MAXSYS Version 3.3 Integrated Systems Integrated Technology!

download MAXSYS Version 3.3 Integrated Systems Integrated Technology!

If you can't read please download the document

Transcript of MAXSYS Version 3.3 Integrated Systems Integrated Technology!

  • Slide 1

MAXSYS Version 3.3 Integrated Systems Integrated Technology! Slide 2 The MAXSYS Panel: Integrated Product with Single Software Design Combines 4 Systems: Burglary Fire Access Control Automation Full Upload/Download Programming User-Friendly System Administration Software DLS-3 SA MAXSYS Version 3.3 Introduction Slide 3 16 Zone, Expandable to 128 Hardwire, Wireless, Addressable Expansion Maximum 16 LCD Keypads 8 Partitions 1500 User Codes 3000 Event Buffer Supervised Digital Communicator 3 Phone Numbers, 9 Account Numbers 1 Supervised Bell Output Local Upload/Download with PCLINK Connector MAXSYS Version 3.3 Introduction Overview: Slide 4 PC4108 Zone Expander 8 Hardwire Zones PC4116 Zone Expander 16 Hardwire Zones Connect any Number of Modules to Expand the System up to 128 Zones MAXSYS Version 3.3 Hardwire Expansion PC4108/4116 Hardwire: Slide 5 MAXSYS Version 3.3 Addressable Expansion Two-Wire Addressable Loop PGM1 and PGM2 can both be used Each can provide up to 170 mA of current Connect up to 128 Addressable (AML) Detectors Does not require any additional modules Isolators and Repeaters Available AML-770 Isolator Module AMX-400 Isolator/Repeater Module Addressable: Slide 6 MAXSYS Version 3.3 Addressable Expansion AMB-300 Standard PIR AMB-500 Ceiling Mount PIR AMB-600 Pet Immune PIR AMA-100 Glassbreak Detector AMS-220 Smoke Detector AMP-700/701 Contact Modules AMP-702 Fire Input Module Burglary Detectors Fire Detectors Slide 7 MAXSYS Version 3.3 Addressable Expansion AMB-300 AMB-500 AMB-600 AMP-701 AMS-220 AMA-100 Use 2-wire addressable loops to easily expand to full system capacity without the added cost of system expansion modules. AMX-400 AML-770 The AMX-400 can be used to repeat the data loop allowing for longer wire runs. In addition, it will isolate the loop in the event of a problem. The AML-770 can be used to isolate fire detectors from burglary detectors so they can be connected to the same wire run. Slide 8 MAXSYS Version 3.3 Wireless Expansion Supports up to 64 Wireless Zones Supports up to 16 Wireless Keys Wireless keys do not use up zones Uses the PC4164-433 MHz Wireless Receiver Module Connect up to 8 PC4164-433 Modules for: Distributed wireless reception Larger coverage area Allows users to move through larger area with wireless panic pendants and wireless keys without being out of range Wireless: Slide 9 MAXSYS Version 3.3 Wireless Expansion PC4164-433 Wireless Receiver WLS904PL Pet Immune Motion WLS914 Pet Immune Motion WLS907T Low Temperature Sensor WLS925L Door/Window Contact WLS912L Glassbreak Detector WLS906 Smoke Detector WLS919 Wireless Key WLS918 Panic Pendant Connect up to 8 PC4164-433 Modules Total number of wireless zones is 64 Total number of wireless keys is 16 Slide 10 MAXSYS Version 3.3 COMBUS Bi-Directional RS-485 Communication Bus for Modules Four wire, non-shielded cable Red/Black for power, Yellow/Green for data All Modules Connect to the COMBUS Modules can be home run, daisy-chained, t-tapped Total wire used cannot exceed 5,000 feet Additional Power Supplies Available PC4204 power supply with 4 relay outputs PC4204CX power supply/COMBUS repeater with 4 relay outputs COMBUS: Slide 11 MAXSYS Version 3.3 Modules Slide 12 MAXSYS Version 3.3 Burglary Modules Keypads: LCD4500 LCD Keypad Programmable Alphanumeric Keypad LCD4501 LCD Keypad Programmable Alphanumeric Keypad 5 Programmable Function Keys Connect up to 16 Keypads Maximum Slide 13 MAXSYS Version 3.3 Burglary Modules PC4108 Zone Expander 8 Hardwire Zones PC4116 Zone Expander 16 Hardwire Zones Current Draw 30 mA AUX Output to Provide Power for Detectors Zone Expanders: Slide 14 MAXSYS Version 3.3 Burglary Modules Output Modules: PC4204 Power Supply 1 Amp Power Supply PC4204CX Power Supply 1 Amp Power Supply (40 VA transformer) 2.2 Amp Power Supply (80 VA transformer) COMBUS Repeater Modules Supervised for Low Battery, AC Failure and Aux Output Failure Modules have 4 Programmable High Current Relays Slide 15 MAXSYS Version 3.3 Burglary Modules Output Modules: PC4216 Output Module Provides 16 Low Current Outputs Outputs Rated at 50 mA Connect up to 9 Modules for 144 Outputs Typically Used for Annunciation PC4632 32 Point Annunciator 8 x 11 inch display area PC4664 64 Point Annunciator 11 x 17 inch display area Slide 16 MAXSYS Version 3.3 Fire Modules Fire Features All 128 Zones can be used for Fire Hardwire or Addressable Dual Phone Line Dialer Module 24 VDC Notification Appliance Outputs Annunciators Auto-Scroll Alarms Fire Inspector Test User Initiated Fire Drill Slide 17 MAXSYS Version 3.3 Fire Modules Keypads: LCD4520 LCD Fire Keypad Programmable Alphanumeric Keypad LCD4521 LCD Fire Keypad Programmable Alphanumeric Keypad 5 Programmable Function Keys Connect up to 16 Keypads Maximum Slide 18 MAXSYS Version 3.3 Fire Modules Annunciators: PC4612 Fire Annunciator 10 Fire Zones, 2 Supervisory Zone, Bell and System Trouble AC Indicator PC4632/PC4664 Annunciators 32 or 64 Point Annunciators Uses PC4216 Modules (up to 4) Slide 19 MAXSYS Version 3.3 Fire Modules Dialer Module: PC4701 Two Line Dialer Module Includes: Connection for two Separate Phone Lines One 2-Wire, Class B/Style B Smoke Detector Zone One Class B/Style B Waterflow Zone Form C Fire Alarm Relay Form C Fire Trouble Relay Slide 20 MAXSYS Version 3.3 Fire Modules Output Module: PC4702BP Bell Panel Up to 4 Modules per System Two Alarm Notification Outputs 24 VDC, 1.8 Amps each Outputs supervised PTC Protected Outputs will self-restore when problem corrected Includes 28 Volt, 180 VA Transformer Red Cabinet Slide 21 MAXSYS Version 3.3 Fire Modules Power Supply: PC4204CF Power Supply Up to 16 Modules per System Provide up to 1 Amp Fully Supervised for: Low battery, AC failure, AUX output failure Four Programmable High Current Relays Includes 16 Volt, 40 VA Transformer Red Cabinet Slide 22 MAXSYS Version 3.3 Fire Modules Battery Charger: PC4350 External Battery Charger Includes: PC4085 Charger Module Red Cabinet 16 VAC, 80 VA Transformer Used to Charge up to 60 Ah of Batteries Auto Shutdown to Prevent Battery Deep Discharge Supervised for AC Failure Slide 23 MAXSYS Version 3.3 Access Control Features Up to 32 Readers 1500 Users 64 Access Levels 99 Date Schedules, 4 Interval Each 4 Holiday Groups Scheduled Options Including: Door Unlock REX Input Code Required Door Forced Door Open Too Long Arm Request Disarm Request Slide 24 MAXSYS Version 3.3 Access Control Modules Controller: PC4820 Access Control Module Up to 16 Modules per Panel Each module supports up to 2 Readers Supervised Lock Output Power, 250 mA Inputs: Door Contact, REX, Arm and Postpone Arm Outputs: LED, Buzzer Failsoft Operation Operates if communication is lost with control panel Slide 25 MAXSYS Version 3.3 Access Control Modules Readers: Multiple Reader Technology Support: Polaris ShadowProx HID IoProx Different Technology Readers can be used on one System Slide 26 MAXSYS Version 3.3 Access Control Modules Controller: PC4850 Lobby Controller Apartment Building Entry Control Gate Control Up to 16 Modules per Panel Electronic Directory up to 1500 Users Controls up to 2 Doors Failsoft Operation Operates if communication is lost with control panel Internal 128 Event Buffer PC4851 No Phone Bill Option Slide 27 MAXSYS Version 3.3 Automation Features Telephone Interface Control panel using any touchtone telephone Interface for Power Line (X-10) Devices Intercom Verbal Chime Verbal Alarm Slide 28 MAXSYS Version 3.3 Automation Modules Telephone Interface Escort4580 Telephone Interface Module Turns any Touchtone Telephone into a Talking Keypad Local or Remote Access Multiple Language Available Get Verbal System Status Arm, Disarm and Perform Other User Functions 240 Word Library for Labels (zones, partitions, automation items) Interface for Power Line (X-10) Devices Control up to 32 Automation Devices Slide 29 MAXSYS Version 3.3 Automation Modules Intercom PC4936 Intercom Module 7 Station Intercom Module Indoor and Outdoor (doorbell) Stations Available Features Include Page/Answer, Doorbell, Do not Disturb Supports Central Station Listen-In and Two-Way Expandable to 15 Stations with PC4937 Module When used with Escort4580 Features Include: Verbal Door Chime Verbal Alarm Annunciation Slide 30 MAXSYS Version 3.3 Miscellaneous Features DataLink Bi-Directional RS232 Control Alternate Communications Skyroute T-Link Downloading Slide 31 MAXSYS Version 3.3 DataLink DataLink PC4401 Serial Interface Module Supports Bi-Directional RS232 Control Provides System Integrators with Real-Time Events Panel will send panel status real-time Provides System Integrators with Real-Time Control Commands can be sent to the panel such as arm, disarm and bypass Slide 32 MAXSYS Version 3.3 Cellemetry Communicator SkyrouteMAX Cellemetry Communicator Redundant Alarm Communication via Cellemetry Data Service Uses Control Channel of Existing Cellular Network Connects Directly to Panel COMBUS Can Report all Events by User Code, Zone Fully Supervised Signal Strength Indicator Slide 33 MAXSYS Version 3.3 Network Interface T-Link Module T-Link TCP/IP Module Connects to Panel PCLINK Connector Used on LAN or WAN of User Can be used with Reporter IP Software for Local Reporting Can be used with Sur-Gard Receiver to Report via Network to the Central Station Can be used for End User Downloading Slide 34 MAXSYS Version 3.3 Miscellaneous UL365, UL1635Police station alarm units (Commercial burglary) UL1610, UL1635Central station alarm units (Commercial burglary) UL609, UL1635Local alarm units (Commercial burglary) UL1023Household burglar alarm system units UL985Control units & accessories - Household system UL864Control units system (Commercial Fire) UL294Access control system units UL Listings: CE EN60950; EN50130-4; EN55022 Class B CTR-21 CSFM International Listings: Slide 35 MAXSYS Version 3.3 Summary Secure larger portion of installation One system to learn and maintain Opportunity for post-installation expansion sales Lower system cost + simplified installation = HIGHER PROFITS Third party system integration Dealer Benefits: Product grows with customers changing needs One system to learn - plain language keypads One installer to call = reduced maintenance headaches Most cost-effective multiple system solution Windows-based System Administration Software End User Benefits: