MJP/MJN-SERIES - Instrumart · MJP/MJN-SERIES PLSE METER 253.872.0284 seametrics.com C e r t if i e...

4
MJP/MJN-SERIES PULSE METER 253.872.0284 seametrics.com C e r tifi e d C o m p a n y ISO 9001:2008 Features Certified to NSF/ANSI 61 Dry top multi-jet design Tolerates low quality water Simple pulse output APPLICATIONS Potable water Cooling tower chemical control Industrial water treatment Deduct metering Pump Pacing Contact your Supplier MJP-Series and MJN-Series meters use the multi-jet principle, which has been an internationally-accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in low- quality water. The Seametrics MJP-Series and MJN-Series are certified to NSF/ANSI 61. The impeller is centered in a ring of jets, with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the pointers is replaced by a magnet, which is detected by an encapsulated sensor attached to the outside of the lens. Pulse rate is determined by the dial on which the magnet is placed, and by the number of sensors (single or double). Changing the pulse rate requires no special tools and can be done in the field. The MJP-Series has a plastic body and is available in 3/4”, 1”, and 1 1/2” versions. The MJN-Series has a brass body and is available in 3/4”, 1”, 1 1/2” and 2” versions. MJPE & MJNE meters use a solid-state, long-lasting Hall-effect sensor, which requires power. It is suited for use with Seametrics controls and metering pumps that have sensor power. MJPR & MJNR meters use a two-wire reed switch. They provide a dry contact closure and do not require power. MJPT& MJNT meters totalize only and do not have a sensor. MJN-Series MJP-Series

Transcript of MJP/MJN-SERIES - Instrumart · MJP/MJN-SERIES PLSE METER 253.872.0284 seametrics.com C e r t if i e...

MJP/MJN-SERIESPULSE METER

253.872.0284 seametrics.com

Ce

rtified Company

ISO9001:2008

9 0 0 1 : 2 0 0 8CERTIFIED COMPANYISO

Features• Certified to NSF/ANSI 61

• Dry top multi-jet design

• Tolerates low quality water

• Simple pulse output

APPLICATIONSPotable water

Cooling tower chemical control

Industrial water treatment

Deduct metering

Pump Pacing

Contact your Supplier

MJP-Series and MJN-Series meters use the multi-jet principle, which has been an internationally-accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in low-quality water. The Seametrics MJP-Series and MJN-Series are certified to NSF/ANSI 61. The impeller is centered in a ring of jets, with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the pointers is replaced by a magnet, which is detected by an encapsulated sensor attached to the outside of the lens. Pulse rate is determined by the dial on which the magnet is placed, and by the number of sensors (single or double).

Changing the pulse rate requires no special tools and can be done in the field.

The MJP-Series has a plastic body and is available in 3/4”, 1”, and 1 1/2” versions.

The MJN-Series has a brass body and is available in 3/4”, 1”, 1 1/2” and 2” versions.

MJPE & MJNE meters use a solid-state, long-lasting Hall-effect sensor, which requires power. It is suited for use with Seametrics controls and metering pumps that have sensor power.

MJPR & MJNR meters use a two-wire reed switch. They provide a dry contact closure and do not require power.

MJPT& MJNT meters totalize only and do not have a sensor.

MJN-SeriesMJP-Series

253.872.0284 Page 2 seametrics.com

MJP/MJN-SERIESPULSE METER

Features

Specifications*Power 6 mA at 12 Vdc (MJPE & MJNE only)

Temperature 105˚ F (40˚ C) max

Pressure 150 psi operating (10.3 Bar)

Materials Body Plastic (MJP) or Eco-brass alloy (MJN)

Internals Engineered thermoplastic

Magnet Alnico

Fittings Lead-free tail piece

Accuracy ±1.5% of reading

Pulse Output MJPE/MJNE MJPR/MJNR MJPT/MJNT

Sensor Hall-effect device Reed switch Totalizer only

Max Current 20 mA 20 mA n/a

Max Voltage 24 Vdc 24 Vdc or Vac n/a

Cable Length 12’ (4 m) standard (2000’ maximum run)

Flow Rates (GPM)** 3/4” 1” 1 1/2” 2” (MJN only)

Minimum 0.25 0.75 1.5 2.0

Maximum 20 50 100 160

Regulatory NSF/ANSI 61, complies with Federal Public Law 111-380

Standards ISO4064 Class B, AWWA C708

*Specifications subject to change • Please consult our website for current data (www.seametrics.com).** Caution: Excessive flow can cause breakage. Do not exceed recommended maximums.

MJN-Series(brass body)

Union end couplings for easy service

Plastic body (MJP) or Brass body (MJN)

The MJPE/MJNE or MJPR/MJNR sensor fastens to lens without removing top

Calibration plug seal wire for tamper evidence

MJP-Series(plastic body)

253.872.0284 Page 3 seametrics.com

MJP/MJN-SERIESPULSE METER

Dimensions

Pressure Drop Curve

Pulse Rates

20

15

10

5

0

2.5 5 7.5 10 15 20 25

5 10 15 20 25 30 35 40 45 50

10 20 30 40 50 60 70 80 90 100

3/4"

1"

1-1/2"

13 26 39 52 65 78 91 104 117 1302"

12.5 17.5 22.5

(MJN only)

Rate of flow in gallons per minute (GPM)

Pres

sure

dro

p in

P.S

.I.

C

AB

D

*MJPR/MJNR dual reed switch meters only†MJPR/MJNR single reed switch meters only

3/4” 1” 1 1/2” 2”(MJN only)

Pulses per Gallon

20*104†2*1

4†2*1

4†2*1

4†2*1

Gallons per Pulse

15*1050*100

15*1050*100

15*1050*100

15*1050*100

Cubic Feet per Pulse

15*10

15*10

15*10

15*10

Pulses per Cubic Meter

110100

110100

110100

110100

Liters per Pulse

110100

110100

110100

110100

MJP 3/4” 1” 1 1/2”

A (body) 7 1/2” 10 1/4” 11 3/4”B (w/couplings) 11 5/8” 15” 17”C (IPS thread) 1” 1 1/4” 2”D (NPT thread) 3/4” 1” 1 1/2”

MJN 3/4” 1” 1 1/2” 2”

A (body) 7 1/2” 10 1/4” 11 3/4” 11 3/4”B (w/couplings) 11 5/8” 15” 17” 17 5/8”C (IPS thread) 1” 1 1/4” 2” 2 1/2”D (NPT thread) 3/4” 1” 1 1/2” 2” MJP MJN

lb kg lb kg3/4” 3 1.4 6 2.71” 4.5 2 8 3.61 1/2” 7.5 3.4 13 5.92” n/a n/a 16 7.3

Shipping Weight

LT-14382r2.0 20161012 10/12/16

Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA (P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com

MJP/MJN-SERIESPULSE METER

Model Size Pulse Rate OptionsPLASTIC

MJPR = Reed Switch

MJPE = Hall-effect sensor

MJPT = Totalizer only

BRASS

MJNR = Reed Switch

MJNE = Hall-effect sensor

MJNT = Totalizer only

-075 = 3/4”

-100 = 1”

-150 = 1 1/2”

-200 = 2” (MJN only)

MJPR/MJNR

(Single Reed)

MJPR/MJNR

(Dual Reed)

MJPE/MJNE

MJPT/ MJNT

-06 = LMI pump connector

-07 = Seametrics control connector

20P = 20 Pulse/Gal √*

10P = 10 Pulse/Gal √* √*

4P = 4 Pulse/Gal √

2P = 2 Pulse/Gal √

1G = 1 Gal/Pulse √ √

5G = 5 Gal/Pulse √

10G = 10 Gal/Pulse √ √

50G = 50 Gal/Pulse √

100G = 100 Gal/Pulse √ √

1CF = 1 CF/Pulse √ √

5CF = 5 CF/Pulse √

10CF = 10 CF/Pulse √ √

1CM = 1 Pulse/CM √ √

10CM = 10 Pulse/CM √ √

100CM = 100 Pulse/CM √ √

1L = 1 Liter/Pulse √ √

10L = 10 Liter/Pulse √ √

100L = 100 Liter/Pulse √ √

G = Gallons √

CF = Cubic Feet √

CM = Cubic Meters √

L = Liters √

*3/4” only

AccessoriesPD10 = Pulse dividerPS40 = Pulse splitterPT35 = Pulse timer

103239-075 = 3/4” Brass coupling assembly w/gasket (incl 2 sets) 103239-100 = 1” Brass coupling assembly w/gasket (incl 2 sets) 103239-150 = 1.5” Brass coupling assembly w/gasket (incl 2 sets) 103239-200 = 2” Brass coupling assembly w/gasket (incl 2 sets) 103924-075 = 3/4” Plastic coupling assembly w/gasket (incl 2 sets) 103924-100 = 1” Plastic coupling assembly w/gasket (incl 2 sets)103924-150 = 1.5” Plastic coupling assembly w/gasket (incl 2 sets)

How to Order