MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58,...

10
1 Military market - Filotex® Military market - Filotex® NEXANS AND THE DEFENCE MARKET Nexans presents a complete range of cables for Military equipment. Used in various applications (airborne, on the ground and under water), Nexans has developed expertise and experience in a very narrow specialized market. MILITARY CABLES A COMPLETE RANGE OF CABLES From hook-up wires to coaxial and multicoaxial cables; Copper, aluminium or optical fiber cables; Specific cables, armoured or unarmoured; Nexans covers all applications for Military equipment. STANDARDS AND SPECIFICATIONS Nexans cables strictly conform to international and military specifications e.g. SEFT027, MIL C 17, NF C 32070 C1/ C2, NF C 93550, IEC 60332 1/2/3, IEC 60331, OTAN 6145 standards. They can also be approved by Bureau Veritas and Lloyd. They can conform to other standards according to the requirements (BS, VG, MIL...). Our Research and Development department creates specific cables to meet customer needs regarding the chemical, mechanical and electrical properties of the cables. MAIN CHARACTERISTICS Cables available in every type of construction, well-adapted to harsh and hostile environments (from -90°C to +260°C, and even +350°C for aeronautical fire resistant cables) which are designed to meet stringent chemical, mechanical and/or electrical properties. Very flexible, this cables can be used with operating voltage up to 3700 volts. From -90°C to +260°C Flexible

Transcript of MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58,...

Page 1: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

1

Military market - Filotex®Military market - Filotex®

NEXANS AND THE DEFENCE MARKET

Nexans presents a complete range of cables for Military equipment. Used in various applications (airborne, on the ground and under water), Nexans has developed expertise and experience in a very narrow specialized market.

MILITARY CABLES

A COMPLETE RANGE OF CABLESFrom hook-up wires to coaxial and multicoaxial cables;Copper, aluminium or optical fiber cables;Specific cables, armoured or unarmoured;Nexans covers all applications for Military equipment.

STANDARDS AND SPECIFICATIONSNexans cables strictly conform to international and military specifications e.g. SEFT027, MIL C 17, NF C 32070 C1/C2, NF C 93550, IEC 60332 1/2/3,IEC 60331, OTAN 6145 standards. They can also be approved by Bureau Veritas and Lloyd. They can conform to other standards according to the requirements (BS, VG, MIL...).Our Research and Development department creates specific cables to meet customer needs regarding the chemical, mechanical and electrical properties of the cables.

MAIN CHARACTERISTICSCables available in every type of construction, well-adapted to harsh and hostile environments (from -90°C to +260°C, and even +350°C for aeronautical fire resistant cables) which are designed to meet stringent chemical, mechanical and/or electrical properties.Very flexible, this cables can be used with operating voltage up to 3700 volts.

From -90°C to +260°C

Flexible

Page 2: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

Military market - Filotex®Military market - Filotex®

2

Hook-up wires in pressurized (fuselage, passenger area, cockpit) and non pressurized (wings, landing gear, antenna) areas

APPLICATIONS

Military aircraft,On-board equipment and weapon systems,Ground interface.

CABLES FOR AERONAUTICAL

AIR 4524 (1806, 806)AIR 4524 (2100, 1100)ASNE, NSA, ABS (Airbus, ATR, Eurocopter…)BS G 222 (EFGLAS)BS 3G 210EN 2266, 2267, 2713, 2714JN (Eurofighter)

MIL W 16878/4 - 13MIL W 22759/5 – 27, 32 – 46, 80 - 92MIL DTL 81044 / 5 - 13PANAVIA (Tornado) – PAN 6411-6412S 3200 (Bae)DEFSTAN 33/001 & 008

Fire resistant and high temperature cables for engine and nacelles

AIR 4527 (3000A; 3100)ASNE (Airbus, ATR, Eurocopter…)EN 2346EN 4608BMS 13-55, BMS 13-58, BMS 13-67 (Boeing)ESW: Fireproof and filter cables (Rolls Royce)

MIL W 25038MIL DTL 27500RMS (Rohr)TMF 340: 300 to 340°C operating temperatureXB 3627 - 9310 (SNECMA)Thermocouple cables

Power cables for power supply unitNSA 935308 YUASNE 0438 YV

ABS 0949, ABS 1354 ADESW 1000

Coaxial cables and databus for HF transmission (radio/radar systems, anti-collision systems, avio-nic systems and satellite communications)

MIL C17 (ex RG)EN 4604PAN 6422SFX 142ABS 1503 KD 24

ABS 1580 KH 24ABS 0386 WFECS 0758 KF 24PAN 6421 EN 3375

Optical cablesABS 0963-003 LF Cables to customer specifications

Cables for specifics uses

Flight test wires : ASNE (Airbus, Eurocopter…)Thermocouple extension : MBBN 3320 YH/EN 4049Low noise cables : NSA (Airbus), Vibrometer, ESWCable assemblies : SATCOM, T-CASExtensible cables: ASNE, ABS, ECSCables to customer specifications

Page 3: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

3

Military market - Filotex®Military market - Filotex®

CABLES FOR NAVY

Surface vessels (frigates, aircraft carriers, etc.),Submarines.

APPLICATIONS

Hook-up wires

Flamex (halogen free)NF C 93521 (KY / EPDX)NF C 93524 (KU)MIL W 16878/4-28

MIL W 22759/5-31, 32-46MIL DTL 22759/80-92MIL DTL 27500

Multipair and multiconductor cables

Standard multiconductors (SMA, SMBL, GRTH) with or without halogen.

Special multiconductors :- Shielded or unshielded halogen free multipairs with or without individual screen for data transmission in electronic equipment (2 to 21 pairs, or more on request, in 0.22, 0.34 or 0.75 mm² cross sections); approved by Bureau Veritas (Example 1).

- Halogen free multiconductors in low, medium and high voltage links (conductors in 0.15 to 120 mm² cross sections) with or without indivi-dual screen. Cables available in every type of construction : monoconductor, multipair, triple, quad, etc. (Examples 2 and 3).

Example 1 : Et. 2PC91818 shielded and jacketed pairs with individual screenOperating temp.: -30°C to +105°COperating voltage : 250 volts

1- Shielded pair in tinned copper, insulation and jacket halogen free2- Polyester tape3- Halogen free tape4- Tinned copper braid5- Outer jacket : halogen free ∅ 29 mm

1

2

3

4

5

Example 2 : Et. 2PE0987 shielded and jacketed triples with individual screenOperating temp. : -30°C to +105°COperating voltage : 175 / 300 volts

1- Triples in tinned copper conductor + insulation halogen free2- Tinned copper braid3- Polyester tape4- Halogen free jacket ∅ 20.50mm (in accordance with A014000 specification)

1

2

3

4

Example 3 : MPRXCX FLEX SHF2Flexible cables for fixed installation

1- Core : flexible bare copper, class 52- Insulation PR3- Polyolefin inner covering4- Armouring bare copper braid5- Outer jacket polyolefin SHF2

Page 4: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

Military market - Filotex®Military market - Filotex®

4

MIL C 17 (ex: RG)NF C 93550Flamex KX/RG (halogen free)Low noise coaxial cables (CAS, KX, RG) Halogen free shielded and jacketed coaxial cables, approved by Bureau VeritasTriaxial cables (Example 3)

Coaxial cables and multicoaxial cables

CABLES FOR NAVY

Coaxial cables for navy :- For underwater specific applications: Et. 268414 (basic model) and Et. 268565 (reinforced model) for guided underwater vehicle - mine detection - (Example 1).- Halogen free ethernet coaxial cables: Et. 382203 («backbone» cable), Et. 276659 (for ethernet transceiver), etc.- Sonar cables (Example 2)

Nexans supply a range of cables for underwater vehicles.

Example 1 : Et. 268565Cable for data transmission in underwater vehiclesHigh mechanical resistanceHigh flexibility

1- Conductor in bare copper2- Dielectric: foam insulation3- Aramid fillers4- Bare copper braid5- PVC jacket

Example 2 : Et. 124415Sonar cableOperating temp. : -55°C to +90°C

1- Tinned copper conductor2- Insulation: elastomer3- Tinned copper braid4- Inner jacket5- Aramid braid6- Polyester tape7- Halogen free jacket

Example 3 : Et. 287515Triaxial cable 50 ΩData transmission for navy applicationsCable for noise measurment sensor (vibration measurment) in a submarineHigh resistance to water pressure and tensile strengthOperating temp.: -20°C to +80°C

1- Tinned copper conductor2- Dielectric: polyethylene3- Tinned copper braid4- Inner jacket: polyethylene5- Tinned copper braid + tape + aramid braid6- Halogen free outer jacket

2

3

4

5

1

2

3

4

5

1

1 2 3 4 5 6

1

234567

1

234567

Data cablesDatatactic® copper for links in communication systems: 150/600 MHz reinforced databus cable. These cables are available in halogen free version and are approved by Bureau Veritas (Example Et 2PC853).

Example : Et. 2PC853 Datatactic® copper Operating temp. : -20°C to +70°C

1- 4 pairs - Red copper conductor - Insulation polyolefine - Individual shielded by pair with a polyester/aluminium tape 2- Tinned copper braid 3- Ripcord 4- Halogen free inner jacket 5- Halogen free outer jacket

2

1

3

4

5

2

1

3

4

5

Page 5: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

5

Military market - Filotex®Military market - Filotex®

Example 1 : Et. 70344 Et. 77472Antenna cable for submarinesHigh mechanical resistance

1- Aramid fiber2- Copper braid3- Polyethylene jacket4- Polyethylene jacket

Example 2 : Et. 279458Strictly halogen free cablesOperating temp. : -40°C to +80°COperating voltage : 500 volts

1- Lay up of composite multipairs with or without shielded2- 4- 6- Separator tapes3- 7- Halogen free jacket5- Tinned copper braid

CABLES FOR NAVY

Nexans supply cables for antennas and special cables in submarines.

Special cables

Antennas for submarines (Example 1)Torpedo cables (Example 2)

Optical cablesOptical cables for wire guided missileOptical cables for underwater vehicle (Example 1)Other special multifibres :- Halogen free optical multifibers for navy applications (monomode or multimode) approved by Bureau Veritas (Example 2)

- Halogen free multi-patchs (2, 4, 6, 8, 12 optical fiber) with mechanical reinforcement (Example 3). Application: future optical networks in ships for navy. Higher bandwidth and longer transmission distance.These cables are approved by Bureau Veritas.

Example 1 : Et. 385302Optical fiber for wire guided missile

1- Optical fiber 62.5/125 μm + jacket 2- Aramid braid3- PVC jacket

Example 2 : Et. 2PE89924 monomode optical fiber with mechanical reinforcementOperating temp. : -25°C to +70°C

1- Optical fiber 62.5/125 μm + halogen free jacket + aramid yarn2- Halogen free filler 3- Polyester tape4- Reinforcement: braid of aramid yarn5- Halogen free jacket

Example 3 : Et. 2PC90812 optical fiberOperating temp. : -25°C to +75°C

1- Optical fiber 62.5/125 μm + halogen free jacket + aramid yarn2- Polyester tape3- Halogen free jacket

1

2

3

4

1

2

3

4

1

2

3

4

5

6

7

1

2

3

4

5

6

7

12

3

12

3

2

1

3

4

5

2

1

3

4

5

1

2

3

1

2

3

Page 6: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

Military market - Filotex®Military market - Filotex®

6

CABLES FOR GROUND FORCES

Armoured vehicles, shelters...Radio-communication networks, data transmition of high frequency signals,Surveillance systems and radar,Tactical and balistical missiles,Weapon systems.

APPLICATIONS

Hook-up wiresFlamex (halogen free)MIL W 16878/4-28MIL W 22759/5-31, 32-46MIL DTL 22759/80-92MIL DTL 27500NF C 93521 (KY / EPDX)

NF C 93523 (KZ)NF C 93524 (KU)AIR 4524 (1604, 604)AIR 4524 (1806, 806)AIR 4524 (2100)

Multipair and multiconductor cables

Standard multiconductors (SMA, SMBL, GRTH, CCTB, G250, G900), halogen free multiconductors, H05 / H07 RNFSpecial multiconductors : cables for shelter links in accordance with SEFT 027 (KQ) or other specifications.

Example: Et. 2PE904 - Composite cable according to special specification

1- 8 shielded and jacketed pairs (100 Ω) in tinned copper, FEP insulation, ETFE jacket2- 3- 4- 5- 6- 8- 9- Lay-up of composite KU (many different constructions and gauges)7- 75 Ω coax over shielded and over jacketed10- 11- Tapes12- Tinned copper shield13- Special jacket

6

7

8

9

10

11

12

13

1

2

3

4

5

Optical cables

Datatactic® optical: MTFC for air control systems program (A.C.C.S.), cables for shelter links.Jacketed optical fiber 250/400/900μm with reinforcement in aramid fibers (2, 4, 6 or 8 optical fibers)

Example: MTFC-xH08 : Datatactic® optical8 optical fibers Operating temperature : -40°C to +70°C

1- Optical fiber 250/400/900 μm 2- 3- Over jackets4- Reinforcement in aramid fibers5- Outer jacket in special PUR

123

4

5

Coaxial and multicoaxial cablesMIL C 17 (ex: RG)NF C 93550 (KX)Flamex KX/RG (halogen free)Low noise coaxial cables (CAS, KX, RG)

Hand formable coaxial cables (QuickForm®)High frequency coaxial cables (SFX 142, QuickFlex®)Triaxial cables (Et. 11820, Et. 17412, etc.)

d

6

7

8

9

10

11

12

13111

1

22

3

4

5

Page 7: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

7

Military market - Filotex®Military market - Filotex®

CABLES FOR GROUND FORCES

Special cablesCables with EMC hardened for battlefield communication system: Et. 298909, Et. 61333 and Et. 69342 (high temperature databus cable), etc.Databus cables from -105°C to +200°C for multiplex transmissions:- M17/176-00002- Et. 69794, Et. 69792, Et. 69654, Et. 61330

Example: M17/176-00002Operating temperature: -105°C to +200°C

1- Silver plated copper alloy conductor2- PTFE dielectric3- Lay-up of 2 elements4- Silver plated copper braid shield5- PFA jacket

p

1 2 3 4 5

Data cables

Datatactic® copper for shelter links in communication systems: 100, 300 or 600 MHz reinforced databus cables.

Example: 2PC856Operating temperature: -20°C to +70°C

1- Red copper conductor + polyolefine insulation + each pair individually shielded with a polyester/aluminium tape2- Tinned copper shield3- LSZH jacket4- Reinforcement : polyurethane5- Mechanical support6- Reinforcement : polyurethane

2

1

3

4

5

6

2

1

3

4

5

6

BraidsMetallic braids for overshielding: various types available (silver plated copper, tin plated copper, nickel plated copper braids)Nylon or superpolyamide braidsSingle and double braidsWith or without guarantee of transfert impedanceParticularly adapted to harsh and hostile conditions in harsh EMI environments.

Flat braid Tubular braid

Tubular braid Tubular superpolyamide with filler braid

Nexans is able to produce cables for radio links.

T b l b id

b l l

Page 8: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

Military market - Filotex®Military market - Filotex®

8

TYPE OF CABLE APPLICATION EXAMPLE

AIR

CR

AFT

WIR

ES &

CA

BLE

S

Hook-up wires Low voltage links

1604, 604, 1806, 806, 2100, 1000ABS, ASNE, EN, NSAMIL-W-16878, MIL-W-22759, MIL-DTL-81381Other specifications (Panavia, BS G222, etc.)

Cables for engines

Low voltage links HT

AIR 4527 (3000A, 3100)ASNE, ENBMS 13-55, BMS 13-58, BMS 13-67MIL-W-25038, MIL-DTL-27500Other specifications (ESW, RMS, TMF, etc.)

Coaxial cables Data transmission

MIL-C17 (ex RG)ASNE, NSAEN 4604PAN 6422ASNE 0406 WD (hyper-frequency)

Databus cables and high bit rate cables

Data transmission ABS, ASNE, PAN, EN

Special cables

Flight test ASNE (hook-up wires)

Measurments MBBN (thermocouples)

Data transmissionNSA, Vibrometer (low noise cables)Satcom (assemblies)

Optical cables Telecommunication systems ABS

Power supply Power supplyBMS 13-35ESW 1000ASNE, NSA, ABS

CA

BLE

S FO

R N

AV

Y

Hook-up wires Low voltage links

KY, EPDX, KU, etc.MIL-W-16878/4-28, MIL-W-22759/5-31, 32-46, MIL-DTL-22759/80-92, MIL-DTL-27500Flamex (halogen free)

Multipair and multiconductor

Data transmissionSMA, SMA-ZH, SMBL, SMBL-ZH, GRTH, etc.Shielded or unshielded halogen free multipairs

Low, medium and high vol-tage links

Halogen free multiconductors

Coaxial andmulticoaxial cables, armoured or non-armoured

Data transmissionKX, RGFlamex KX, RG (halogen free)CAS, KX, RG (low noise)

Mine detection Et. 268565, Et. 268414

Ethernet links Et. 382203, Et. 276659

Sonar cables Et. 124415

Vibration measurment Et. 287515

Data cables Telecommunication systems Datatactic® copper

Special cablesAntennas Et. 70344, Et. 77472

Torpedoes Et. 279458

Optical cablesMine detection Et. 385302

Data transmissionMultifibers for navy applicationsMulti-patchs

NEXANS CABLE RANGE AT A GLANCE

Page 9: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

9

Military market - Filotex®Military market - Filotex®

TYPE OF CABLE APPLICATION EXAMPLE

CA

BLE

S FO

R G

RO

UN

D F

OR

CES

Hook-up wires Low voltage links

KY, EPDX, KZ, KU, etc.1604, 604, 1806, 806, 2100MIL-W-16878/4-28, MIL-W-22759/5-31, 32-46, MIL-DTL-22759/80-92, MIL-DTL-27500Flamex (halogen free)

Multipair and multiconductor

Data transmissionSMA, SMA-ZH, SMBL, SMBL-ZH, GRTH, etc.KQ, composite cables

Medium and high voltage links

H05/H07 RNF

Coaxial and multicoaxial cables, armoured or non-armoured

Data transmission

KX, RGFlamex KX, RG (halogen free)CAS, KX, RG (low noise)QuickForm® (hand formable)SFX 142, QuickFlex® (hyper-frequency)Et. 11820, Et. 17412 (triaxials)

Data cables Shelter links Datatactic® copper

Special cablesSpecific EMC Et. 298909, Et. 61333, Et. 69342 (harden cables)

Multiplex transmissionsM17/176-00002, Et. 69794, Et. 69792, Et. 69654, Et. 61330 (databus cables)

Optical cables Shelter links Datatactic® optical (MTFC)

Braids ProtectionFlat, tubular braids (metallic)Superpolyamide braids (nylon)

NEXANS CABLE RANGE AT A GLANCE

SOME REFERENCES

Page 10: MMilitary market - Filotex®ilitary market - Filotex® · PDF fileBMS 13-55, BMS 13-58, BMS 13-67 (Boeing) ESW: Fireproof and filter cables ... Thermocouple extension : ... specification)

Military market - Filotex®Military market - Filotex®

10

Ed. 1 - February 2008 - Copyright© NexansThis newsletter shows a general description of products whose characteristics are not contractual.Nexans reseve the right to change specification without prior notice.

CONTACT :140 - 146 rue Eugène Delacroix - BP 191211 Draveil Cedex - FranceTel : +33 1 69 83 78 00 - Fax : +33 1 69 42 05 70www.nexans.com - [email protected]

A COMPREHENSIVE RANGE

ABOUT NEXANS

With energy as the basis of its development, Nexans, the worldwide leader in the cable industry, offers an extensive range of cables and cabling systems. The Group is a global player in the infrastructure, industry and building markets. Nexans addresses a series of market segments from energy, transport and telecom networks to shipbuilding, oil and gas, nuclear, automotive, electronics, aeronautics, handling and automation.

With an industrial presence in more than 30 countries and commercial activities worldwide, Nexans employs 22,000 people and had sales in 2007 of 7.4 billion euros. Nexans is listed on Euronext Paris, compartment A. More information on http://www.nexans.com/