MBR Technologies · of an MBR system, housed within one compact skid mounted case. The package...

3
MBR Technologies Packaged Tertiary Treatment System > ® ®

Transcript of MBR Technologies · of an MBR system, housed within one compact skid mounted case. The package...

Page 1: MBR Technologies · of an MBR system, housed within one compact skid mounted case. The package includes: Stainless Steel membrane tank and pipework, correctly sized pumps, aeration

MBR Technologies

Packaged Tertiary Treatment System >

®

®

Page 2: MBR Technologies · of an MBR system, housed within one compact skid mounted case. The package includes: Stainless Steel membrane tank and pipework, correctly sized pumps, aeration

> MeMCASe® PACkAged TeRTiARy TReATMenT SySTeM

The MemCASE® is an advanced add-on, ‘plug and play’ packaged MBR tertiary treatment system featuring the BIO-CEL® flat sheet submerged MBR ultrafiltration modules. The MemCASE® is engineered to provide a high quality effluent, treated to Class A standards and suitable for reuse applications.

> MeMCASe® feATuReS BiO-CeL® SuBMeRged MBR MOduLeS

Central to the MemCASE® design is the German manufactured BIO-CEL® submerged flat sheet ultrafiltration membrane module. Featuring a unique patented flat sheet composite polymer membrane, the BIO-CEL® is naturally resistant to fouling, clogging and braiding. Due to its unique membrane structure, the BIO-CEL® is the only flat sheet membrane system capable of being back flushed under pressure using permeate water. Fully automatic backwash cleaning cycles help to maintain stable flux rates and reduce the need of chemical assisted cleaning operations.

• Plug and play packaged system

• Easily incorporated into new or existing designs

• BIO-CEL® flat sheet MBR module

• 0.04µm Ultrafiltration membrane

• Stainless steel tank and pipe construction

• Automatic cyclic membrane backwash and CIP System

• Fully self contained operation or can be linked to existing control system

• Proven design

• Fully Factory Tested

• Systems available from 10 - 400kl/day

• Compact and easy to transport

• Optional UV disinfection

• Optional chlorine dosing

• Optional effluent monitoring system

> key feATuReS

Using a MemCASE® module greatly simplifies the design and engineering requirements of a Class A wastewater treatment plant. Replacing the traditional clarifier stage for sludge separation, the MemCASE® incorporates all dedicated components of an MBR system, housed within one compact skid mounted case.

The package includes: Stainless Steel membrane tank and pipework, correctly sized pumps, aeration blower, dosing systems and valves. The pre-programmed PLC control system includes full process monitoring and data logging functions and features addition inputs and outputs, designed for control of other plant operations.

The MemCASE® can be incorporated into a new treatment plant design requiring only inlet works, process tanks and aeration equipment. Alternatively, the MemCASE® can be retrofitted in place of the clarifier tank to upgrade an existing plant.

A range of models are available with capacities from 10 m³ per day upwards. Effluent from a MemCASE® system is an ideal supply for a reverse osmosis polishing plant.

> MEMCASE® Positive Displacement Pump

> MeMCASe® TyPiCAL LAyOuT

> deSCRiPTiOn Of MeMCASe® OPeRATiOn

During operation, MLSS is pumped from the aeration bioreactor to the inlet of the MemCASE® filtration tank at a rate of 4 to 5 times the permeate flow rate. MLSS fills the tank and flows by gravity back into the aeration tank. Fine bubble aeration diffusers mounted below the BIO-CEL® module creates a turbulent circulating current of MLSS over the surface of the membrane panels.

The positive displacement flexible vane permeate pump creates a slight negative pressure within the membrane panels, drawing water through the membrane pores. Solids, bacteria and viruses are too large to pass through the pores and are carried on with moving MLSS. Permeate water enters the base of the permeate storage tank and flows by gravity from the tank top outlet.

An automatic cyclic backwash takes place every 10 minutes. The permeate pump stops, then reverses, pumping a small amount of water from the permeate storage tank, back through the membrane to clear membrane pore fouling.

> MEMCASE®-100

> BC100 module

AERATION TANK

WASTEWATER

PERMEATE

Page 3: MBR Technologies · of an MBR system, housed within one compact skid mounted case. The package includes: Stainless Steel membrane tank and pipework, correctly sized pumps, aeration

MBR TeCHnOLOgieS

Street Address > 47 Allied Drive, Tullamarine VIC 3043 Postal Address > PO BOX 1371, Tullamarine VIC 3043

P: +61 3 9338 8450 F: +61 3 9338 8470 E: [email protected]

www.mbrtech.com.au

> MeMCASe MBR® SPeCifiCATiOnS

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

......................................................................................................................................................................................................................

MEMCASE MODEL

Membrane surface areaRated flow Rated flow Operating temperaturepH rangeMLSS recirculation rate

MembraneMembrane materialMWCOPore sizeChlorine resistance Max suspended solidsMin suspended solids

Connections: PermeateMLSS RecirculationSludge extraction

Dimensions: LengthWidthHeightTank volume

UNIT

m²L/Hr m³/day°C

m³/Hr

kDaµmppmhg/Lg/L

mmmmmm

mmmmmmm³

MEMCASE-101017045°C - 40°C2 to 110.7

BIO-CELPES1500.04100,000124

255050

183098021900.78

MEMCASE-5050850205°C - 40°C2 to 114

BIO-CELPES1500.04100,000124

406565

1680168022852.98

MEMCASE-1001001,700405°C - 40°C2 to 118

BIO-CELPES1500.04100,000124

406565

2510168022854.6

MEMCASE-4004006,8001605°C - 40°C2 to 1132

BIO-CELPES1500.04100,000124

508080

29102500348013.73

MEMCASE-80080013,6003205°C - 40°C2 to 1164

BIO-CELPES1500.04100,000124

___

20' ISO Container""_

MEMCASE-2002003,400805°C - 40°C2 to 1116

BIO-CELPES1500.04100,000124

508080

10' ISO Container""_

®