DEPARTMENT OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa tervie w Blvd ., 3nd Floor Parsippany, NJ 070-5'4 ( 973) 331-4900 Fax: (973) 331-4969 Industry Information: . www.fda.gov/oq/ indus t ry OO.T'E(S) OF INSPECTliJOI 03/15/2013 - 04 /0 3/2013* FE! N.JMSER 3002902471 NMIEIHJ TIIU: Of' INDMOUAI. TO miOM ' REI'ORT lSSI£0 TO: G erry Tighe, President •lfi i.IIW.E MedPREP Consul ting, Inc. STREET IIDOIU!SS 1540 W Park Ave Ste 5 CITY, STAll:. 7!1P COOE, <AAII'I I on Tinton Fal ls , NJ 07712-3192 ·-'IYPE I!STA8USI'MEHT '"""""''"" Processor of Injectable Drug Products Thi s document lists observations made by the FDA reprcsentativc(s) duriDg the inspection of your facility. They are inspectional observations, and do not represent a final Agency determination regarding your compliance. If you have an objection regarding an observation, or have implemented, or plan to implement, corrective action in response to an observation, you may <liscuss the objection or action with tile FDA representative(s) during the inspection or s ubmit this info.rmati . on FDA at the address above. If you have any questions, please contact FDA at the phone number and address above. DURING AN INSPECTION OF YOUR FIRM WE OBSERVED: For tbe aseptic processing ofall injectable drog products in lV Bags and pre-fi1led syringes, such as: Magnesium Sulfute 2 grams in 50 mL 5% LOT: 0220138YNHMC, USE BY: 4/1612013 Heparin 5,000 units in lOOOmL of0. 9% NaCL, LOT: 0312138YNHMC, USE BY 04/1112013 Oxytocin 20 units added to Lactated Ringer's 1000 m.L, LOT: 0312137YHBH, USE BY: 4126/2013 Dexamethasone 20 mg in 50mL 0.9% Sodi\1111 Chloride, LOT: 0312139YNHMC, USE BY 04/02/2013 Vancomycin HCL added to 250mL 0. 9% SQdium Chloride, LOT: 031213l4YNHMC, USE BY: 4/11120 13 Phenylephrine 100 meg per mL, LOT: 0313 139STR. USE BY: 0412712013 QUALITY SYSTEM OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the fiillure o f a batch or any of i ts components to 1'tleet any of its specifications whether or not the batch has been already distributed. A . Your fum's complaint files indicate that within the last twenty-four months your firm incorrectly compounded, incorrectly labeled, or incorrectly packaged approximately 20 injectable drog products. You released and distributed those products and then needed to retrieve them from your customers for destruction or re-labeling. A thorough investigation was not conducted and corrective and preventative actions were not implemented or documented. Some examples from 2012 include: 1. A label control error resulted in a pre-filled syringe of Zosyn with 3.375 grams of active ingredient being incorrectly labeled to contain only 2.25 grams of the active ingredient (Lot l002127CCH USE BY: 11/0 112012). The firm's customer noticed tb e volume difference in the syringe, and this super-potent drug product was returned and. destroye<J. 2. A label error resulted in. syringes of Aztreonam with 2.0 grams of the active ingredient in 10 mL of Sterile Water For Injection being incorrectly labeled to contain only I .0 gram of the active ingJedient (LOT 0327121BCH, USE BY: 06!2 5/20 12). The firm's customer noticed the difference in the purchase order and this super-potent drug product was returned, re-labeled with tbe correct dosage strength, and SEE REVERSE OF THIS PAGE eMP!.O"IEEISJSIGNA TURE Russell Investigator James A. Liul;licicb, Investigator - Barbara J. W ilimczyk-Macri, I nve tigator Jose M. Cayuela , Investigator )-. 'A. cy A_ . DATE I8S\JEl) 04/03/2013 II()RM IDA 483 (.MIS) l'ltiMOlJSl!:olllONOIISOt£!lj JNSI'I.CTIONAL OBSERVATIONS PAOO I OF 8PAGES

Transcript of MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6...

Page 1: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

• • • • • •

DEPARTMENT OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION

Olsm«:TAllOReB6 AND PHONE N\MBER ,

10 Wa terview Blvd ., 3nd Floor Parsippany, NJ 070-5'4 ( 973) 331-4900 Fax: (973) 331-4969 Industry Information: . www.fda.gov/oq/ indust ry

OO.T'E(S) OF INSPECTliJOI

03/15/2013 - 04 /03/2013* FE! N.JMSER

3002902471

NMIEIHJ TIIU: Of' INDMOUAI. TO miOM ' REI'ORT lSSI£0

TO: Gerry Tighe, President •lfii.IIW.E

MedPREP Consul ting, Inc. STREET IIDOIU!SS

1540 W Park Ave Ste 5 CITY, STAll:. 7!1P COOE, <AAII'I I on

Tinton Falls , NJ 07712-3192 ·-'IYPE I!STA8USI'MEHT '"""""''""

Processor of Injectable Drug Products

This document lists observations made by the FDA reprcsentativc(s) duriDg the inspection ofyour facility. They are inspectional observations, and do not represent a final Agency determination regarding your compliance. Ifyou have an objection regarding an observation, or have implemented, or plan to implement, corrective action in response to an observation, you may <liscuss the objection or action with tile FDA representative(s) during the inspection or submit this info.rmati.on ~o FDA at the address above. If you have any questions, please contact FDA at the phone number and address above.

DURING AN INSPECTION OF YOUR FIRM WE OBSERVED:

For tbe aseptic processing ofall injectable drog products in lV Bags and pre-fi1led syringes, such as: Magnesium Sulfute 2 grams in 50 mL 5% Dextro~e, LOT: 0220138YNHMC, USE BY: 4/1612013 Heparin 5,000 units in lOOOmL of0.9% NaCL, LOT: 0312138YNHMC, USE BY 04/1112013 Oxytocin 20 units added to Lactated Ringer's 1000 m.L, LOT: 0312137YHBH, USE BY: 4126/2013 Dexamethasone 20 mg in 50mL 0.9% Sodi\1111 Chloride, LOT: 0312139YNHMC, USE BY 04/02/2013 Vancomycin HCL added to 250mL 0. 9% SQdium Chloride, LOT: 031213l4YNHMC, USE BY: 4/11120 13 Phenylephrine 100 meg per mL, LOT: 0313 139STR. USE BY: 0412712013

QUALITY SYSTEM

OBSERVATION 1

There is a failure to thoroughly review any unexplained discrepancy and the fiillure o f a batch or any ofits components to 1'tleet any ofits specifications whether or not the batch has been already distributed.

A . Your fum's complaint files indicate that within the last twenty-four months your firm incorrectly compounded, incorrectly labeled, or incorrectly packaged approximately 20 injectable drog products. You released and distributed those products and then needed to retrieve them from your customers for destruction or re-labeling. A thorough investigation was not conducted and corrective and preventative actions were not implemented or documented. Some examples from 2012 include:

1. A label control error resulted in apre-filled syringe ofZosyn with 3.375 grams of active ingredient being incorrectly labeled to contain only 2.25 grams ofthe active ingredient (Lot l002127CCH USE BY: 11/0 112012). The firm's customer noticed tbe volume difference in the syringe, and this super-potent drug product was returned and. destroye<J.

2. A label co~l error resulted in. pre~filled syringes ofAztreonam with 2.0 grams ofthe active ingredient in 10 mL ofSterile Water For Injection being incorrectly labeled to contain only I .0 gram ofthe active ingJedient (LOT 0327121BCH, USE BY: 06!2 5/20 12). The firm's customer noticed the difference in the purchase order and this super-potent drug product was returned, re-labeled with tbe correct dosage strength, and re~shipped.

SEE REVERSE OF THIS PAGE

eMP!.O"IEEISJSIGNATURE •

Russell Gl~pion, Investigator ~~/'~~·~ James A. Liul;licicb, Investigator - ~ Barbara J. Wilimczyk-Macri, Inve tigator ~~~------Jose M. Cayuela, Investigator )-.'A. cy A_ .

DATE I8S\JEl)

04/03/2013

II()RM IDA 483 (.MIS) l'ltiMOlJSl!:olllONOIISOt£!lj JNSI'I.CTIONAL OBSERVATIONS PAOO I OF 8PAGES

Page 2: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

DEPARTMENT OF HEALTH AND HUMAN SERVICES FOODANDDRUGADMna~TION

DATE(S) a' SPECTiON

03/15/2013 - 04/03/2013*

30029024 71

Waterview Blvd., 3rd Floor 07054 Fax: (973) 331-4969

Industry Inf ormation: www.fda.gov/oc / indust r

TO: Gerr Tighe, President f1RMHAME

MedPREP Consultin , I nc. 1540 W, Pa rk Ave Ste 5

Tinton Falls, NJ 07712-3192 Pr ocessor of Injectable Drug Products

0\U(S)SI 1VRe . ~ ' Russell Glapion,

in.

I nvestigator . ~ James A. Li'ubicich, Investigator . . · ~~SEE REVERSE Barbara J. Wilimczyk-Macri , rove tigato~~~;, ~ 04/03/2013

OF THIS PAGE Jose M. Cayuel a, I nvestiga tor ~~· ~ -~t/'

I!Oil!l!: PDA 433 ( JNSPECTIONAL OBSERVATIONS PAGE 20F IPAGBS

3 . A label control error resulted N bags ofMagnesium Sulfate Injection with 2.0 grams ofthe active ingredient being incorrectly labeled to contain only 1.0 gram ofthe active ingredient (LOT 0326121118 USE BY: 05/10120 12). The firm's customer noticed the purchase order discrepancy and this super-potent drug product was returned, re-labeled with the correct fonnuJation, and re-shipped.

4 A label control error resulted iollilll pre-filled syringes Zosyn 225 gram in sterile water being incorrectly labeled as Zosyn 225 gram in 5% Dextrose{tOT OJ 17129CCH USE: BY 02/1612012). The finn's customer noticed the mistake and this drug product was returned, re-labeled with the correct formulation , and re-shipped.

5. A secondary packaging error resulted i.n a light sensitive drugproduct,. N bags ofBupivacine, 0.5% Epinephrine 1:200,000 Normal Saline, not being packaged is in the correct protective bags (LOT 1008127R USE BY: I0128/2012). The firm's customer noticed the ritistake and drug product was returned and destroyed

6. II IV bags ofGentamin. 80 mg in 25 mL of0.9% NaCI, a frozen drug product, were shipped without temperature controls (LOT 06191210):'NHMC, USE BY: 07/1912012). This temperature abused drug product was rerumed and destroyed:

B. Investigations into product sterility and environmental morritoring test failures are not documented. Additionally, investigations into failing perfonnance challenges do not include the evaluation ofproduct impact.

~. You have your employees conduct a performance challenge oftbeir .aseptic technique on alii basis by having them use media at the end ofa processing run using the tailings ofthe chug product and the same container closure system that they just finished processing. Since 20 II, there were at least 20 failed employee perfmmance checks recorded after employees processed injectable drug products such as Heparin, A vastin, Oxytocin, and Norepinephrine. Contaminated aseptic performance check samples were analyzed and organisms such as bacteria (Staphylococcus sp. and Bacillus sp.) and mold (Penicillium spp) were identified. Your investigations into the failed performailce checks did not evaluate the possible impact on the finished 'drug product<;.

2. Your microbiological testing identified at least seven drug products in the last 26 months that had either turbid broth or particle matter floating in injectable drug products such as Lidocaine, Bevacizumab, Heparin and Famotidine. Althbugb re-test results are documented as passing inan environmental testing log, there is no investigation that · explains the basis upon which the test results were In used an in-house re-test pro>Ce<Jlllre that involves

3. There are no investigations into the two non-viable room particle count excursions. a. During the environmental monitoring on 05/1712012, particle counts of275, 127, and 154 were·noted at ISO 5

(Class 100) Laminar AirFlow Workbench 6, exceeding the specification of •• Your environmental testing Jog noted that the root cause was that the HEP A was turned offto change a pre-filter. There is no formal

Page 3: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

DEPARTMENT OF HEALTH AND HUMAN SERVICES FOOD AND DRUG ADMINISlRATION

DATE(S) OF IN~DIS """ """"""" A.'«lPIIO!E NUliiiiER

10 Waterview Blvd., 3r<;i floor 03/15/2013 - 04/03/2013* FEIN\JMBERParsippany, NJ 07054

(973) 331 - 4900 Fax : (973-} 331-4969 3002902471 Industry Information : www.fda.gov/oc/industry NAMe HIOTIIU' OF INCIV!Dl!Al TO'IIt!OM RfPCftT ISSUED

TO: Gerry Tighe., Presi dent ARM NAMe SlRI!El'ADDRESS

MedPREP Consult i ng, I nc. 154 0 W Park Ave Ste 5 rtPEESTMIUSHMeNf ntsPECTalCITY, STAlE, Z f'<OUUt. COUHil!Y

I!MPI.OYEE(S) S<GN<lllJRe OAltiSSUEO

Russell Glapion, Investigator ~~~~ James 11.. Liub i cich, Inves.tigator ~ •SEE REVERSE Barba:~;a J. Wilirnczyk-Macci, · Inve igator ~t~~ 04/03/2013

OF THIS PAGE Jose ~· cayuela, Investigator ~,.t(_ ~ .

row FDA .u<~~ l'ltliVlOUS fDITYOH<l8SOI.I:1E INSl'ECflONAL OBSERVATIONS PAGI! 3OF I PAGES

investigation to assess the possible impact ofthis deviation on the injectable drug products processed at this workbench (Atropine Batch# 0516121YOP1 , Atropine Batch ·# 0516121YOP2, Sodium Citrate Batch# 0517121NYPC, and Sodium Citrate Batch# 051712INYPCO). No corrective or preventive action was implemented to reduce the chance of this type ofdeviation from cx:cwring again .

b. On 0 I n.ono11, you recorded particle counts of555;. I 055, and 207 in the· ISO 6 (Class I ,000) area referred to as Buffer Zone 1 (BZI), near the cleanroom entrance and exit. You did not investigate the possible impact of this deviation on the injectable drug products processed near this area, or evaluate a possible root cause and implement a corrective or preventive action.

LABORATORY SYSTEM

OBSERVATION 2

Laboratory controls do not include the establishment ofscientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards ofidentity, strength, quality and purity.

Specifically, your firm produces approximately. lots .of injectable drug products per day and does not perform the foJlowing testing:

A. Assay or product identification testing for any sterile injectable drug product produced.

B. Sterility testing for ail produced is not performed. Less than 100/o ofthe injectable drug products are tested for sterility per day • • lots, on average) and those drug products are tested using non-<:ompendial methods that have not been vahdated to demonstrate that they are at least as good as the compendia! methods. The written test [Jlethod for the in-house steril~include the quantity ofdrug product to be tested. In addition, there is no assurance the media, • • , is capable ofdetecting all growth.

;acts

c. Endotoxin testing data for any lot ofsterile injectable drug produc~ produced.

D. Antimicrobial effectiveness testing to support drui{:duct "Use By" dates for sterile drug products containing preservatives. The firm processes approximately · · drug products with preservatives. For example, Oxytocin, which is labeled with a "Use By" date of45 days after the date ofpreparation.

OBSERVAnoN 3

Ail adequate number ofbatches ofeach drug product are ·not tested to detennine 8,[1 appropriate expiration date.

Specifically, you produce approximately 113 injectable drug prodUcts, including the different packaging sizes and containers

Tinton Falls, NJ 07712-3192 Processor of Injectable Drug Products

Page 4: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

DEPARTMENT OFBEALTII AND HUMAN SERVICES FOOD AND DRUG ADMINIS'm.ATION

I)ISTRICT I\DORE$$ ANO PHONE Nl.MieR DA.l t:(a) OFI"""ECTIOfl

10 Waterview Blvd., 3rd Floor 03/15/2013 - 04/03/2013"' Fa >A.IMBERParsippany, NJ 07054

(973) 331-4900 Fax: (973) 331-4969 3002902471 Industry Information,: www.fda.gov/oc/ industry - N10 TI1\.E a" II<OIYIO\.W.TOWHOM fW'<>I<T ISSUED

TO : Gerry Tighe, President FIRNNAMt.

MedPREP Consulting, Inc . CITY, STAll:. ZP C00E. CC\JNI'R'(

Tinton Falls , NJ 07712-3192

9·~·~~0-

1540 W Park Ave Ste 5 l'IPEE~ INSPECTUI

Processor of .Injectable Drl.!<l_ Products

EMPLOYEE(S) Sr<ONAl'tMI! DATE ISSUED

Russel l Glapion, Investigator ~~~ James A. Liubi cich, Investigator · . · · ' 'dSEE REVERSE Barbaz:a J . Wilimczyk-Ma~r1, Inves igator /,;!': · · ~~------· 04/03/2013

OF THIS PAGE Jose M. Cayuela, Investl.gator ~~~

FODf FDA oiO (OMI) I'IWVlOUS Hlmotl 08SOU!J'E INSl'ECnONAL OBSERVATIONS PAGG 4 Of8 PAGES

(IV bags or pre-1illed syringes,) For 94 ofthose drug products, you relied exclusively on literature searches to establish "Use By" dates for the drug product's. You have some stahility data on the other 19 drug products, but the studies for those drug products were incomplete. For example, there was no stability study protocol or final report for Oxytocin 80 Units in 1OOOmL Dextrose 5% Lactated Ringers (D5LR) N Bag, but there ~ testing data. at two time points. That limited data was extrapolated to support all other Oxytocin/Diluent combination "Use By" dates.

OBSERVATION 4

Reserve drug product samples are not retained and stored under conditions consistent with product labeling.

Specifically, you do not collect or store retains for any of the injectable drug products that you produce. Upon receipt of a complaint on March 14, 2013 for visible contamination in Magnesium Sulfate IV bags, you could. not visibly examine, nor perform any analytical testing ofretains.

FACILITIES AND EQUIPMENT SYSTEM

OBSERVATIONS

Equipment used in themanufacture, processing, packing or holding ofdrug products is not ofappropriate design to facilitate operatio~ for its intended use and. cleaning and maintenance.

Specificafly, your firm lacks adequate environmental monitoring data to. support that the process capabilities ofit<> cleamoom can maintain ISO 5 (Class 100) oonditioos at the . work stations, the ISO 6 (Class 1000) conditions in the surrounding area, and the ISO 7 (Class I 0,000) conditions in the gowning room (anteroom) given the following design linUtations and practices.

A. The ISO 7 gowning room serves as the entrance and exit for all personnel, sterile drug products, containers and closures! and non-sterile, non-sanitized processing equipment such as carts and totes that are brought in and out of the cleanroom numerous times during the work day.

B. ~leanroomHEPA filten have operated with leaks for at least one year without being rep o epa

c. There is a sink, an electric band blow drier, mops and other cleaning equipment stored in the ISO 7 gowning room.

D. Several cleanroom exhaust vents are blocked on either the inside or the outside ofthe cleanroom by shelves, bins, and totes.

E. There is an excess ofparticle generating non-sterile material mthe cleanroom such as clipboards with papers, adhesive notes attached to equipment, a radio, and a telephone.

Page 5: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

DEPARTMENT OFHEALl'llAND IIUMA.N SERVJCFS . FOOOANDDRUGADM!NISTRATION

10 Waterview Blvd., 3rd Floor 03 /15/2013 - 04/03/2013* Parsippany, NJ 07054 (973) 331-4900 Fax: ( 973) 331-4969 3002902471 Industry Information: www.fda.gov/oc/industry

TO: Gerry Tighe, FIRMIWIE

President

, Inc . 1540 W Park Ave Ste 5

Tinton Falls , NJ 07712-3192 Processor .of Injectable Dru Products

OATEISSOEDEMI'LOYEE(S) BIGNATIROE

Russell Glapion, Investigator ~~~ ' ~ . . ~ James A. L1.ubicich, Investigator · &i:7.u . ~SEE REVERSE Barbara J. Wilirnczyk-Macri , Inves igator h~~_.;..,.01,..--,.­ 04/03/2013

OF THIS PAGE Jose M. Cayuela, Investi gator 'Jeu.'A. ~ ·y""""

JI'OJIM FDA 413 INSPECfiONALOBStRVATIONS PAGB 5 OP 8 PAGES

F. (b) (4 ) is used as the final sanitizing agent in the cleanrootn.

G. Appro~tel. inadequately gowned employees. with exposed skin and ex{>Osed street clothes (see observation 6) work m a -square foot cleanroom. .

H. Smoke studies were not performed under dynamic conditions to verify that operators and processing equipment do not alter or impede the cascade ofair from the HEPA filters to the ISO 5 workbenches where injectable drug product is opened and manipulated, and to the rest ofthe ISO 6 cleanroom.

OBSERVATION 6

Clothing ofpersonnel engaged in the manufitcturlng and processing ofdrug products is oot appropriate for the duties they pewm. ·

Specifically, the gowning worn by employees entering the ISO 6 cleanroom includes an individually wrapped, non-sterile · laundered smock that is approximately knee-length. The smock can be reused during an operational day by banging it within the ISO 7 gowning room and sprayirtg th.e smock with (b) ( 4 ) before re-donning.

OBSERVATION 7

Written procedures for cleaning and maintenance filii to ·include maintenance and cleaning schedules, description in sufficient detail ofmethods, equipment and materials used, instructions for protection ofclean equipment from contamination prior to use, and parameters relevant to the operation.

... ..00 within yo..-cleauroom ;s not docwnented as an _.,ved;:specJ.aJtY Pharmacy Facility Cleaning, Rev. 09/08/06 which only lists • •

Additionally, there is no documentation to support that1he dilution of · · adequate as a sanitization solution.

OBSERVATION 8

The operations relating to the processing and packing ofpenicillin are not performed in facilities separate from those used for other drug products for human use.

Specifically, your firm. is processing Penicillin, and penicill.in-type injectable drug products such as Oxacillin, in the same cleanroom with your non-penicillin products. The absence of a structurally isolated area creates the potential that accidental breakage ofvials ofpenicillin could contaminate your other drug products. Additionally, the lack ofseparation creates the

Page 6: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

DEPARTME!IlT OF HEALTH AND HUMAN SERVICES FOOD AND DRUG ADMINlSTRATION

OIS"'IRICT"!)MESS 111<0 PilOtE -EER WI.TE(8) 01' IH&PE<:TlOH

10 Waterview Blvd., 3rd Floor 0.3/15/2013 - 04/03/2013* Parsippany, NJ 07054 fflHUMOE1'

(973) 331-4900 Fax:. ( 973) 331- 4969 3002902471 Industry Inforrr,ation: www.f<;ia.gov/oc/industry NAAII: N«llTil.E Of INOIIIIDUAL.lOWIIOU RS'ORT iS$JED

TO : Gerry Tighe, President fiRIIHAME 6~MXlRE8S

MedPREP Consulting, Inc. 1540 W Park Ave Ste 5 Cm', STAn<, zp <Xllle, COUNTRY TY?EESTABI.ISHMENT INSPECTI;O

Tinton Falls, NJ 07712- 3192 Pr.oce.s.so r of Inj ectable Drug Products

fM'I.Ova:(S) SlGHATlffi£ DAlCISO>UED -Russell Glapion, Investigator ~~~ · ·d SEE REVERSE .James A.. Liubicich, Investigator .)f;;;;;;; tt . · ~~ OF THIS PAGE

Barbara J. Wilimczyk-Kacri, Inves igator ~~~~ 04/03/2013 Jose M. Cayuela, Investigator ~-A(.~

fORM r»A m (Ciml_l P!li!VIOOS E!>llTONOBSOI.Sil! INSPECfiONAL OBSERVATIONS l'AGE60FIPAGES

risk that a penicillin product couid be mislabeled as a non-penicillin product. A number ofproblems with your product and label control were noted during the inspection. Patients allergic to Penicillin could be adversely effected (Observation lA).

OBSERVATION 9

Separate or defined areas to prevent contammation or mix-ups are deficient regarding the manufacturing and processing operations.

Specifically, your firm is processing beta-Lactam injectable drug products such as Cefaz.olin and Cefepime :from glass vials to IV bags and syringes in the same cleanroom with the rest ofyour non-Beta-Lactam drug products. The absence ofa structurally isolated area creates the potential that accidental breakage ofvials ofBeta-Lactam drug products could contaminate your other drug products. Patients allergic to Beta-Lactaal drug products could be adversely effected. Additionally, the lack: of separation creates the risk that a beta-Lactam drug product could be mislabeled as a non-Beta-Lactam drug product A number ofproblems with your product and label control were noted dwing this inspection (Observation lA).

MATERIALS SYSTEM

OBSERVATION 10

Written procedures are lacking which descn'bc in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection ofcomponents, drug product containers, and closures.

Specifically, you purchase or receiye from customers, sterile 8rticles including: dru,g products, diluents in IV bags, syringes, and sterile processing equipment You use these items to p~u.ce injectable drug products without assurance ofsterility by either qualifying the vendor and reviewing certificates ofsterility, or conducting your own quality assurance testing on those articles.

PRODUCTION SYSTEM

OBSERVATION 11

Master production and control records lack complete manufacturing and control instructions and s ampling and testing prooedures.

Specifically,

A. Your finn's Master Batch Records do not ~elude copies ofthe starting component label, so that individuals can verifY that the correct prodnct components are being used. In the last 24 months, approximately 20 finished

Page 7: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

...

DEPARTMENT OF HEALTH AND HUMANSERVICES FOOD AND DRUG ADMINISTRATION

PISlRICT ADDRfSS AND PHOIE NUMBER

10 Waterview Blvd., 3rd Floor Parsippany, NJ 07054 (973) 331-4900 Fax: (973) 331-4969 Industr. ov/oc/industr

TO: Gerry Tighe., President STREI!'r ADOII

M .re(S)OF INSPECTION

03/15/201~ - 04/03/2013*

3002902471

, Inc. 1540 W Park Ave Ste 5

Tinton Falls, NJ 07712-3192 Processor of In'ectable Dru Products

Y<E(S)SIGNA'l'\JRE

Russell Glapion, Investigator ~~- . < James A. Liubicich, Investigator _ .,;. •SEE REVERSE Barbara J. Wilimczyx- Macri, Inve~r ~~ ~~~~ 04/03/2013

OFTHISPAGE Jose M. cayuela,. Investigator }.sl_,q; ~ 't{' v.

!ORMFDA4U OM! JNS.PECfiONAL OBSERVATIONS PAG1!70f81'AGES

injectable drug products were distributed after they were incorrectly compounded. incorrectly labeled. or incorrectly · packaged (See Observation lA).

B. Your fum's Master Batch Records only require that the primary technician and the primruy p~armacist sign or initial the production record. When other technicians or phannacists assist, and/or work with part ofthe lot at another workstation, that information is not recorded. This does not allow for a complete review ofthe manufacturing process prior to finished product release or during any subsequent investigation. For example •. environmental monitoring data cannot be completely correlated to the all personnel!Wd applicable equipment

OBSERVATION 12

Procedures designed to prevent microbiological contamination ofdrug products putporting to be sterile are not established, written, and followed.

Specifically, A. Procedure 6.02, Microbiological and Environmental Testing/Alert and Action Thresholds and Retest Requirements,

does not ~ire immediate corrective actions for action limit excursions. The area or employee is retested an additionalJIQM and the location is only taken out ofservice ifit fails the retesl There have been at least 55 action reports since 2011, finding bacteria and mold from monitoring ofpersonnel gloves and gowns, and viable air samples. Examples include: . . 1. Bacillus pumilus and Paecilomyces spp .. (mold) ftom an employee glove, sampled on 05/24/11 (action level isII

or more eolony fonning units), result was 3 cfu; ~ested again on 05/31/11 with no ad~itional action taken. 2. Staphylococi;us hominis and Phialophora spp. (mold) from via~le air sample collected at Laminar AirFlow

3Workbench 10 (ISO 5) on 12/29/ll (action level isI cfu perm\ resUlt was 6 cfu per m ; retested again on 01/05/2012 with no additional action taken. ·

3. Bacillus cereus,.Brevibacillus lalerosporu.s, and Aspergillus spp. (mold) .from an employee's gloves and non­sterile gown, respectively, on 06/20/2012 (action level isI ormore and I or more, respectively); results were 6 and 5 cfu (gloves), and 16 cfu (non-sterile gown); the employee was retested again on 06!1.7/12 and 06/28/12, with no additional action taken.

B. Environmental monitoring testing conducted by your firm is inappropriate in that employees sanitize their gloves and non-sterile smock with (b) ( 4 ) before collecting personnel agar test plates.

C. The incubation ofthe enviro~ental monitoring surface contact and personnel agar test plates are incubated incorrectly. AU contact plates were observed jncubated wi1h the agar side down and not inverted, thereby allowing the condensation formed during incubation to possibly interfere with microbial growth.

D. Environmental monitoring is not performed on a frequent basis or during dynamic conditions. 1. Each IS0-5 workstation is not test~ for contact, viable, and non-viable environmental monitoring on a frequent

ba,sis. Environmental monitoring of each workstation is performed every~, at the conclusion of

Page 8: MedPrep Consulting, Inc. OFBEALm AND HUMAN SERVICES FOOD AND DRUG ADMINISTRATION Olsm«:TAllOReB6 AND PHONE N\MBER , 10 Wa terview Blvd ., 3nd Floor Parsippany,

DEPARTMENT OF HEALTH AND RUMAN SERVICES FOOD ANDDROO ADMINI3TRATJON

DOI.TE(S) OF INSPEC!lON Dl&·-· ....,.........NfiJ_,.,_.,. 10 Waterview Blvd., .3 rd Floor 03/15/2013 - 04/03/2013*

FEINUMBERParsippany, NJ 07054 (973} 331-4900 Fax: (973) 331-4969 3002902471 I ndustry Information: www.fda.gov/oc/industry - ~v • ·•~"'" INUVIUUJIL TOWHUNI to:J'UHI ISSU1!1'

TO: Gerry Tighe, .President $lREET AOOAe$8f--

MedPREP Consulting, Inc·. · 1540 W Park Ave Ste. 5 CITY. STATE,Zf> coco:, C¢UNTRI' T"'PP! ESTAeU8-IMSI'I:C1CO

Tinton Falls, NJ 07712-3192 Processor of Injectable Drug Products

fORM FDA 483 (~101) P.!UMOOS I!DillON OllliiJIB1l! INSPECI10NAL . OBSERVAnONS I'AG£80F8PAGES

SEE REVERSE OF THIS PAGE

~~~7

~

,.

..

compounding ofthe last operational day of that week, after most compounding operations have been completed.

2. Environmental monitoring ofpersonnel is not perfoimed each day of production. The testing is performed every... Additionally, Procedure, 6.02, Microbiol~cal and Environmental Testing, Implemented 07!29 002, does not reflect current practice because it lists · · surface samples to be collected instead ofthe three surface plates currently collected:

3. En:vironinental monitoring has not been petformed during operations representing the maximum nwnb'er of persqonel to demonsl;rate ~at . the IS0-6 classification of the cleanroom can be maintained.

OBSERVATION 13

Written procedUres are not drafted. review~ and approved by the appropriate organizational units.

Specifically, your finn does not have a system in place to track or assess the impact ofchanges made to processes, equipment, or procedures. There js no cbange ..contrOl system available for investigations into process deviations or failures.

"DATES OF INSPEC110N: 03il5f2~13(Fri), 03/l~Ol3(Mon); 03/1912013(Tuc:), 03120/2013(Wed), 03/2.1/201J(Thu), 03126!2013(Tue), 03f2812013(Thu), 04/03/2013(Wed)

EMPI.OYai(S) SION.l.TUAE

Russell Glapion, Investigator James A. Liubicich, In.vestigator · ~~ · ' ~Barbara J. Wil1lllczyk-Macri, Invest~~ ·Jose M. Cayuela, Investigator ..H~ >-:

!lATE ISSUEP

04/0.3/2013