MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab &...

8
FINISH FLOOR ELEV. @ 0" FINISH FLOOR ELEV. @ 0" TOP OF BEARING (MAIN) ELEV. @ 10'-0" TOP OF BEARING (MAIN) ELEV. @ 10'-0" 8" RAISED BANDING 16080 OHGD 3080 ENTRY W/ 12" SIDE LITE 2-26 SH 26 SH TILE OR SHINGLE ROOF 5 12 5 12 1'-4" 1'-4" TOP OF BEARING (ENTRY) ELEV. @ 12'-0" HEEL OF TRUSS TO MATCH TOP OF GABLE @ BEDROOM #3 HEEL OF TRUSS TO MATCH TOP OF GABLE @ BEDROOM #3 8'-0" FINISH FLOOR ELEV. @ 0" FINISH FLOOR ELEV. @ 0" TOP OF BEARING (MAIN) ELEV. @ 10'-0" TOP OF BEARING (MAIN) ELEV. @ 10'-0" 5 12 5 12 3-4080 SL. GL. DR. 2-25 SH 2-25 SH TILE OR SHINGLE ROOF 8'-0" ELECTRIC METER A/C UNIT 1'-4" 1'-4" FINISH FLOOR ELEV. @ 0" FINISH FLOOR ELEV. @ 0" TOP OF BEARING (MAIN) ELEV. @ 10'-0" TOP OF BEARING (MAIN) ELEV. @ 10'-0" 8'-0" 12 5 12 5 12 5 DECO TEXTURE FINISH OVER CONC. BLOCK TILE OR SHINGLE ROOF 25 SH 25 SH 48"X12" F.G. 48"X12" F.G. FYPON RAISED BANDING 1'-4" 8080 SL.GL.DR. 7'-0" FINISH FLOOR ELEV. @ 0" TOP OF BEARING (MAIN) ELEV. @ 10'-0" 24"X24" F.G. 24"X24" F.G. 24"X24" F.G. ELECTRIC METER (VERIFY LOCATION) 12 5 12 5 DECO TEXTURE FINISH OVER CONC. BLOCK TILE OR SHINGLE ROOF 8'-0" A/C DISCONNECT WP GFI 1'-4" 24 SH 11 1/ 2" 1'-4" DECO-FYPON #1585-1091 FLASHING AND DRIP EDGE PER NOTES IN TABLE 2 ON A-6 2X6 MIN. SUB FASCIA 1'-4" CANTILEVER 5 12 SOFFIT DETAIL SCALE: 3/4"=1'-0" SCALE: DATE: DRAWN BY: CHECKED BY: PLAN: REVISED: DESIGN IN ACCORDANCE WITH THE RESIDENTIAL FLORIDA BUILDING CODE 2017 - 6TH EDITION As indicated K:\1-MASTER 2019\2019-BUILDERS\DR HORTON 2019\MODELS\2256 E\REVIT\2256 E.rvt A - 1 ELEVATION # 2256 E MODEL 09/15/19 ADDRS: Enter address here GCD JOB # 1/4" = 1'-0" FRONT ELEVATION 1/4" = 1'-0" REAR ELEVATION 1/4" = 1'-0" LEFT SIDE ELEVATION 1/4" = 1'-0" RIGHT SIDE ELEVATION

Transcript of MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab &...

Page 1: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

8" RAISED

BANDING

16080 OHGD3080 ENTRY W/

12" SIDE LITE

2-26 SH26 SH

TILE OR SHINGLE ROOF

5

12

5

12

1'-4" 1'-4"

TOP OF BEARING (ENTRY)ELEV. @ 12'-0"

HEEL OF TRUSS TO

MATCH TOP OF GABLE

@ BEDROOM #3

HEEL OF TRUSS TO MATCH TOP

OF GABLE @ BEDROOM #3

8'-0

"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

5

12

5

12

3-4080 SL. GL. DR. 2-25 SH2-25 SH

TILE OR SHINGLE ROOF

8'-0

"

ELECTRIC

METER

A/C UNIT

1'-4"1'-4"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

8'-0

"

12

5

12

5

12

5

DECO TEXTURE FINISH

OVER CONC. BLOCK

TILE OR SHINGLE ROOF

25 SH25 SH 48"X12"

F.G.

48"X12"

F.G.

FYPON

RAISED BANDING

1'-4"

8080 SL.GL.DR.

7'-0

"

FINISH FLOORELEV. @ 0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

24"X24"

F.G.

24"X24"

F.G.

24"X24"

F.G.

ELECTRIC METER

(VERIFY LOCATION)

12

5

12

5

DECO TEXTURE FINISH

OVER CONC. BLOCK

TILE OR SHINGLE ROOF

8'-0

"

A/C DISCONNECT

WP

GFI

1'-4"

24 SH

11 1/2"

1'-4

"

DECO-FYPON

#1585-1091

FLASHING AND DRIP

EDGE PER NOTES IN

TABLE 2 ON A-6

2X6 MIN. SUB FASCIA

1'-4"

CANTILEVER

5

12

SOFFIT DETAIL SCALE: 3/4"=1'-0"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

A-1

ELEVATION

# 2

256 E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

1/4" = 1'-0"

FRONT ELEVATION

1/4" = 1'-0"

REAR ELEVATION

1/4" = 1'-0"

LEFT SIDE ELEVATION

1/4" = 1'-0"

RIGHT SIDE ELEVATION

Page 2: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

WH

49'-8"

15'-4" 1'-4" 19'-8"

49'-8"

36'-4" 13'-4"

11'-0" 12'-4" 5'-8" 2'-4" 16'-0" 2'-4"

2'-4" 4'-1"

18

'-8

"8

'-2

"6

'-4

"1

5'-3

"

36'-4" 13'-4"

2'-1" 2'-7" 4'-1" 20'-10" 12'-2" 5'-9" 2'-2"

4'-0" 37'-0 1/2" 8'-7 1/2"

PAVER BY

OTHERS

6" X 12" RECESS

STANDARD SGD RECESS 1-1/2".

IMPACT GLASS SGD RECESS 2-1/2".

SIN

K &

DIS

P

RUN CONDUIT FOR

ELECTRIC AT ISLAND RANG

E

PROVIDE 1/4" WATER

LINE @ REF. SPACE

FOR ICE MAKER

TIL

E S

HO

WER

RECES

S 3

-1/2

"

5'-0

" TUB

PAVER BY

OTHERS

ELEV. @ 0'-4"

2" SLO

PE

16080 O.H. GARAGE DOOR

WASHER

49'-8"

21

'-6

"2

2'-1

"2

1'-6

"

9'-6

"3

2'-7

"

8" 3'-0" 1'-4 1/2"

21

'-9

"5

'-0

1/2

"2

1'-7

1/2

"

20'-3" 12'-2" 3'-11"

2'-4

"8

'-0

"8

"

8"

10

'-4

"

36"X36"

CONC. PAD

ELECTRIC METER

VERIFY LOCATION

11

'-0

"4

8'-5

"1

'-8

"4

'-0

"

4'-0" 7'-5 1/2" 38'-2 1/2"

STUB OUT FOR

OPTIONAL OUTDOOR

KITCHEN & SINK

HB

HB

OPTIONAL 60" HIGH WALL W/ 8"

BOND BEAM & 1#5 ROD

3'-1

0"

REF. SPACE

4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #

10/10 W.W.M. REINFORCING OVER 6

MILL VISQUEEN BARRIER ON

MECHANICALLY COMPACTED FILL @ 95%.

THE FINISH FLOOR SLAB SHALL BE SET

ABOVE BASE FLOOD ELEVATION PER FEMA

FLOOD MAP PLUS 1'-0" FREEBOARD PER

FBCR R322.2.1. SEE SITE PLAN BY OTHERS

ELEV. @ 0'-0"

LOWEST POINT OF GARAGE SHALL BE SET ABOVE

BASE FLOOD ELEVATION PER FEMA FLOOD MAP

SET A/C PAD ABOVE

FLOOD W/ 1'-0"

FREEBOARD PER

FBCR R322.2.1

SET W/H ABOVE FLOOD W/ 1'-0"

FREEBOARD PER FBCR R322.2.1

65

'-1

"

65

'-1

"

STANDARD SGD RECESS 1-1/2".

IMPACT GLASS SGD RECESS 2-1/2".

PROVIDE TERMITE TREATMENT

WITH "BORA CARE"

DW

ELEV. @ 0'-4"

ELEV. @ 0'-0"

OR DOORS

21" MIN. TO

FIXTURES, WALLS 1'-9"

8'-0

"36" MAX.

OR DOORS

21" MIN. TO

FIXTURES, WALLS

MIN.

1'-0"

19

" M

IN.

19

" M

IN.

15" MIN.

TO FINISH

FRONT ELEVATION SIDE ELEVATION

WATER CLOSET CLEARANCE DETAIL

8'-0

"

FRONT ELEVATION SIDE ELEVATION

VANITY SINK CLEARANCE DETAIL

4"

2'-5

1/2

"

8'-0

"

VARIES

4"

2'-5

1/2

"VARIE

S

VARIES

8'-0

"

MIRROR

FAUCET

KICK PLATE

FAUCET

MIRROR

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

A-2

FOUNDATION

# 2

256

E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

1/4" = 1'-0"

SLAB & PLUMBING PLAN

Page 3: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

WH

PLAN NOTES

1) VERIFY ALL ROUGH OPENING DIMENSIONS FOR

ALL WINDOWS AND DOORS

2) PROVIDE SAFETY GLAZING WITHIN 24" FROM EXIT

PER FLORIDA BUILDING CODE R 308.4.2.

3) PROVIDE SAFETY GLAZING AT BATH/ SHOWER

PER FLORIDA BUILDING CODE R 308.4.5.

4) NON BEARING INTERIOR FRAME WALLS SHALL BE

FRAMED W/ WOOD OR METAL STUDS. SPACING SHALL

NOT EXCEED 24" O.C. (NON BEARING WALLS ONLY)

5) PROVIDE DEAD WOOD IN ATTIC FOR OVERHEAD

GARAGE DOOR HARDWARE

6) KITCHEN KNEE WALL TO BE FRAMED W/ TOP @

341/2" A.F.F.

7) INSTALL SMOOTH WALLS IN KITCHEN AND ALL

BATHROOM AREAS

8) WHERE DRYWALL CEILING IS APPLIED TO TRUSSES

@ 24" O.C. USE 5/8" DRYWALL OR 1/2" SAG

RESISTANT PER SEC. 702.3.5

9) THE GARAGE SHALL BE SEPARATED FROM THE

RESIDENCE & ATTIC BY NOT LESS THEN 1/2" GYPSUM

BOARD APPLIED TO THE GARAGE SIDE. GARAGES

BENEATH HABITABLE ROOMS SHALL BE SEPARATED

WITH NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD

OR EQUIVALENT. WHERE THE SEPARATIION IS A

FLOOR - CEILING ASSEMBLY, THE STRUCTURE

SUPPORTING THE SEPARTION SHALL ALSO BE

PROTECTED BY NOT LESS THAN 1/2" GYPSOM BOARD

OR EQUIVALENT

10) INSTALL 1 3/8" THICK SOLID WOOD DOOR BETWEEN

LIVING AND GARAGE PER FLORIDA BUILDING CODE

R302.5.1.

11) ALL WINDOWS INSTALLED 72" ABOVE GRADE MUST

COMPLY WITH R612.2 MIN 24" SILL HEIGHT OR

PROVIDED WITH AN APPROVED WINDOW FALL

PRVENTION DEVICE

12) ALL CLOSET SHELVES TO BE 12". ALL PANTRY &

LINEN TO BE (4)-16" SHELVES 18" 0.F.F. W/ 15"

INCREMENT.

13) ALL MECHANICAL AND ELECTRICAL EQUIPMENT TO BE

INSTALLED AT OR ABOVE FLOOD PLUS 1'-0" FREEBOARD.

DOOR HEADERS6'-8" BI-FOLD

6'-8" SWING

8'-0" SWING

HEADER HEIGHT 82" A.F.F.

82 1/2" A.F.F.

98 1/2" A.F.F.

HEADER HEIGHT

HEADER HEIGHT

CABINET BACKING

KITCHEN

MASTER BATH

GUEST BATH

LAUNDRY ROOM

UPPER TOP @ 84" BASE TOP @ 35"

UPPER

UPPER

UPPER TOP @ 84"

BASE TOP @ 35"

BASE TOP @ 31"

BASE

SQUARE FOOTAGE

LIVING AREA

GARAGE AREA

LANAI AREA

FRONT PORCH/ ENTRY AREA

2,214

439

400

22

TOTAL SQUARE FOOTAGE 3,075

49'-8"

15'-4" 1'-4" 19'-8" 3'-6" 9'-10"

2'-4

"8

'-0

"8

"5

'-0

"9

'-0

"5

'-8

"4

'-4

1/2

"8

'-2

1/2

"

5'-3

3/4

"7

'-1

1/4

"

15

'-8

"5

'-9

"3

'-5

"2

'-0

"6

'-4

"2

'-4

"1

2'-1

1"

7'-6" 4'-0" 4'-1" 2'-1" 4'-11" 6'-8 1/2" 20'-4 1/2"

4'-0

"7

'-4

"4

'-3

1/2

"3

'-6

1/2

"2

'-4

1/2

"1

2'-1

0 1

/2"

8'-2" 3'-4" 4'-1" 2'-1" 4'-11" 6'-8 1/2" 6'-0 1/2" 4'-5 1/2" 9'-10 1/2"

11'-0" 38'-8"

2 CAR GARAGE

ENTRY

FOYER

UTILITY

PANTRY

W.I.C

W.I.C.

KITCHEN

LIVING

DINING

MASTER SUITE

BEDROOM #2

BEDROOM #3

BATH #2

LANAI

MIN. R-13 OR

BETTER INSULATION

2'-8

"2

'-8

"2

'-8

"2

9'-0

"2

8'-1

"

36'-4" 13'-4"

8"

10

'-4

"

1'-4

"9

'-8

"1

'-6

"1

0'-3

1/2

"1

0'-5

1/2

"6

'-4

1/2

"1

9'-9

1/2

"1

'-8

"4

'-0

"

8" 3'-0" 3"

8'-0

"

15'-6 1/2" 25'-1 1/2" 9'-0"

VINYL SHELVING

D W

VINYL SHELVING

LINEN

VINYL SHELVING

VINYL SHELVING

VINYL SHELVING

VIN

YL

SHELV

ING

TILE

SHOWER

RECESS

3-1/2"

MIR

.

MIR.

5'-0

" TUB

2

2

2

5

22

4

6

2

2

6

2

2

2

2

2

5 1

E

D

CC

A

2

3

A

BB

B

RANG

E

DBL

SIN

K

DW

OVERH

EAD

CABS

NOTE: INSTALL 1-3/8" THICK

SOLID WOOD DOOR BETWEEN

LIVING AND GARAGE PER

R302.5.1

NOTE: THE GARAGE SHALL

BE SEPARATED FROM THE

RESIDENCE AND ITS ATTIC

AREA BY NOT LESS THEN 1/2"

GYPSUM BOARD APPLIED TO

THE GARAGE SIDE

22" X 54"

ATTIC ACCESS

VERIFY LOCATION WITH

SITE PLAN, A/C NOT TO

ENCROACH EASEMENT

EGRESS

COFFERED CEILING

OPTIO

NAL

VALE

T

OVERH

EAD

CABS

OVERHEAD CABS

3'-1

3/4

"COFFERED CEILING

COFFERED

CEILING

COFFERED

CEILING

VIN

YL

SH

ELV

ING

EG

RES

S

EGRESS

EGRESS

LT

KNEEWALL

MASTER BATH

6

6

LINEN

GG

F

22"X36" ATTIC

ACCESS

2

A/H

UNIT

STUB OUT FOR

OPTIONAL OUTDOOR

KITCHEN & SINK

12'-0" CEILING

E

2'-11 5/8" 8'-0 3/8" 2'-0" 5'-2" 5'-2" 5'-8" 2'-4" 16'-0" 2'-4"

49'-8"

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

11

'-0

"

ESCAPE

TOP OF

SQAURE

OPENING 6'-8"

TOP OF SQAURE

OPENING

OPT.

10'-0" FLAT CEILING10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

SEE NOTE 9

HB

HB

8'-0

"

60" HIGH WALL W/ 8" BOND

BEAM & 1#5 ROD

10'-0" FLAT CEILING

3'-1

0"

42" KNEEWALL

W/ GLASSTOP

A-3

B

A-3A

MF

REF. SPACE

4

11'-3" 9'-0" 12'-2" 3'-11"

65

'-1

"

65

'-1

"

SAFETY G

LAZED

SAFETY G

LAZED

SAFETY G

LAZED

INTERIOR DOOR SCHEDULE

MARK

1

2

3

DOOR WIDTH NOTES

P.K. = POCKET DOOR

B.F. = BI-FOLD DOOR

B.P. = BI-PASS DOOR

L.V. = LOUVERED DOOR

4

5

6

7

8

3'-0"

2'-8"

2'-6"

2'-4"

2'-0"

1'-8"

1'-6"

2'-10"

FACE OF OUTSIDE WALL TO FACE OF STUD WALL FACE OF STUD TO FACE OF STUD

1/2"

3 1/2"

1/2"

FACE OF EXTERIOR WALL

1/2"

3 1/2"

1/2"TYPICAL DIMENSION STRING

TOILET PAPER ROLL

2'-6"

1'-8"

TOWEL BAR

4'-0"

3'-2"

MIN.

4"

MIN.

4"

BATHROOM NOTES

ALL TUB DECKS @ 21" A.F.F

ALL BLOCKING TO BE PT IN SHOWERS

TOWEL BAR

TP TOILET PAPER

TB

FINISH FLOORELEV. @ 0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

3'-4

"6

'-8

"

5'-0"

FINISH FLOORELEV. @ 0"

TOP OF BEARING (MAIN)ELEV. @ 10'-0"

3'-4

"6

'-8

" 3'-0"

A-3

B

5'-3

3/4

"7

'-1

1/4

"

6'-0 1/2" 4'-5 1/2"

UTILITY

PANTRY

W.I.C

MIN. R-13 OR

BETTER INSULATION

VINYL SHELVING

D W2

2

2

2

OVERHEAD CABS

LT

10'-0" FLAT CEILING

10'-0" FLAT CEILING

TOP OF

SQAURE

OPENING 6'-8"

OPT.

10'-0" FLAT CEILING

REF. SPACE

5'-8

1/2

"6

'-1

0 1

/2"

2

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

A-3

FLOOR

# 2

256

E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

DOOR SCHEDULETYPE

MARK SIZE CODE

PRODUCT

DESCRIPTION WIDTH HEIGHT COMMENTS COUNT

1 12"X96" SIDE LITE DISTINCTION 1'-0" 8'-0" 1

2 (3)-4080 SL. GL. DR. DISTINCTION 12'-2" 8'-0" 1

3 2-4080 SL. GL. DR. DISTINCTION 8'-0" 8'-0" 1

4 16080 OHGD GARAGE DOOR 16'-0" 8'-0" 1

5 3080 ENTRY DISTINCTION 3'-0" 8'-0" 1

WINDOW SCHEDULE

MARK SIZE CODE

PRODUCT

DESCRIPTION WIDTH HEIGHT COMMENTS Count

A 2-25 SH 6'-4" 5'-3" 2

B 24"X24" FIXED GLASS 2'-0" 2'-0" 3

C 25 SH 3'-2" 5'-3" 2

D 2-26 SH 6'-4" 6'-3" 1

E 26 SH 3'-2" 6'-3" 2

F 24 SH 3'-2" 4'-3" 1

G 48"X12" FIXED GLASS 4'-0" 1'-0" 2

1/4" = 1'-0"

FLOOR PLAN3/8" = 1'-0"A-3

B FOYER/ GREAT ROOM DETAIL

3/8" = 1'-0"A-3

A FOYER/ HALLWAY DETAIL

1/4" = 1'-0"

FLOOR PLAN - OPT BATH

Page 4: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

WH

RID

GE

RID

GE

RID

GE

HIP

HIP

HIP

HIP

HIP

HIP

HIP

HIP

VAL

LEY

VAL

LEY

MASTER

SUITE

BEDROOM #2

BEDROOM #3

2 CAR GARAGE

DINING ROOM

GREAT ROOM

KITCHEN

LAUNDRY

LANAI

ENTRY

W.I.C.

BATH #2

MASTER

BATH

FOYER

PANTRY

RID

GE

COFFERED CEILING

COFFERED CEILING

10'-0" FLAT CEILING

2'-0

"

2'-0"

2'-0

"

2'-0"

2'-0

"

2'-0"

2'-0

"

2'-0"

1'-0

"

1'-0"

1'-0"

1'-0

"

1'-0"

1'-0"

1'-0

"

COFFERED

CEILING

COFFERED

CEILING

12'-0" CEILING

HIP

HIP

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

W.I.C.10'-0" FLAT CEILING

A

A-4

B

A-4

B

A-4

B

A-4

3'-1

0"

B

A

6"

6" 2'-0" 3'-4"

2'-0" 5'-0" 2'-0"

6"

2'-0"

3'-4"

A/H

A/H

AIR HANDLER DETAIL

ATTIC VENTILATIONVERIFY VENTING REQUIREMENTS

WITH ENERGY CALCULATIONS

WITHOUT OFF RIDGE VENTS WITH OFF RIDGE VENTS (O.R.V.)

ATTIC AREA

(FBC R806)

VENTILATION REQUIRED

(ATTIC AREA 1/150)

VENTILATION REQUIRED(ATTIC AREA 1/300 INSTALL PER

FBC R806.2 MINIMUM AREA REQUIREMENTS)

MARK

1

SQUARE FOOTAGE

2256 SQ. FT.

SOFFIT VENTS

20.92 SQ. FT.

MIN AIR FLOW

OF SOFFIT

6.62 %

OFF RIDGE VENTSMIN AIR FLOW

OF SOFFIT

TOTAL

VENTILATION

O.R.V. NOT USED

ATTIC VENTILATION CALCULATIONATTIC VENTILATION CALCULATION

ATTIC SQ. FT. / 150 = VENTED SQ. FT. ATTIC SQ. FT. / 300 = VENTED SQ. FT.

OFF RIDGE EXHAUST VENT SIZES

(AREA NET FREE SQUARE FEET)

6'-0" BASE

BASE

-2'-0"

25" BASE

25" BASE

18" BASE

17" BASE

1.45 SQ. FT.

FREE AREA

1 SQ. FT.

FREE AREA

.38 SQ. FT.

FREE AREA

ELEVATION @ BEARING

ELEVATION @ +24"

BEARING HEIGHT

= BEARING @ 10'-0"

= BEARING @ 12'-0"

ELEVATION @ +12"

ELEVATION @ BEARING

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

A-4

ROOF

# 2

256

E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

1/4" = 1'-0"

ROOF PLAN

3/8" = 1'-0"A-4

A COFFER DETAIL

3/8" = 1'-0"A-4

B COFFER DETAIL B

Page 5: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

WH

P

P

P

TV

TV

TV

TV

T

T

T

T

DB

A/C DISCONNECT

WP

GFI

EXH.

FAN

EXH.

FAN

WP

GFI

WP

GFI

GFI

GFI

GFI

GFI

GFI

GFIGFIGFI

GFI @

42" A.F.F.

GFI @

42" A.F.F.

UNDER

SINK

GFI

VP

VP

ELECTRIC METER200 AMP

PANEL

STUB OUT FOR

GARAGE DOOR

OPENER

SD

SCD

SD

SCDSD

GFI

GFI

GFI

GFI @

42" A.F.F.

OPTIONAL WP GFI BELOW

COUNTER TOP FOR FRIDGE

OPTIONAL WP GFI ABOVE COUNTER TOP

J

ELECTRICAL NOTES:

ALL OUTLETS IN WET AREAS AND ALL

ALL ELECTRIC, ELECTRICAL EQUIPMENT AND APPLIANCES TO BE SET AT

OR ABOVE BASE FLOOD ELEVATIONS PLUS 1'-0" FREEBOARD.

ARC-FAULT CIRCUIT-INTERRUPTERS AND TAMPER

RESISTANT RECEPTACLES SHALL BE INSTALLED

INSTALL PHONE AND T.V PER CONTRACT.

IN DWELLING UNITS PER N.E.C 210.12 AND 406.11

EXTERIOR OUTLETS TO BE GFI'S.

NOTE: NOT ALL SYMBOLS ARE USED FOR THIS

PROJECT.

SURFACE MOUNTED CEILING LIGHT

TELEVISION RECEPTION OUTLET

AC/DC SMOKE DETECTOR

TO BE INTERCONNECTED

WALL MTD. BRACKET LIGHT

DIMMER SWITCH

3 WAY SWITCH

SINGLE POLE SWITCH

TELEPHONE OUTLET

MOTION SENSOR SWITCH

A/C DISCONNECT

DUPLEX FLOOD LIGHT

TRACK MTD. LIGHTS

EXHAUST FAN

PUSH BUTTON (PB) / DOOR BELL (DB)

RECESSED LIGHT

1/2 SWITCHED DUPLEX OUTLET

DUPLEX RECEPTACLE OUTLET

4-PLEX RECEPTACLE OUTLET

220 V RECEPTACLE OUTLET

SINGLE RECEPTACLE OUTLET

DUPLEX RECEPTACLE AT ELEV. A.F.F.

ELECTRICAL PANEL

ELECTRICAL METER

120 V JUNCTION BOX

DUPLEX RECEPTACLE - ABOVE COUNTER

3

D

SD

TV

ELECTRICAL LEGEND

2' UNDER COUNTER LIGHT

4' FLUORESCENT LIGHT

INTERCOMIC

KP

KEYPAD

ANY RESIDENT HAVING A FOSSIL-BURNING

HEATER OR APPLIANCE, A FIREPLACE, OR

AN ATTACHED GARAGE SHALL HAVE AN

OPERATIONAL CARBON MONOXIDE ALARM

INSTALLED WITHIN 10 FEET OF EACH

ROOM USED FOR SLEEPING PERPOSES.

PER RULE 9B-3.04.72

SD (SMOKE DETECTOR)

SCD (CARBON MONOXIDE/ SMOKE

DETECTOR)

AFF

MS

INSTALL ALL ELECTRICAL PER NEC 2014

SCD

T

200 AMP ELECTRICAL RISER DIAGRAM

200 AMP

PANELM

(2) 4/0 AL & (1) 1/0 AL

OR CU EQUIVALENT

#6 CU MIN. TO (2) GROUND RODS,

AT LEAST 6FT APART.

POWER CO.

300 AMP ELECTRICAL RISER DIAGRAM

150 AMP

PANEL

150 AMP

PANELM

(2) 2/0 AL & (1) 1/0 AL

OR CU EQUIVALENT

#6 CU MIN. TO (2) GROUND RODS,

AT LEAST 6FT APART.

POWER CO.

ELECTRICAL PLAN 2256 "E"

200 AMP SERVICE

TAG

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

QUANTITY PRODUCT

(23)

(2)

(5)

(X)

(5)

(X)

(X)

(2)

(X)

(1)

(X)

(X)

(X)

(X)

(X)

(X)

(X)

(RECESSED CANS)

(VAPORS)

(PENDANT LIGHT

(10" MUSHROOMS)

(24" 3 LT)

(36" 4 LT)

(NOT USED)

(COACH LIGHTS)

(COACH LIGHTS)

(J BOX)

(4' FLUORESCENT)

(2' FLUORESCENT)

(5LT CHANDELIER)

(3 LT )

(PENDANT/ NOOK)

(X)

(X)

EXH.

FAN

GFIGFIGFI

GFI @

42" A.F.F.

GFI @

42" A.F.F.

GFI @

42" A.F.F.

GFI

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

A-5

ELECTRICAL

# 2

256

E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

1/4" = 1'-0"

ELECTRICAL PLAN

A

OPT.OPT. OPT.

OPT.OPT.

A

A A

A A

AA

AAA

A A

AA

A

AA

A

A

AA

A

A

OPT.

KEYLESS

22"X36"ATTIC

ACCESS

3

3

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

PRE-WIRE FOR

FAN (TYP.)

OPT. OPT.

OPT.OPT.

A

A

NOTE: VERIFY

LOCATION OF GFI

DECO BAND

H H

A/H

OPT.

OPT.

1/4" = 1'-0"

ELECTRICAL PLAN OPT POWDER BATH

Page 6: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

RESIDENTIAL SPECIFICATIONS

1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT

THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL

REPORT ALL DISCREPENCIES BETWEEN THE DRAWINGS AND EXISTING

CONDITIONS TO THE DESIGNER PRIOR TO COMMENCING WORK.

2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK

ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES,

HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO

ATTACH AND ACCOMMODATE OTHER WORK.

3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED

TO BE TYPICAL AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILAR

SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT

DETAIL IS SHOWN.

4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE

FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 2,000

PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO

THE DESIGNER PRIOR TO COMMENCING WORK.

5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUCTION WITH JOB

SPECIFICATION AND HOUSE PLANS, MECHANICAL, ELECTRICAL,

PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR

SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON

STRUCTURAL DRAWINGS.

6. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED IF APPROVED BY THE

ENGINEER IN WRITING, THE INSTALLATION OF THE FASTENERS

SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.

SIMPSON FASTENERS SPECIFIED MAY BE SUBSTITUTED WITH THE SAME QUANTITY

AND EQUIVALENT STRENGTH PRODUCT.

ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING

NAILS, SHALL BE HOT MOPED DIPPED GALVANIZED OR STAINLESS STEEL

CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES,

WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS

AND CONNECTORS AS SPECIFIED HEREIN.

7. TREATED WOOD REQUIREMENTS:-

ALL TREATED WOOD EXPOSED TO WEATHER SHALL BE PROTECTED, PRESSURE TREATED,

OR NATURALLY RESISTANT TO DECAY.

ALL WOOD TOUCHING MASONRY OR CONCRETE SHALL BE ISOLATED, OR

PRESSURE TREATED.

8. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER

THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILTY

TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF

THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE

NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE DOWNS.

9. CEILING DRYWALL INSTALLED WITHIN THE HOUSE TO TRUSSES SPACED 24" O.C.

SHALL BE 5/8" DRYWALL OR 1/2" SAG RESISTANT PER SEC. 702.3.5

10. LANAI CEILINGS & COVERED ENTRY CEILINGS

1X4 STRIPPING @ 16" O.C. FASTENED WITH 2-8d NAILS TO EACH TRUSS. 5/8"

EXTERIOR GYP. BOARD CEILING FASTENED WITH 8d NAILS OR 1-5/8" DRYWALL

SCREWS @ 6" O.C. EDGE AND FIELD.

GENERAL NOTES

1

ROOF SHEATHING

SHALL BE APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER.

INSTALL PANELS WITH LONG DIMENSION PLACED PERPENDICULAR TO TRUSSES.

A 1/8" SPACE BETWEEN ADJACENT SHEETS SHALL BE MAINTAINED . INSTALL "H"

CLIPS AT UNSUPPORTED PANEL EDGES. THE ROOF SHEATHING SHALL BE NAILED WITH

8d RING SHANK NAILS @ 6" O.C. EDGE AND 6" O.C. FIELD. ENSURE THAT ALL NAILS

PENETRATE THE TOP CHORD OF THE TRUSSES WITHOUT SPLITTING. RING SHANK NAILS

PER R803.2.3.1 - 0.113" NOMINAL SHANK DIAMETER, RING DIAMETER OF 0.012"

OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULL

ROUND HEAD, 2" NAIL LENGTH.

FLASHING

FLASHING SHALL BE ALUMINUM, ALUMINUM ZINC COATED STEEL 0.0179" THICK,

26 GAUGE AZ50 ALUM ZINC, OR GALVANIZED STEEL 0.0179" THICK, 26 GAUGE

ZINC COATED G90. FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE ZIP

SYSTEM ROOF SHEATHING MANUFACTURES PUBLISHED REQUIREMENTS. ALL

FLASHING AND INSTALLATION SHALL CONFORM TO SECTION R905.2.8 (1 TO 5).

DRIP EDGE

DRIP EDGE SHALL BE PROVIDED AT ALL EAVES AND GABLES OF SHINGLES ROOFS,

LAPPED A MINIMUM OF 3" @ JOINTS. THE OUTSIDE EDGE SHALL EXTEND A MINIMUM

OF 1/2" BELOW SHEATHING AND THE INSIDE EDGE SHALL EXTEND BACK A MINMUM

OF 2". DRIP EDGE SHALL BE FASTENED AT NO MORE THAN 4" CENTERS. THERE SHALL

BE A MINIMUM OF 4" WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE.

GENERAL ROOF ASSEMBLY

2

INSTALL PEEL AND STICK UNDERLAYMENT APPROVED FOR SINGLE

LAYER APPLICATION UNDER TILE ROOF.

THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL COMPLY

WITH THE PROVISIONS OF R905.3 F.B.C.

MARKING: EACH ROOF TILE SHALL HAVE A PERMANENT

MANUFACTURER'S IDENTIFICATION MARK.

APPLICATION SPECIFICATIONS: THE TILE MANUFACTURER'S WRITTEN

APPLICATION SPECIFICATIONS SHALL BE AVAILABLE AND SHALL

INCLUDED BUT NOT BE LIMITED TO THE FOLLLOWING:

1. TILE PLACEMENT AND SPACING,

2. ATTACHMENT SYSTEM NECESSARY TO COMPLY

WITH CURRENT WIND CODE,

A. AMOUNT AND PLACEMENT OF MORTART

B. AMOUNT AND PLACEMENT OF ADHESIVE

C. TYPE, NUMBER, SIZE AND LENGTH OF FASTENERS AND CLIPS.

3. UNDERLAYMENT

4. SLOPE REQUIREMENT.

CLAY AND CONCRETE ROOF TILE SPECS

4

SHINGLES

15# FELT SHALL BE INSTALLED UNDER ASPHALT SHINGLES. ALL

ASPHALT SHINGLES SHALL HAVE SELD-SEALING STRIPS OR BE

INTERLOCKING AND COMPLY WITH ASTM D 225 OR D 3462, AND

SHALL BE SECURED TO THE ROOF WITH NO LESS THAN 6

FASTENERS PER SHINGLE STRIP, OR A MINIMUM OF 2 FASTENERS

PER SHNGLE TAB, AND SHALL IN NO CASSE BE FASTENED WITH

LESS FASTENERS THAN THAT REQUIRED BY THE MANUFACTURE.

INSTALLATION SHALL COMPLY WITH MANUFACTURES REQUIREMENTS

FOR INSTALLATION IN THE GIVEN FLORIDA WIND ZONE, AS

DETERMINED BY ASTM D 3161.

FASTENERS

FASTENERS FOR ASPHALT SHINGLES SHALL COMPLY WITH ASTM F

1667, AND SHALL BE MADE WITH GALVANIZED STEEL, STAINLESS

STEEL OR ALUMINUM WITH A MINIMUM SHANK SIZE OF 12 GAUGE

(0.105") WITH A MINIMUM 3/8" DIAMETER HEAD SHANK AND SHALL

BE A LENGTH TO PENTRATE THE SHEATHING

THE NAIL COMPONENT OF PLASTIC CAP NAILS SHALL MEET OR EXCEED

THE REQUIREMENTS OF ASTM A 641, CLASS 1, OR EQUAL, AND

SHALL BE CORROSION RESTITANT BY ELECTRO GALVANIZATION,

MECHANICAL GALVANIZATION, HOT DIPPED GALVANIZATION OR

SHALL BE MADE OF STAINLESS STEEL, NON-FERROUS METAL

ASPHALT SHINGLE ROOF SPEC'S

3

R310.2.1 MINMUM OPENING AREA- ALL EMERGENCY ESCAPE AND RESCUE

OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF

5.7 SQUARE FEET (0.530 m2).

EXCEPTION- GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET

CLEAR OPENING OF 5 SQUARE FEET (0.465 m2).

R310.2.1 MINMUM OPENING HEIGHT- THE MINIMUM NET CLEAR OPENING

HEIGHT SHALL BE 24 INCHES (610mm).

R310.2.1 MINMUM OPENING WIDTH- THE MINIMUM NET CLEAR OPENING

WIDTH SHALL BE 20 INCHES (508mm).

R310.1.1 OPERATIONAL CONSTRAINTS- EMERGENCY ESCAPE AND RESCUE

OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM

WITHOUT THE USE OF KEYS OR TOOLS.

R310.2.3 WINDOW WELLS- THE MINIMUM HORIZONTAL AREA OF THE WINDOW

WELL SHALL BE 9 SQUARE FEET (0.84 m2), WITH A MINIMUM HORIZONTAL

PROJECTION AND WIDTH OF 36 INCHES (914mm). THE AREA OF THE WINDOW

WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE

FULLY OPENED.

MINIMUM EGRESS WINDOW DETAIL

1'-8" MIN.

2'-0

" M

IN.

3'-8

" M

AX.

FINISH FLOOR

5.7 SQ. FT.

CLEAR OPENING

R703.4 - WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED BY THE WINDOW

OR DOOR MANUFACTURER OR BY THE FLASHING MANUFACTURER, "PAN FLASHING" SHALL BE

INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL

BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE

EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE.

OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OF PROTECTION AT THE

HEAD AND SIDES.

"PAN FLASHING" IS A GENERIC TERM THAT USED TO REFER TO "METAL PAN FLASHING".

HOWEVER MANY MODERN MATERIALS HAVE BEEN DEVELOPED FOR THE SAME FUNCTION

SUCH AS:

- FLEXIBLE PEEL AND STICK FLASHING MEMBRANE

-FLUID APPLIED FLASHING

FOR SUCH PRODUCTS FOLLOW THE MANUFACTURER'S INSTALLATION REQUIREMENTS

FOR IN-DEPTH FLASHING INSTRUCTIONS, REFER TO THE FOLLOWING PUBLICATIONS:

FMA/AAMA 100

FMA/AAMA 200

FMA/WDMA 250

FMA/AAMA/WDMA 300

INSTALL "PAN" FLASHING AT THE WINDOW SILL

OPENING FOR WINDOW OR DOOR

WHERE "PAN" FLASHING IS

USED AT THE SILL, ALSO

INCORPORATE FLASHING

OR PROTECTION AT THE

HEAD AND SIDES

THE FLASHING INSTRUCTIONS FROM THE WINDOW/ DOOR MFR., OR THE FLASHING MFR.,

SHALL SUPERCEDE THIS DETAIL

PAN FLASHING PER R703.4

SCALE: N.T.S.

WALL SHEATHING

WITH HOUSE WRAP

OR ZIP SYSTEM

WALL SHEATHING

PAPER BACK

METAL LATH

MID WALL

WEEP SCREED

OVER FELT STRIP

MASONRY NAIL

6" WIDE FELT

MASONRY WALL

WOOD FRAMING EITHER

FLOOR TRUSS OR GABLE

END TRUSS

FELT AND

WEEP SCREED

WO

OD F

RAM

EM

ASO

NRY W

ALL

CORNER OF

BUILDING

CORNER BEAD

MITER OUT CORNER

BEAD AT MID WALL

WEEP SCREED

CAULK CENTER JOINT

IN MID WALL WEEP

SCREED 2" IN EA.

DIRECTION AT CORNER

CORNER OF

BUILDING

FULLY EMBED BACK FACE

OF WEEP SCREED IN

CAULK. LET OOZE OUT AT

CORNER AND SCREED 2"

MIN. WIDTH

WIRE LATH

WITH FELT

OVER FRAME

WALL

EXPANSION JOINT

EXPANSION JOINT OVER

WIRE LATH

DECO. TEXTURE FINISH

OVER WIRE LATH

WO

OD F

RAM

EM

ASO

NRY W

ALL

MASONRY WALLMASONRY WALL

DECO. TEXTURE FINISH

OVER WIRE LATH

EXPANSION JOINT

MASONRY WALL

EXPANSION JOINT

AMICO M-TYPE

CONTROL JOINT

AMCJM-780 OR

APPROVED EQUAL

OVER LATH (CUT

LATH BEHIND

CONTROL JOINT 1/4"

MIN. GAP) LOCATE

OVER STUD ONLY

AND PER NOTE 1

*

*NOTE 1:(AT WOOD

FRAME ONLY)

MAX OF 144 SQ. FT.

BETWEEN CONTROL

JOINTS. NOT GREATER

THAN 18'-0" O.C. MAX

AREA RATIO OF

CONTROL JOINTS-2-2/1 TO 1

WIRE THE CONTROL

JOINT TO LATH WITH

18 GA. GALVANIZED

WIRE AT 7' O.C. MAX.

WIRE LATH

OVER FELT

FELT PAPER

FRAME WALL

FELT STRIP

WIRE LATH OVER

MID WALL

WEEP SCREED

OVER FELT STRIPMID WALL

WEEP SCREED

OVER FELT STRIP

MITER OVER SCREED

FELT STRIP

OVER BLOCK WALL

BUILDING

MASONRY WALL

MID WALL WEEP SCREED DETAIL

WEEP SCREED DETAILINSTALL AT ALL EXTERIOR WALL LOCATIONS WHERE

WOOD STUD FRAMING IS ABOVE MASONRY WALLS.

GABLE WALL ROOF

EXTERIOR

ATTICATTICEXTERIOR

HOUSE WRAP

EXTERIOR PLYWOOD W/

RADIANT BARRIER ON

ATTIC SIDE

EXTERIOR STUD

WALL OR TRUSS

RADIANT BARRIER

GLUED TO PLYWOOD

TOP CHORD

RADIANT BARRIER: SCALE: N.T.S.

NOTE: EXTERIOR WALLS ADJACENT TO ATTIC SPACE, INCLUDING KNEEWALLS AND GABLE END WALLS, MUST HAVE

RADIANT BARRIER AND HOUSE WRAP.

8"X8"X16" CONC. BLOCK

CONCRETE FOOTING SEE

FOUNDATION PLAN FOR

SIZE AND REINFORCING.

PRECAST CONCRETE SILL 1/2" DRYWALL W/ TEXTURED WALLS

WOOD BASE

1X2 P.T. FURRING STRIPS @ 24" O.C.

W/ INSULATION (MIN. R4.1)

4" CONC. SLAB ON 6 MIL.

VISQUEEN VAPOR BARRIER ON

MECHANICALLY COMPACTED FILL

@ 95%.

DECO. CEMENT FINISH

PER ASTM C-926

SILL SET IN MORTAR

SEE ENERGY CODE FORMS

FOR INSUALTION R-VALUES

1X4 P.T. STRIP

VENTED SOFFIT

SHALL MEET R703.1.2.1

SEE TABLE 3 ON S-3

DRYWALL CEILING

PER NOTE 9 IN

TABLE 1 ON A-6

GRADE

PROVIDE TERMITE TREATMENT

WITH "BORA CARE".

SLOPE TO EXTERIOR

ROOF SHEATHING PER SCHEDULE 2/S-3.

AND PER NOTES IN TABLE 2 ON A-6

TILE ROOF PER NOTE 4 ON A-6.

OR SHINGLE ROOF PER NOTE 3 ON A-6

EMBEDDED STRAP AT EACH

TRUSS PER ROOF FRAMING PLAN.

FLASHING AND

DRIP EDGE PER NOTES

IN TABLE 2 ON A-6

WINDOW, SEE SCHEDULE AND PLAN.

PRECAST LINTEL

SEE FRAMING PLAN

WINDOW BUCKS SEE TABLE 2 ON A-6

1X4 P.T. BUCK W. BED OF

CONTINUOUS CAULK UNDER

PROVIDE VENTILATION

PER R806.1

8"X8" CONTINUOUS

BOND BEAM W/

1 #5, GROUT SOLID

WOOD TRUSSES @ 24" O.C. (TYPICAL)

DESIGNED BY DELEGATED TRUSS ENGINEER.

2X6 MIN. SUB FASCIA

4"

MIN

.

12"

MIN

.D

W

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

A-6

SECTIONS

# 2

256

E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

Page 7: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

WH

49'-8"

15'-4" 1'-4" 19'-8"

49'-8"

36'-4" 13'-4"

1'-4

"9

'-8

"4

8'-5

"1

'-8

"4

'-0

"

11'-0" 12'-4" 5'-8" 2'-4" 16'-0" 2'-4"

2'-4" 4'-1"

18

'-8

"2

9'-9

"

36'-4" 13'-4"

2'-1" 2'-7" 4'-1" 20'-10" 12'-2" 3'-5" 4'-6"

4'-0" 37'-0 1/2" 8'-7 1/2"

PAVER BY

OTHERS

6" X 12" RECESS

SIN

K &

DIS

P

RUN CONDUIT FOR

ELECTRIC AT ISLAND RANG

E

PROVIDE 1/4" WATER

LINE @ REF. SPACE

FOR ICE MAKER

TIL

E S

HO

WER

RECES

S 3

-1/2

"

5'-0

" TUB

PAVER BY

OTHERSELEV. @ 0'-4"

ELEV. @ 0'-4"

INSTALL 1 3/8" THICK SOID

WOOD DOOR BETWEEN LIVING

AND GARAGE PER FLORIDA

BUILDING CODE R302.5.1

2" SLO

PE

8F8-1B SET AT GARAGE DOOR

HEAD HEIGHT, ADD COURSING AS

REQUIRED TO 8X8 BOND BEAM W/ 1

#5 TOP @ 10'-0". ADD #5 VERT @

48" O.C. GROUT ALL SOLID.

16080 O.H. GARAGE DOOR

ELEV. @ 0'-4"

WASHER

21

'-6

"2

2'-1

"2

1'-6

"

8'-0

"9

'-6

"3

2'-7

"

8" 3'-0" 1'-4 1/2"

21

'-9

"5

'-0

1/2

"

20'-3" 12'-2" 3'-11"

2'-4

"8

'-0

"8

"

METER VERIFY

LOC.

#5 BAR IN GROUTED CELL, LAP

25" WITH #5 DOWEL OUT OF

SLAB, WITH 7" HOOK INTO TOP

OF BOND BEAM

P

F3

F3

P

F3

F3

F3

F3

F3

F3

F3 W

/ C

URB

F3 W

/ C

URB

F3

F3

F6A

F6A

DW

8'-8 1/8"4'-0" 7'-5 1/2" 38'-2 1/2"

STUB OUT FOR

OPTIONAL

OUTDOOR KITCHEN

& SINK

HB

HB

BA

BB

65

'-1

"

A

B

F3

F3

SAWCUTS PER

DETAIL 5/S-3

A A

REF. SPACE

SET A/C PAD ABOVE

FLOOD W/ 1'-0"

FREEBOARD PER

FBCR R322.2.1

LOWEST POINT OF GARAGE SHALL BE SET ABOVE

BASE FLOOD ELEVATION PER FEMA FLOOD MAP

4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #

10/10 W.W.M. REINFORCING OVER 6

MILL VISQUEEN BARRIER ON

MECHANICALLY COMPACTED FILL @ 95%.

THE FINISH FLOOR SLAB SHALL BE SET

ABOVE BASE FLOOD ELEVATION PER FEMA

FLOOD MAP PLUS 1'-0" FREEBOARD PER

FBCR R322.2.1. SEE SITE PLAN BY OTHERS

ELEV. @ 0'-0"

SET W/H ABOVE FLOOD

W/ 1'-0" FREEBOARD

PER FBCR R322.2.1

65

'-1

"

STANDARD SGD RECESS 1-1/2".

IMPACT GLASS SGD RECESS 2-1/2".

STANDARD SGD RECESS 1-1/2".

IMPACT GLASS SGD RECESS 2-1/2".

PROVIDE TERMITE TREATMENT

WITH "BORA CARE"

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN.

2 #5 CONT. W/

3" CLEAR COVER.

1'-0"

1'-0"

MIN

.

2'-1

"

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN. BELOW

GARAGE FLOOR

2 #5 CONT. W/

3" CLEAR COVER.1'-0"

1'-0"

MIN

.

7 5/8"

.

VARIES WITH

SLOPE OF FLOOR

CURB IS OPTIONAL & NOT INCLUDED

IN FOOTING DIMENSIONS

2'-1

"

8"X8" CONC. RIBBON

W/ 1 #5 ROD CONT.

1" 3"

8"

8"

PAVERSMORTAR

TYPE LENGTH WIDTH DEPTH

CONT. 1'-4"

1'-8"

1'-0"

1'-4"

1'-4"

F1

F2

F3

F4

F5

1'-8"

1'-0"

1'-0"

2-#5

SHAPE

WALL FOOTING SCHEDULE

US

ED BOTTOM

REINFORCING

F6

F6A

TE

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

1'-4"

0'-8"

0'-8" 0'-8"

0'-8"

1'-8"

0'-10"

0'-8"

2-#5

2-#5

2-#5

2-#5

2-#5

1-#5

1-#5

ADD CURB TO

GARAGE, SEE

DETAIL

PROVIDE CORNER BARS PER 6

TYPE LENGTH WIDTH DEPTH

2'-6" 2'-6"

3'-0"3'-0"

3'-6"3'-6"

4'-0"4'-0"

5'-0"5'-0"

A

B

C

D

E

1'-0"

1'-0"

1'-0"

1'-2"

1'-2"

3-#5 3-#5

4-#5 4-#5

4-#5 4-#5

5-#5 5-#5

6-#5 6-#5

-

-

-

-

-

REMARKSLONG WAY SHORT WAY

BOTTOM REINF.

PAD FOOTING SCHEDULE

US

ED

FOUNDATION PLAN

PLAN NOTES:

1. TOP OF GROUND FLOOR SLAB DATUM ELEVATION 0'-0"

2. "F#" DENOTES CONTINUOUS WALL FOOTING TYPE PER SCHEDULE THIS SHEET.

3. # DENOTES PAD FOOTING AT CONCENTRATED LOADS PER SCHEDULE THIS SHEET.

4. PROVIDE #5 VERTICAL REINFORCING AT DOT LOCATIONS SHOWN ON PLAN FROM FOOTING

TO BOND BEAM.

5. ALL DIMENSIONS ARE TO OUTSIDE FACE OF MASONRY WALLS. SOME SLAB EDGES MAY

EXTEND BEYOND FACE OF WALL.

6. FOR DIMENSIONS OF ROUGH OPENINGS IN MASONRY WALLS, COORDINATE WITH WINDOW/

DOOR SUPPLIER.

7. PROVIDE PRESSURE TREATED BUCKS AT WINDOWS/ DOORS PER DETAIL 7/S-3.

SCALE: 3/16" = 1'-0"

6"

10

"

GRADE

4" CONC. SLAB

(2) #5 RODS

CONT.

1'-0"

RECESS

3" CLEAR COVER1 #5

8"

8"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

S-1

FOUNDATION PLAN

# 2

256

E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

1/4" = 1'-0"

FOUNDATION PLAN

1/2" = 1'-0"

"F3" FOOTING

1/2" = 1'-0"

"F3" WITH CURB AT GARAGE

1/2" = 1'-0"

"P" PAVERS DETAIL ENTRY/ LANAI

1/2" = 1'-0"

GARAGE DOOR RECESS1/2" = 1'-0"

"F6A" STEP DOWN

Page 8: MODEL # 2256 E · model # 2256 e 09/15/19 addrs: enter address here gcd job # 1/4" = 1'-0" slab & plumbing plan. wh plan notes 1) verify all rough opening dimensions for all windows

WH

B2

B3

B4

B5

A13

A12

A11

A10

A9

A8

A7

A6

A5

A4

HJ7 HJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

HJ7 H

J7

A2

A2

A1

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

B1

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

F1

HJ7

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

MG1

EJ7

EJ7

EJ7

D1

D2

D3

HJ5

HJ5

CJ1

CJ3CJ1

CJ3A

CJ1

CJ3

EJ5

EJ5

EJ5

EJ5

A12A

A11A

A10A

A9A

A8A

A7A

A6A

A5A

A4A

A3

A1

CJ1

CJ3

M1

M1

M1

M2

M2

M2

M2

M2

M3

RID

GE

RID

GE

RID

GE

HIP HIP

HIP

HIP

HIP

HIP

HIP

HIP

VAL

LEY

10'-0" FLAT CEILING

MASTER

SUITE

BEDROOM #2

BEDROOM #3

2 CAR GARAGE

DINING ROOM

GREAT ROOM

KITCHEN

LAUNDRY

LANAI

ENTRY

W.I.C.

BATH #2

MASTER

BATH

FOYER

PANTRY

RID

GE

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING 10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

10'-0" FLAT CEILING

#5 VERTICAL @ DOT LOCATION (48" O.C. MAX)

IN GROUTED CELL W/ 7" HOOK INTO BOND BEAM

8"X8" CONTINUOUS MASONRY BOND BEAM AT

TOP OF WALL. WITH 1 #5 BAR. PROVIDE CORNER

BARS PER 8/S-3

SEE DETAIL 9/S-3 WHERE LINTEL

AT LANAI/ENTRY INTERSECTS

MAIN WALL, TYPICAL

8F8-0B

8F8

-0B

8F16-1B/1T

EXTERIOR CEILING

PER 2/S-3

8F8-0B

8F8-0B 8F8-1B

8F8-0B

8F8-0B8

F8

-0B

8F8

-0B

8F8

-0B

8F8

-0B

8F16-1B/1T

8F8

-1B

8F16-1B/1T

COFFERED CEILING

COFFERED CEILING

COFFERED

CEILING

COFFERED

CEILING

GARAGE SHALL BE SEPERATED FROM THE

RESIDENCE & ATTIC BY NOT LESS THAN 1/2"

GYPSUM BOARD APPLIED TO THE GARAGE SIDE.

GARAGES BENEATH HABBITABLE ROOMS SHALL

BE SEPERATED WITH NOT LESS THAN 5/8" TYPE

"X" GYPSUM BOARD OR EQUIVALENT. WHERE THE

SEPERATION IS A FLOOR-CEILING ASSEMBLY THE

STRUCTURE SUPPORTING THE SEPERATION

SHALL ALSO BE PROTECTED BY NOT LESS THAN

1/2" GYPSUM BOARD OR EQUIVALENT.

8F8-1B SET AT GARGAE DOOR

HEAD HEIGHT, ADD COURSING AS

REQUIRED TO 8X8 BOND BEAM W/

1#5 TOP @ 10'-0". ADD VER @

48" O.C. GROUT ALL SOLID.

12'-0" CEILING

HIP HIP

VAL

LEY

8F8

-0B

8F8

-0B

W.I.C.10'-0" FLAT CEILING

8F1

6-1

B/1

T

8F8

-0B

10'-0" FLAT CEILING

1-HTA16-18

@ A13

WHERE ROOF SHEATHING CONTACTS

ONLY THE EDGE OF ROOF TRUSSES,

INSTALL BEVELLED BLOCKING PER

DETAIL THIS SHEET ( DR HORTON

REQUIRMENT )

+31.2 -41.8

+31

.2 -

41

.8

1-HTT45 @ A13 W/ 5/8" Ø

ALLTHREAD, DRILL & EPOXY

12" MIN. EMBED

1-HTA16-18

@ A13

+27

.6 -

31

.2

1-HTA20

+27.6 -31.2+31.2 -33.8

(+31.2 -33.8) WIND

PRESSURES PER ASCE7-10,

170 MPH, EXPOSURE B, AND

CONVERTED TO ALLOWABLE

STRESS DESIGN PRESSURES

USING 0.6W LOAD FACTOR.

(Vasd= 124 MPH, RISK CAT II,

ENCLOSED, kd=0.85, H<30'

+31

.2 -

33

.8+

31

.2 -

33

.8

1-HTA16-18

TYPICAL

+31

.2 -

33

.8+

31

.2 -

33

.8

1-HTA16-18

TYPICAL

+31

.2 -

33

.8

+31.2 -41.8

+31.2 -33.8 +31.2 -33.8

8F8-0B

+31.2 -33.8

1-HTA16-18

@ MG1

+26.4 -29.4

8F8-1B

1-HTA16-18

@ B1

TRUSS STRAPPING TO STUDWALL/ WOOD BEAM

MAX TRUSS UPLIFT

@ 24" OC (LBS)CONNECTOR FASTENER

1005

2010

3015

1285

2570

3855

5140

(1)MTW16

(2) MTW16

(3) MTW16

(1) HTW20

(2) HTW20

(3) HTW20

(4) HTW20

12-10dX1~1/2"

12-10dX1~1/2"

12-10dX1~1/2"

24-10dX1~1/2"

24-10dX1~1/2"

24-10dX1~1/2"

24-10dX1~1/2"

INSTALL AT ALL

TRUSSES TO

1005 lb UPLIFT.

FOR HIGHER

UPLIFTS, SEE

NOTES ON

PLAN.

NOTES:

1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING

POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED

TRUSS DESIGN PACKAGE.

2. CONNECTORS ARE USP STRUCTURAL CONNECTORS. ALL CONNECTORS

SHALL BE INSTALLED IN STRICT ACCORDANCE WITH USP PRINTED

INSTUCTIONS. REV2

TRUSS STRAPPING TO MASONRY

MAX TRUSS UPLIFT

@ 24" OC (LBS)CONNECTOR FASTENER

1615

1870

2430 (1 PLY)

2800 (2 PLY)

3170 (2 PLY)

5005

(1) HTA16-18

(1) HTA20

(2)HTA16- 18

(2)HTA16 -18

(2) HTA20

HTT45

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx 1/2", EMBED 4"

5/8"ø ATR, EPOXY 12"

INSTALL HTA

16-18 AT ALL

TRUSSES TO

1615 lb UPLIFT.

FOR HIGHER

UPLIFTS, SEE

NOTES ON PLAN.

NOTES:

1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING

POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED

TRUSS DESIGN PACKAGE AND SUITABLE FOR THE GEOMETRY. EMBED STRAP

ON -C/L OF WALL.

2. CONNECTORS ARE USP STRUCTURAL CONNECTORS. ALL CONNECTORS

SHALL BE INSTALLED IN STRICT ACCORDANCE WITH USP PRINTED

INSTUCTIONS. SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE

ENGINEER OF RECORD.

3. WHERE EMBEDDED STRAPS ARE MISSING, OR MIS-LOCATED, INSTALL

RETROFIT STRAP PER 2/S-4.

4. ' ATR' = ALLTHREAD. DRILL AND EPOXY WITH USP EPOXY PER MFR.

INSTRUCTIONS. REV2

WALL ABOVE WITH BOND

BEAM AT TOP

#5 VERTICAL, ABOVE

LINTEL ONLY WHERE

NOTED ON PLAN

'1B' DENOTES 1#5 BOTTOM

WITH 7" HOOK EACH END OR

EXTEND 24" BEYOND OPENING.

'0B' DENOTES "NO REBAR"

8" PRECAST LINTEL

GR

OU

T S

OLID

1'-4"

GR

OU

TE

D

1#5 TOP

1#5 BOTTOM

8F8-1B

8F8-0B

8F16-1B/1T

PRECAST LINTEL SCHEDULE

AT SWING DOORS, USE 2" RECESS STYLE

LINTEL IF NEEDED FOR ROUGH OPENING.

LINTELS BEAR 4" MIN. EACH END

PLAN NOTES:

1. ROOF AND FLOOR TRUSS BEARING ELEVATION VARIES,

SEE LEGEND.

2. ROOF AND FLOOR FRAMING SHALL BE WOOD TRUSSES

DESIGNED BYA DELEGATED TRUSS ENGINEER PER

DESIGN CRITERIA ON SHEET S-3.

3. PROVIDE STRAPPING AT TRUSSES PER NOTES ON THIS

SHEET.

4. FOR NAILING OF ROOF AND FLOOR DECK, SEE 1 AND 2

ON S-3.

5. 8F8-1B etc., DENOTES PRECAST LINTEL ABOVE

DOOR/WINDOW OPENING PER SCHEDULE THIS SHEET.

6. AT TRUSS BEARING, PROVIDE 8x8 MASONRY BOND

BEAM W/ 1 #5 CONTINUOUS, SEE DETAIL 11/S-3.

7. "SW" DENOTES PLYWOOD SHEARWALL PER SCHEDULE

THIS SHEET.

BEARING HEIGHT

= BEARING @ 10'-0"

= BEARING @ 12'-0"

ROOF SHEATHING

8d RING SHANK @

6" O.C.

16d NAILS

@ 8" O.C.

2" X () BLOCKING W/

BEVEL CUT TOP

ROOF TRUSS

BEVELLED BLOCKING DETAIL

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\M

ODELS

\2256 E

\REVIT

\2256 E

.rvt

S-2

ROOF FRAMING PLAN

# 2

256

E

MO

DEL

09/15/19

AD

DRS:

Ente

r addre

ss h

ere

GC

D J

OB #

1/4" = 1'-0"

ROOF FRAMING PLAN

TRUSS BEARING CONDITIONS AND STRAPPING IS

BASED ON TRUSS LAYOUT PREPARED BY BUILDERS

FIRST SOURCE, JOB# MASTER DATED: 03/27/18

REVISED: NONE