Model EX640B71 Industrial vibration sensor, 4 to 20 mA output, 0 to 1 in/sec peak, 3 to 1k Hz, Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823 E-mail: [email protected] Web: www.imi-sensors.com

Transcript of Model EX640B71 Industrial vibration sensor, 4 to 20 mA .../media/resources/imi sensors/im/68... ·...

Model EX640B71

Industrial vibration sensor, 4 to 20 mA output, 0 to 1 in/sec peak, 3 to 1k Hz,

Installation and Operating Manual

For assistance with the operation of this product,contact PCB Piezotronics, Inc.

Toll-free: 800-959-446424-hour SensorLine: 716-684-0001

Fax: 716-684-3823E-mail: [email protected]

Web: www.imi-sensors.com

The information contained in this document supersedes all similar information that

may be found elsewhere in this manual.

Total Customer Satisfaction – PCB

Piezotronics guarantees Total Customer

Satisfaction. If, at any time, for any

reason, you are not completely satisfied

with any PCB product, PCB will repair,

replace, or exchange it at no charge. You

may also choose to have your purchase

price refunded in lieu of the repair,

replacement, or exchange of the product.

Service – Due to the sophisticated nature

of the sensors and associated

instrumentation provided by PCB

Piezotronics, user servicing or repair is

not recommended and, if attempted, may

void the factory warranty. Routine

maintenance, such as the cleaning of

electrical connectors, housings, and

mounting surfaces with solutions and

techniques that will not harm the

physical material of construction, is

acceptable. Caution should be observed

to insure that liquids are not permitted to

migrate into devices that are not

hermetically sealed. Such devices should

only be wiped with a dampened cloth

and never submerged or have liquids

poured upon them.

Repair – In the event that equipment

becomes damaged or ceases to operate,

arrangements should be made to return

the equipment to PCB Piezotronics for

repair. User servicing or repair is not

recommended and, if attempted, may

void the factory warranty.

Calibration – Routine calibration of

sensors and associated instrumentation is

recommended as this helps build

confidence in measurement accuracy and

acquired data. Equipment calibration

cycles are typically established by the

users own quality regimen. When in

doubt about a calibration cycle, a good

“rule of thumb” is to recalibrate on an

annual basis. It is also good practice to

recalibrate after exposure to any severe

temperature extreme, shock, load, or

other environmental influence, or prior

to any critical test.

PCB Piezotronics maintains an ISO-

9001 certified metrology laboratory and

offers calibration services, which are

accredited by A2LA to ISO/IEC 17025,

with full traceablility to N.I.S.T. In

addition to the normally supplied

calibration, special testing is also

available, such as: sensitivity at elevated

or cryogenic temperatures, phase

response, extended high or low

frequency response, extended range, leak

testing, hydrostatic pressure testing, and

others. For information on standard

recalibration services or special testing,

contact your local PCB Piezotronics

distributor, sales representative, or

factory customer service representative.

Returning Equipment – Following

these procedures will insure that your

returned materials are handled in the

most expedient manner. Before returning

any equipment to PCB Piezotronics,

contact your local distributor, sales

representative, or factory customer

service representative to obtain a Return

Warranty, Service, Repair, and

Return Policies and Instructions

Materials Authorization (RMA)

Number. This RMA number should be

clearly marked on the outside of all

package(s) and on the packing list(s)

accompanying the shipment. A detailed

account of the nature of the problem(s)

being experienced with the equipment

should also be included inside the

package(s) containing any returned

materials.

A Purchase Order, included with the

returned materials, will expedite the

turn-around of serviced equipment. It is

recommended to include authorization

on the Purchase Order for PCB to

proceed with any repairs, as long as they

do not exceed 50% of the replacement

cost of the returned item(s). PCB will

provide a price quotation or replacement

recommendation for any item whose

repair costs would exceed 50% of

replacement cost, or any item that is not

economically feasible to repair. For

routine calibration services, the Purchase

Order should include authorization to

proceed and return at current pricing,

which can be obtained from a factory

customer service representative.

Warranty – All equipment and repair

services provided by PCB Piezotronics,

Inc. are covered by a limited warranty

against defective material and

workmanship for a period of one year

from date of original purchase. Contact

PCB for a complete statement of our

warranty. Expendable items, such as

batteries and mounting hardware, are not

covered by warranty. Mechanical

damage to equipment due to improper

use is not covered by warranty.

Electronic circuitry failure caused by the

introduction of unregulated or improper

excitation power or electrostatic

discharge is not covered by warranty.

Contact Information – International

customers should direct all inquiries to

their local distributor or sales office. A

complete list of distributors and offices

can be found at www.pcb.com.

Customers within the United States may

contact their local sales representative or

a factory customer service

representative. A complete list of sales

representatives can be found at

www.pcb.com. Toll-free telephone

numbers for a factory customer service

representative, in the division

responsible for this product, can be

found on the title page at the front of this

manual. Our ship to address and general

contact numbers are:

PCB Piezotronics, Inc.

3425 Walden Ave.

Depew, NY 14043 USA

Toll-free: (800) 828-8840

24-hour SensorLineSM: (716) 684-0001

Website: www.pcb.com

E-mail: [email protected]

DOCUMENT NUMBER: 21354

DOCUMENT REVISION: B

ECN: 17900

Model Number 640B71 4-20 MA OUTPUT VELOCITY SENSOR Revision C

ECN #: 27692 Performance ENGLISH SI

Measurement Range 0.0 to 1 in/sec pk 0.0 to 25.4 mm/s pk [1] Output 4-20 mA 4-20 mA Frequency Range (±3 dB) 180 to 60000 cpm 3 to 1000 Hz [2][3] Broadband Resolution 0.005 in/sec pk 0.13 mm/s pk [4] Non-Linearity ±1 % ±1 %

Environmental Temperature Range -40 to 185 °F -40 to 85 °C

Electrical Excitation Voltage 12 to 30 VDC 12 to 30 VDC Settling Time (within 2% of value) <15 sec <15 sec Electrical Isolation (Case) >108 Ohm >108 Ohm

Physical Size (Hex x Height) 1.5 in x 3.7 in 38.1 mm x 94 mm Weight 19.5 oz 553 gm Mounting Thread 1/4 NPT No Metric Equivalent Sensing Element Ceramic Ceramic Sensing Geometry Shear Shear Housing Material Stainless Steel Stainless Steel Electrical Connector Removable Screw

Terminals Removable Screw

Terminals

Electrical Connection Position Top Top Electrical Connections (Tab 1) 4-20 mA Pos (+) 4-20 mA Pos (+) Electrical Connections (Tab 2) 4-20 mA Neg (-) 4-20 mA Neg (-) Screw Terminal Wire Size 12-24 AWG 3.0 - .2mm2

[5]

All specifications are at room temperature unless otherwise specified. In the interest of constant product improvement, we reserve the right to change specifications without notice. ICP® is a registered trademark of PCB group, Inc.

Optional Versions (Optional versions have identical specifications and accessories as listed for standard model except where noted below. More than one option maybe used.)

EP - Explosion-proof certified conduit housing with 1" pipe thread RV - Buffered Analog Signal Output - 100 mV/g (±20%)

Electrical Connector Removable Screw Terminals

Removable Screw Terminals

Electrical Connections (Tab 1) 4-20 mA Pos (+) 4-20 mA Pos (+) Electrical Connections (Tab 2) 4-20 mA Neg (-) 4-20 mA Neg (-) Electrical Connections (Tab 3) Signal Output Pos Signal Output Pos Electrical Connections (Tab 4) Signal Output Neg Signal Output Neg

Notes

[1] Conversion Factor 1 in/sec = 0.0254 m/sec. [2] 1Hz = 60 cpm (cycles per minute). [3] Current will fluctuate at frequencies below 5 Hz. [4] Typical. [5] See PCB Declaration of Conformance PS039 for details.

Supplied Accessories ICS-4 NIST-traceable single-axis amplitude response calibration from 0 cpm (0 Hz) to upper 10% frequency for 4 - 20 mA output vibration sensor (1) Entered: LLH Engineer:

MPN Sales: NJF Approved: LLH Spec Number:

Date: 11/15/2007

Date: 11/12/2007

Date: 11/12/2007

Date: 11/26/2007

27393

3425 Walden Avenue Depew, NY 14043 UNITED STATES Phone: 716-684-0003 Fax: 716-684-3823 E-mail: [email protected] Web site: www.imi-sensors.com

lholtz
Text Box
32675-D ECO#: 34407