« METAL HOME - Agostini's Limited Catalog 2006.pdf · Agostini Industries Limited Page 1/20 File #...
Transcript of « METAL HOME - Agostini's Limited Catalog 2006.pdf · Agostini Industries Limited Page 1/20 File #...
Agostini Industries Limited Page 1/20
File # Trinidad catalog 2006 a Date 20/11/2006
« METAL HOME »
CATALOG 2006
Oropune 2 – 3 bedroom 962sqf model
Agostini Industries Limited Page 2/20
File # Trinidad catalog 2006 a Date 20/11/2006
Content
1/ Preamble
2/ Technique used
3/ Our proposal
4/ Models
4.1 ) 1 bedroom house
565 Not developed in Trinidad
4.2 ) 2 bedroom house
714 Floor plan Facades Sections Architectural specifications
4.3 ) 3 bedroom house
913 Floor plan Facades Sections Architectural specifications
962 Floor plan
Facades Sections Architectural specifications
1011 Floor plan
Facades Sections Architectural specifications
1194 Floor plan
Facades Sections
Agostini Industries Limited Page 3/20
File # Trinidad catalog 2006 a Date 20/11/2006
Architectural specifications
5/ Our offer
5.1) Technical (not applicable at this time)
5.2) Administration 3.21 Contract (to be negotiated at point of sale)
5.3) Financing 3.31 Price list with options (565 to 1011)
Agostini Industries Limited Page 4/20
File # Trinidad catalog 2006 a Date 20/11/2006
1/ Preamble The proposed house is adapted for any region from tropical to temperate countries and can withstand earthquakes and hurricanes. The shape of the roof is issued from traditional houses and can be adapted to any one as needed.
The concept introduces light elements that can be manipulated and erected by one, two or three people without any heavy machinery needed.
Material used for structural components have eliminated wood to allow this house to be termite proof and resistant to mould and moisture if well ventilated.
2/ Technique used
2.1 Structure The structure is composed of galvanised cold-formed steel for the walls and trusses. All profiles are manufactured by roll forming and assembling done with galvanised bolts and self-tapping screws. Only 7 preferred profiles are used as follow:
- Omega profiles o Large ones of 80 x 77 x 1.25mm with 15mm lips for:
§ Stud for external wall § Top and bottom of trusses
o Small ones of 80 x 52 x 1.25mm with 15mm lips for: § Purling
- U profiles: o Of 78 x 43 x 1.25mm for:
§ Top and bottom of wall panels § Top and bottom of large openings for windows and doors.
o Of 52 x 43 x 1.25mm for: § Eave purling § Ridging § Ventilation bash-bord.
o Of 150 x 35 x 1.25mm for: § Bash board.
- Small C profiles of 47 x 47 x1.25mm for: § Vertical and oblique beams inside trusses
- Strap profiles of 160 x1.25mm for: § Horizontal and vertical cross bracing. § Note this strap of 160mm is use also for the fabrication of small C
and U. All the profiles are assembled - In factory (panels and trusses) - On site to erect the structure - With 10mm SI bolts and 4mm self-tapping screws.
Agostini Industries Limited Page 5/20
File # Trinidad catalog 2006 a Date 20/11/2006
- The gypsum board provider also provides the ceiling and eave profiles in galvanised 0.5mm thickness.
For the porch, normal RHS profiles are welded together and bolted to wall panels. For the basic drawings everything is subdivided into multiples of 305mm and is adapted to receive American products with metric measurements.
Panel assembly on special jig
Truss details
Agostini Industries Limited Page 6/20
File # Trinidad catalog 2006 a Date 20/11/2006
2.2 External walls
2.21 Concrete tiles The external wall is composed of prefabricated concrete tiles of 609 x 609 x 38.5mm
bolted with 4 x 8mm bolts onto the vertical Omega structure. Polypropylene fibres and a 5mm frame reinforce the concrete, which supports the metallic inserts for the bolts. Each tile has a 1mm gap and end treated to allow a 9mm joint.
Wall test at Macoya factory (Trinidad 2001)
2.22 Facade finish Water proofing and finish of the external wall are done by a process as follows:
- After 9mm backer rod, joint treatment with a flexible fibrous product provided by PRB (France).
- Total surfacing with the same product as above. - White primer. - Surface finishing by the painter at the end of construction with special flexible and
waterproofing plaster chosen from the PRB collection.
Agostini Industries Limited Page 7/20
File # Trinidad catalog 2006 a Date 20/11/2006
Backer rod in place.
2.3 Openings
2.31 Windows and vents We propose external swinging aluminium window. It is with a single transparent glass.
Aluminium frame with burglar-proofing (Natural and painted)
The house ventilation is done by mechanical ventilation with one exhaust fan in attic and one automatic air control entrance of 30m3/h for each dry room (Living and bedrooms).
Attic ventilation is done by 2 painted metallic grids.
Vent inside prefabricated gable
Agostini Industries Limited Page 8/20
File # Trinidad catalog 2006 a Date 20/11/2006
2.32 Doors The entrance doors are 915 x 2040 x 35mm wooden with an external protection (steel
sheeting). Doors are equipped with 2 x 40mm hinges and one American lock.
2.33 Frames All external and internal frames are aluminium. These are directly fastened by self-
tapping screws on the vertical studs in the panel for the entrance doors. The external window frames are equipped with burglar proofing in 12mm horizontal
squares and 10mm vertical diam bars. This security protection allows the finishing of the house without too many thefts of material.
Burglar-proofing, panel bracing and window frames.
2.4 Roofing The roofing consists of corrugated or gable « aluzinc » lacquered sheets. Fastening is done with self-tapping screws with gasket as follows: - Eaves and ridging every 250mm (maximum) - Other places every 500mm maximum on the purling.
Flashing done with the same type of sheeting covering all ridging and hips.
Agostini Industries Limited Page 9/20
File # Trinidad catalog 2006 a Date 20/11/2006
3/ Our proposal
For export, the house kit proposed shall be erected on a concrete base which includes: - Foundations - All the service connections for drainage, potable water and electricity. - The access for the 40” container. The container will be used as site storage during
the erection for the security of the imported material. When the house is closed and secured, remaining items can be transferred to the house and the container returned.
- One electricity site supply for hand tools (12mm Percussion drills and screw drivers).
The Kit includes the following parts:
3.1/ English assembly manual 3.2/ Assembly drawings 3.3/ Structural components Wall panels with frames and bracings (about 12/13 panels for 100m2 Gross area
house). Concrete tiles with bolts and washers. Hilti 10 x 65mm anchorage as needed. Trusses, half and cut trusses. (Note: The maximum height for truss is 2.59m) All Omega and U purling are in 5.80m lengths in galvanised steel. Supply of covering sheeting. All components for bash board and cable connection (if required). Two vents for the hip roof. All assembly screws and bolts. Door (s) with hinges and lock as described above. Column(s) and beams for the porch structure in RHS already cut and ready to be
welded on site.
Agostini Industries Limited Page 10/20
File # Trinidad catalog 2006 a Date 20/11/2006
3.4/ Container loading Container loading is done to: - Balance the load inside - Provide availability of component in the right order for the erection.
Typical load for 1011 house in 40” container
Erection under rain (Structure complete, tile and bash board under progress).
Agostini Industries Limited Page 11/20
File # Trinidad catalog 2006 a Date 20/11/2006
3.4/ Finishing materials a) Outside
Gypsum board (Green quality) for ceiling and eaves Cartridge(s) of silicone for the panel’s peripheral joint b) Inside Ceiling furring directly fixed to the bottom of trusses with screw framers. Partition studs and channels for 89mm finish partition. Gypsum board of “green quality” 1.22 x 2.44 x 13mm for ceiling, partition and
external walls. For each bathroom 2 boards of 1.22 x 2.44 x 13mm concrete fibre. Map and strap for joint treatment.
3.5/ Technical assistance
For the construction of the first house we can provide the assistance of one technician under agreed conditions. 4/ Not included in our kit for complete house construction.
All materials for the realisation of the reinforced concrete base. With the great difference between local regulations and practice we cannot provide the
following: - Internal joinery (doors and frames, hinges, locks and skirting) Without pre study. - Electricity (Boxes, sockets, switches and cables) - Plumbing (Appliances, fixtures and pipes) - Floor and wall tiling - Primer and paint
5/ Problems to be treated as local adaptation.
Internal distribution.
Direct choice of house model in our catalogue or special internal drawing as requested.
Agostini Industries Limited Page 12/20
File # Trinidad catalog 2006 a Date 20/11/2006
6/Special requirements Outside protection by shutters. Different eaves (0, 600 or 1200mm) Gutter.
Technical adaptations. All of these shall be defined with your technician or « bureau of control ».
Structure grounding. (in Trinidad one common grounding is requested for sockets, neutral and metallic structures). Other administrative questions,
Local technical process agreement (this process is considered as a tradition by US regulations as "cold formed steel structure")
Permission for land development and approval from Planning commission or
any other ministry Site insurances and global covering of the construction. We provide material
liability defect only.
Finished house ready for hand over to client.
Agostini Industries Limited Page 13/20
File # Trinidad catalog 2006 a Date 20/11/2006
4/ Models Model chart
Agostini Industries Limited Page 14/20
File # Trinidad catalog 2006 a Date 20/11/2006
4.1 ) 1 bedroom house
565 Floor plan Facades This house is not developed in Trinidad and Tobago
Agostini Industries Limited Page 15/20
File # Trinidad catalog 2006 a Date 20/11/2006
4.2 ) 2 bedroom house
714 Floor plan Facades Sections Architectural specifications
Agostini Industries Ltd. Architectural specificationsmodel 714 , 2 bedroom unit
Page 1/2
Type of unit -Utilisation area 654 sqf or 60.76 sqm Actual gross area 714 sqf or 66.38 sqmDescription Ground floor
Porch 80 sqf or 7.44 sqm Bedroom 2 129 sqf or 11.96 sqmKitchen 81 sqf or 7.52 sqm
Living and entrance 184 sqf or 17.14 sqmToilet 52 sqf or 4.80 sqm
Master bedroom 128 sqf or 11.90 sqm
Room clearance -Outside dimensions -Structure Basement
Elevation
Roof
Walls and external finishes -
Internal finishes of external walls
Partitions -Windows -Glazing -Burglar proofing -
Door External -
Internal -
Roof -Attic vent.
Eaves -
Ceiling -Floor finishing -
Kitchen sink -
Kitchen cupboard -Bedroom cupboard -
Electrical -
Plumbing -
Hip roof with corrugated aluzinc 26G roofing fixed with screws
One 42"x 20" stainless steel single sink & drainboard on wooden cupboard
110 V Lights and plugs 220 V with switch for WH and Stove
Eaves 600mm wide on the perimeter of the house (guttering not included)
Natural longitudinal attic ventilation with 2 triangular vents
Hot and cold water for kitchen, laundry & toilet 2, cold water for Toilet 1. Potable water distrbution with PER piping and PVC for drainage.
Clear plain glass
12"x12" Ceramic tiles 13mm gypsum board - green label inside 1F, porch and eaves
Cold formed steel Omega and track assembled with self trade screws
Aluminium window and framing89mm dry partition with two 13mm gypsum board
Ready to be equippedNot included
13mm gypsum board - green label Concrete fibre sheet on shower enclosure
810mm x 2040mm Hollow core (710mm for Toilet) inside aluminium frames
910mm x 2040mm Solid pitch pine protected with meta sheeting inside aluminium frame
Fixed solid MS profiles on windows only
Cold formed steel panels with Omega profil and bracing with strap 160mm assembled by bolts and nuts
7.560m x 8.780m
Concrete prefabricated tiles fixed by bolts to the structure with special joint treatment and wall finish by PRB complex.
One level Single family house
2.45m
Masonry with 150mm concrete blocks and slab on grade
File # c: A- SP 714 - Architectural specifications - Last update 20/11/2006
Agostini Industries Ltd. Architectural specificationsmodel 714 , 2 bedroom unit
Page 2/2
Mechanical ventilation -
Water heater -
Foundation -
Septic tank -Adaptation to the land -Drains -Site preparation -Connections
TnTEC -WASA -
Exhaut fan in the attic and suction devices in Kitchen (120m3/h) and Toilets and Laundry (30m3/h). Air entrance of 30m3/h in Bedroom and Living
Included - Normal type for flat land and reasonable land load capacity
100 litres (26 Gallons) as option in the cupboard bedroom n°2
Ready to receive the external 1/2" pipe supply from WASAReady to receive the external cable from TnTEC
Not includedNot includedNot includedNot included
File # c: A- SP 714 - Architectural specifications - Last update 20/11/2006
Agostini Industries Limited Page 16/20
File # Trinidad catalog 2006 a Date 20/11/2006
4.3 ) 3 bedroom house
913 Floor plan Facades Sections Architectural specifications
962 Floor plan
Facades Sections Architectural specifications
1011 Floor plan
Facades Sections Architectural specifications
1194 Floor plan
Facades Sections Architectural specifications
Agostini Industries Limited Page 17/20
File # Trinidad catalog 2006 a Date 20/11/2006
4.3.1) 913 Floor plan Facades Sections Architectural specifications
Agostini Industries Ltd. Architectural specificationsmodel 913, 3 bedroom unit
Page 1/2
Type of unit -Utilisation area 838 sqf or 77.81 sqm Actual gross area 913 sqf or 84.82 sqmDescription Ground floor
Porch 80 sqf or 7.44 sqm Bedroom 2 127 sqf or 11.84 sqmKitchen 88 sqf or 8.19 sqm Bedroom 3 111 sqf or 10.35 sqm
Living and entrance 233 sqf or 21.61 sqmBathroom 52 sqf or 4.80 sqm
Master bedroom 146 sqf or 13.58 sqm
Room clearance -Outside dimensions -Structure Basement
Elevation
Roof
Walls and external finishes -
Internal finishes of external walls
Partitions -Windows -Glazing -Burglar proofing -
Door External -
Internal -
Roof -Attic vent.
Eaves -
Ceiling -Floor finishing -
Kitchen sink -
Kitchen cupboard -Bedroom cupboard -
Electrical -
Plumbing -
Hip roof with corrugated aluzinc 26G roofing fixed with screws
One 42"x 20" stainless steel single sink & drainboard on wooden cupboard
110 V Lights and plugs 220 V with switch for WH and Stove
Eaves 600mm wide on the perimeter of the house (guttering not included)
Natural longitudinal attic ventilation with 2 triangular vents
Hot and cold water for kitchen, laundry & toilet 2, cold water for Toilet 1. Potable water distrbution with PER piping and PVC for drainage.
Clear plain glass
12"x12" Ceramic tiles 13mm gypsum board - green label inside 1F, porch and eaves
Cold formed steel Omega and track assembled with self trade screws
Aluminium window and framing89mm dry partition with two 13mm gypsum board
Ready to be equippedNot included
13mm gypsum board - green label Concrete fibre sheet on shower enclosure
810mm x 2040mm Hollow core (710mm for Toilet) inside aluminium frames
910mm x 2040mm Solid pitch pine protected with meta sheeting inside aluminium frame
Fixed solid MS profiles on windows only
Cold formed steel panels with Omega profil and bracing with strap 160mm assembled by bolts and nuts
7.560m x 11.220m
Concrete prefabricated tiles fixed by bolts to the structure with special joint treatment and wall finish by PRB complex.
One level Single family house
2.45m
Masonry with 150mm concrete blocks and slab on grade
File # c: A- SP 913 - Architectural specifications - Last update 21/09/2006
Agostini Industries Ltd. Architectural specificationsmodel 913, 3 bedroom unit
Page 2/2
Mechanical ventilation -
Water heater -
Foundation -
Septic tank -Adaptation to the land -Drains -Site preparation -Connections
TnTEC -WASA -
Exhaut fan in the attic and suction devices in Kitchen (120m3/h) and Toilets and Laundry (30m3/h). Air entrance of 30m3/h in Bedroom and Living
Included - Normal type for flat land and reasonable land load capacity
100 litres (26 Gallons) as option in the cupboard bedroom n°2
Ready to receive the external 1/2" pipe supply from WASAReady to receive the external cable from TnTEC
Not includedNot includedNot includedNot included
File # c: A- SP 913 - Architectural specifications - Last update 21/09/2006
Agostini Industries Limited Page 18/20
File # Trinidad catalog 2006 a Date 20/11/2006
4.3.2) 962 Floor plan
Facades Sections Architectural specifications
Agostini Industries Ltd. Architectural specificationsmodel 962, 3 bedroom unit
Page 1/2
Type of unit -Utilisation area 881 sqf or 81.88 sqm Actual gross area 962 sqf or 89.43 sqmDescription Ground floor
Porch 100 sqf or 9.30 sqm Bedroom 2 98 sqf or 9.14 sqmKitchen 81 sqf or 7.55 sqm Bedroom 3 114 sqf or 10.59 sqm
Living and entrance 265 sqf or 24.58 sqm Bathroom 1 35 sqf or 3.22 sqmBathroom 1 53 sqf or 4.94 sqm
Master bedroom 135 sqf or 12.56 sqm
Room clearance -Outside dimensions -Structure Basement
Elevation
Roof
Walls and external finishes -
Internal finishes of external walls
Partitions -Windows -Glazing -Burglar proofing -
Door External -
Internal -
Roof -Attic vent.
Eaves -
Ceiling -Floor finishing -
Kitchen sink -
Kitchen cupboard -Bedroom cupboard -
Electrical -
Plumbing -
Hip roof with corrugated aluzinc 26G roofing fixed with screws
One 42"x 20" stainless steel single sink & drainboard on wooden cupboard
110 V Lights and plugs 220 V with switch for WH and Stove
Eaves 600mm wide on the perimeter of the house (guttering not included)
Natural longitudinal attic ventilation with 2 triangular vents
Hot and cold water for kitchen, laundry & toilet 2, cold water for Toilet 1. Potable water distrbution with PER piping and PVC for drainage.
Clear plain glass
12"x12" Ceramic tiles 13mm gypsum board - green label inside 1F, porch and eaves
Cold formed steel Omega and track assembled with self trade screws
Aluminium window and framing89mm dry partition with two 13mm gypsum board
Ready to be equippedNot included
13mm gypsum board - green label Concrete fibre sheet on shower enclosure
810mm x 2040mm Hollow core (710mm for Toilet) inside aluminium frames
910mm x 2040mm Solid pitch pine protected with meta sheeting inside aluminium frame
Fixed solid MS profiles on windows only
Cold formed steel panels with Omega profil and bracing with strap 160mm assembled by bolts and nuts
7.560m x 11.830m
Concrete prefabricated tiles fixed by bolts to the structure with special joint treatment and wall finish by PRB complex.
One level Single family house
2.45m
Masonry with 150mm concrete blocks and slab on grade
File # c: A- SP 962 - Architectural specifications - Last update 21/09/2006
Agostini Industries Ltd. Architectural specificationsmodel 962, 3 bedroom unit
Page 2/2
Mechanical ventilation -
Water heater -
Foundation -
Septic tank -Adaptation to the land -Drains -Site preparation -Connections
TnTEC -WASA -
Exhaut fan in the attic and suction devices in Kitchen (120m3/h) and Toilets and Laundry (30m3/h). Air entrance of 30m3/h in Bedroom and Living
Included - Normal type for flat land and reasonable land load capacity
100 litres (26 Gallons) as option in the cupboard bedroom n°2
Ready to receive the external 1/2" pipe supply from WASAReady to receive the external cable from TnTEC
Not includedNot includedNot includedNot included
File # c: A- SP 962 - Architectural specifications - Last update 21/09/2006
Agostini Industries Limited Page 19/20
File # Trinidad catalog 2006 a Date 20/11/2006
4.3.3) 1011 Floor plan
Facades Sections Architectural specifications
Agostini Industries Ltd. Architectural specificationsmodel 1011, 3 bedroom unit
Page 1/2
Type of unit -Utilisation area 924 sqf or 85.86 sqm Actual gross area 1 011 sqf or 94.05 sqmDescription Ground floor
Porch 100 sqf or 9.30 sqm Bedroom 2 109 sqf or 10.10 sqmKitchen 111 sqf or 10.35 sqm Bedroom 3 117 sqf or 10.91 sqm
Living and entrance 258 sqf or 23.93 sqm Bathroom 1 35 sqf or 3.22 sqmBathroom 1 48 sqf or 4.43 sqm WC 12 sqf or 1.13 sqm
Master bedroom 134 sqf or 12.49 sqm
Room clearance -Outside dimensions -Structure Basement
Elevation
Roof
Walls and external finishes -
Internal finishes of external walls
Partitions -Windows -Glazing -Burglar proofing -
Door External -
Internal -
Roof -Attic vent.
Eaves -
Ceiling -Floor finishing -
Kitchen sink -
Kitchen cupboard -Bedroom cupboard -
Electrical -
Plumbing -
Cold formed steel panels with Omega profil and bracing with strap 160mm assembled by bolts and nuts
7.560m x 11.830m
Concrete prefabricated tiles fixed by bolts to the structure with special joint treatment and wall finish by PRB complex.
One level Single family house
2.45m
Masonry with 150mm concrete blocks and slab on grade
Cold formed steel Omega and track assembled with self trade screws
Aluminium window and framing89mm dry partition with two 13mm gypsum board
Ready to be equippedNot included
13mm gypsum board - green label Concrete fibre sheet on shower enclosure
810mm x 2040mm Hollow core (710mm for Toilet and WC) inside aluminium frames
910mm x 2040mm Solid pitch pine protected with meta sheeting inside aluminium frame
Fixed solid MS profiles on windows onlyClear plain glass
12"x12" Ceramic tiles 13mm gypsum board - green label inside 1F, porch and eaves
Hot and cold water for kitchen, laundry & toilet 2, cold water for Toilet 1. Potable water distrbution with PER piping and PVC for drainage.
Hip roof with corrugated aluzinc 26G roofing fixed with screws
One 42"x 20" stainless steel single sink & drainboard on wooden cupboard
110 V Lights and plugs 220 V with switch for WH and Stove
Eaves 600mm wide on the perimeter of the house (guttering not included)
Natural longitudinal attic ventilation with 2 triangular vents
File # c: A- SP 1011 - Architectural specifications - Last update 21/09/2006
Agostini Industries Ltd. Architectural specificationsmodel 1011, 3 bedroom unit
Page 2/2
Mechanical ventilation -
Water heater -
Foundation -
Septic tank -Adaptation to the land -Drains -Site preparation -Connections
TnTEC -WASA - Ready to receive the external 1/2" pipe supply from WASA
Ready to receive the external cable from TnTEC
Not includedNot includedNot includedNot included
Included - Normal type for flat land and reasonable land load capacity
100 litres (26 Gallons) as option in the cupboard bedroom n°2
Exhaut fan in the attic and suction devices in Kitchen (120m3/h) and Toilets and Laundry (30m3/h). Air entrance of 30m3/h in Bedroom and Living
File # c: A- SP 1011 - Architectural specifications - Last update 21/09/2006
Agostini Industries Limited Page 20/20
File # Trinidad catalog 2006 a Date 20/11/2006
4.3.4) 1194 Floor plan
Facades Sections Architectural specifications
Agostini Industries Ltd. Architectural specificationsmodel 1194, 3 bedroom unit
Page 1/2
Type of unit -Utilisation area 1 095 sqf or 101.74 sqm Actual gross area 1 194 sqf or 111.08 sqmDescription Ground floor
Entrance 64 sqf or 5.91 sqm Bedroom 2 138 sqf or 12.79 sqmKitchen 107 sqf or 9.94 sqm Bedroom 3 138 sqf or 12.79 sqm
Living 189 sqf or 17.60 sqm Bathroom 2 34 sqf or 3.15 sqmDining 86 sqf or 8.00 sqm WC 13 sqf or 1.20 sqm
Bathroom 1 52 sqf or 4.79 sqm Corridor 91 sqf or 8.47 sqmMaster bedroom 135 sqf or 12.51 sqm Laundry 49 sqf or 4.59 sqm
Room clearance -Outside dimensions -Structure Basement
Elevation
Roof
Walls and external finishes -
Internal finishes of external walls
Partitions -Windows -Glazing -Burglar proofing -
Door External -
Internal -
Roof -Attic vent.
Eaves -
Ceiling -Floor finishing -
Kitchen sink -
Kitchen cupboard -Bedroom cupboard -
Electrical -
Hip roof with corrugated aluzinc 26G roofing fixed with screws
One 42"x 20" stainless steel single sink & drainboard on wooden cupboard
110 V Lights and plugs 220 V with switch for WH and Stove
Eaves 600mm wide on the perimeter of the house (guttering not included)
Natural longitudinal attic ventilation with 2 triangular vents
Clear plain glass
12"x12" Ceramic tiles 13mm gypsum board - green label inside 1F, porch and eaves
Cold formed steel Omega and track assembled with self trade screws
Aluminium window and framing89mm dry partition with two 13mm gypsum board
Ready to be equippedNot included
13mm gypsum board - green label Concrete fibre sheet on shower enclosure
810mm x 2040mm Hollow core (710mm for Toilet and WC) inside aluminium frames
910mm x 2040mm Solid pitch pine protected with meta sheeting inside aluminium frame
Fixed solid MS profiles on windows only
Cold formed steel panels with Omega profil and bracing with strap 160mm assembled by bolts and nuts
13.250m x 10.610m
Concrete prefabricated tiles fixed by bolts to the structure with special joint treatment and wall finish by PRB complex.
One level Single family house in L
2.45m
Masonry with 150mm concrete blocks and slab on grade
File # c: A- SP 1194 - Architectural specifications - Last update 21/09/2006
Agostini Industries Ltd. Architectural specificationsmodel 1194, 3 bedroom unit
Page 2/2
Plumbing -
Mechanical ventilation -
Water heater -
Foundation -
Septic tank -Adaptation to the land -Drains -Site preparation -Connections
TnTEC -WASA -
Exhaut fan in the attic and suction devices in Kitchen (120m3/h) and Toilets and Laundry (30m3/h). Air entrance of 30m3/h in Bedroom and Living
Included - Normal type for flat land and reasonable land load capacity
100 litres (26 Gallons) as option in the cupboard bedroom n°2
Hot and cold water for kitchen, laundry & toilet 2, cold water for Toilet 1. Potable water distrbution with PER piping and PVC for drainage.
Ready to receive the external 1/2" pipe supply from WASAReady to receive the external cable from TnTEC
Not includedNot includedNot includedNot included
File # c: A- SP 1194 - Architectural specifications - Last update 21/09/2006