MINO ⅝.fi CURVE suspended

7
MINO 2.5 CURVE surface / suspended mounting instructions US-468MIN2R00000-R010 L total = L channel + ⅝" for two endcaps, for fixtures that aren’t a full circle L total = L channel, for fixtures that are a full circle and don’t have endcaps Fixture Length 5' Example 10' Example surface suspended suspended direct direct / indirect 20' Example 90° 90° 45° 45° 45° R 118 ⅛" 45˚ R 118 ⅛" 90˚ R 59" 45˚ R 59" 90˚ R 29 ½" 45˚ R 29 ½" 90˚ 2 ⅜" 3 ⅛" 2 ⅜" 3 ⅛" 2 ⅜" WARNING: For your safety read and understand these instructions completely before starting in- stallation. Disconnect power supply before instal- ling, servicing or checking. Retain these instruc- tions for ordinary and special maintenance and servicing purposes. Do not touch the LEDs! Wear ESD protective clothing. IMPORTANT: This fixture must be installed by a qualified electrician in accordance with the Natio- nal Electric Code and all local codes and prac- tices. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. These codes should be carefully studied before starting work. Mounting hardware supplied by others. We reserve the right to change our products at any time. Current information is available at xalusa.com. NOMINAL RADIUS DIAMETER CIRCUMFER. Ø 5' 29 ½" Ø 59" 15' 5" Ø 10' 59" Ø 118 ⅛" 30' 10" Ø 20' 118 ⅛" Ø 236 ¼" 61' 10" DIMENSIONS R 29 " R 59" R 118 " 0 - 45° 89 ⅜" 0 - 90° 81 11/16" 165 3/16" 0 - 135° 52 3/16" 106 11/16" 215 13/16" 0 - 180° 56 ½" 115 ½" 233 ⅝" cutout W 2 ⅝" R 2 ⅜" 3 1/16" XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 1 / 7 MI-V04 10/16/19

Transcript of MINO ⅝.fi CURVE suspended

Page 1: MINO ⅝.fi CURVE suspended

MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010

L total = L channel + ⅝" for two endcaps, for fixtures that aren’t a full circleL total = L channel, for fixtures that are a full circle and don’t have endcaps

Fixture Length

5' Example

10' Example

surface suspended suspendeddirect direct / indirect

20' Example

90°

90°

45°

45°

45°

R 118 ⅛" 45˚

R 118 ⅛" 90˚

R 59" 45˚

R 59" 90˚

R 29 ½" 45˚

R 29 ½" 90˚

2 ⅜"

3 ⅛

"

2 ⅜"

3 ⅛

"

2 ⅜"

WARNING: For your safety read and understand these instructions completely before starting in-stallation. Disconnect power supply before instal-ling, servicing or checking. Retain these instruc-tions for ordinary and special maintenance and servicing purposes.

Do not touch the LEDs! Wear ESD protective clothing.

IMPORTANT: This fixture must be installed by a qualified electrician in accordance with the Natio-nal Electric Code and all local codes and prac-tices. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. These codes should be carefully studied before starting work.Mounting hardware supplied by others.

We reserve the right to change our products at any time. Current information is available at xalusa.com.

NOMINAL RADIUS DIAMETER CIRCUMFER.

Ø 5' 29 ½" Ø 59" 15' 5"Ø 10' 59" Ø 118 ⅛" 30' 10"Ø 20' 118 ⅛" Ø 236 ¼" 61' 10"

DIMENSIONS

R 29 1/2" R 59" R 118 1/8"0 - 45° 89 ⅜"0 - 90° 81 11/16" 165 3/16"0 - 135° 52 3/16" 106 11/16" 215 13/16"0 - 180° 56 ½" 115 ½" 233 ⅝"

cutout W 2 ⅝"

R

2 ⅜"

3 1/16"

XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 1 / 7MI-V04 10/16/19

Page 2: MINO ⅝.fi CURVE suspended

MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010

cutout W 2 ⅝"

cutout W 2 ⅝"

1 2 3Surface mounted option / Place the fixture in the desired position on the ceiling

Mark or score the position

XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 2 / 7MI-V04 10/16/19

Page 3: MINO ⅝.fi CURVE suspended

MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010

4

7

5

8 9

6

10 11 12

Surface / suspended option Screw on endcap

Option 1 / MINO 2.5 CURVE channel to MINO 2.5 CURVE channel13 14.1

Connect inset to channel

Click in grounding

Connect power to inset

Put on cover

Flex conduit supplied by others

Testing the current:Max. 0.5 ohm resistance!

15.1 17.116.1Insert the pegs into the channel Install the channel connector piece Screw connector piece to channel

1/8"

XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 3 / 7MI-V04 10/16/19

Page 4: MINO ⅝.fi CURVE suspended

MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010

Suspended version / Thread suspension cables through bracket

22.2 23.2 24.2 Apply adhesive to the inside of the channel seam

20.2 21.2Option 2 / MINO 2.5 CURVE channel to MINO 2.5 channel

18.1 19.1

Screw connector piece to channel

Screw channels together

Screw channels together

28 29 30Insert bracket into junction box

Junction box supplied by others

Thread the suspension cable through the cover plate

Screw bracket to junction box

1/8"

25.2 26.2 27

XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 4 / 7MI-V04 10/16/19

Page 5: MINO ⅝.fi CURVE suspended

MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010

41 42 43

78"10 ×

158"20 ×

Connect the power to the inset

31

34

36

32

35

33

37

38 39 40

Thread the lamp cable up through the cover plate

Thread lamp cable through bracket

Lamp cable

Bracket

Screw on strain relief The cover plate clicks onto the bracket via springs

Maximum load per rope: 22lbs

max. 78"

Click in grounding

Junction box(supplied by others)

Strain relief

Power feed

Bracket

Cover plate

Lamp cable

Cable suspension

Make sure all components are grounded!

Springs

Bracket

Cover plate

Suspension cable

Lamp cable

Cover plate

XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 5 / 7MI-V04 10/16/19

Page 6: MINO ⅝.fi CURVE suspended

MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010

44 45 46Connect inset to channel Testing the current:Max. 0.5 ohm resistance!

no dimmingno emergency circuit

dim 0-10 V (5%)no emergency circuit

Hi-lume 3D (1%)3-wire hot dimno emergency circuit

Hi-lume 3D (1%)digital dimno emergency circuit

SUSPENSION CABLE

SUSPENSION CABLE

SUSPENSION CABLE

DIM+ (red)DIM- (orange)

dim line DH (orange)

E1 (red)E2 (orange)

FEEDneutral (white)ground (green)phase (black)

FEEDneutral (white)ground (green)phase (black)dim + (violet)dim - (gray)

FEEDneutral (white)ground (green)phase (black)dim line DH (orange)

FEEDneutral (white)ground (green)phase (black)E1 (violet)E2 (gray)

Inset wiring without emergency circuit

XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 6 / 7MI-V04 10/16/19

Page 7: MINO ⅝.fi CURVE suspended

MINO 2.5 CURVE surface / suspended mounting instructionsUS-468MIN2R00000-R010

EN

-

Keep these installation instructions in a safe place as reference for any future maintenance works.1. The lamp is not suitable for outdoor use.2. The lamp may only be used with a safety guard.3. Damaged protection glasses and covers have to be replaced immediately.4. 5. No liability is accepted for any subsequent change of the luminaire.6. LEDs are high-quality electronic components! Please avoid touching by hand the LED light emitting surface while assemblying or replacing parts and during maintenance work. 7.8.9.

The LED circuit must always be closed, before the converter is connected to the main power. XAL does not assume any liability for damages resulting from nonobservance of this rule.

FR avant de changer les lampes (si applicable) ou avant de realiser travaux (p.ex nettoyage) a la luminaire. Attendre jusqu‘à ce que la luminaire et les lampes ont frâichit completement. Merci de bien vouloir vous référer aux notes d‘installation

utiliser encore un produit de nettoyage sans alcol qui ne fraye pas le material. Garder cette notice de montage pour possibles travaux de maintenance.La luminaire n‘ est pas apte pour l‘utilizage extrerieur.Utilizer la luminaire seulement avec un dispositif de sécuritéChanger immédiatement des verres de sécurité defectes ou bien des écrans de protection.

Evitez tout contact de la lampe avec de produits chimiques corrosifs. Des LEDs sont des composants électroniques de haute qualité! Eviter tout contact direct de la surface de sorti de lumière de la LED avec les mains lors du montage ou des les travaux de maintenance de la lampe.

Il faut que le circuit de LED soit fermé avant de connecter le convertisseur. XAL ne assume pas la garantie si cette norme ne se respecte pas.

ES La instalación, la puesta en marcha y el mantenimiento sólo deben realizarse por personal especializado considerando esta guía de instalación y todas las normas y reglamentaciones vigentes. Asegurarse de la aptitud eléctrica, mecá-

en esta (p.ej. Limpieza). Esperar hasta que se enfríen la luminaria y la lámpara completamente. Tener en cuenta las instrucciones de montaje del fabricante al colocar, cambiar y utilizar lámparas convencionales. Para la limpieza de la luminaria

La luminaria no es apta para utilizarla en el exterior.La luminaria sólo debe accionar con un dispositivo de seguridad. Cambie de inmediato los vidrios y las tapas de protección dañados.

El circuito LED debe ser cerrado antes de conectar el convertidor. XAL no asume garantía si esta norma no se respete.

We reserve the right to change our products at any time. Current information is available at www.xalusa.com.Nos reservamos en todo momento el derecho de realizar cambios en nuestros productos. n nuestra página web www.xalusa.com siempre se encontrarán datos actuales.

Rev.:001/2014-12-31

Die Leuchte darf nur mit ihrer vollständigen Schutzabdeckung betrieben werden!The lamp is only to be operated with its full protective covering!L‘apparecchio necessita del relativo vetro di protezione!Sólo usar la luminaria con su cobertura de seguridad completa!

Don‘t touch the LED

Recommended room temperature: 77 °F.Temperatura ambiente recomendada: 25 °C.Température ambiante recommandée: 25 °C.

Use gloves.Use guantes.Utiliser des gants.

1.2.3.4.5.6.7.8.9.

1.2.3.4.5.6.7.8.9.

XAL Inc. 150 Hawley Rd. Oxford, CT 06478 T: +1 203.262.9990 www.xalusa.com 7 / 7MI-V04 10/16/19