METALWORKS LINEAR MASTER SHEET SHEET 1 - PARTS & … · 2017. 12. 14. · MASTER SHEET 5/2/17 MAP....
Transcript of METALWORKS LINEAR MASTER SHEET SHEET 1 - PARTS & … · 2017. 12. 14. · MASTER SHEET 5/2/17 MAP....
-
2" THROUGH 12" LINEAR PLANKS
8159
2" SPLICE
PLATE
5495
4" SPLICE PLATE
7163
6" SPLICE PLATE
5496
8" SPLICE
PLATE
8138
2" END CAP
8139
10" END CAP
5581
4" END CAP
7162
6" END CAP
5582
8" END CAP
5583
12" END CAP
RC2
6459BL OR QSUTC
RIGID ATTACHMENT
CLIP (RAC)
7237
CUT PLANK SUPORT
BRACKET
5574
CARRIER MOLDING
XTAC 8161
PRESSURE
SPRING
BACG90
7800
7/8" HEMMED ANGLE MOLDING
5494
CONTRAST FILLER STRIP
GENERAL PRODUCT
OVERVIEW
STRING LINE
PLACEMENT
MAIN BEAM CARRIER
ATTACHMENT
PERIMETER 1
PERIMETER 2
CUT PLANK SUPPORT
BRACKET 1
CUT PLANK SUPPORT
BRACKET 2
7177
MAIN CARRIER
96"
2"
96"96" 96"
96"96"
4"
6"8" 10" 12"
7177
XL89454' DRYWALL GRIDCROSS TEE
5574
7177
5574 7237
7177
7237
8120 - UNPERFORATED
8121 - MICROPERFORATED
(NOT PICTURED)
5490 - UNPERFORATED
5492 - MICROPERFORATED
(NOT PICTURED)
7160 - UNPERFORATED
7161 - MICROPERFORATED
(NOT PICTURED)
5491 - UNPERFORATED
5493 - MICROPERFORATED
(NOT PICTURED)
8122 - UNPERFORATED
8123 - MICROPERFORATED
(NOT PICTURED)
5570 - UNPERFORATED
5571 - MICROPERFORATED
(NOT PICTURED)
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SOLUTIONS * Lancaster, PA * Phone: 877-ARMSTRONG
METALWORKS LINEAR
MASTER SHEET
5/2/17
MAP
.
1' 0" = 1' 0"
SHEET 1 - PARTS & ACCESSORIES
. .
.
.
.
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Requirements) that may be
applicable for a particular installation.
Armstrong Ceiling Solutions does not warrant, and assumes no liability for the accuracy or
completeness of the drawings for a particular installation or their fitness for a particular
purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
R
-
SPLICE INSTALLATION
PANEL INSTALLATION
PERIMETER SPRINGS
LAST PERIMETER ROW
LAST FULL PLANK WIDTH ROW SPLICES
LAST FULL PLANK WIDTH ROW
PANEL END CAPS
FILLER STRIP INSTALLATION
FACETED
INSTALLS
WALL AND CEILINGS TO
WALL INSTALLATION
ACCESS DOOR
COMPRESSION POST
INSTALLATION
2.9
SPLICE PLATE
LINEAR PLANK
SPLICE PLATE
81617177
5574
5494
RC2
6459BL OR QSUTC
7177
8161
RC2
7177
END CAPS
8161
5574
7177
BACG90
7177
BACG90
5574
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SOLUTIONS * Lancaster, PA * Phone: 877-ARMSTRONG
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Requirements) that may be
applicable for a particular installation.
Armstrong Ceiling Solutions does not warrant, and assumes no liability for the accuracy or
completeness of the drawings for a particular installation or their fitness for a particular
purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
R
METALWORKS LINEAR
MASTER SHEET
5/2/17
MAP
.
6" = 1' 0"
SHEET 2 - INSTALLATION
. .
.
.
.
-
GENERAL EXTERIOR PANEL SPLICE
10" AND 12" EXTERIOR PANEL SPLICE
SEISMIC BORDERS
AXIOM INTEGRATION
LIGHTING INTEGRATION
INTERIOR AND SEISMIC
CLASS 90 8" 10" 12"
CLASS 90 2" 4" 6"
CLASS 30 2" 4" 6" 8"
GRID LAYOUTS
AXIOM
PMHDC
ADJUSTABLE TRIM CLIP
7177
LINEAR PLANK
PERIMETER
XTAC
BERC2 8161BERC2
7177
8161 5574
7177
SPLICEPLATES
LINEARPLANKS
DRYWALL GRIDCROSS TEETECHZONE YOKE
21316"
4"
214"FINELITE (HP-2) - RECESSEDLINEAR LIGHT FIXTURE W/O FLANGE(FIXTURE MUST BE INDEPENDENTLYSUSPENDED FROM STRUCTURE)
314"
4" LINEAR PANEL
SELF TAPPING SCREWSUPPLIED BY INSTALLER
5574 MOLDING34" 4"
USE ARMSTRONG PRELUDEXL HEAVY DUTY MAIN BEAM (SUPPLIEDBY INSTALLER) TO CREATEBRACING BETWEEN CEILINGS
ARMSTRONG DW90C TO ATTACHMAIN BEAMS (SUPPLIED BY INSTALLER)FIELD TRIMMING WILL BE REQ'D
LIGHTING INTERGRATION FINELITE HP-2 RECESSED
LINEAR CARRIER
#12 HANGER WIRESUPPLIED BY INSTALLER
4" 34"5574 MOLDING
SELF TAPPING SCREW(SUPPLIED BY INSTALLER)
4" LINEAR PANEL 314"
FINELITE (HP-4) - RECESSEDLINEAR LIGHT FIXTURE W/O FLANGE(FIXTURE MUST BE INDEPENDENTLYSUSPENDED FROM STRUCTURE)
4"
4"
21316"
USE ARMSTRONG PRELUDEXL HEAVY DUTY MAIN BEAM(SUPPLIED BY INSTALLER) TO CREATEBRACING BETWEEN CEILINGS
ARMSTRONG DW90C TO ATTACHMAIN BEAMS (SUPPLIED BY INSTALLER)FIELD TRIMMING WILL BE REQ'D
LIGHTING INTERGRATION FINELITE HP-4 RECESSED SK3A
LINEAR CARRIER
#12 HANGER WIRESUPPLIED BY INSTALLER
8" 34"
LINEAR CARRIER
SELF TAPPING SCREW(SUPPLIED BY INSTALLER)
#12 HANGER WIRESUPPLIED BY INSTALLER
FINELITE (HP-4) - RECESSEDLINEAR LIGHT FIXTURE W/ FLANGE(FIXTURE MUST BE INDEPENDENTLYSUSPENDED FROM STRUCTURE)
FIELD CUT FIXTURE INTOCENTER OF METALWORKSLINEAR PANEL (DETAIL DEPENDS ONSIZE OF PANEL AND SIZE OF FIXTURE)
412"
4"
4"
8" LINEAR PANEL
21316"
USE ARMSTRONG PRELUDEXL HEAVY DUTY MAIN BEAM(SUPPLIED BY INSTALLER) TO CREATEBRACING BETWEEN CEILINGS
ARMSTRONG DW90C TO ATTACHMAIN BEAMS (SUPPLIED BY INSTALLER)FIELD TRIMMING WILL BE REQ'D
5574 MOLDING
LIGHTING INTERGRATION FINELITE HP-4 RECESSED SK3B
4" 34"
SELF TAPPING SCREWSUPPLIED BY INSTALLER
4" LINEAR PANEL 314"
5574 MOLDING
41116"
LEDALITE TRUGROOVELINEAR RECESSEDLIGHT FIXTURE (39S8F10QSI)(FIXTURE MUST BEINDEPENDENTLY SUSPENDEDFROM STRUCTURE)
334"
21316"
USE ARMSTRONG PRELUDEXL HEAVY DUTY MAIN BEAM(SUPPLIED BY INSTALLER) TO CREATEBRACING BETWEEN CEILINGS
ARMSTRONG DW90C TO ATTACHMAIN BEAMS (SUPPLIED BY INSTALLER)FIELD TRIMMING WILL BE REQ'D
5574MOLDING
LIGHTING INTERGRATION LEDALITE TRUGROOVE LINEAR RECESSED DIRECT ASYMMETRIC SK3A
LINEAR CARRIER
#12 HANGER WIRESUPPLIED BY INSTALLER
8" 34"5574 MOLDING
SELF TAPPING SCREWSUPPLIED BY INSTALLER
8" LINEAR PANEL
41116"
FIELD CUT FIXTURE INTOCENTER OF METALWORKSLINEAR PANEL (DETAIL DEPENDS ONSIZE OF PANEL AND SIZE OF FIXTURE)
LEDALITE TRUGROOVELINEAR RECESSEDLIGHT FIXTURE (39S8F10QSI)(FIXTURE MUST BEINDEPENDENTLY SUSPENDEDFROM STRUCTURE)
334"
21316"
USE ARMSTRONG PRELUDEXL HEAVY DUTY MAIN BEAM(SUPPLIED BY INSTALLER) TO CREATEBRACING BETWEEN CEILINGS
ARMSTRONG DW90C TO ATTACHMAIN BEAMS (SUPPLIED BY INSTALLER)FIELD TRIMMING WILL BE REQ'D
LIGHTING INTERGRATION LEDALITE TRUGROOVE LINEAR RECESSED DIRECT ASYMMETRIC SK3B
LINEAR CARRIER
#12 HANGER WIRESUPPLIED BY INSTALLER
WALL
SELF TAPPING SCREWSUPPLIED BY INSTALLER
5574 CARRIER MOLDING
7177 LINEAR CARRIER
LINEAR PANELLINEAR PANELLINEAR CARRIER
METALWORKS LINEAR TRANSITIONING TO WALL
#12 HANGER WIRESUPPLIED BY INSTALLER
8" 34"
SELF TAPPING SCREWSUPPLIED BY INSTALLER
4"
5 516"
478"
FIELD CUT FIXTURE INTOCENTER OF METALWORKSLINEAR PANEL (DETAIL DEPENDS ONSIZE OF PANEL AND SIZE OF FIXTURE)
SEEM 4 LINEAR LIGHTFIXTURE W/ FLANGE(FIXTURE MUST BEINDEPENDENTLY SUSPENDEDFROM STRUCTURE)
8" LINEAR PANEL
21316"
5574 MOLDING
USE ARMSTRONG PRELUDEXL HEAVY DUTY MAIN BEAM(SUPPLIED BY INSTALLER) TO CREATEBRACING BETWEEN CEILINGS
ARMSTRONG DW90C TO ATTACHMAIN BEAMS (SUPPLIED BY INSTALLER)FIELD TRIMMING WILL BE REQ'D
LIGHTING INTERGRATION SEEM 4 SK3B
LINEAR CARRIER
#12 HANGER WIRESUPPLIED BY INSTALLER
4" 34"5574 MOLDING
SELF TAPPING SCREWSUPPLIED BY INSTALLER
4" LINEAR PANEL 314"5574 MOLDING
478"
SEEM 4 LINEAR LIGHTFIXTURE W/O FLANGE(FIXTURE MUST BEINDEPENDENTLY SUSPENDEDFROM STRUCTURE)
4"
21316"
USE ARMSTRONG PRELUDEXL HEAVY DUTY MAIN BEAM(SUPPLIED BY INSTALLER) TO CREATEBRACING BETWEEN CEILINGS
ARMSTRONG DW90C TO ATTACHMAIN BEAMS (SUPPLIED BY INSTALLER)FIELD TRIMMING WILL BE REQ'D
LIGHTING INTERGRATION SEEM 4 SK3A
LINEAR CARRIER
#12 HANGER WIRESUPPLIED BY INSTALLER
DATE:
DRAWN BY:
DWG. NO.
PROJECT NAME:
SCALE:
CHK BY:
DESC.:
REV:
DATE:
ARMSTRONG CEILING SOLUTIONS * Lancaster, PA * Phone: 877-ARMSTRONG
Armstrong is not licensed to provide professional architecture or engineering design services.
These drawings show typical conditions in which the Armstrong product depicted is installed.
They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Requirements) that may be
applicable for a particular installation.
Armstrong Ceiling Solutions does not warrant, and assumes no liability for the accuracy or
completeness of the drawings for a particular installation or their fitness for a particular
purpose.
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
R
METALWORKS LINEAR
MASTER SHEET
5/2/17
MAP
.
1' 0" = 1' 0"
SHEET 3 - INSTALLATION
. .
.
.
.
MetalWorks Linear Master Sheet-SHEET 1MetalWorks Linear Master Sheet-SHEET 2Sheets and ViewsSHEET 2
MetalWorks Linear Master Sheet-SHEET 3MetalWorks Linear Master Sheet-SHEET 3.pdfSheets and ViewsSHEET 3