Microbially Influenced Corrosion

38
Microbially Influenced Corrosion Sandy Sharp Columbia, MD, USA TAPPI Microbiology and Microbial Technology Committee Webinar, October 29,2014

Transcript of Microbially Influenced Corrosion

Page 1: Microbially Influenced Corrosion

Microbially Influenced Corrosion

Sandy SharpColumbia, MD, USA

TAPPI Microbiology and Microbial Technology Committee Webinar, October 29,2014

Page 2: Microbially Influenced Corrosion

Introduction to bacteria

Bacteria are tiny single-cell organisms typically 0.5–5.0 microns in length, i.e. about 40 could be laid end to end within 1/1000 of an inch

Many mill waters are hospitable to bacterial growth Warm, neutral pH containing nutrients (C, N, P) from

makeup water, air, additives or process contamination Almost all types of bacteria can be found almost

everywhere If their environment is hospitable they will multiply

2

Page 3: Microbially Influenced Corrosion

Planktonic and Sessile bacteria

Because most bacteria found in mill waters exude sticky slime (extracellular polysaccharide), they tend to stick to wetted surfaces and to trap particles that float by

Planktonic bacteria (floating in solution) do not cause corrosion, but Sessile bacteria (attached to metal surfaces) can influence corrosion1. Directly: by exuding corrosive metabolic products2. Indirectly: by restricting access of oxygen to the metal

beneath a deposit and initiating crevice corrosion 3

Page 4: Microbially Influenced Corrosion

Sessile bacteria form biofilms

Sessile bacteria and the materials that adhere to them form biofilms

PM biofilm sloughing can produce sheet defects HX biofilms hinder heat transfer, increase T 4

Xavier et al, 2004

Page 5: Microbially Influenced Corrosion

Microbially Influenced Corrosion under biofilm

5

Borenstein, 1994

Biofilm hinders O2 penetration; anaerobic bacteria can live underneath aerobic bacteria

RDS in corrosion is electron-consuming process, which can support fast dissolution of small anodic area

Page 6: Microbially Influenced Corrosion

Once initiated, crevice corrosion under a biofilm becomes self-sustaining

6

Hydrolysis of the dissolved metal makes crevice solution more acidic (more corrosive) 2Fe++ + 4OH- → 2Fe(OH)2 (in alkali) or Fe++ + 2H2O → Fe(OH)2 + 2H+ (in acid)

Anions diffuse to dissolution site to maintain charge balance. Cl- is typically most mobile. Increasing [Cl-] makes the crevice solution more corrosive

Solids from oxidation of dissolved metal or hardness deposits make biofilm even less permeable to O2 penetration, making crevice solution more corrosive

Page 7: Microbially Influenced Corrosion

Equipment susceptible to Microbially Influenced Corrosion (MIC)

7

MIC occurs only on metals in contact with water, e.g. equipment touched by white water, mill water, cooling water or fire water Gasoline, oil and cutting lubricants contain water and

can also support MIC Stagnant and low-flow areas are particularly

vulnerable e.g. in fire water, under deposits

Page 8: Microbially Influenced Corrosion

Identifying Microbially Influenced Corrosion

MIC is probably the most difficult form of corrosion to identify in a pulp and paper mill

“MIC does not produce any unique type of corrosion and there are no definitive tests or specific observations that can be used to detect MIC”, Brenda Little, FNACE (2011)

MIC diagnosis must rely on multiple consistent pieces of evidence that all point to MIC as the cause

8

Page 9: Microbially Influenced Corrosion

Diagnostic questions to determine if corrosion is caused by bacteria

1. Can (does) the water support the growth of planktonic bacteria that can cause MIC?

2. Do the corrosion products contain MIC-causing bacteria or chemicals produced by MIC bacteria?

3. Does the corrosion damage show features characteristic of MIC?

4. Could recent operational changes have enhanced the growth of microorganisms? We will now review the tools available to examine

each of these identifiers9

Page 10: Microbially Influenced Corrosion

Identifier 1: Planktonic MIC bacteria in water samples (1)

1. Count viable bacteria grown on lab media Difficult to simulate complexity of field environment

2. Measure total microbial activity by analyzing the concentration of a molecule (ATP) found in all living cells Many chemicals in P&P environments interfere with ATP

test results. Use only with careful controls10

Page 11: Microbially Influenced Corrosion

Identifier 1: Planktonic MIC bacteria in water samples (2)

3. Semi-quantitative field tests for bacteria that can cause MIC

11

e.g. Low-nutrient bacteriaIron-related bacteria

Anaerobic or facultatively-anaerobic bacteria

Acid-producing bacteria

Sulfate-reducing bacteria

Page 12: Microbially Influenced Corrosion

Identifier 1: Planktonic bacteria in water samples (3)

Remember that concentrations of planktonic bacteria rarely correlate with concentrations of the sessile bacteria that cause corrosion (Wranghamand Summer, Paper 2780 at CORROSION/2013)

∴Absence of high concentrations of planktonic bacteria that could cause MIC does not prove that corrosion was not initiated by MICBut, a high concentration of a type of planktonic bacteria that could cause MIC confirms that MIC is a possible mechanism

12

Page 13: Microbially Influenced Corrosion

Identifier 2: Presence of MIC bacteria in deposits -chemical indicators

13

Example: Sulfate-Reducing Bacteria anaerobically reduce SO4 to S2- or to H2S; produce black FeS corrosion products and H2S Sulfur accumulation Smell of H2S when a deposit is removed (e.g. on

paper machine making unbleached kraft) Note SRB can live at temperatures to 100°C

Page 14: Microbially Influenced Corrosion

Identifier 2: Presence of MIC bacteria in deposits -“Modern Molecular Methods”

14

DNA analysis developed for forensics and medical research, used for MIC since ~2010

DGGE compares populations, identifies abundant microorganisms

DAPI and qPCR quantitate living + dead cells FISH quantitates live bacteria and Archaea

Use extreme care to avoid sample contamination Rely on analytical laboratories that are accredited

and experienced May eventually replace traditional assays

Page 15: Microbially Influenced Corrosion

Identifier 3: Corrosion morphologies characteristic of MIC (1)

15

Pits concentrated at weld seams Hemispherical pits under hemispherical deposits Isolated deep pits surrounded by shallow pits Pits with small openings leading to large cavities Connected sub-surface cavities and tunnels Amorphous or nanocrystalline deposits

Page 16: Microbially Influenced Corrosion

Identifier 3: Corrosion morphologies characteristic of MIC (2)

16

Some types of bacteria produce specific corrosion morphologies e.g. Fe++→Fe+++ bacteria:

orange-red or brown shiny slime and pits under hard tubercles (blisters to stalks)

Page 17: Microbially Influenced Corrosion

Identifier 4: Operational changes that could have enabled bacteria to multiply

17

MIC often found after changes in biocide treatment or after process changes that affect temperature or O2 concentration Monitoring bacterial populations in plant waters can

provide early warning of changes in planktonic ecosystems

Corrosion can continue after the hospitable environment has been removed, e.g. Gallionella after hydrostatic testing

Corrosion tests rarely predict MIC

Page 18: Microbially Influenced Corrosion

Identifier 4: Operational changes that could have enabled bacteria to multiply

18

Licina’s biofouling monitor (BIoGEORGE™) has sometimes proved useful

Biofouling monitor measureseffect of biofilm growth

on resistance between electrodes and on electrochemical noise (corrosion currents) between

nominally identical electrodes Licina,

Paper 1442 at CORROSION/2001 Paper 2243 at CORROSION/2013

Page 19: Microbially Influenced Corrosion

Preventing MIC

19

Cause and mechanism of MIC must be understood before a remediation plan can be developed

To make water systems inhospitable, add biocide chemicals to kill or deactivate bacteria

Biofilms that have incorporated inorganic materials become very difficult to remove Try shock treatments with oxidizing biocides or high-

pressure water jetting Changing MOC is generally cost-prohibitive but

minor redesigns can eliminate vulnerable areas e.g. dead legs, crevices at flange joints

Page 20: Microbially Influenced Corrosion

Case History: Time to failure of mill equipment

20

Item Material Operating Temperature Time to 1st leak

HX 1 304L 208°F, (98°C) 9 months

HX 2 304L 221°F, (105°C) 12 months

HX 3 304L 185°F, (85°C) 24 months

WW tank 316L 149‐158°F, (65‐70°C) <36 months

HW piping 1 304L 185‐221°F, (85‐105°C) <36 months

HW piping 2 304L 185‐221°F, (85‐105°C) <48 months

Page 21: Microbially Influenced Corrosion

Case History: Planktonic bacteria in mill waters

21

Water Low‐Nutrient Bacteria, counts/mL

ATP analysis,Relative Light Units

Filtered make‐up water >104 Not tested

Make‐up water after biocide treatment 103 ‐ 104 55, 35, 27

Recirculated cooling water after biocide treatment

103 ‐ 104 62, 49, 52

Potable water 100 – 101 70, 85, 86

Page 22: Microbially Influenced Corrosion

Case History: ATP data affected by interferences

ATP indicated very low bacteria concentrations, but algae could be seen

22

Page 23: Microbially Influenced Corrosion

Case History: Corrosion features characteristic of MIC in White Water Piping

23

Slow leaks from small perforations at weld

Corrosion deposits inside weld seam

Page 24: Microbially Influenced Corrosion

Case History: Corrosion features characteristic of MIC in White Water Tank (1)

24

Rust leaking from corrosion penetrations in weld attaching SS liner to steel White Water Tank

Cross-section: rounded corrosion at weld fusion line

Page 25: Microbially Influenced Corrosion

Case History: Corrosion features characteristic of MIC in White Water Tank (2)

25

Cross-section: Small surface opening to spherical pit

Cross-section: Sub-surface corrosion tunnels

Page 26: Microbially Influenced Corrosion

Case History: Analysis of corrosion products in HX 1

Outer layer of corrosion mound over a pit on ID of HX 1 sent for DNA (DGGE) testing 84% of identified bacteria were slime-formers

8% were nitrifying bacteria1.5% were iron-related bacteria

SEM/EDXA analysis showed corrosion deposits in HX 1 were mostly iron oxide but contained up to 11% S

[Cl-] in corrosion product samples was elevated from 1-4 mg/L to 1000 mg/L

26

Page 27: Microbially Influenced Corrosion

Case History: Corrosion features characteristic of MIC in HXs

27

Inlet Nozzle - cooler Outlet nozzle - hotter

Page 28: Microbially Influenced Corrosion

Case History: Corrosion features characteristic of MIC in HXs

28

Hemispherical pitsat weld seam

Cross-section:Hemispherical pit and sub-surface

corrosion

Cross-section: Large pit with small opening

Branching cracks

Page 29: Microbially Influenced Corrosion

Case History: Corrosion features characteristic of MIC in HVAC chillers

29

Shiny, slimy deposits

Page 30: Microbially Influenced Corrosion

Case History: Operational changes that could have allowed MIC to begin

Mill had reduced biocide concentrations to prevent cracking in cooling tower nozzles that had been attributed to the biocide

Long hot summers were causing the biocide to volatilize and decompose

Mill method for analyzing biocide concentration over-estimated real biocide concentrations

30

Page 31: Microbially Influenced Corrosion

Case History: Summary of results (1)

1. Growth of algae showed that “disinfected” mill waters could support bacterial growth

2. Mill waters contained high concentrations of planktonic Low-Nutrient Bacteria, which are able to cause MIC

3. HVAC Coolers (HXs cooled by mill water) contained shiny deposits that looked like microbial slime

4. Presence of slime-forming bacteria in outer layer of deposit indicated that bacterial slime could have been the deposit binder 31

Page 32: Microbially Influenced Corrosion

Case History: Summary of results (2)

5. Corrosion products enriched in S and yellow deposits around pits were consistent with growth of SRB at metal surface

6. Corrosion morphology was consistent with MIC: Rapid pitting that formed rounded cavities under rounded deposit mounds along weld seams

7. Pits with small mouths opening to large sub-surface cavities

8. Rounded sub-surface corrosion tunnels in WW tank

9. Corrosion deposit under Fe-rich outer layer was amorphous 32

Page 33: Microbially Influenced Corrosion

Case History: Summary of results (3)

10.Biocide dosages had been reduced to avoid unrelated problems and mill’s procedure for analyzing biocide concentration overestimated the real concentration

Cracks propagating from pits near welds looked like Cl- SCC or S– SC Maybe the production of H2S by SRB promoted

Sulfide Stress Cracking (typically fine, branched cracks that initiated from stress raisers in pits)

33

Page 34: Microbially Influenced Corrosion

Case History: Conclusions

Corrosion was identified as MIC because at least 10 consistent findings pointed to MIC as the cause of the corrosion

At our recommendation the mill is making a microbiological survey of its water systems, and installing biofilm monitors

These data will provide a basis for developing improved biocide programs to treat white water, make-up water, recirculated mill water and fire water 34

Page 35: Microbially Influenced Corrosion

Recommendation: Use strategies for identifying MIC developed by petroleum industry1. Q: Can (does) the water support the growth of

planktonic bacteria that can cause MIC?2. Q: Do the corrosion products contain MIC-causing

bacteria or chemicals produced by MIC bacteria?3. Q: Does the corrosion damage show features

characteristic of MIC?4. Q: Could recent operational changes have

enhanced the growth of microorganisms? MIC diagnosis must rely on multiple consistent pieces of

evidence that all point to MIC as the cause 35

Page 36: Microbially Influenced Corrosion

Bibliography Standard TM0212-2102 “Detection, Testing and

Evaluation of Microbially Influenced Corrosion on Internal Surfaces of Pipelines”, NACE International, 2012

“Microbiologically Influenced Corrosion – An Engineering Insight”, Javaherdashti, Springer, 2008

“Microbiologically Influenced Corrosion”, Little and Lee, Wiley, 2007

“Microbiologically Influenced Corrosion”, Borenstein, Industrial Press, 1994

“A practical manual on Microbiologically Influenced Corrosion”, Ed. Kobrin, NACE International, 1993 36

Page 37: Microbially Influenced Corrosion

Contact for follow-up questions

Dr. Sandy Sharp, FTAPPI, FNACE, [email protected]+1-410-209-014610001 Windstream Drive, Columbia, Maryland, USA 21044

37