mHealth based on NFC Technology –Preliminary results from medium scale proof of concept projects Morak Jürgen1, Schreier Günter1
1Safety & Security Department, AIT Austrian Institute of Technology GmbH
![Page 2: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/2.jpg)
Einführung
Telemonitoring bei chronischen Erkrankungen Einsatz des Mobiltelefons als Patienten-Terminal Near Field Communication (NFC) Technologie
KeepInTouch Datenerfassung mit NFC Geräten Interaktion mit passiven RFID Karten/Tags
Einsatz in Proof of Concept Telemonitoring Projekten ELICARD – Herzschwäche Telemonitoring System des Krankenhaus der
Elisabethinen Linz DiabMemory – Telemonitoring Komponente des Gesundheitsdialoges Diabetes
Mellitus der Versicherung für Eisenbahn und Bergbau (VAEB)
205.07.2012
![Page 3: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/3.jpg)
Closed Loop Telemonitoring
305.07.2012
![Page 4: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/4.jpg)
Wohlbefinden,Schmerzen, Medikamente…
4
mHealth – Mobiltelefon als Patienten-Terminal
Kollmann A, Riedl M, Kastner P, Schreier G, Ludvik B. Feasibility of a Mobile Phone–Based Data Service for Functional Insulin Treatment of Type 1 Diabetes Mellitus Patients. J Med Internet Res 2007;9(5):e36, URL: www.jmir.org/2007/5/e36/
Scherr, et al, Effect of Home-Based Telemonitoring Using Mobile Phone Technology on the Outcome of Heart Failure Patients After an Episode of Acute Decompensation: Randomized Controlled Trial J Med Internet Res 2009, | vol. 11 | iss. 3 | e34 | p.1 http://www.jmir.org/2009/3/e34/
Morak J, Schindler K, Goerzer E, Kastner P, Toplak H, Ludvik B, Schreier G. A pilot study of mobile phone-based therapy forobese patients. J Telemed Telecare. 2008;14(3):147-9.
Application Hosting Device
Manuell via Tasten
Subjektive Parameter
Automatisch via Bluetooth
05.07.2012
Objektive Parameter
Anmeldedaten BenutzernamePasswort
![Page 5: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/5.jpg)
Near Field Communication vs. Bluetooth
Eigenschaften NFC Bluetooth
Frequenzbereich 13,56 MHz 2,4 GHz bzw. 5 GHz (V 3.0 +HS)
Datenrate 424 kBit/s 24 MBit/s (V 3.0 + HS)Reichweite < 10 cm 100 m (class1)Setup Dauer < 0,1 s > 5 s
Konfiguration/Auswahl automatisch manuell
Topologie peer 2 peer (nur 2 Teilnehmer) Netz (bis zu 255 Teilnehmer)Kompatibel zu RFID ISO14443, ISO15693 nein
5
NFC erlaubt intuitive Bedienung durch „in-die-Nähe-Bringen“ einfach anzuwenden und zu erlernen Plug‘n Play ohne Konfiguration Anwender ist aktiv in den Datenerfassungsprozess involviert
05.07.2012
![Page 6: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/6.jpg)
KeepInTouch (KIT) – NFC basierte Datenerfassung I
NFC Mobiltelefon dient als Patienten Terminal J2ME Software Applikation Erfassung, Speicherung und Synchronisation Empfang und Anzeige von Feedback-Nachrichten
Berührungs-basierte Datenerfassung Messgeräte mit NFC ausgestattet Multi-User Gerät (Blutdruckmessgerät, Waage, usw.)
liefert immer nur einen Messwert Single-User Gerät (Blutzuckermessgerät, usw.) speichert
und liefert mehrere Messwerte
6
UA-767Plus NFC (entwickelt mit A&D Medical und als MP zugelassen)
2G/3G
05.07.2012
![Page 7: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/7.jpg)
KeepInTouch (KIT) – NFC basierte Datenerfassung II
NFC basierte Benutzer Anmeldung ISO14443 Smartcard Technologie ID Karte Automatischer Programmstart durch Berührung Token-basierte Identifikation und Authentifizierung
User Interface mittels smarten Symbolen Beantworten von Fragen durch Berühren von Symbolen Angabe von Wohlbefinden, Schmerzen oder
Atmungsprobleme Dokumentation von körperlicher Bewegung durch Berühren
von Symbolen oder mit RFID Tags versehene Objekte
705.07.2012
![Page 8: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/8.jpg)
ELICARD
Telemonitoring-System der Elisabethinen Linz (seit März 2009)
Herzinsuffizienz (HI) und Pulmonaler Arterieller Hypertonie (PAH)
Ausstattung: Koffer mit KIT-fähigem Mobiltelefon (Nokia 6131), Blutdruckmessgerät, Körperwaage, ID-Karte, KIT-Dialogbuch (Wohlbefinden, Medikation), [Pulsoximeter] (PAH-Patienten)
Demonstration im Krankenhaus, danach Zustellung der Geräte via Post
Erfassung aller Daten an jedem Tag (HI) bzw. an jedem 2. Tag (PAH) in einem streng definiertem Ablauf
805.07.2012
![Page 9: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/9.jpg)
DiabMemory
Telemonitoring-Komponente des GesundheitsdialogesDiabetes Mellitus der VAEB (seit Mai 2010)
Ausstattung von Patienten vor Ort (Kuranstalt): KIT-fähiges Mobiltelefon und Blutzuckermessgerät, ID Karte und Dialogbuch (Wohlbefinden, Aktivität, Intensität), [Blutdruckmessgerät, Waage]
Blutzuckermessung (T1DM: mind. 3x täglich, T2DM: mind. 3x an einem Tag pro Woche)manuelle Eingabe von Insulin-und Broteinheiten, Freitext
Verwendung von 3 unterschiedlichen NFC Mobiltelefonen (Nokia 6212, Samsung S5230, Nokia 701)
905.07.2012
![Page 10: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/10.jpg)
Statistik (Stand Q1/2012)
10
ELICARD DiabMemory gesamtHI PAH T1DM T2DM
Parameter gesamt Median [IQR] gesamt Median [IQR] gesamt Median [IQR] gesamt Median [IQR]
Patienten (w) [n] 23 (6) 17 (11) 18 (5) 211(41) 269(63)
Alter [Jahre] 74,8 [64,6-78,2] 68,3 [62,3-72,3] 49,5 [40,5-56,7] 59,7 [53,2-64,9]
Kum. Monitoringdauer [Tage] 13602 716 [250-1016] 6482 495 [259-534] 5605 274 [101-514] 64415 298 [140-467] 90104
Übertragungen [n] 22057 1078 [329-1590] 4568 313 [125-387] 19056 732 [234-1776] 84997 268 [121-458] 130678
übertragene Datenobjekte [n] 72201 19374 22726 906 [267-2192] 161696 572 [239-1073] 275997
Blutzucker [%] 82,2 56,2
Körpergewicht [%] 15,12 11,56 1,4 4,9
Blutdruck [%] 15,43 12,02 6,8 18,5
Wohlbefinden [%] 15,43 12,02 4,0 9,1
Aktivität (+Intensität) [%] 5,5 11,3
Medikation [%] 54,02 38,45
O2 Sättigung [%] 12,02
Atmungsprobleme [%] 12,02Laboruntersuchung durchgeführt? [%] 0,98
Neues Rezept? [%] 0,95
Freitext-Kommentare [n] 308 2,5 [1,3-12,5] 2239 1 [0-8,5]
Adhärenz [%] 81,9 82,2 90,2 86,5
05.07.2012
![Page 11: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/11.jpg)
Diskussion
Usability vs. Security
Deployment & Wartung
Verfügbarkeit
SW - Installation und Update
1105.07.2012
![Page 12: mHealth based on NFC Technology – Preliminary results from ...telemed-berlin.de/telemed/2012/vortrag/vortrag_morak254_467.pdfmHealth based on NFC Technology – Preliminary results](https://reader035.fdocuments.in/reader035/viewer/2022070618/5e181ee88bdfd42bad01b203/html5/thumbnails/12.jpg)
Zusammenfassung
Neue Form der Gesundheitsversorgung
Ubiquitäre Lösung -> mHealth
Richtiges Setup für machbare Lösung in Routine