MODEL# RRS - 16C · RRS - 16C - MVS RRS - 16C - VSC RRS - 16C - VEO EMAIL [email protected]...

4
REFRIGERANT RESPONSE SYSTEM NETWORK CONTROLLED SYSTEMS 3532 KATEL LA AVE. SUITE 203 LOS ALAMITOS, CA 90720 CONTACT: (714) 625-8352 WWW.NC2SYSTEMS.COM MODEL# RRS - 16C

Transcript of MODEL# RRS - 16C · RRS - 16C - MVS RRS - 16C - VSC RRS - 16C - VEO EMAIL [email protected]...

Page 1: MODEL# RRS - 16C · RRS - 16C - MVS RRS - 16C - VSC RRS - 16C - VEO EMAIL info@nc2systems.com LOCATION 3532 Katella Ave, St#203 Los Alamitos, CA 90720 Tel : (714) 625-8352 Fax: (714)

REFRIGERANT RESPONSE SYSTEM

NETWORK CONTROLLED SYSTEMS3532 KATELLA AVE. SUITE 203

LOS ALAMITOS, CA 90720CONTACT:

(714) 625-8352WWW.NC2SYSTEMS.COM

MODEL# RRS - 16C

Page 2: MODEL# RRS - 16C · RRS - 16C - MVS RRS - 16C - VSC RRS - 16C - VEO EMAIL info@nc2systems.com LOCATION 3532 Katella Ave, St#203 Los Alamitos, CA 90720 Tel : (714) 625-8352 Fax: (714)

SPECIFICATIONSComponents: RRS-16C-XXX (VSC, MVS, VEO)

Override Control Allows the operator to override the system

Configurable for Latest Standards

ANSI/ASHRAE 15, CBC, CFC & CMC

System Input and Outputs Ventilation System, Fire Alarm Panel, Mechanical Equipment Shutdown Interface

Indication Lights Provides status of alarm conditions and fan operations

Horn and Strobe Integrated Audio & Visual Alert Notifications

Thermostat Integration Works with thermostat to control exhaust fan based on space temperature (Overrides in Purge Mode)

The refrigerant response system automatically

responds to unsafe conditions while giving operators clear system

status information and direct control of relevant equipment.

WWW.NC2SYSTEMS.COM

NETWORK CONTROLLED SYSTEMS

REFRIGERANT RESPONSE SYSTEM

MODEL# RRS - 16C

Page 3: MODEL# RRS - 16C · RRS - 16C - MVS RRS - 16C - VSC RRS - 16C - VEO EMAIL info@nc2systems.com LOCATION 3532 Katella Ave, St#203 Los Alamitos, CA 90720 Tel : (714) 625-8352 Fax: (714)

MASTER VENTILATION SYSTEM EMERGENCY CONTROL PANEL (RRS-16C-MVS): Presents operators with simple system status indications and control of critical equipment.

ASHRAE Standard 15-2016, Sec 8.11.2.1 “Each machinery room shall contain a detector, located in an area where refrigerant from a leak will concentrate, that actuates an alarm and mechanical ventilation. . . at a value not greater than the corresponding TLV-TWA (or toxicity measure consistent therewith).”

FUSE In the event of a power surge, the fuse protects your investment.

LEVEL 2 ALARMUnsafe conditions. In addition to the Level 1 response, enables audio & visual alert notifications, equipment shutdown and an alert to the fire alarm system.

VENTILATION SYSTEM EMERGENCY OVERRIDE PANEL (RRS-16C-VEO - optional): An emergency override to allow operators to shutdown mechanical equipment and override the exhaust fan.

ASHRAE Standard 15-2016, Sec 8.12.h“Remote control of the mechanical equipment in the refrigerating machinery room shall be provided immediately outside the machinery room door solely for the purpose of shutting down the equipment in an emergency. Ventilation fans shall be on a separate electrical circuit and have a control switch located immediately outside the machinery room door.”

PROGRAMMABLE LOGIC CONTROLLER (Inside the RRS-16C-VSC Panel) This industrial controller is customized for your particular refrigerant detection response system.

LEVEL 1 ALARM Approaching unsafe conditions. Activates the exhaust fan and purges the system.

WWW.NC2SYSTEMS.COM

NETWORK CONTROLLED SYSTEMS

Page 4: MODEL# RRS - 16C · RRS - 16C - MVS RRS - 16C - VSC RRS - 16C - VEO EMAIL info@nc2systems.com LOCATION 3532 Katella Ave, St#203 Los Alamitos, CA 90720 Tel : (714) 625-8352 Fax: (714)

RRS - 16C - MVS RRS - 16C - VSC RRS - 16C - VEO

[email protected]

LOCATION3532 Katella Ave, St#203Los Alamitos, CA 90720

Tel : (714) 625-8352Fax: (714) 625-8144

WEBSITEwww.nc2systems.com

NETWORK CONTROLLED SYSTEMS

REFRIGERANT RESPONSE SYSTEMCRITICAL RESPONSE FOR REFRIGERATION MACHINERY ROOMS

MODEL # RRS - 16C

(optional)