![Page 1: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/1.jpg)
1
Mechanical Cooling:
A Tale of Two Systems
Chiswick Park, London
The two systems for large buildings:
• Compression-Based
• Absorption-Based
And you can’t tell from
the building’s exterior.
Caixa Forum, Madrid
Compression Cooling: Principle and Parable
Principle #1
• Compress gas – it heats up
• Decompress gas – it cools down
Parable #1
The scuba diver who doesn’t submerge his tank
while filling it burns his hands. (The water dissipates
the released heat of compression.)
![Page 2: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/2.jpg)
2
Compression Cooling: Principle and Parable
Principle #2 Change-of-State
• Liquid to vapor—absorbs
heat from environment
• Vapor to liquid—gives off
heat to environment
Parable #2
The person who’s hand is placed in steam (at
212ºF) is burned. (The steam condenses on the hand
releasing 970 btu/lb of water. You can put your hand
into a 500ºF oven for a short time without burning it.)
4 Components
Refrigerant properties:
• Boils at atmospheric pressure at ~0ºF
• Condenses at high pressure at ~100ºF
Hot arid solution: Swamp coolers
![Page 3: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/3.jpg)
3
…or use a ground source (geo-exchange)
Water-coupled
GeoExchange System
Jubilee CampusUniversity of Nottingham
—Michael Hopkins
Absorption Cooling
…what about equilibrium?
![Page 4: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/4.jpg)
4
The Basics:
Absorber & Evaporator
Add-ons for efficiency
![Page 5: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/5.jpg)
5
Solar-Powered
Absorption Cooling
Clearwater Times Bldg
Clearwater, FL
Compression Absorption
High pressure Low pressure
High grade fuel for
compressor & pumps
High grade fuel for
pumps
Energy efficient when
ground-coupled
Energy efficient when
solar-coupled
Noise, CFC use? Use of waste heat?
![Page 6: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/6.jpg)
6
The Big Picture
Cooling System Issues in Design
Cooling Towers
Replace with ground-source?
Heat Transfer Medium
Water vs. Air?
Centralized System
Isolate mechanical noise?
Thermal Zoning
Organize by thermal need?
Intelligent Buildings…require intelligent building
![Page 7: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/7.jpg)
7
Definition:
“Provides for unique and changing assemblies
of recent technology in appropriate physical,
environmental, and organizational settings—to
enhance occupants’ comfort/productivity/life
quality.”
Criteria 1
Accommodates integrated package of new
technology that manages:
• Communications
• Maintenance/Diagnosis
• Comfort
Eastgate, Harare, Zimbabwe by Mick Pearce
Criteria 2
Appropriate physical and environmental setting—
includes:
• Structure
• Massing
• Orientation
![Page 8: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/8.jpg)
8
Criteria 3
Address crucial environmental conditions such as:
• Spatial quality
• Physical safety
• Thermal, acoustic, & visual quality
• Indoor air quality
American Focus on workstation
Japanese Focus on core
European Focus on shell
British Focus on materials and details
Diversity of Approaches
American Approach: The Workstation
Personal environment by Johnson Controls
![Page 9: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/9.jpg)
9
Chesapeake Bay Foundation’s Headquarters:Phillip Merill Environmental Center
Smith Group
Workstations Perpendicular to South Organization
![Page 10: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/10.jpg)
10
Japanese Approach: The Core
Planning for thermal zoning
Life cycle cost analysis for a
9-story Tokyo building in 1984.
Farm Credit Bank, Spokane
![Page 11: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/11.jpg)
11
Thermally elegant building
British Approach: Materials and Details
Lloyds of London
![Page 12: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/12.jpg)
12
European Approach: The Shell
![Page 13: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/13.jpg)
13
So, Which is best?
❑ American
❑ Japanese
❑ European
❑ British
![Page 14: Mechanical Cooling: A Tale of Two Systems€¦ · 1 Mechanical Cooling: A Tale of Two Systems Chiswick Park, London The two systems for large buildings: •Compression-Based •Absorption-Based](https://reader034.fdocuments.in/reader034/viewer/2022042112/5e8d911a987fe7465d759eda/html5/thumbnails/14.jpg)
14
LEED & SPeAR
Smith Group Arup
It depends who is keeping score!
Learning from buildings: Vital Signs & POE