464067

R 20-10-R-230V AC 002464032

130 10

R 20-10-R-24V AC 002464033

RD 20-10-R-230V AC/DC 002464034

RD 20-10-R-24V AC/DC 002464035

R 20-01-R-230V AC 002464036

R 20-01-R-24V AC 002464037

RD 20-01-R-230V AC/DC 002464038

RD 20-01-R-24V AC/DC 002464039

R 20-20-R-230V AC 002464040

130 10

R 20-20-R-24V AC 002464041

RD 20-20-R-230V AC/DC 002464042

RD 20-20-R-24V AC/DC 002464043

R 20-11-R-230V AC 002464044

R 20-11-R-24V AC 002464045

RD 20-11-R-230V AC/DC 002464046

RD 20-11-R-24V AC/DC 002464047

R 20-02-R-230V AC 002464048

R 20-02-R-24V AC 002464049

RD 20-02-R-230V AC/DC 002464050

RD 20-02-R-24V AC/DC 002464051

1

2

A1(+)

A2(-)

3

4

R1

R2

A1(+)

A2(-)

R1

R2

A1(+)

A2(-)

R3

R4

1

2

A1(+)

A2(-)

1

2

A1(+)

A2(-)

R3

R4

1

2

A1(+)

A2(-)

3

4

5

6

7

8

1

2

A1(+)

A2(-)

3

4

5

6

R7

R8

1

2

A1(+)

A2(-)

R3

R4

R5

R6

7

8

R1

R2

A1(+)

A2(-)

R3

R4

R5

R6

R7

R8

Modular contactors for installation into distribution boards - type RD, R...R, RD...R

Technical data on page

4-pole, ON - OFF - AUTO, 2 modules (35 mm), 25 A (AC1, 400 V)

Type Code No. Wiring diagramWeight

[g]Packaging

[pcs]

1-pole, ON - OFF - AUTO, 1 module (17,5 mm), 20 A (AC1, 400 V)

Type Code No. Wiring diagramWeight

[g]Packaging

[pcs]

2-pole, ON - OFF - AUTO, 1 module (17,5 mm), 20 A (AC1, 400 V)

Take care of dissipated heat by: ≤ 40 °C max. 3 modules side by side 40 - 55 °C max. 2 modules side by side.For more contactors together, use distance piece IKV

Take care of dissipated heat by: ≤ 40 °C max. 3 modules side by side 40 - 55 °C max. 2 modules side by side.For more contactors together, use distance piece IKV

ETIC

ON

Page 7: Modular contactors for installation into distribution boards · Modular contactors for installation into distribution boards - type R Contactors RD series are universal power supply

182 234

SC20 002464071 RD 20, R20...R 3 2

SC25 002464072 RD 25, R25...R 4 2

SC40/63 002464073 RD 40, RD 60 5 2

RN-20 00246406813

14

23

2430 1

RN-02 00246406911

12

21

2230 1

RN-11 00246407013

14

21

2230 1

IKV 002464074 RD, R...R 6 1

Modular contactors for installation into distribution boards - type RD, R...R, RD...R

Technical data on page

Sealing cover

Type Code No. For use withWeight

[g]Packaging

[pcs]

Auxiliary contactor block for contactors RD, R…R, RD…R

Type Code No. Wiring diagramWeight

[g]Packaging

[pcs]

Distance piece

Type Code No. For use withWeight

[g]Packaging

[pcs]

* The auxiliary switch should not be applied in combination with RD20 and RD20-R.