Measurement of Plasma Conditions at Shock Collapse on OMEGA

13
1 Measurement of Plasma Conditions at Shock Collapse on OMEGA J.J. Ruby University of Rochester Laboratory for Laser Energetics 60th Annual Meeting of the American Physical Society Division of Plasma Physics Portland, OR 5-9 November 2018 CD CH Shock Wave Fusion neutrons and x-ray emission

Transcript of Measurement of Plasma Conditions at Shock Collapse on OMEGA

Page 1: Measurement of Plasma Conditions at Shock Collapse on OMEGA

1

University of Rochester

Laboratory for Laser Energetics

Meeting

Location

Date

Measurement of Plasma Conditions at Shock Collapse on OMEGA

J.J. Ruby

University of Rochester

Laboratory for Laser Energetics

60th Annual Meeting of the

American Physical Society

Division of Plasma Physics

Portland, OR

5-9 November 2018

CD

CH

Shock

Wave

Fusion neutrons

and x-ray

emission

Page 2: Measurement of Plasma Conditions at Shock Collapse on OMEGA

2

Summary

• Constraint of electron temperature and density at the time of shock collapse is dependent on temporally and spatially measuring the x-ray self-emission.

• The hydrodynamics simulation code Lilac is used to inform x-ray observations and the conditions where x-rays are generated.

• Spectral content of x-ray emission is used to measure temperature at the time of shock collapse.

• An average ionization of a carbon-deuterium plasma at .89 keV is measured to be 2.4.

Plasma conditions generated by a collapsing radiative shock in spherical geometry have been measured via self-emission on OMEGA

Page 3: Measurement of Plasma Conditions at Shock Collapse on OMEGA

3

J. R. Rygg, C. J. Forrest, V. Yu. Glebov, D. A. Chin, and G. W. CollinsUniversity of Rochester

Laboratory for Laser Energetics

B. Bachmann, J. A. Gaffney, and Y. PingLawrence Livermore National Laboratory

H. W. Sio and N. KabadiPlasma Science and Fusion Center

Massachusetts Institute of Technology

Collaborators

Page 4: Measurement of Plasma Conditions at Shock Collapse on OMEGA

4

The OMEGA laser is used to drive a single spherically symmetric shock wave in a solid plastic ball at an initial pressure of about 30 Mbar

CD

CH

• Laser-drive configuration:

�2-ns square pulse

�21-kJ total energy

�60-beam symmetric drive

• Primary diagnostics:

�X-ray framing camera

�Filtered x-ray pinhole array

�Neutron counting diagnostics

• Target parameters:

�Central sphere of deuterated plastic (CD) with ~ 270 micron radius

�Outer shell of plastic (CH) with ~170 micron thickness

Page 5: Measurement of Plasma Conditions at Shock Collapse on OMEGA

5

Spherically collapsing shock waves amplify the initial pressure, are hydrodynamically robust+*, and have a simple solution developed by Guderley**

+ J.R. Rygg et. al. Phys. Plasmas. 15, 034505 (2008).* J. H. Gardner, D. L. Book, and I. B. Bernstein, J. Fluid Mech. 114, 41 (1982).** G. Guderley, Luftfahrtforschung 19, 302 (1942).

Shock Trajectory

Particle Trajectory

Page 6: Measurement of Plasma Conditions at Shock Collapse on OMEGA

6

The experiment is simulated using the 1-D hydrodynamics code Lilac to produce temperature and density profiles and synthetic x-ray images

* Spect3D, Prism Computational Sciences, INC. Madison, WI.

Simulated x-ray emission is confined to a narrow region spatially and temporally when the density peak is matched to the temperature peak.

Page 7: Measurement of Plasma Conditions at Shock Collapse on OMEGA

7

A neutron yield of 1 X 106 and the x-ray self-emission from a spherically collapsing shock wave was measured on the OMEGA laser

Space

Space Collapse

Emission

Coronal Emission

1

3

4

5

2

6

7

8

Page 8: Measurement of Plasma Conditions at Shock Collapse on OMEGA

8

A model for opacity must be used in order to derive information from the measured x-ray emission

• X-ray signal <15 keV affected by opacity • No x-ray signal >10 keV

Page 9: Measurement of Plasma Conditions at Shock Collapse on OMEGA

9

A single temperature fit to simulated x-ray emission returns the simulated temperature around peak density when an opacity model is used

Page 10: Measurement of Plasma Conditions at Shock Collapse on OMEGA

10

The data fit with the simulated opacity function returns a temperature of 890 eV

Page 11: Measurement of Plasma Conditions at Shock Collapse on OMEGA

11

Absolute x-ray yield along with spatial and temporal extent of the emission constrain the density

20 g/cc

10 g/cc

40 g/cc80 g/cc

Size of emitting region constrained to <10 microns by pinhole camera

Duration of emitting region constrained to <40 ps by framing camera

Page 12: Measurement of Plasma Conditions at Shock Collapse on OMEGA

12

• The narrow region of emission means neutrons and x-rays are emitted in the same location at the same time.

• X-rays and neutrons have the same dependence on mass density.

• Using this and the measured temperature the average ionization state can be deduced in the emitting region.

Comparing x-ray yield and neutron yield constrains the average ionization of the emitting plasma

< Z̄ >= 2.5

< Z̄ = 2.4 > T = .89 keVMeasured ionization and temperature:

Simulatedionization:

Page 13: Measurement of Plasma Conditions at Shock Collapse on OMEGA

13

Summary/Conclusion

Plasma conditions generated by a collapsing radiative shock in spherical geometry have been measured via self-emission on OMEGA

• Constraint of electron temperature and density at the time of shock collapse is dependent on temporally and spatially measuring the x-ray self-emission.

• The hydrodynamic simulation code Lilac is used to inform x-ray observations and the conditions where x-rays are generated.

• Spectral content of x-ray emission is used to measure temperature at the time of shock collapse.

• An average ionization of a carbon-deuterium plasma at .89 keV is measured to be 2.4.