www.pvlighthouse.com.au Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems IEEE PVSC 20-Jun-2019 Keith McIntosh , Malcolm Abbott & Ben Sudbury, PV Lighthouse Jenya Meydbray, PV Evolution Labs

Transcript of Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1...

Page 1: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 1

Mismatch loss in bifacial modulesdue to non-uniform illumination in

1D tracking systems

IEEE PVSC20-Jun-2019

Keith McIntosh, Malcolm Abbott & Ben Sudbury, PV Lighthouse

Jenya Meydbray, PV Evolution Labs

Page 2: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 2

Image from https://www.nextracker.com

Page 3: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 3

Equivalent circuit of a PV module

Page 4: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 4

Equivalent circuit of a PV module

Page 5: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 5

Equivalent circuit of a PV module

Page 6: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 6

Equivalent circuit of a PV module

Page 7: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 7

Equivalent circuit of a PV module

SPICE solver gives module’s IV curve

Page 8: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 8

0.1% -0.7% 0.4% 0.0% 0.0% -0.1%

0.0% -0.9% -0.4% -0.1% 0.0% -0.2%

-0.2% 0.3% 0.1% 0.3% 0.0% 0.6%

0.2% -0.1% -0.4% -0.1% 0.0% -0.2%

-0.1% 0.0% 0.4% -0.2% 0.2% -0.2%

-0.2% 0.7% -0.3% 0.1% -0.5% 0.1%

-0.1% 0.8% 0.4% 0.3% -0.1% 0.1%

-0.3% -0.5% 0.1% 0.0% 0.3% -0.1%

0.2% 0.1% -0.3% 0.1% -0.1% 0.2%

0.2% 0.7% -0.5% -0.3% -0.5% 0.4%

0.1% -0.1% 0.1% 0.2% -0.8% 0.1%

0.3% 0.0% 0.1% 0.0% -0.4% -0.5%

Equivalent circuit of a PV module

Highly uniform

No cell-to-cell mismatch loss

Page 9: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 9

4.8% -2.4% 0.5% 1.7% 0.2% 0.1%

-1.3% -1.0% -1.0% -3.3% 2.6% 1.8%

0.7% 3.9% 1.2% 0.3% -4.2% -0.8%

-2.6% 2.8% 0.9% -1.2% 5.2% -4.4%

-2.4% -1.1% 3.6% -5.0% 3.5% -9.4%

1.7% -0.7% 3.1% 2.6% -5.0% 1.6%

-3.1% -0.2% 0.6% -1.5% -0.6% 1.2%

-0.9% -3.0% -4.1% -3.6% 2.7% 4.7%

2.1% 6.1% -1.3% -4.8% 1.9% 2.0%

3.8% 5.4% -4.8% 0.7% 1.0% -1.4%

-2.3% -2.4% -1.4% -0.5% 3.7% -4.2%

1.9% 3.0% -3.8% 2.4% -1.0% 2.4%

Equivalent circuit of a PV module

Non-uniform

Significant cell-to-cell mismatch loss

Page 10: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 10

23.3% -31.2% 17.2% 28.0% 25.1% -36.9%

8.5% 11.1% 55.3% 14.2% 2.2% 22.3%

-6.0% 35.9% -28.4% 37.7% -25.7% -24.3%

-42.7% 55.7% -23.9% -1.4% -8.3% 45.9%

-30.3% 62.8% 33.8% -58.4% -5.4% -41.9%

-28.2% 2.9% -18.4% -29.4% -27.1% 58.3%

62.7% 21.2% -9.1% 29.0% 13.9% 70.6%

-26.0% 30.0% -40.3% -50.1% -34.9% 19.1%

-36.3% 26.7% -8.5% 5.6% -24.2% 3.7%

-27.4% -66.0% -39.4% 42.6% -7.4% -27.9%

-27.4% 44.6% -22.8% 12.5% 10.2% 6.3%

-5.3% -28.9% 4.4% 33.0% -12.8% -44.1%

Equivalent circuit of a PV module

Awfully non-uniform

Awful cell-to-cell mismatch loss

Page 11: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 11

Equivalent circuit of a PV module

Page 12: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 12

Mismatch loss due to insufficient rays

0

50

100

150

200

250

300

350

400

1E+3 1E+4 1E+5 1E+6 1E+7

Mo

du

le p

ow

er (W

)

Number of rays traced

0.01

0.1

1

10

100

1E+3 1E+4 1E+5 1E+6 1E+7

Un

de

rest

imat

ion

in p

ow

er

(%)

Number of rays traced

Page 13: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 13

• Inputs are material properties and geometries.

• Optics solved by ray tracing:– cloud-based (≤ 2000 parallel cores)

– optimized physics solver

– extremely fast.

• Widely used by– tier 1 module manufacturers

– materials companies

– leading research institutes.

• Expanded for PV systems– Ground, torque-tube, system configuration, backtracking

– SPICE to solve module circuit

– Temperature model

– Backtracking

SunSolve™

Page 14: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 14

System

No standard

q = 0 – 90˚

Variable spectrum

G = 0 – 1100 W/m2 ?

T = –10 – 75 ˚C ?

weeks – year

$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$

Solar cell

STC

q = 0˚

AM1.5g

G = 1000 W/m2

T = 25 ˚C

seconds

$

Measurement conditionsModule

STC

q = 0˚

AM1.5g

G = 1000 W/m2

T = 25 ˚C

seconds

$$$$$$$$$$$$$$$$$$$$

Page 15: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 15

Example: Isotexture vs black silicon vs pyramids

Paper 855: Friday 9:30 AM, Area 4Malcolm Abbott et al.“Annual energy yield analysis of solar cell technology”

SunSolve™

Page 16: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 16

Systems investigated

• Bifacial.

• 1D tracking, NS axis

• One-high & two-high

Image from https://www.nextracker.com Image from https://www.pv-magazine.com

Page 17: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 17

Complications of rear illumination

• Direct and diffuse light on rear is different to the front.

• Direct light reflected more onto bottom of the module,depends on the time of day.

• Torque-tube shading.

Page 18: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 18

More complications of rear illumination

• Solar spectrum changes throughout day & year.

• Solar spectrum differs for direct and diffuse light.

• Reflectance of ground and torque-tube depend on wavelength.

Data from NASA databases: https://speclib.jpl.nasa.gov/.

Page 19: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 19

• Solar spectrum changes throughout day & year.

• Solar spectrum differs for direct and diffuse light.

• Reflectance of ground and torque-tube depend on wavelength.

• Module’s response depends on wavelength and incident angle.

• Module’s rear response differs to front response.

As simulated by PV Lighthouse

for contemporary bifacial module

under normal incidence.

More complications of rear illumination

Page 20: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 20

Mismatch within a module4

3

2

1

South

θsun = 90˚ φsun = 91˚

θinc = 90˚ θmod = 0˚

Page 21: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 21

Mismatch within a module4

3

2

1

South

θsun = 84.3˚ φsun = 102˚

θinc = 60.4˚θmod = 24.5˚

Page 22: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 22

Mismatch within a module4

3

2

1

South

θsun = 73.3˚ φsun = 112˚

θinc = 24.3˚θmod = 60.0˚

Page 23: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 23

Mismatch within a module4

3

2

1

South

θsun = 63.2˚ φsun = 124˚

θinc = 30.0˚θmod = 58.6˚

Page 24: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 24

Mismatch within a module4

3

2

1

South

θsun = 54.5˚ φsun = 138˚

θinc = 37.4˚θmod = 43.0˚

Page 25: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 25

Mismatch within a module4

3

2

1

South

θsun = 48.2˚ φsun = 156˚

θinc = 42.7˚θmod = 24.7˚

Page 26: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 26

Mismatch within a module4

3

2

1

South

θsun = 45.3˚ φsun = 176˚

θinc = 45.1˚θmod = 4.2˚

Page 27: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 27

Mismatch within a module4

3

2

1

South

θsun = 46.5˚ φsun = 197˚

θinc = 44.1˚θmod = 16.8˚

Page 28: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 28

Mismatch within a module4

3

2

1

South

θsun = 51.6˚ φsun = 215˚

θinc = 39.8˚θmod = 36.1˚

Page 29: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 29

Mismatch within a module4

3

2

1

South

θsun = 59.4˚ φsun = 231˚

θinc = 33.0˚θmod = 52.7˚

Page 30: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 30

Mismatch within a module4

3

2

1

South

θsun = 69.1˚ φsun = 243˚

θinc = 25.6˚θmod = 60.0˚

Page 31: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 31

Mismatch within a module4

3

2

1

South

θsun = 79.8˚ φsun = 254˚

θinc = 28.5˚θmod = 55.2˚

Page 32: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 32

Mismatch within a module4

3

2

1

South

θsun = 90˚ φsun = 268˚

θinc = 90˚θmod = 0˚

Page 33: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 33

12-months at NREL, Colorado

Data from NREL databases

• Ambient temperature.

• Wind velocity.

• Cloud fraction.

• Incident global intensity.

1-Sep-2017 31-Aug-2018

Page 34: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 34

12-months at NREL, Colorado

Data from NREL databases for 14-Mar-2018.

• Integrated direct intensity

• Integrated diffuse intensity

• Global spectra

• Direct spectra

→ Diffuse spectra

Page 35: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 35

Modern 72-cell bifacial module

Page 36: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 36

• 20 million rays per incident angle.

• 4400 solutions per year (hourly in daylight hours).

• ~45 mins to solve the annual yield per system configuration(ray tracing + temperature solving + SPICE solving).

• Ways to reduce solutions to <5 mins have been identified.

Solve annual yield

Page 37: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 37

Example: 1-high central module, sunny day

Page 38: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 38

Example: 1-high central module, cloudy day

Page 39: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 39

(a) 8 AM (b) 10 AM (c) 12 PM (d) 2 PM (e) 4 PM

0.3% 0.1% 0.3% 0.1% 0.5% 0.1% 2.9% 2.9% 2.5% 3.1% 2.6% 3.3% 2.4% 1.8% 1.6% 2.2% 2.4% 2.4% 0.5% 0.5% 0.6% 0.3% 1.0% 0.2% 0.1% -0.1% -0.1% -0.2% -0.5% 0.0%

-0.1% 0.1% -0.2% 0.4% 0.3% 0.4% 2.3% 2.4% 1.9% 2.4% 1.7% 2.4% 1.5% 2.0% 1.4% 1.3% 1.8% 1.8% 0.8% 1.0% 0.5% 0.6% 0.4% 0.3% 0.0% 0.1% -0.4% 0.1% -0.1% 0.3%

0.2% -0.5% 0.3% -0.1% 0.3% -0.1% 1.3% 1.5% 1.7% 1.9% 1.7% 1.4% 1.6% 1.3% 1.4% 1.4% 1.0% 1.6% 0.4% 0.2% 0.5% -0.1% 0.9% 0.4% -0.4% 0.3% -0.2% -0.6% 0.2% 0.1%

-0.3% -0.2% 0.2% -0.1% 0.2% 0.0% 0.6% 0.8% 0.7% 1.6% 0.9% 0.7% 0.8% 0.5% 0.8% 0.7% 0.8% 0.8% 0.2% 0.1% 0.3% 0.8% 0.1% 0.3% 0.1% 0.1% 0.1% -0.1% 0.1% -0.2%

0.3% 0.3% -0.2% 0.0% 0.2% -0.1% -0.1% 0.5% 0.0% 0.4% 0.3% -0.2% 0.4% 0.5% 0.2% 0.8% 0.5% 0.5% 0.5% 0.1% 0.1% 0.4% 0.2% 0.6% -0.2% 0.0% 0.2% 0.4% 0.4% 0.0%

0.2% 0.2% -0.1% 0.2% 0.2% 0.0% -0.2% -0.5% -0.1% 0.0% 0.0% -0.4% 0.2% 0.5% 0.1% 0.5% -0.1% -0.4% -0.1% 0.4% 0.5% 0.1% -0.2% 0.5% 0.0% -0.3% 0.0% -0.1% 0.2% 0.2%

0.1% 0.0% -0.3% -0.3% 0.0% -0.1% -0.6% -0.7% -0.6% -0.5% -0.8% -0.5% -1.0% 0.2% -0.1% 0.0% -0.1% -0.2% 0.0% 0.3% 0.1% 0.2% 0.7% 0.2% 0.5% 0.3% 0.3% -0.2% 0.2% 0.4%

0.1% -0.3% -0.4% 0.2% 0.0% -0.1% -1.1% -0.9% -1.0% -0.6% -1.2% -1.3% -0.3% -0.3% -0.3% -1.0% -0.6% -0.5% -0.5% 0.0% 0.0% 0.3% -0.2% -0.2% 0.1% 0.3% -0.1% 0.5% -0.1% -0.1%

-0.4% 0.4% -0.1% -0.1% -0.1% -0.4% -1.5% -1.6% -1.1% -1.4% -1.0% -1.3% -0.6% -0.8% -0.6% 0.1% -0.4% -1.2% 0.3% 0.0% -0.6% 0.4% 0.0% 0.1% 0.2% -0.1% 0.0% 0.3% 0.0% 0.2%

0.2% -0.2% 0.2% 0.0% 0.1% -0.1% -1.4% -1.4% -1.0% -1.3% -1.5% -1.8% -1.3% -1.1% -0.8% -0.5% -0.9% -0.7% 0.0% -0.4% 0.1% -0.4% -0.1% -0.4% 0.0% 0.1% -0.2% 0.1% -0.1% -0.2%

-0.1% -0.3% 0.2% -0.2% -0.1% -0.2% -1.6% -1.3% -1.8% -1.1% -1.4% -1.7% -1.5% -1.4% -1.2% -2.1% -1.6% -1.6% -1.0% -1.2% -0.7% -0.6% -0.4% -1.3% -0.5% 0.4% 0.2% 0.0% 0.1% -0.2%

-0.2% -0.3% -0.3% -0.4% -0.4% 0.7% -1.3% -1.7% -2.0% -1.8% -1.8% -1.6% -2.8% -3.1% -2.8% -3.0% -2.7% -2.5% -1.4% -1.4% -1.3% -1.7% -1.1% -1.2% -0.5% -0.3% -0.5% -0.2% 0.2% -0.6%

0.5% 0.3% 0.6% 0.1% 0.5% 0.4% -1.4% -0.9% -0.7% -0.7% -1.0% -0.7% -2.7% -3.2% -3.4% -3.0% -2.4% -2.6% -1.7% -1.9% -2.0% -1.8% -2.1% -1.6% -0.1% -0.1% 0.0% 0.0% -0.2% 0.5%

-0.3% 0.0% 0.0% -0.1% 0.2% 0.0% -0.4% -0.2% -0.3% -0.6% -0.4% -0.4% -1.2% -1.8% -1.3% -0.9% -1.9% -1.5% -1.9% -1.2% -1.4% -1.4% -1.2% -1.5% -0.3% -0.5% -0.4% -0.2% -0.3% -0.4%

-0.2% 0.0% -0.5% 0.0% 0.1% -0.1% 0.4% 0.0% 0.1% 0.5% -0.2% 0.2% -0.7% -1.1% -1.0% -1.0% -1.0% -1.4% -1.0% -1.1% -1.4% -1.9% -1.3% -1.7% -0.2% 0.0% 0.1% 0.0% -0.4% 0.0%

-0.1% -0.2% -0.5% -0.2% 0.1% 0.4% -0.2% -0.3% -0.1% -0.1% 0.2% -0.2% -0.7% -1.0% -0.5% -0.9% -0.6% -0.4% -1.0% -1.0% -1.2% -1.7% -1.7% -1.5% 0.0% -0.4% -0.1% 0.1% -0.4% 0.3%

0.1% 0.3% 0.0% 0.4% 0.1% -0.4% -0.3% 0.0% -0.1% 0.2% 0.2% 0.3% -0.3% 0.4% -0.3% -0.3% -0.5% -0.5% -0.9% -1.3% -1.1% -0.4% -0.5% -1.2% 0.1% -0.1% -0.5% -0.2% -0.2% -0.2%

-0.1% 0.0% 0.1% 0.0% 0.0% 0.1% -0.4% 0.0% -0.2% 0.0% 0.3% 0.4% 0.0% 0.4% 0.0% 0.0% 0.0% -0.6% -1.1% -0.3% -0.2% -0.3% -1.0% -0.4% 0.4% 0.0% 0.1% 0.0% -0.3% -0.1%

0.0% 0.1% 0.2% -0.2% 0.1% -0.4% 0.0% 0.1% 0.2% 0.0% 0.4% 0.5% -0.2% 0.0% 0.5% 0.4% -0.2% 0.0% -0.4% 0.0% -0.6% -0.2% -0.5% 0.3% -0.4% 0.1% 0.0% -0.3% 0.4% -0.1%

-0.1% 0.1% -0.2% 0.0% 0.2% -0.2% -0.1% 0.2% 0.2% 0.6% 0.1% 0.3% 0.8% 0.0% 0.5% 0.9% 0.4% 0.6% 0.5% 0.1% 0.4% 0.4% 0.2% -0.1% 0.4% 0.3% 0.2% -0.4% 0.1% -0.2%

-0.2% -0.4% 0.2% -0.2% 0.1% 0.1% -0.2% 0.8% -0.1% 0.1% 0.6% 0.3% 0.8% 0.7% 0.8% 0.3% 0.3% 0.7% 0.9% 1.3% 0.8% 0.5% 0.9% 1.1% 0.1% 0.0% 0.6% -0.1% 0.6% 0.2%

0.0% 0.0% -0.1% 0.5% 0.0% 0.5% 0.1% 0.7% 0.4% -0.1% 0.6% 0.2% 1.2% 1.0% 0.9% 1.4% 0.9% 1.4% 1.1% 1.1% 1.6% 1.5% 1.4% 1.5% -0.1% 0.4% 0.2% -0.1% 0.2% 0.2%

0.0% -0.1% -0.4% 0.1% -0.3% -0.3% 0.3% -0.1% 0.1% 0.0% 0.0% 0.1% 1.7% 1.5% 1.2% 2.2% 1.8% 1.8% 2.5% 2.1% 2.0% 2.2% 2.8% 2.2% -0.1% 0.1% 0.4% 0.6% 0.1% 0.2%

-0.3% -0.2% 0.2% -0.2% 0.2% 0.1% 0.2% -0.1% -0.3% 0.3% 0.2% 0.5% 2.3% 2.1% 2.7% 2.3% 1.8% 2.5% 3.4% 2.6% 3.2% 2.6% 2.8% 2.7% 0.0% 0.2% 0.7% -0.2% 0.0% 0.1%

Example: 2-high central module, sunny day

Page 40: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 40

• For baseline cases– 0.23% for one-high system;

– 0.1% for two-high system.

• Greater loss on diffuse days.

Mismatch loss – central module(due to non-uniform illumination in module)

Page 41: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 41

Evaluate different system configurations

Page 42: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 42

Evaluate different system configurations

Page 43: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 43

Edge modulesOne-high Two-high

Page 44: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 44

One-high

Page 45: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 45

Two-high

Page 46: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 46

• Annual yield solved by ray tracing to micron-level, accounting for– Spectral variability of direct and diffuse light,

– Spectral and angular dependencies of ground, torque-tube and module,

– Mismatch within a module due to non-uniform illumination.

• Results allow us to quantify advantages– system configurations,

– module features,

– simulation assumptions.

• Mismatch loss due to non-uniformity in 1-high configs is about:– 0.23% for our baseline conditions,

– 2–3 times greater than two-high configs,

– 50% greater for edge modules,

– Depends strongly on albedo.

Summary

Page 47: Mismatch loss in bifacial modules due to non-uniform ... … · Premium PV software Slide 1 Mismatch loss in bifacial modules due to non-uniform illumination in 1D tracking systems

www.pvlighthouse.com.auPremium PV software Slide 47

www.pvlighthouse.com.au

WeChat: B7282628

Thank you