minutes with no tools required. Diving Equipment and ...
Transcript of minutes with no tools required. Diving Equipment and ...
Dräger LAR 5002Diving Equipment and Systems
The Dräger LAR 5002 is a non-magnetic closed-circuit diving apparatusfor special operations diving. It is designed for use with pure oxygenand depths up to 10 metres. The device function has been streamlinedfor especially easy handling and can be prepared for diving in just a fewminutes with no tools required.
D-7
325-2
016
Adjustable lung demand valve
for tactical ascent support
Oxygen cylinder
Pressure gauge (in housing)
Manual bypass
Robust housing
Benefits
02 | Dräger LAR 5002
Non-magnetic
The Dräger LAR 5002 is a non-magnetic diving apparatus conforming to STANAG 2897, class A. All devicecomponents are designed and dimensioned according to the standard.
Adjustable lung demand valve
The adjustable lung demand valve supports tactical ascent. The time at which the lung demand valve opens caneasily be changed in order to optimise the use of the available oxygen during ascent. This ensures a bubble-free ascent.
Easy and quick assembly
The LAR 5002 is quickly assembled and ready to use in just a few simple steps – no tools necessary. It can beassembled even in poor lighting conditions or confined spaces.
Robust housing
All components of the diving apparatus are protected by a robust housing. Thanks to this housing, the LAR5002 can be used in extreme environments or challenging conditions. You can trust that the components areprotected even when the apparatus is thrown off or dropped.
Simple cylinder adaptation
The cylinder straps of the Dräger LAR 5002 can easily fit cylinders of different diameters without usingextension equipment. Cylinders of different materials and different volumes are available.
Reliability
Thanks to the robust design and extremely high reliability of the diving apparatus, it is widely used. Specialoperations around the world rely on the high quality of the LAR product range.
Accessories
Dräger LAR 5002 | 03
D-7
7428
-201
3
Dräger DiveSorb® Pro
The Dräger DiveSorb® Pro was developed specifically for closedor semi-closed rebreathers in order to allow a high degree of CO2
absorption, and thus long dive times.
ST-2
671-
2004
Dräger Panorama Nova Dive
The Panorama Nova Dive is based on a tried and tested mask body.Together with the 5-point harness it provides an excellent, tight fit.
D-1
1306
-201
6
Oxygen and mixed gas cylinders
Both non-magnetic and magnetic oxygen cylinders are available.
D-1
1943
-201
6
Transport case for the Dräger LAR 5002
The robust transport case can be used to safely store and transport theDräger LAR 5002 and its accessories. The cases can be stacked.
Services
04 | Dräger LAR 5002
D-2
331-
2016
Product Service
Our product service department supports you with a range of servicepackages – in our shops or on site in your plant. Care, servicingand maintenance are key factors when it comes to safety. Diligentmaintenance and care is also absolutely necessary from an economicsperspective. Preventive checks, service procedures and originalreplacement parts make your investment last longer.
D-2
335-
2016
Training
The Dräger Academy has imparted well-founded and practicalknowledge for over 40 years. With over 110 authorized trainers andmore than 600 available topics, we conduct more than 2,400 trainingsessions per year. We equip your employees with the knowledgerequired for real-life situations and ensure that the learned material canbe recalled and applied reliably – in their everyday work and especiallyin stressful situations. To meet your needs, we are also happy todevelop a customized training program specifically for you.
Related Products
ST-1
5412
-200
8
Dräger LAR 5000
LAR 5000 is a very streamlined and compact diving apparatus forspecial operations diving. Optionally the apparatus can be suppliedfrom a nitrox regulator for submarine lock-out. With its fold-in pressuregauge, LAR 5000 embodies a streamlined rebreather for military use.
Related Products
Dräger LAR 5002 | 05
D-7
7432
-201
3
Dräger LAR 5010
LAR 5010 is a closed-circuit diving apparatus for special operationsdiving. Optionally, the apparatus can be supplied with Nitrox B to enablediving depths of 24 m. LAR 5010 offers the additional option to be back-carried.
ST-4
01-2
008
Dräger LAR 7000
Dräger LAR 7000 is a very versatile diving apparatus for all facets ofshallow water diving, including VSW – MCM diving and submarine lock-out as well as special operations diving.
ST-1
5413
-200
8
Dräger LAR VII Combi FA
Dräger LAR VII Combi FA is a very versatile and compact divingapparatus for all facets of shallow water diving, including VSW – MCMdiving and submarine lock-out as well as special operations diving.
Technical Data
06 | Dräger LAR 5002
Dräger LAR 5002 basic unitDescription Closed-circuit with lung demand valveDiving depth 0 to 10 metresDiving duration 240 min With RMV 22.5 L/min / 4°CBreathing gas Pure oxygenBreathing bag Flexible volume approx. 5.5 L / available
volume approx. 10 LSoda lime Dräger DiveSorb® Pro; approx. 2.3 kg per
fillingMagnetic signature STANAG 2897, class ADimensions Length 425 mm, width 300 mm,
depth 170 mmWeight In air Approx. 13 kg
In water Neutral
Operating temperature -2°C to 40°CStorage temperature -40°C to 50°C
Cylinder dataOxygen cylinder Non-magnetic (NM)
(STANAG 2897)Low magnetic (LM) Magnetic
Volume 2.0 L 1.9 L 1.5 LDiameter 140 mm 134 mm 115 mmNominal pressure 200 bar 200 bar 200 barConnection G 3/4" G 3/4" G 3/4"Material Composite Aluminium SteelApprovals TÜV DOT3AL TÜVPositioning Under the diving apparatus Under the diving apparatus Under the diving apparatus
Ordering Information
Dräger LAR 5002 T 15 002
CylindersOxygen cylinder – NM, 2 L, with valve, black, STANAG A T 16 991Oxygen cylinder – LM, 1.9 L, with valve, black T 17 353Oxygen cylinder – magnetic, 1.5 L, with valve, black, steel B 03 961
AccessoriesTransport case, plastic, large, with foam inlays T 16 956Tactical harness 1000 – basic version, size S T 92 169Tactical harness 1000 – basic version, size M T 92 161Tactical harness 1000 – basic version, size L T 92 165Tactical harness 1000 – basic version, size XL T 92 166Diving mask, black, magnetic T 53 307Diving mask, black, non-magnetic T 16 471
ToolsTool bag T 14 410Tool bag, non-magnetic T 16 405
Ordering Information
Dräger LAR 5002 | 07
Spare partsSpare parts set T 14 411
Consumables
Dräger DiveSorb® Pro, 4.5 kg / for two dives 67 37 062
Dräger DiveSorb® Pro, 18 kg / for eight dives 67 37 109Halocarbon grease (28 g per tube) 65 90 212Silicone grease W410 (100 g per tube) for mouthpiece 15 95 008
Notes
08 | Dräger LAR 5002
Not all products, features, or services are for sale in all countries.Mentioned Trademarks are only registered in certain countries and not necessarily in the countryin which this material is released. Go to www.draeger.com/trademarks to find the current status.
CORPORATE HEADQUARTERSDrägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germanywww.draeger.com
REGION DACHDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected] EUROPEDräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected].
REGION MIDDLE EAST, AFRICADräger Safety AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 [email protected] ASIA PACIFICDraeger Singapore Pte. Ltd.61 Science Park RoadThe Galen #04-01Singapore 117525Tel: +65 6872 9288Fax: +65 6259 [email protected].
REGION CENTRALAND SOUTH AMERICADraeger Panamá ComercialS. de R.L.59 East Street, Nuevo Paitilla,House 31, San Francisco TownPanama City, PanamaTel +507 377-9100 / Fax [email protected].
Locate your Regional SalesRepresentative at:www.draeger.com/contact
91 0
2 57
2 |
19.0
6-2
| H
Q |
PP
| S
ubje
ct to
mod
ifica
tions
| ©
201
9 D
räge
rwer
k AG
& C
o. K
GaA