Milk Analyzers - labec.com.au · Milk Analyzers M-MIA-SLC / Standard Low Cost Milk Analyzer M-MIA-S...

3
www.labec.com.au Laboratory Equipment Pty Ltd email: [email protected] Ph: 02 9560 2811 Fax: 02 9560 6131 Serving the Scientific, Medical and Research industries since 1945 2014 Milk Analyzers M-MIA-SLC / Standard Low Cost Milk Analyzer M-MIA-S / Standard Milk Analyzer LABEC Milk Analyzers are user-friendly, rapid analysers which can be applied for measurement of fat (FAT), solids non-fat (SNF), density, proteins, lactose, salts, water content percentages, temperature (°C), freezing point, pH, conductivity, as well as total solids directly after milking, at collecting stage and during processing. Model M-MIA-SLC Measuring time Measuring parameters Standard complete Additional options 90 Sec FAT: 0.01% ~ 25% SNF: 3% ~ 15% Density: 1015 ~1040kg/m3 Proteins: 2% ~ 7% Lactose: 0.01% ~ 6% Water content: 0% ~ 70% Temp. of milk: 1°C ~ 40°C Freezing point: -0.400°C ~ 0.700°C Solids: 0.4 – 1.5% 1. Sample visualization on LED display 2. Possibility to measure 1 sample - 90 seconds 3. Adapter 220-110 V 4. Spare silicone tubes 5. Syringe 6. Plastic sample holder 7. Calibrations Cow, Sheep, and UHT milk 8. Operation Manual 9. Cardboard transport case 10. CD – Service pack No Additional options Model Measuring time Measuring parameters Standard complete Additional options Ph Option Conductivity M-MIA-S 60 Sec FAT: 0.01% ~ 25% SNF: 3% ~ 15% Density: 1015 ~ 1040kg/m3 Proteins: 2% ~ 7% Lactose: 0.01% ~ 6% Water content: 0% ~ 70% Temp. of milk: 1°C ~ 40°C Freezing point: -0.400°C ~ 0.700°C Solids: 0.4 ~ 1.5% 1. Sample visualization on LCD display(green) 2. Possibility to measure 1 sample – 90 seconds (option 60 seconds) 3. Adapter 220-110 V 4. Spare silicone tubes 5. Syringe 6. Plastic sample holder 7. Calibrations Cow, Sheep, and UHT milk 8. Operation Manual 9. Cardboard transport case 10. CD – Service Pack High Fat 45% (High Density) 90 Sec M-MIA-SLC M-MIA-S

Transcript of Milk Analyzers - labec.com.au · Milk Analyzers M-MIA-SLC / Standard Low Cost Milk Analyzer M-MIA-S...

Page 1: Milk Analyzers - labec.com.au · Milk Analyzers M-MIA-SLC / Standard Low Cost Milk Analyzer M-MIA-S / Standard Milk Analyzer LABEC Milk Analyzers are user-friendly, rapid analysers

www.labec.com.au

Laboratory Equipment Pty Ltdemail: [email protected] Ph: 02 9560 2811 • Fax: 02 9560 6131

Serv

ing

the

Scie

ntifi

c, M

edic

al a

nd R

esea

rch

indu

stri

es s

ince

194

5

2014

Milk Analyzers

M-MIA-SLC / Standard Low Cost Milk Analyzer

M-MIA-S / Standard Milk Analyzer

LABEC Milk Analyzers are user-friendly, rapid analysers which can be applied for measurement of fat (FAT), solids non-fat (SNF), density, proteins, lactose, salts, water content percentages, temperature (°C), freezing point, pH, conductivity, as well as total solids directly after milking, at collecting stage and during processing.

Model M-MIA-SLCMeasuring time Measuring parameters Standard complete Additional options

90 Sec

FAT: 0.01% ~ 25%SNF: 3% ~ 15%Density: 1015 ~1040kg/m3Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70%Temp. of milk: 1°C ~ 40°CFreezing point: -0.400°C ~ 0.700°CSolids: 0.4 – 1.5%

1. Sample visualization on LED display2. Possibility to measure 1 sample - 90 seconds3. Adapter 220-110 V4. Spare silicone tubes5. Syringe6. Plastic sample holder7. Calibrations Cow, Sheep, and UHT milk8. Operation Manual9. Cardboard transport case10. CD – Service pack

NoAdditional

options

ModelMeasuring time Measuring parameters Standard complete Additional options

Ph Option

Conductivity

M-MIA-S

60 Sec

FAT: 0.01% ~ 25%SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70%Temp. of milk: 1°C ~ 40°CFreezing point: -0.400°C ~ 0.700°CSolids: 0.4 ~ 1.5%

1. Sample visualization on LCD display(green)2. Possibility to measure 1 sample – 90 seconds (option 60 seconds)3. Adapter 220-110 V4. Spare silicone tubes 5. Syringe6. Plastic sample holder7. Calibrations Cow, Sheep, and UHT milk8. Operation Manual9. Cardboard transport case10. CD – Service Pack

High Fat 45% (High Density)

90 Sec

M-MIA-SLC M-MIA-S

Page 2: Milk Analyzers - labec.com.au · Milk Analyzers M-MIA-SLC / Standard Low Cost Milk Analyzer M-MIA-S / Standard Milk Analyzer LABEC Milk Analyzers are user-friendly, rapid analysers

www.labec.com.au

Laboratory Equipment Pty Ltdemail: [email protected] Ph: 02 9560 2811 • Fax: 02 9560 6131

Serv

ing

the

Scie

ntifi

c, M

edic

al a

nd R

esea

rch

indu

stri

es s

ince

194

5

2014

SPECIFICATIONS Milk Analyzers

Environmental conditions:• Ambient air temperature: 10°C ~ 40°C (option 43°C) • Milk temperature: 1°C ~ 40°C • Relative humidity: 30% ~ 80%

ElEctrical ParamEtErs: • AC Power Supply voltage: 220V/110VDC • Power Supply voltage: 12V to 14,2V • Power Consumption: 30W max.

mEchanical ParamEtErs: • Dimensions: W290 x D300 x H330mm • Weight: < 5 kg

• Embedded printer. • Embedded keypad. • Integrated weight scales. • Additional serial printer. • Matrix printer (option). • External keypad (option).

Features:• Peristaltic pump – automatic cleaning. • Knee-joint (mobile) input pipe. • Adjustable to the input pipe pH probe holder. • Possibility of using different sample holders. • Integrated pH and conductivity measuring. • Self calibration without computer.

M-MIA-A / Standard Automatic Milk Analyzer

M-MIA-CC / Milk Collecting Centre

Model M-MIA-AMeasuring time Measuring parameters Standard complete Additional options

Ph Option

Conductivity

60 Sec

FAT: 0.01% ~ 25% (option 45%)SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3 (1160 kg/m3 option)Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70%Temp. of milk: 1°C ~ 40°CFreezing point: -0.400°C ~ 0.700°C

1. Sample visualization on LCD display2. Possibility to measure 1 sample – 90 seconds (option 50 seconds)3. Adapter 220-110 V4. Peristaltic pump 5. Spare silicone tubes6. Syringe7. Plastic sample holder8. Calibrations Cow, Sheep and UHT milk9. Operation Manual10. Cardboard transport case11. CD – Service pack

High Fat 45% (High Density)

90 Sec

Model M-MIA-CCMeasuring time Measuring parameters Standard complete Additional options

Ph Option

Conductivity

Integrated scales

Accumulator with charger

Real time clock

Remote display

High Fat 45% (High Density)

1. Sample visualization on LCD display2. Possibility to measure1 sample – 50 seconds (option 30 seconds)3. Adapter 220-110 V 4. Peristaltic pump 5. Spare silicone tubes 6. Syringe7. Plastic sample holder 8. Calibrations Cow, Sheep, and UHT milk 9. Operation Manual 10. Cardboard transport case11. CD – Service pack

FAT: 0.01% ~ 25% (option 45 %) SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3 (1160kg/m3 option)Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70% Temp. of milk: 1°C ~ 40°C Freezing point: -0.400°C ~ 0.700°C Solids: 0.4 ~ 1.5%

30 Sec

50 Sec

Page 3: Milk Analyzers - labec.com.au · Milk Analyzers M-MIA-SLC / Standard Low Cost Milk Analyzer M-MIA-S / Standard Milk Analyzer LABEC Milk Analyzers are user-friendly, rapid analysers

www.labec.com.au

Laboratory Equipment Pty Ltdemail: [email protected] Ph: 02 9560 2811 • Fax: 02 9560 6131

Serv

ing

the

Scie

ntifi

c, M

edic

al a

nd R

esea

rch

indu

stri

es s

ince

194

5

2014

SPECIFICATIONS Milk Analyzers

Features:• Peristaltic pump – automatic cleaning. • Knee-joint (mobile) input pipe. • Adjustable to the input pipe pH probe holder. • Possibility of using different sample holders. • Possibility of connecting pH probe. • Integrated pH and conductivity measuring. • Self calibration without computer.

Environmental conditions:• Ambient air temperature: 10°C ~ 40°C (option 43°C) • Milk temperature: 1°C ~ 40°C • Relative humidity: 30% ~ 80%

ElEctrical ParamEtErs: • AC Power Supply voltage: 220V/110VDC • Power Supply voltage: 12V to 14,2V • Power Consumption: 30W max.

mEchanical ParamEtErs: • Dimensions: W250 x D290 x H330mm • Weight: < 4 kg

M-MIA-LA

M-MIA-LA / Laboratory Automatic Milk Analyzer

Model M-MIA-LAMeasuring time Measuring parameters Standard complete Additional options

Ph Option

Conductivity

Integrated scales

Accumulator with charger

Real time clock

Remote display

High Fat 45% (High Density)

1. Sample visualization on LCD display2. Possibility to measure1 sample – 50 seconds (option 30 seconds)3. Adapter 220-110 V 4. Peristaltic pump 5. Spare silicone tubes 6. Syringe7. Plastic sample holder 8. Calibrations Cow, Sheep, and UHT milk 9. Operation Manual 10. Cardboard transport case11. CD – Service pack

FAT: 0.01% ~ 25% (option 45 %) SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3 (1160kg/m3 option)Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70% Temp. of milk: 1°C ~ 40°C Freezing point: -0.400°C ~ 0.700°C Solids: 0.4 ~ 1.5%

30 Sec

50 Sec

Key features:• User-friendly, simple in operation, maintenance,

calibration and installation.• Portable and compact design. • Very small quantity of milk required. • Low power consumption. • No use of hazardous chemicals. • One year warranty. • Measuring accuracy adjustment can be done

by the user RS 232 Interface.• ESC POS Printer Support. • Two samples self-calibration.

M-MIA-CC

M-MIA-A