7
Summary Module ID: 668111210252051 Manufacturer: Amerisolar Module Type/Description: AS-6M30-250W Testcenter Serial: 2007_Franka Module Judgement: CLASSC Job ID: 2015-10-05 Bjerringbro Address: Michael Hvitfeldt / Mikkelsgade 16 Country / City: DK 8850 Bjerringbro Power Pmpp @ STC IEC60891: 239.1W Power missmatch: -4.4% to 250.0W ( 0.0%->+3.0% ) Tmod / Tref: 14.0C / 19.8C Flash Time: 93.5ms Flasher Parameter: C14200N/Mono/175s Operator / Date Time: André Brunk 10/5/2015 4:05 PM Connection Check Status: Successfull 8.7A 42.2V Electroluminescence Cell Judgement Count: 0 sehr kritisch: >=20% Zellfläche betr. 3 kritisch: <20% Zellfläche betr. 4 unkritisch: keine Zellfläche betr. 0 andere EL Auffälligkeiten No Judgment Count: 53 EL Parameter: 8.0s / 44.6V / 13.1A / Cell / Assisted Operator / Date Time: André Brunk 10/5/2015 4:05 PM Reviewer / Date Time: André Brunk 10/5/2015 4:07 PM Comment Operator / Date Time: André Brunk 10/5/2015 4:06 PM Modul13 MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 1

Transcript of Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 ›...

Page 1: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:

Summary

Module ID: 668111210252051Manufacturer: AmerisolarModule Type/Description: AS-6M30-250WTestcenter Serial: 2007_FrankaModule Judgement: CLASSC

Job ID: 2015-10-05 BjerringbroAddress: Michael Hvitfeldt / Mikkelsgade 16Country / City: DK 8850 Bjerringbro

PowerPmpp @ STC IEC60891: 239.1WPower missmatch: -4.4% to 250.0W ( 0.0%->+3.0% )Tmod / Tref: 14.0C / 19.8CFlash Time: 93.5msFlasher Parameter: C14200N/Mono/175sOperator / Date Time: André Brunk 10/5/2015 4:05 PM

Connection CheckStatus: Successfull 8.7A 42.2V

ElectroluminescenceCell Judgement Count: 0 sehr kritisch: >=20% Zellfläche betr.

3 kritisch: <20% Zellfläche betr.4 unkritisch: keine Zellfläche betr.0 andere EL Auffälligkeiten

No Judgment Count: 53EL Parameter: 8.0s / 44.6V / 13.1A / Cell / AssistedOperator / Date Time: André Brunk 10/5/2015 4:05 PMReviewer / Date Time: André Brunk 10/5/2015 4:07 PM

CommentOperator / Date Time: André Brunk 10/5/2015 4:06 PM

Modul13

MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 1

Michael
Fremhæv
Michael
Fremhæv
Michael
Fremhæv
Page 2: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:

Power

Module ID: 668111210252051Type ID: Amerisolar / AS-6M30-250W

Pmpp[W] Impp[A] Umpp[V] Isc[A] Uoc[V] Irr[W/m2] FF[%]IEC60891 STC 239.1 8.02 29.81 8.59 37.22 1000.0 74.8Measured 216.9 6.92 31.35 7.50 38.28 922.0 75.5

Tmod[C]:14.0 Tref[C]:19.8 Tdev[C]:20.1 Tout[C]:16.6 T[ms]:93.5Type:Mono alpha[%]:0.056 beta[%]:-0.330 IEC aICF:0.060 IEC Rs:0.54Software:365p

MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 2

Page 3: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:

Electroluminescence for 668111210252051

Current/A: 13.097 Voltage/V: 44.591Exposure Time [ms]: 8000 André Brunk 10/5/2015 4:05 PM

MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 3

Page 4: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:

EL details for 668111210252051

EL Image of Cell (2/3)

kritisch: <20% Zellfläche betr.EL Image of Cell (2/4)

unkritisch: keine Zellfläche betr.

MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 4

Page 5: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:

EL details for 668111210252051

EL Image of Cell (3/2)

kritisch: <20% Zellfläche betr.EL Image of Cell (4/2)

unkritisch: keine Zellfläche betr.

MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 5

Page 6: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:

EL details for 668111210252051

EL Image of Cell (4/4)

unkritisch: keine Zellfläche betr.EL Image of Cell (5/9)

kritisch: <20% Zellfläche betr.

MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 6

Page 7: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:

EL details for 668111210252051

EL Image of Cell (6/8)

unkritisch: keine Zellfläche betr.

MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 7