Micro Contactor K0 - BENEDICT · 2020. 2. 7. · Main contacts Type K0-05D.. K0W05D.. AC1 I e (=I...

2
Benedict GmbH Tel.: +43 1 251 51-0 e-mail: [email protected] Lieblgasse 7, A-1220 Vienna Fax: +43 1 251 51-89 www.benedict.at D931Eb Technical data are subject to change without notice Technical Data acc. to IEC 60947-4-1 Technical Data for North America acc. to UL 508, Main contacts Type K0-05D.. K0W05D.. AC1 I e (=I th ) open at 40°C AC2, AC3 400V Fuse “Typ1” gL (gG) A A kW A 12 5 2,2 20 Cable cross-section solid flexible solid flexible Clamps per pole mm² mm² AWG AWG 0,5–1,5 0,5–1,5 20–14 20–14 2 Terminals Terminal screws Screw driver Tightening torque Pozidriv Nm M2,5 Pz1 0,6–0,8 Coil AC-operated Operation Range in multiples of control voltage U s Power consumption inrush hold VA VA 0,85–1,1 9 4 Main Contacts (cULus) Typ K0-05D.. K0W05D.. Rated operational current “General Use” Rated operational power of three-phase 110-120V motors at 60Hz (3ph) 200-208V 220-240V 277V Rated operational power of AC motors 110-120V at 60Hz (1ph) 200-208V 220-240V Fuse / Short-circuit current Rated voltage A hp hp hp hp hp hp hp A/kA V~ 12 ½ 1 1 ½ ¾ 30/5 300 Auxiliary Contacts (cULus) heavy pilot duty standard pilot duty AC DC B300 R300 Micro Contactor K0 Relay-size contactor, smallest in the world. >3 mm contact clearance acc. to IEC 60335-1 for Safety Applications. Reversing contactor with mechanical interlock. New!

Transcript of Micro Contactor K0 - BENEDICT · 2020. 2. 7. · Main contacts Type K0-05D.. K0W05D.. AC1 I e (=I...

Page 1: Micro Contactor K0 - BENEDICT · 2020. 2. 7. · Main contacts Type K0-05D.. K0W05D.. AC1 I e (=I th) open at 40°C AC2, AC3 400V Fuse “Typ1” gL (gG) A A kW A 12 5 2,2 20 Cable

Benedict GmbH Tel.: +43 1 251 51-0 e-mail: [email protected] 7, A-1220 Vienna Fax: +43 1 251 51-89 www.benedict.at

D93

1Eb

Technical data are subject to change without notice

Technical Data acc. to IEC 60947-4-1 Technical Data for North America acc. to UL 508,

Main contacts Type K0-05D..K0W05D..

AC1 Ie (=Ith) open at 40°C AC2, AC3 400V

Fuse “Typ1” gL (gG)

AA

kWA

1252,2 20

Cable cross-sectionsolidflexiblesolidflexibleClamps per pole

mm²mm²

AWGAWG

0,5–1,50,5–1,520–1420–142

TerminalsTerminal screwsScrew driverTightening torque

PozidrivNm

M2,5Pz10,6–0,8

Coil AC-operatedOperation Range in multiples of control voltage UsPower consumption inrush hold

VAVA

0,85–1,194

Main Contacts (cULus) Typ K0-05D..K0W05D..

Rated operational current “General Use”

Rated operational power of three-phase 110-120Vmotors at 60Hz (3ph) 200-208V 220-240V 277V

Rated operational power of AC motors 110-120Vat 60Hz (1ph) 200-208V 220-240V

Fuse / Short-circuit current

Rated voltage

A

hphphphp

hphphp

A/kA

V~

12

½111½

½¾

30/5

300

Auxiliary Contacts (cULus) heavy pilot duty standard pilot duty

ACDC

B300 R300

Micro Contactor K0

Relay-size contactor, smallest in the world.

>3 mm contact clearance acc. to IEC 60335-1 for Safety Applications.

Reversing contactor with mechanical interlock.

New!

Page 2: Micro Contactor K0 - BENEDICT · 2020. 2. 7. · Main contacts Type K0-05D.. K0W05D.. AC1 I e (=I th) open at 40°C AC2, AC3 400V Fuse “Typ1” gL (gG) A A kW A 12 5 2,2 20 Cable

Wiring diagrams

Contactors

K0-05D01 K0-05D10 K0-05D00-40 K0-05D00-22

Reversing Contactors

K0W05D01MC K0W05D10MC

K0W05D..MC (DC)

w w w . b e n e d i c t . a t

Micro Contactor K0

15mm-DIN-rail

K0-05D.. (DC)

Dimensions for Contactors and Reversing Contactors AC and DC operated

A1 A121 1321 13

22 1422 14

1 11 13 33 35 55 5

2 22 24 44 46 66 6

A1 A1

A2 A2A2 A2K1 K1K2 K2