MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje...

22
Madrid, 4 th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI A New Technology for Measuring Indoor Environment

Transcript of MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje...

Page 1: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Madrid, 4th October, 2013

Terje Grøntoft, NILU

and

MEMORI partners

MEMORI – A New Technology for Measuring Indoor Environment

Page 2: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Contents 1. MEMORI IAQ measurement technology

A. Dosimeter and portable reader

B. User guide: How, why, when do MEMORI

measurements?

2. MEMORI web pages:

A. MEMORI results presentation

B. MEMORI IAQ risk assessment

C. Mitigation methods

2

Page 3: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

The MEMORI Dosimeter

Two ”glasses” sensitive to air pollutants and climate

3

5 cm

Museum of Cultural

History, Oslo

1. Acidic effects

2. Photo-

oxidation

3 months exposure

Page 4: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Measurement in a portable reader

1. Start measurement (before mounting of dosimeter)

2. Results measurement (after demounting of dosimeter) 4

Page 5: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

How, why, when do

MEMORI measurements How: User guide and Technical manual

are available from web pages.

Why: Assess risk

for degradation

of your objects /

materials.

When: - Possible or

unknown risk. Time of year is important. 5

Page 6: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

6

MEMORI web

pages

Page 7: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Contents

1. Product information

2. User guide

3. Dosimeter results

4. MEMORI results evaluation

5. Air Quality

6. Mitigation

7. Additional information

7

Page 8: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

MEMORI results pages

8

Page 9: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

9

Upload /

Present

results

Page 10: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Presentation in results diagram

10

Page 11: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

11

Fine Arts Royal Academy, San Fernando, Madrid

Example:

Center of Madrid.

At trafficked road.

Background and near traffic pollutants from outdoor

Application of MEMORI - IAQ evaluation

Page 12: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Indoor location Some (but not all?) objects are glassed / in micro climate frames

- protection from gaseous and particulate pollution.

No windows - artificial lighting.

Air exchange with other rooms.

Air condition with RH / T control.

12 Room

Microclimate frame

Page 13: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Measurement results:

In room Inside MC-frame

Page 14: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

First case studies

14

Page 15: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

15

Page 16: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Measurement technology

16

EWO system - UV

(photo oxidizing effect) GSD system - IR

(acidic effect)

Dosimeter:

Damage risk to selected CH materials

Page 17: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

GSD

response Risk of damage to Lead

EWO

response

1.9 0.4

2.7 1.6

4.3 2.4

7.5 3.8

13.4 5.2

>13.4

>5.2

Based on known pollution and climate response of dosimeters 17

Page 18: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Object risk / Dosimeter response

Environmental parameters

18

Exposure studies:

“Traffic lights”

Page 19: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

MEMORI workflow

19

Page 20: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Mitigation

Detailed description of why and how to:

1. Reduce pollutant concentration, by:

Avoid

Block

Dilute

Sorb:

Filter

2. Reduce relative humidity.

3. Reduce oxygen concentration.

4. Retest air quality (measurement). 20

Page 21: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment

Thank you!

From the MEMORI partners

NILU-Norwegian Institute for Air Research, Norway

Fraunhofer Institute for Silicate Research, Germany

Kultur und Arbeit eV, Germany

NILU Innovation AS, Norway

University of Pisa, Italy

Birkbeck College, University of London, Birkbeck, UK

University of Ghent, Belgium

Royal Danish Academy of Fine Arts, School of Architecture,

Design and Conservation, Denmark

University of Natural Resources and Life Sciences, Austria

University of Arts "George Enescu", Romania

SIT Grupo Empresarial S.L, Spain

Tate, UK

Dublin City University, Ireland

Landesstelle Für Museumsbetreuung, Baden Württemberg,

National Museum of Krakow,

Museum of Cultural History. University of Oslo

Lithuanian Theatre, Music and Cinema Museum

Preservation Equipment Ltd (PEL)

Istanbul University (IU)

National Research Institute of Cultural Properties. Tokyo.

Musee National Picasso, Paris

Page 22: MEMORI A New Technology for Measuring Indoor Environment fileMadrid, 4th October, 2013 Terje Grøntoft, NILU and MEMORI partners MEMORI – A New Technology for Measuring Indoor Environment