    mBSC-CCombined Multi-Band, Multi-System, Multi-Carrier Coverage System

    June 2012

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    2/53

    FIBER MBSC-C

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    3/53

    About mBSC-C

    BTI mBSC-C( Combined multi-Band, multi-System,multi-Carrier) Coverage System provides costefficiency, fast & easy installation, flexibility andscalability to the Tunnel/Subway, In-Building networkespecially for multi-band, multi-system, multi-carrierand multi-operator scenario.

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    4/53

    mBSC-C Composition

    POI Host Unit

    Remote Unit

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    5/53

    POI

    19 1U rack

    35 dB TX path attenuation

    Separated RX path insuresoptimum uplink noise figure

    Fan cooled high density design

    Fan alarms via Host Unit

    43.7

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    6/53

    Host Unit

    FIU

    (Fiber Interface Unit )

    BIUBase station Interface Unit

    RCURemote Control Unit

    PSU

    Power Supply Unit

    482.6

    177

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    7/53

    Host Unit

    -48 VDC redundant

    connections

    POI Fan Power

    interface and monitor

    Dry Contact (Form C) alarm output

    Input Alarms

    AC220V

    Redundantconnections

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    8/53

    Host Unit ComponentsPSU , Power Supply Unit

    Provide power for the host unit shelf

    Fully redundant PSUs

    Hot swappable (one at a time)

    No configuration options

    Recessed Power Switch

    LED Status Indicator

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    9/53

    Host Unit ComponentsRCU , Remote Control Unit

    Provides the control and interface for NMSGraphical User Interface

    Ethernet connectivity for remote access

    Interface to NMS Server

    Simple Configuration (IP Address only)

    RCU is a hot swappable card and will not haltoperation of the RF path if removed

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    10/53

    Host Unit ComponentsBIU , Base station Interface Unit

    The BIU is a frequency

    agnostic interface cardthat provides all inputand output connectionsfor the BTS

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    11/53

    Host Unit ComponentsFIU , Fiber Interface Unit

    Functions as theinterface between thecombined RF signals(BIU) and the optical

    fiber connections.

    Providesautomatic optical

    link budgetcompensation of

    up to 10 dB

    Five bandssupported on asingle fiber strand

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    12/53

    Remote Unit ComponentCombiner Unit

    Combiner Unit

    CM-BTS CM-ANT

    750 x 83 x 250 mm

    Provides Electrical-Optical/Optical-Electrical

    signals conversion

    Provides RF signalscombination and

    separation for RU units

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    13/53

    Remote Unit ComponentSingle-band Unit

    Fan cooled 20W Single-band Unit

    1800MHz

    2600MHz

    800MHz

    900MHz

    2100MHz

    645 x 84.5 x 250 mm 720.15 x 84.5 x 250 mm

    Provides forward pathRF signals amplifying

    Provides reverse pathRF signals sensitivity

    improvement

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    14/53

    Combiner UnitUser Interface (800-2600MHz Example)

    O/E and E/O conversionconnection with Host Unit

    RF inter-connection with

    remote band units

    Fiber CM-BTS

    Point of interfacesconnected withantenna(s)

    Passive device

    CM-ANT

    A

    B

    TX_OUT RX_IN

    CDMA0.8G

    A

    B

    TX_OUT RX_IN

    GSM0.9G

    A

    B

    TX_OUT RX_IN

    DCS1.8G

    A

    B

    TX_OUT RX_IN

    WCDMA2.1G

    A

    B

    TX_OUT RX_IN

    LTE2.6G

    VENT

    DEBUG AC FIBER

    A

    B

    ANT-B

    ANT-A

    CDMA0.8G-B GSM0.9G-B DCS1.8G-B WCDMA2.1G-B LTE2.6G-B

    CDMA0.8G-A GSM0.9G-A DCS1.8G-A WCDMA2.1G-A LTE2.6G-A

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    15/53

    Remote Unit ComponentBand Unit

    Monitoring LEDs are provided to show alarm status of each

    of the units

    RF output N type female

    110 to 220 VAC automatically supported

    Available Bands

    700Mhz 800MHz 900MHz 1800MHz 2100MHz 2600MHz

    Available in 20 or 40 watt units

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    16/53

    Single-band UnitUser Interface

    TX_OUTRX_OUT

    VENT FANAC

    RUN

    ANT

    RF Inter-connection from

    Fiber CM-BTS Unit

    DC Power to FanAC 220V Power INRF Output to CM-ANT Unit

    LED Indicator

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    17/53

    Remote Unit ComponentSide Mount Bracket

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    18/53

    Remote Unit ComponentMounting Panel & Shroud

    Small bracket & Shroud

    For up to 3xRUs

    Large bracket & Shroud

    For up to 6xRUs

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    19/53

    System Configuration

    800M+900M+1.8G+2.1G+2.6G for Middle East and South EastAsian market.

    700M+800M+1.9G+2.1G+2.6G for US and Europe market.

    Maximum configuration to support 5-band

    SISO and/or MIMO available

    Versatile RF IN/OUTsmoothly modification between duplex and simplex

    Flexible deployment

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    20/53

    System Configuration Example800M+900M+1.8G+2.1G+2.6G

    800M x 1

    900M x 1

    1800M x 1

    2100M x 1

    2600M x 1

    POI configuration

    PSU x 2

    RCU x 1

    BIU x 1

    FIU x 4

    Host Unit configuration (1 HU carries 4pcs RU)

    CM_BTS x 1 CM_ANTx 1

    RU800M x 1 -20W

    RU900M x 1 -20W

    RU1.8G x 1 -20W

    RU2.1G x 1 -40W

    RU2.6G x 1 -40W

    Remote Unit Configuration (w/o MIMO, w/o diversity)

    POI 800M

    POI 900M

    POI 1800M

    POI 2100M

    POI 2600M

    BIU

    FIU

    FIU

    FIU

    FIU

    RCU

    PSU

    PSU

    CM_BTS

    RU800

    RU900

    RU1800

    RU2100

    RU2600

    CM_ANT

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    21/53

    Completed Configuration ExamplePOI

    POI 800M

    POI 900M

    POI 1800M

    POI 2100M

    POI 2600M

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    22/53

    Completed Configuration ExampleHost Unit

    FIU

    FIU

    FIU

    FIU

    BIU

    RCU

    PSU

    PSU

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    23/53

    Completed Configuration ExampleRemote Unit

    CM_BTS Unit

    900M Unit(20W)

    1800M Unit(20W)

    2100M Unit(40W)

    2600M Unit(40W)

    CM_ANT Unit

    Mounting

    Bracket & Panel

    Pole

    Shroud

    Power Distribution Unit

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    24/53

    COMBINER UNITCONFIGURATION EXAMPLE

    Remote Unit

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    25/53

    Combined Duplex OutputExample: 4 bands

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    26/53

    Combined Simplex OutputExample: 4 bands

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    27/53

    LTE2600 SISO/MIMO UPGRADE

    Fiber MBSC-C

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    28/53

    LTE2600 SISO UpgradeDuplex Output

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    29/53

    LTE2600 SISO UpgradeSimplex Output

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    30/53

    LTE2600 MIMO UpgradeDuplex Output

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    31/53

    LTE2600 MIMO UpgradeSimplex Output

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    32/53

    IN-LINE MBSC-C

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    33/53

    Generic Block Diagram

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    34/53

    In-line mBSC-C Composition

    Convection Combiner Unit Bracket & Shroud

    CM-BTS CM-ANT

    750 x 83 x 250 mm

    Fan cooled 20W Single-band Unit

    1800MHz

    2600MHz

    800MHz

    900MHz

    2100MHz

    645 x 84.5 x 250 mm 720.15 x 84.5 x 250 mm

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    35/53

    RX_OUT

    VENT FANAC

    RUN

    ANT

    TX_IN

    Single-band UnitUser Interface (Each Band)

    Composite RF(TX/RX)

    outpu t to CM-ANT

    (N type female)

    Grounding

    stud

    Power Supply

    220V AC

    Power supply for fan

    Summary LED

    indicator

    RF_Rx to

    CM-BTS

    RF_Tx from

    CM-BTS

    The user interfaces example layout is subject to change without prior notice.

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    36/53

    System Completed Overview

    CM-BTS

    1800 Unit

    800 Unit900 Unit

    2100 Unit

    CM-ANT

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    37/53

    System Completed Overview

    Power Supply

    Distributer

    Power Supply Distributer:

    Size: H x W x D = 135mm x 330mm x 95 mm

    Connectors:

    Input: 220V AC :1 PCS

    Ouput: 220V AC: 6 PCS

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    38/53

    DUPLEX / SIMPLEX

    Flexible Interfaces Configuration

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    39/53

    Combiner UnitCM-BTS (Duplex & Simplex)

    Interfaces in Blue are reserved

    for future expansion.

    From Duplex to Simplex

    configuration, just need to

    MODIFYthe INTER-

    INTERFACES as shown in left.

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    40/53

    Combiner UnitCM-ANT (LTE2600 SISO Example)

    Interfaces in Blue are reserved

    for future expansion.

    From Duplex to Simplex

    configuration, just need to

    MODIFYthe INTERIOR

    JUMPER CONNECTION as

    shown in left.

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    41/53

    COMPLETE CONFIGURATIONEXAMPLE

    In-line mBSC-C

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    42/53

    Simplex IN & OUT with 2.6GHz SISO

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    43/53

    Duplex IN & OUT with 2.6GHz MIMO

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    44/53

    MBSC NMS

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    45/53

    Function

    BTI NMS is the Operation andMaintenance Center, based on state-of-the-art mechanisms and technologies.

    It consists of extensive functionality for:

    Configuration Management

    Fault Management

    Performance Management

    Administration

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    46/53

    Overview of NMS Tasks

    NMS Tasks

    Add/edit/delete the region and site

    Add/edit/delete the elements which

    need to be monitored in NMS

    Determine the network elements

    that are currently connected

    Query selected parameter(s)

    Check polling report

    Check for status

    Real-time alarms

    Alarm history

    Check for alarms

    Alarms

    Polling results

    Check for statistics

    UL/DL Gain setting

    Threshold setting: VSWR, temperature, output power

    Enabling switch: alarm, function

    Equipment configuration

    Add/edit/delete user accounts

    Add/edit/delete user group

    Managing user access level

    Managing User Accounts

    Customizing shortcuts

    Managing home page

    Managing User Interfaces

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    47/53

    Use of Communication

    UDP

    SERIAL MODEM

    TCP

    Dynamic IP in public network (Internet)

    Connected equipments will automatically

    report their IP and port to NMS

    RS232 for local link

    Wired or wireless

    SMS/DATACALL/GPRS/3G

    available

    Fixed IP in private network (LAN)

    NMS connects the equipments

    actively

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    48/53

    System Requirements

    CPU multi-core, 2.5G or aboveRAM Min. 4GHard disk 500GBGraphic card Min. VGA 16MB

    (1024x768 pixels resolution or above)Network 100MB Ethernet connection or aboveCommunication

    port Minimal one Serial Communication Port and one USB port areneeded

    Hardware Requirement:

    Software Requirement:

    Operation system Microsoft Windows2003 server or aboveDatabase Postgresql9.0 or aboveWEB Server JBoss AS 4.2.2JDK JDK5

    Example: Dell PowerEdge r210

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    49/53

    Check for Status

    Go to Element -> Equipment List -> double click the selected equipment item

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    50/53

    Check for Alarms

    Go to Alarm -> Real-time Alarm List -> Monitoring

    h k f l

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    51/53

    Check for AlarmAlarm Forwarding

    Go to Alarm -> Alarm Advice

    Ch k f l

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    52/53

    Check for AlarmAlarm Severity

    Go to Alarm -> Alarm Severity

  • 7/29/2019 mBSC-C Introduction EN 20120620.pptx

    53/53

    ThanksBravo Tech Inc.

    6185 Phyllis Dr. Unit D. Cypress,

    CA 90630, USA

    Tel: +1 714-230-8333

    FAX: +1 714-230-8341

    Bravo Tech (Shenzhen) Ltd.

    No.8 Building, Zone #3, Tangtou Industrial Park,

    Shiyan, Baoan District, Shenzhen, Guangdong

    P.R.China 518102

    Tel: +86-755-3690 6999

    Fax: +86-755-2951 2299

    Bravo Technologes(S) Pte. Ltd.

    Block 261, Waterloo Centre,

    #02-06 Waterloo Street,

    Singapore 180261

    Tel: +65 6337-2018

    Fax: +65 6336-0328

    Bravo Tech International Ltd.

    Unit 713-714, Chevalier Commercial Centre,

    8 Wang Hoi Road, Kowloon Bay,

    Hong Kong

    Tel: +852 2416-5330

    Fax: +852 2394-1889