Metrology
description
Transcript of Metrology
Slide 1
linear measurement
Linear Measurement :-Non Precision InstrumentsCalipers 1) firm joint callipers (Inside & Outside callipers) 2) spring type callipers (Inside & Outside callipers) 3) Odd leg callipers
2) Trammels
Preicision callipers
Vernier calliper Least Count -0.02 mm 1) Type A 2) type B 3) type CVernier height gauge Vernier depth gauge
2) Micrometers Least Count -0.01Outsdie MircometerInside MicrometerDepth micrometerBench MicrometerDigital micrometerMicrometer with Dial gaugeScrew thead micrometer
Bore guageDial Bore gaugeHemipherical bore gauge
Telescopic gauge
Slip Gauge
Limit gaugePlug gaugeProgressive Plug gaugeRing gaugeSnap gaugeProgressive snap gaugeCalibration of linear measurement
Calibration of vernier calliperA)Hardness Test on working facesB) Flatness and squareness of beamC) Flatness of the working surfaceD) Parallelism of the measuring JawE) Accuracy
Calibration of micrometerZero error TestBacklash errorBanding TestParallelism error testFlatness error test
VERNIER DEPTH GAUGE
OUTSIDE MICROMETER
INSIDE MICROMETER
DEPTH MICROMETER
BENCH MICROMETER
DIGITAL MICROMETER
MICROMETER WITH DIAL GAUGE
SCREW THREAD MICROMETER
DIAL BORE GAUGE
HEMISPERICAL BORE GAUGE
TELESCOPIC GAUGE
TELESCOPIC BORE GAUGE
APPLICATION OF TELESCOPIC BORE GAUGE
SLIP GAUGE
WRINGING OF SLIP GAUGE
SLIP GAUGES
LIMIT GAUGEPLUG DOUBLE ENDEDGO AND NOGO GUAGE
PROGRESSIVE PLUG GAUGE
TAPER PLUG GAUGE
RING GAUGE
RING GAUGE
DOUBLE ENEDED SNAP GAUGE
PROGRESSIVE SNAP GAUGE
ADJUSTABLE SNAP GAUGEAngular measurementAngular Measurement :-A)ProtractorsVernier Bevel ProtactorsUniversal bevel protactorOptical bevel protactorsb) Sine BarsSine CentersAngle GaugesSpirit LevelClinometerVernier clinometerMicromter clinometerG) Auto ClinometerH) Angle Dekkor
APPLICATION OF SLIP GAUGES
Advantages of sine Bar:-
It is used for accurate and precise angular measurementIt is available easilyIts is cheap
Disadvantage:-
1)The application is limited for a fixed centre distance between two plugs or rollers.2) It is difficult to handle and position the slip gaugesIf the angle exceeds 45 degree sine bar are impracticable and inaccurate.3) Large angular error may result due to slight error in sine barSOURCES OF ERROR IN SINE BAR :-
Error in distance between rollersError in slip gauges combination used for angle settingError in equality of size of rollers and cylinders accuracy in the form of rollers.Error in parallelism of roller axes with each other.Error in flatness of the upper surface of the bar
SINE CENTRE
ANGLE GAUGES
SPIRIT LEVEL
VERNIER CLINOMETER
MICROMETER CLINOMETER
AUTO COLLIMATOR