Principles of Mobile Radiography
You bring imaging services to pt using transportable x-ray equipment
Where are they commonly used?
pt room
ER
ICU
surgery and recovery rooms
nursery and neonatal units
When was mobile x-ray equipment first used?
battlefield WW1 -units were carried to field sites
![Page 3: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/3.jpg)
Mobile X-Ray Machines
• True or false? Portables are as sophisticated as stationary units?– False
• Typical unit has what 2 controls? – kVp and mAs
• What is the mAs range?
– Generally 0.04 to 320 mAs
What is the kVp range?
-generally 40 to 130 kVp
![Page 4: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/4.jpg)
Two basic types of Mobile X-Ray Machines
1. Battery powered• Uses two different sets of batteries (lead-acid, or nickel-cadmium )
– One powers driving of machine– One set provides power to x-ray tube
• Fully charged batteries:
- can make 10 to 15 exposures
- be driven reasonable distances
2. Capacitor discharge (obsolete)
• No batteries
• Carries two metal plates that hold electrical charge
• Capacitor units must be charged prior to each use
![Page 5: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/5.jpg)
Battery-operated Unit
Advantages:– Cordless
– Provide constant kVp and mAs
Disadvantages:- Heavy
- hard to control
What is “Deadman” type of brake?
– stops machine instantly when push-handle released
![Page 6: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/6.jpg)
Capacitor Discharge Units
Advantages?
lightweight, smaller and easier to maneuver
require much less time to charge than battery units
Disadvantages?
can’t handle thick body parts due to voltage drop during exposure
must be charged prior to each use
![Page 7: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/7.jpg)
The Nomad
For places with no electricity or chemical processors
Mainly for dental x-rays
![Page 8: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/8.jpg)
3 important technical factors that must be clearly understood to perform optimum mobile examinations:
Grid
Anode-heel effect
Source–to–image receptor (SID)
![Page 9: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/9.jpg)
GridMust be level!
X-ray beam must be properly centered to grid
Correct focal distance must be used
(Best grids for mobile radiography have ratios of 6:1 or 8:1 and a focal range of 36 - 44 inches)
Make sure grid is fastened to cassette properly (tape)
![Page 10: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/10.jpg)
Anode Heel Effect
• Correctly place anode-cathode (marked on tube housing) with respect to anatomy
– Anode should be on thinner part (T-spine)
• Heel effect increases with short SID, larger field sizes (more common in mobile radiography)
Beam travels through thicker part of target on anode side, thus attenuating beam more
![Page 11: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/11.jpg)
SID- Mobile Units
What is standard SID?
40
Possible problems with greater SID?
Need increased mAs, thus longer exposure timeIncreases risk of imaging motion
Increased drain on battery
Possible grid cut-off
![Page 12: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/12.jpg)
Performing Mobile Examinations
Plan ahead!
Gather all necessary devices to take with you
IR (bring extras!)GridTapeMarkersSponges
![Page 13: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/13.jpg)
Before Beginning Examination
• Find pt’s x-ray order
• Let nurse’s station know of your presence and purpose
• Identify pt and introduce yourself with your title
• Explain exam and ensure it is appropriate and correct
• Politely ask any visitors to leave
• Obtain assistance when necessary!
![Page 14: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/14.jpg)
Interfering Devices
• Watch out for orthopedic beds, fracture frames, tubes, wiring, etc., producing artifacts
• Know which objects can be moved and which ones you have to work around
• May have to perform with object in image
• Ask if unsure whether an object can be moved
![Page 15: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/15.jpg)
Portable Position
• If exam in supine position, move base of machine to middle of bed
• If seated upright, base at end of bed
• Lateral and decubitus positions, place base parallel or perpendicular to bed
![Page 16: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/16.jpg)
Performing Mobile Examinations
Make sure collimation is not open larger than IR size
Check CR and IR alignment to prevent distortion
Use consistent system for keeping exposed and unexposed IRs separate
Keep log of procedures, time of examination, technical factors for image ID
![Page 17: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/17.jpg)
Technique Charts and Logs
Exposure for optimum exam!
Should be available for every machine
Should display standard technical factors for all projections performed with machine
Logbook of all recent pt exams and technique
Caliper should also be available for accurate patient measurement
![Page 18: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/18.jpg)
Scatter Radiation and Mobile Radiography
![Page 19: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/19.jpg)
Mobile radiography produces some of highest occupational radiation exposure for radiographers!
Wear a lead apron!
Wear film badge at collar or waist outside lead protection
What is single most effective radiation protection measure?
Distance!
What is minimal safe distance ? 6 feet
![Page 20: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/20.jpg)
Safest Place to Stand
Least exposure is at what angle to pt and primary beam?
Right angle
![Page 21: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/21.jpg)
When should you shield pt’s gonads?
– X-raying children
- Person is of reproductive age
– Pt requests
– Gonads lie in or near useful beam
– When shield will not interfere with anatomy of interest
![Page 22: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/22.jpg)
Radiation Safety cont’d
What is minimum source-to-skin distance? – 12
Have visitors leave area
Warn other personnel when you are about to make an exposure
![Page 23: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/23.jpg)
Patient Mobility
Never move pt or part without:
Assessing ability to move or ability to tolerate movement
Checking with staff obtain assistance and permission to move a part that has had surgery or fractured
Inappropriate movement can further injure pt!
![Page 24: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/24.jpg)
Warn pt of potential discomfort from IRCold
Hard
IR can damage skin of older patientUse cloth or paper cover to reduce risk of injury
Protect IR from contamination by use of appropriate impermeable cover
![Page 25: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/25.jpg)
Assess Patient Condition
Be aware of any limitations to procedure!
• Alertness
• Respiration
• Ability to cooperate
• Language comprehension
• Mobility
• Fractures
• Interfering devices
If in OR, don’t break sterile field!
![Page 26: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/26.jpg)
Isolation Considerations
What are two types of pts in isolation?
Those who have contagious infectious microorganisms
you want to avoid them!
Those who must be protected from exposure to infectious microorganisms-
they want to avoid you! This known as?
Reverse isolation!
![Page 27: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/27.jpg)
Isolation Considerations cont’d
• Wear all required protective apparel for specific situation
• Wash hands before gloving
• Protect IR with protective cover
![Page 28: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/28.jpg)
Isolation Considerations cont’d
After procedure:
Discard of protective apparel according to protocol
Wash hands!
Wear clean gloves to clean equipment and use appropriate aseptic technique
Wash hands again after removing gloves
![Page 29: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/29.jpg)
Most Common Portable Radiographic Exams
• Chest
• Abdomen
• Pelvis
• Femur
• Cervical spine
• Neonate
![Page 30: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/30.jpg)
AP Chest
• Elevate head of the bed as pt condition permits
• Pull pt to head of bed before elevating if condition permits
• Make sure pt is not rotated
What if pt has respiration assistance?
• watch pt chest to determine inspiratory phase (or respirator)
![Page 31: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/31.jpg)
AP or PA Chest
Lateral Decubitus Position
• Place firm support under pt to elevate body and keep pt from sinking down in bed
• Protect pt from rolling off of bed!
![Page 32: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/32.jpg)
Lateral Decubitus Position Considerations
• Fluid levels best imaged with?– affected side down
• Air levels seen best with?– affected side up
• How long should pts be in this position before exposure?– 5 minutes
• Why?– to allow fluid or air to settle
![Page 33: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/33.jpg)
Orthopedic Examinations
How many images required? at least 2 films at right angles to each other
Who do you obtain permission from prior to moving an injured pt?pt’s nurse or physician
How do you position pts? very carefully!
![Page 34: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/34.jpg)
Lateral Cervical Spine
– Dorsal decubitus position
– CR horizontal
– If there is a immobilization device when should you remove it?
• NEVER or until Dr. gives permission
![Page 35: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/35.jpg)
Neonate
• Move arms out of anatomy of interest
• Bring legs down
• Who should hold infant in position?• Nurse- (provide lead apron)
• Why do you leave head rotated?– to avoid advancing endotracheal tube too far
• Collimate closely
• Shield gonads
![Page 36: Mobile Radiography (Portables) 8/29/2012 Class ed.](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649cbf5503460f949843f3/html5/thumbnails/36.jpg)
Neonate
• AP projection of chest and abdomen often ordered and shot in one exposure
• Infant is supine
• Some bassinets equipped with tray to hold IR
• If IR placed directly under infant- wrap with soft cover