Mica Tape Conductor
Click here to load reader
Transcript of Mica Tape Conductor
7/23/2019 Mica Tape Conductor
http://slidepdf.com/reader/full/mica-tape-conductor 1/1
MATERIAL DATA SHEETASTA MICA TAPE INSULATED
SINGLE CONDUCTORSMDS MT001
Issued: Approved: Released: Replaced by:
Name: T. Trimmel Name: W. Fenz Name: J. Ponweiser Doc.: ---
Date: 2005-04-14 Date: 2005-04-14 Date: 2005-04-14 Date: ---
Technical Characteristics Unit ValueNumber of Single Strands n 1
Bare Width of Single Strand b1 mm ≥ 2
≤ 25 (only Mica tape insulation)
≤ 23 (Enamel + Mica tape insulation)Bare Thickness of Single Strand s1 mm ≥ 1
≤ 8
Ratio Conductor Width / Thickness b1:s1 ≤ 10 : 1
Cross Section A mm² approx. 100 (only Mica tape insulation)
≤ 80 (Enamel + Mica tape insulation)Edge Radius r mm acc. EN 60317-0-2 or on special
request
Material Cu-ETP material no. CW004ACuAg0,10 material no. CW013A Acc.EN1977:1998
Enamel Insulation Enamel Temperature Class 200
Nominal Increase due to Insulation IZ mm 0,13
Insulation Material - Mica Tape
- Mica Tape with Epoxy- Additional inner layer polyester filmpossible
- Enamel and Mica Tape possible
Nominal Increase due to Insulation IZ mm ≥ 0.36
Proof Stress Rp0,2 N/mm² ≤ 180
Other dimensions and designs on request
Mica Tape Insulation Enamel InsulationMica Tape
Copyright © 2005 by ASTA Elektrodraht GmbH & Co. All rights reserved. No part of this publication may be reproduced, storedin or introduced into a retrieval system or other media, in any form or by any means (electronic, mechanical, photocopying, or
otherwise) without the prior written permission of ASTA Elektrodraht GmbH & Co.This brochure contains only general information and statements. Data and values are warranted or guaranteed by the
manufacturer or vendor only, if such warranty or guarantee is expressly agreed upon.Page 1 / 1
b1
b2
s1 s2
IZ/2
b1
b2
s1 s2
IZ/2