MIR-9000-CLDMulti-Gas Infrared GFC Analyser The MIR-9000-CLD option utilises Standard Reference Method (SRM) for the monitoring of NO, N2O, NO2, NOx, CO, CO2, SO2 and O2.
3 Monitoring Technologies for High Accuracy at Low LevelsThe MIR-9000-CLD analyser is a free standing monitoring system that incorporates three monitoring technologies; Chemiluminescence for low level NOx , Infra-Red Gas Filter Correlation for CO, CO2 etc and Paramagnetic for O2.
Assists In Achieving IED Compliance Designed to operate under the Industrial emissions directive, the MIR-9000 CLD offers maximum availability and complete compliance
Leading Edge Technology The MIR-9000-CLD would be rack mounted in air conditioned enclosures. Complete systems would normally comprise of; • Sample extraction and conditioning probe (with integrated temperature, pressure and flow measurement)• Heated sample lines• Cold sample lines• Automatic calibration units• Instrument air drying system• a1-cbiss Data acquisition & management system (CDAS)
KEYBENEFITS• Chemiluminescence Standard
Reference Method for low & ultra low
NOx
• Measures dry & corrosive samples
• Fast & simultaneous measurements of
up to 10 gases (SO2 / N2O can be added
to IR GFC module)
• Automatic cross interference correction
• Intrinsic security with on-board residual
H2O measurement
• Dry-basis measurement technique
• MCERT & TÜV compliant
The CLD Option makes the MIR 9000 the ideal tool for monitoring
low concentration levels of NOx “ “
CERTIFIEDRANGES
CH4
NO2 NO
SO2
CO
HCl
NOx CO2
O2N2O
11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HTT: +44(0)151 666 8300 F: +44(0)151 666 8329 E: [email protected] W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com
Cert No. 996ISO 9001
TECHNICALSPECIFICATION
GENERAL • Utilises Fourier Transform Infra-Red technology
• IED compliant
• Fast and simultaneous measurements for multiple gases
• Multi-component measurement capabilities
APPLICATIONS• Municipal and Hazardous Waste Incinerators
• Cogeneration, Gas Turbines
• Industrial Boilers and Furnaces
• Power & Combustion
PHYSICAL • Dimensions: Version with CLD (tight box):
• 200x600x600 mm (DxWxH)
• Weight: 32 Kg
PERFORMANCE • Operating temperature: +5 °C to +40 °C
• Power supply: 80 - 230V, 50-60 Hz
• Consumption: 300 VA
• Serial link: RS232, RS 422
CERTIFIED RANGES • NO (CLD): 0-20 / 2 000
• NOx (CLD): 0-20 / 2 000
• NO2 (CLD): 0-20 / 200
• NO (IR): 0-80 / 500
• NOx (IR): 0-200 / 5000
• NO2 (IR): 0-200
• CO: 0-75 / 10000
• CO2: 0-10 / 25 %
• SO2: 0-75 / 5000
• N2O: 0-20 / 1000
• HCl: 0-15 / 5000
• CH4: 0-10 / 1000
SPAN & DRIFT• Repeatability: <2% of Full Scale (F.S.)
• Zero drift: <2% F.S. / 30 days
• Span drift: < 1% F.S. / 7 days
• Linearity: < 1% F.S.
COMPLIANCE • MCERTs certified to EN15267-3
• QAL1 as defined by EN14181
• QAL3 compliance to EN14181
Complete Project Solutions
• Expert consultancy • Project management • In-house project design & build • Installation & commissioning
• After product service & support