Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop,...

23
g 2 p HRS Optics with Septum Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12

Transcript of Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop,...

Page 1: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

g2p HRS Optics

with Septum Min Huang

Duke University, TUNL

On Behalf of the E08-027 g2p collaboration

Hall A Analysis Workshop, 12/12/12

Page 2: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

E08-027 g2

p & the LT Spin PolarizabilitySpokespeople

Alexandre Camsonne (JLab)

Jian-Ping Chen (JLab)Don Crabb (UVA)Karl Slifer (UNH)

Post DocsKalyan AlladaJames MaxwellVince SulkoskyJixie Zhang

Graduate StudentsToby BadmanMelissa CummingsChao GuMin Huang Jie LiuPengjia ZhuRyan Zielinski

Page 3: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

OutlineGeneral HRS Optics

Intro of g2p Optics Goals and designTarget and SeptaData taken

Status of Optics data calibration

Page 4: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

HRS Optics with SeptumTarget plane info Focal plane info (VDC tracking)Multi-dimensional polynomialsFirst order approximation

Target Septum

VDC

Sieve slitHall A Analysis Workshop, Dec 2012 Min

Huang

Q1

Q2

Dipole

Q3

0 0

0 0

0 0

0 0

0

| ( | ) ( | )

( | ) ( | ) ( | )

( | ) ( | )

( | ) ( | )fp

xx x x x x

xy

y y y y

y

Top View

Target planeFocal

plane

Page 5: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

g2p OpticsWhat is a good first order matrix for g2p?

(x|θ0) very small point to point HRS focusing

g2p goal: syst. uncertainty of cross section 5%Optics goal

Syst. uncertainty of θ: 0.5% Contribution to cross section uncertainty: 2%Requires good uncertainty of angle (horizontal)

reconstructionMomentum uncertainty not sensitive, but not hard to

achieve 10-4 level

Page 6: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

g2p OpticsFirst order matrix

Matrix elements can be adjusted by tuning quarupole fields

Optics designTuned Quadrupole fields in SNAKE to satisfy the goalsNew I vs P0 setting of HRS Quads for g2p experimentOnline database from SNAKE model

0

0 0

0

0 0

0 0

| ( | )

( | ) ( | ) ( | )

( | ) ( | )

( | ) ( |

( |

)

)

fptg

xx x x x

xy

y y y y

y

x

Target planeFocal

plane

Thanks to John Lerose for his help!

Page 7: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

g2p Optics --Target Configuration

Target Insert

Target Nose (Al)

Carbon Foil

4.2 cm

Beam

….

LHe Shield (Al)

….

NH3CH2Carbon

NH3

Dummy

Carbon

2.9 cm

Page 8: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Designed symmetric left and right septum

Each septum has top and bottom 3 pairs of coils

48-48-16 1st good septum

g2p Optics --Septa

Courtesy Jixie Zhang

Beam goes into the pipe

Turns:48

48

16

Page 9: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

Right septum caught on fire twice

Right septum field changed a lot, while left one field also got impacted

Optics data on each situations

g2p Optics --Septa

Only right top coils changed

1) Good 2) Bad 3) Very Bad

48-48-16 40-32-16 40-00-16 Talk by Melissa Cummings in Hall A Collaboration Meeting

Page 10: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

g2p Optics DataDelta scan with sieve in, C foil: databasePointing, C foil in LHe or CH2 foil: central scattering

angleFast & slow rasters, C foil: acceptanceBeam position scan, C foil: small angle ~6°, short

production target ~3cm

12.5°

Top View

Standard g2p

Beam Horizontal Scan

Target

Sieve slit

Page 11: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

11 total sets of data at 6°Beam energy: 2.254GeV, 1.706 GeV, 1.158 GeV Target field: 0, 2.5T, 5T3 different septa situations

2 sets of 0 target field data: base for target field on situationsBeam energy 2.254 GeVRight septum: 48-48-16 (1), 40-00-16 (3)

g2p Optics Data

Page 12: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

LHRS Before Calibration (1st septum)-3%

-2%

0%

2% 3%

With database from SNAKE model

Page 13: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

Calibration Steps1. Tg_y vs. Tg_ph vetex cut for the whole run

Page 14: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

Calibration Steps2. Cut on each hole3. Cut carbon elastic for each hole

C12 elastic

Contamination, like Al elastic

C12 1st excited

Page 15: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

LHRS Angle (1st septum)

-3%

-2%

0%

2% 3%

Page 16: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

LHRS Matrix Dp calibration

Before

AfterFull Acceptance Scan

Page 17: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

RHRS Angle (1st septum)-3.5%

-1%

0%

2% 3.5%

Page 18: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

RHRS Momentum (1st septum)Full Acceptance Scan

Page 19: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

LHRS Angle (3rd septum)Before All delta

scan combined

Courtesy Chao Gu

After

Page 20: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

LHRS Momentum (3rd septum)

Courtesy Chao Gu

-3% -1%

0%

1% 3%

Full Acceptance Scan

Page 21: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

Performance SummaryBeam energy 2.254 GeV, no target field, 1st & 3rd septum,

carbon foil

Reference: beam energy 845 MeV, angle 16°, no septum standard HRS, carbon foil (Hall A NIM)

Resolution (RMS) LHRS (1st )

RHRS (1st )

LHRS (3rd )

In-plane Angle [mrad] 0.9 0.9 0.7

Out-of-plane Angle [mrad]

1.5 1.6 1.4

Momentum [(p-p0)/p0] 1.3x10-4 2.0x10-4 1.8x10-4

Resolution (RMS)

In-plane Angle [mrad] 0.8

Out-of-plane Angle [mrad]

2.5

Momentum [(p-p0)/p0] 1.1x10-4

* FWHM=2.3548*RMS

Page 22: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

What to doTarget y calibration for each settingPointing: improve the accuracy of central angleRHRS 3rd septum 40-00-16 settingWrap up 0 target field results with better accuracy &

resolution

Continue on target field ON situations

Talk by Jixie Zhang on HRSMC simulation

Page 23: Min Huang Duke University, TUNL On Behalf of the E08-027 g2p collaboration Hall A Analysis Workshop, 12/12/12.

Hall A Analysis Workshop, Dec 2012 Min Huang

Thanks!I would like to thank the following people for their

guidance and helpful discussions!John LeroseJian-ping ChenNilanga LiyanageJixie Zhang, Vince Sulkosky, Chao GuJin Huang, Xin Qian, Yi Qiang, Kiad Saenboonruang, Huan

Yao, Zhihong Ye