Measurement of discharge by the ultrasonic (transit- time) method in “degraded mode” using computational fluid dynamics and data analysis Matthieu DUFRESNE, J.-B. Bardiaux, J. Vazquez, S. Isel, M. Fischer, A. Napoly Fluid and Solid Mechanics Institute of Strasbourg, France 9 th International Conference on Urban Drainage Modelling, Belgrade (Serbia), September 2012 Projects COACHS and MENTOR-2015

Transcript of Measurement of discharge by the ultrasonic (transit - time...

Page 1: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

1

Measurement of discharge by the ultrasonic (transit-time) method in “degraded mode” using computational

fluid dynamics and data analysis

Matthieu DUFRESNE, J.-B. Bardiaux, J. Vazquez, S. Isel, M. Fischer, A. Napoly

Fluid and Solid Mechanics Institute of Strasbourg, France

9th International Conference on Urban Drainage Modelling, Belgrade (Serbia), September 2012

Projects COACHS and MENTOR-2015

Page 2: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Outline

1. Context and objectives

2. Methodology: a. Discharge determination b. Degraded conditions

3. Conclusion

2

Page 3: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Context

Discharge measurement

Critical flow conditions (Venturi flumes, weirs…)

Ordinary conditions

Direct relationship between V and h

Need for only 1 water depth measurement

Need for 2 measurements

h and V in 1 cross section (presentation of

Laurent Solliec and this one) 3

h in 2 cross sections (presentation of Sandra Isel)

determination

Page 4: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Context

Cross-section view of the flow

• Measurement of V o “Doppler” devices

o Profilers (see the presentation of Laurent) o Transit time paths (this presentation)

• Main difficulty = the link between the measured velocity (local variable) and the mean velocity

(needed for the determination of the discharge)? • In particular for non-standard gauging stations

(complex geometry with singularities)!

Path n°1

Path n°2

Path n°3

4

Page 5: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Context

Cross-section view of the flow

Path n°1

Path n°2

Path n°3

5

In a “perfect” world In the actual world (communication problems)

? ? ?

? • The whole measurements are not generally lost. • For example path n°2 is not working.

• Advantage of multi-path systems: the whole information is not lost!

• How can we calculate the discharge in such degraded conditions?

(About 15% of loss for the dataset used in this study)

Page 6: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Objectives

6

• Objective: make discharge determination with ultrasonic transit-time method more reliable – Objective n°1:

o Development of a methodology for discharge determination for non-standard gauging stations

– Objective n°2: o Development of a methodology in degraded

conditions

Page 7: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Outline

1. Context and objectives

2. Methodology: a. Discharge determination b. Degraded conditions

3. Conclusion

7

Presented through one test-case: the gauging station ‘Milan’

Page 8: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

8

Presentation of the gauging station Milan

≈ 650 m

Gauging station “Milan”

CSO chamber 30° bend

Dissymmetric confluence

(Mulhouse, France)

1.60 m

Path n°1 Path n°2

Path n°3

Path n°4

h1 h2

Page 9: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Methodology for discharge determination

Gauging station (site, sensor, data)

Hydraulic analysis

CFD model

Q = f(h, V1, V2) Measurement data h, V1, V2

Discharge Q

(methodology presented at ICUD 2011) 9

Page 10: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

10

• Two paths are immersed:

• Three paths are immersed:

• Four paths are immersed:

Methodology for discharge determination

2211 05.105.1 SVSVQ ××+××=

44332211 10.106.191.091.0 SVSVSVSVQ ××+××+××+××=

332211 14.191.091.0 SVSVSVQ ××+××+××=

Page 11: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Methodology for degraded conditions

Q = f (h, V1, V2) Measurement data h, V1, V2

Discharge Q

• Optimal functioning: • Degraded conditions: • Example: path n°1 (V1) is not working

?

Data analysis

Correlation between variables

V1 = g (h)? V1 = g (V2)?

11

Q = f (h, g (V2), V2)

Page 12: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Correlation between variables

12

No simple link between h and V1 (variable downstream influence)

Good correlation between V1 and V2 for high water depths,

Nothing better for low water depths.

Page 13: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Results

13

• Comparison between optimal functioning and degraded mode (V1 is not working)

Non-negligible error but: • Better than loosing the data!

• Can be used for the management of the sewer.

Page 14: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Outline

1. Context and objectives

2. Methodology: a. Discharge determination b. Degraded conditions

3. Conclusion

14

Page 15: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

Conclusion

Gauging station (site, sensor, data)

Methodology for degraded conditions

Methodology for discharge

determination

15

• Main goal: make the discharge determination more reliable.

• Two perspectives: • Improvement of the degraded relationships while the data

are collected. • Investigation of more physical degraded relationships

(velocity profiles…)

Page 16: Measurement of discharge by the ultrasonic (transit - time ...hikom.grf.bg.ac.rs/stari-sajt/9UDM/Presentations/036_PPT.pdf · Conclusion . 2 . Context . Discharge measurement . Critical

16

Measurement of discharge by the ultrasonic (transit-time) method in “degraded mode” using computational

fluid dynamics and data analysis

Matthieu DUFRESNE, J.-B. Bardiaux, J. Vazquez, S. Isel, M. Fischer, A. Napoly

Fluid and Solid Mechanics Institute of Strasbourg, France

9th International Conference on Urban Drainage Modelling, Belgrade (Serbia), September 2012

Projects COACHS and MENTOR-2015