Medica 2011 Presentation RScribe 5….

18
Medica 2011 Presentation RScribe 5…. November 2011

description

November 2011. Medica 2011 Presentation RScribe 5…. Key points regarding RScribe. New updated look and feel BEST 10 NEW Automated Timed ECG Capture New Full Disclosure capability Capture and print NEW VERITAS 7 interpretation WAM - Wireless patient Cable Lead Reversal - PowerPoint PPT Presentation

Transcript of Medica 2011 Presentation RScribe 5….

Page 1: Medica 2011 Presentation RScribe 5….

Medica 2011 Presentation RScribe 5….

November 2011

Page 2: Medica 2011 Presentation RScribe 5….

Key points regarding RScribe

• New updated look and feel• BEST 10• NEW Automated Timed ECG Capture• New Full Disclosure capability

– Capture and print• NEW VERITAS 7 interpretation• WAM - Wireless patient Cable• Lead Reversal • New diagnostic tools

– On screen calipers

Page 3: Medica 2011 Presentation RScribe 5….

First Impression – What’s New?......

• New and improved acquisition and analysis process with updates Veritas 7 algorithm– Comprehensive acquisition and analysis of new born through adult – Automatic lead reversal detection limb leads and chest leads– Best 10 or Last 10 selection– Full Disclosure Printing up to 60 minutes

• New update look and feel– New color display for 24” 1920 x 1080 resolution– Intuitive workflow for easier navigation through menu structure– Ability to customize the display

• With or without full disclosure• Real time presentation with 12 x 1 or 6 x 2 format• Real time data on blue screen and acquired data on Red grid showing what will print• Acquired ECG’s 3+1, 3+3, 6x2, 12, and Cabrerra

• AND Much more……………………

Page 4: Medica 2011 Presentation RScribe 5….

The NEW RScribe 5….

Completely redesignedwith the NEW Mortara

Colors and look

Patient Demographics

ECG Acquisition

Print Full Disclosure

Exit

Time Capture Clock

Full Disclosure ClockFull Disclosure Window

Heart Rate

Page 5: Medica 2011 Presentation RScribe 5….

Up to 60 minutes of Full Disclosure….

Up to 60 minutes of full disclosure

Real time data presented in a 12 x 1 or 6 x 2 format

User selectable full disclosure periods of:

• 5, 10, 20, 30, 45 or 60 minutes

FD Lead selection:• 1 lead by 3 rows• 1 lead by 6 rows • 3 leads by two rows

Print Rhythm Lead• Select Print Rhythm

and print of a single lead of full disclosure

Page 6: Medica 2011 Presentation RScribe 5….

NEW Automated Timed ECG Capture….

Automatic timed acquisition or user selected data

Automatic timed acquisition segment markers

Time to next

automatic capture

Page 7: Medica 2011 Presentation RScribe 5….

NEW Automated Timed ECG Capture….

Set timed increments as little as 20 seconds up to once at the end of acquisition

Page 8: Medica 2011 Presentation RScribe 5….

NEW VERITAS 7 interpretation….

Interpretation with measurements

Print ECG

Page 9: Medica 2011 Presentation RScribe 5….

Algorithms: features and benefits….

• VERITAS 7 Resting Interpretation Algorithm– Mortara Algorithm for Adult and Pediatric interpretation, from 0 days of

age through 100+ years of age– VERITAS in its latest revision, introduces several improvements,

better P-wave detection, enhanced Pacemaker analysis– Added STEMI message (*** ACUTE MI ***) statement

Page 10: Medica 2011 Presentation RScribe 5….

Measurement markers…..

Markers identify where measurements

were taken from

Edit interpretation and measurements

Page 11: Medica 2011 Presentation RScribe 5….

Algorithms: features and benefits….

• BEST 10– Acquiring an ECG on non-cooperating patients is a challenge. BEST 10

has been thought to help speed up this process. The RScribe 5 incorporates up to 60 minutes full disclosure that is used by the BEST 10 to find the best noise free 10 seconds of ECG data. Perfect for pediatric patients, agitated patients, and geriatric patients, it helps by saving time in the daily routine. Unique in this class of electrocardiographs!

Page 12: Medica 2011 Presentation RScribe 5….

Best 10 selection

By right clicking the mouse on the real time display, you can select

• Best 10 or

• Last 10

Page 13: Medica 2011 Presentation RScribe 5….

Algorithms: features and benefits….

• Lead Reversal – Lead placement is becoming a serious issue, important to the point that

it can lead to misdiagnosis: the technician may not realize the issue, the ECG is sent to the Cardiologist and the record may be read improperly.

– In some facilities more than 5% of all acquired ECGs are affected by lead reversal.

– v7 implements real time indication of lead reversal• Real time detection and indication to user of possible limb lead

swap• Real time detection and indication to user of possible precordial

lead (sequential V leads) swap…– Saves time and reduces error in ECG acquisition

Page 14: Medica 2011 Presentation RScribe 5….

Lead reversal?.....

Both chest and limb lead reversals are detected and presented for the clinicians notification.

Page 15: Medica 2011 Presentation RScribe 5….

The RScribe 5 patient cable interface….

WAM - Wireless patient Cable• For superior versatility and ease of use,

a digital front end that guarantees less noise and data quality

• UNIQUE in the Industry!!!!• Unsurpassed 40 KHz sampling rate• Frequency response 0.05 to 300 Hz• The best in class for adults and

pediatric ECG acquisition.• Remote control keys for easy and

fast ECG acquisition or Rhythm printout.

• Lead Fail indication• AM 12 available as optional

configuration

Page 16: Medica 2011 Presentation RScribe 5….

Communication: features and benefits….

• Report Manager– The transmission or file transfer can be perfectly integrated with the Report

Manager– With Report Manager and its import folder, the user can generate PDF files

(and other formats) automatically

Page 17: Medica 2011 Presentation RScribe 5….

Communication: features and benefits….

• Time Sync through Report Manager– The RScribe 5 allows time synchronization: a great tool to make

sure all the cardiographs are time-synchronized with the Hospital network. No need to manually change time at DST!

– The RScribe 5 also allows for Daylight savings time. This permits both a start time and date, along with an end time and date.

Page 18: Medica 2011 Presentation RScribe 5….

Some more key features and benefits….

• 12-Lead Preview– Thanks to the bright and sharp 24” LCD, allows the preview of what

will be printed• ECG Storage in Report Manager

– Internal memory allows a complete day of work– Available on the network

• 2D Bar Code reader with Exam Manager– Now available for the RScribe 5