► Vision RV ► Liquid Gas ► Flow ► Water Brand pasquale Hi to all; Posted 31 January 2007 - 11:21 AM

description

hi

Transcript of Max Rhov^2 for Nozzle - Industrial Professionals

1/6/14 Max Rhov̂ 2 For Nozzle - Industrial Professionals - Cheresources.com Community

www.cheresources.com/invision/topic/3417-max-rhov2-for-nozzle/ 1/4

Ch er esou r ces.com Com m u n ity → Gen er a l Ch em ica l En g in eer in g For u m → In du str ia l Pr ofession a ls

0 | More

ChExpressBlog -12/10/13Read the latestnews from the chemicalindustry in Christa's blog.

FeaturedArticlesCheck out thelatest featuredarticles.

File LibraryCheck out thelatestdownloadsavailable in theFile Library .

New ArticleProductViscosity vs.Shear

Featured FileCompressorSettle OutPressure andTemperature

New BlogEntryTimeDependent GasReleaseThrough A Hole From APressurized Container- postedin Ankur's blog

Max Rhov^2 For NozzleStarted by pasquale, Jan 31 2007 1 1 :21 AM

Share this topic:

► Nozzle ► Water Jet Nozzle ► Heat Exchanger ► Rho

► Water Heat Exchanger

► Rho

► Pressure Vessel

ShareShareShareShareShareShareShareMore

► Vision RV ► Liquid Gas ► Flow ► Water Brand

pasquale

Hi to all;

Posted 3 1 Ja n u a r y 2 007 - 1 1 :2 1 A M

1/6/14 Max Rhov̂ 2 For Nozzle - Industrial Professionals - Cheresources.com Community

www.cheresources.com/invision/topic/3417-max-rhov2-for-nozzle/ 2/4

I would like to know if there are general guidelines for the maximum value of rho*v^2 at nozzle equipment (inlet and outlet).

Thanks in advance

muchlis nugroho

Hi,

I usually use 3000 for gas and 1500 for 2-phase in SI unit.

Rgds,

MNG

QUOTE (pasquale @ Jan 31 2007, 11:21 PM) <{POST_SNAPBACK}> (index.php?act=findpost&pid=9654)

Hi to all;

I would like to know if there are general guidelines for the maximum value of rho*v^2 at nozzle equipment (inlet and outlet).

Thanks in advance

Posted 01 Febr u a r y 2 007 - 03 :05 A M

Zauberberg

Hello,

I recall this question has been raised in one of the Eng-Tips threads, followed by discussion about necessity of impingement

plate installation. If this is the subject of your concern, TEMA recommends that inlet impingement protection be installed

under the following conditions:

• When the rho*V2 through the inlet nozzle exceeds 2232 kg/(m*s2) or 1500 lb/(ft*s2) for non-corrosive, non-abrasive,

single phase fluids

• When the rho*V2 through the inlet nozzle exceeds 744 kg/(m*s2) or 500 lb/(ft*s2) for corrosive or abrasive liquids

• When there is a nominally saturated vapor

• When there is a corrosive gas

• When there is two phase flow at the inlet

I guess these numbers can be used as a guideline for maximum Rho*V2 values for equipment nozzles without impingement

baffles.

Posted 01 Febr u a r y 2 007 - 09 :4 2 A M

Art Montemayor

Zauberberg (or Sylvester, as I like to think of him) is on the right trail. If the equipment in question is a shell & tube heat

exchanger, The Standards of the Tubular Exchanger Manufacturrers Association (TEMA) state:

"An impingement plate, or other means to protect the tube bundle against impinging fluids, shall be provided when entrance line

values of rV2 (in lb/ft2-s) exceed the following:

Non-corrosive, non-abrasive, single phase fluids = 1,500

All other liquids, including a liquid at its boiling point = 500

For all other gases and vapors, including all nominally saturated vapors, and for liquid vapor mixtures, impingement protection is

required.

In no case shall the shell or bundle entrance or exit area produce a value of rV2 in excess of 4,000 lb/ft2-s.

Consideration shall be given to the need of special devices to prevent erosion of the tube ends under the following conditions:

Posted 01 Febr u a r y 2 007 - 04 :5 4 PM

1/6/14 Max Rhov̂ 2 For Nozzle - Industrial Professionals - Cheresources.com Community

www.cheresources.com/invision/topic/3417-max-rhov2-for-nozzle/ 3/4

1. Use of an axial inlet nozzle;

2. Liquid rV2 is in excess of 6,000 lb/ft2-s."

Additionally, the NorSok P-100 Process Standards for Offshore applications state:

"Typically the following maximum inlet momentum for the inlet stream should be used on scrubbers:

No inlet device: rV2 <= 1,000 kg/m2s

Half pipe: rV2 <= 1,500 kg/m2s

Inlet vane: rV2 <= 6,000 kg/m2s"

Pasquale has not revealed what type of equipment he is referring to and all we can do is guess. We need specifics basic data in

order to generate specific, correct answers to the query.

pasquale

I have a xilenes splitter and I would like to know the maximum value of rho*v^2 on the vapor line nozzle (top of column) and

for the nozzle that joints the reboiler (it's a furnace in my case) with the column.

this line is very critical in our design because there is two-phases flow (I have checked there is a spray flow). The size is

30inch then near the column there is an enlargement to 48 inch (so nozzle column is 48 inch).

I'm checking the hydraulics of this system but the mixed phase 30 inch line has a

value of rho*v^2 of 18500 Pa that seems too high for me.

Maybe it's better to change the diameter of this line ?

Any comments is appreciate

Pasquale

Posted 02 Febr u a r y 2 007 - 02 :1 7 A M

process equipment

hi.

i'm kind of confusing which r-v-sq to use from TEMA:

RCB-4.61 shell side impingement protection

RCB-4.62 shell or bundle entrance and exit

RCB-4.63 tube side

which one should be taken into account (design criterion) ?

thanks

Posted 02 Febr u a r y 2 007 - 07 :5 5 A M

muchlis nugroho

Hi,

Seems that I should revise my standard.

Rgds,

MNG

Posted 06 Febr u a r y 2 007 - 09 :09 PM

[email protected]

Hi all...

I have some enquiries regarding the momentum criterion for nozzle in separator (2 phases).

If we look to the DEP, the pv2 value is pv2>2100. May I know how this 2100 value is derived... is there any method to

Posted 1 2 Ma y 2 009 - 09 :3 8 PM

1/6/14 Max Rhov̂ 2 For Nozzle - Industrial Professionals - Cheresources.com Community

www.cheresources.com/invision/topic/3417-max-rhov2-for-nozzle/ 4/4

Back to Industrial Professionals · Next Unread Topic →

Ch er esou r ces.com Com m u n ity → Gen er a l Ch em ica l En g in eer in g For u m → In du str ia l Pr ofession a ls

Nozzle

Started by Guest_Atul Jain_25382_* , 06 Dec 201 3

0 replies21 6 v iews

06 Dec 201 3

Tank Outlet Nozzle Location

Started by Guest_sunny 1 43_* , 04 Dec 201 3

8 replies

226 v iews

05 Dec 201 3

Shell Side Nozzle Location

Started by Guest_WilliamN_* , 21 Oct 201 3

0 replies

288 v iews

21 Oct 201 3

Steam Out Nozzle Connection

Started by Guest_zahraniazi_* , 25 Aug 201 3

6 replies

547 v iews

31 Aug 201 3

Nozzle Sizing For Produced Water Tank

Started by Guest_Manoj.Selv araj_* , 24 Aug 201 3

2 replies

51 9 v iews

24 Aug 201 3

determine it? how they get that value...what happen if the pv2 is exceeded the max value...please kindly advice and thank

you for helping.

HEY SORRY AGAIN FOR JUNPING IN BETWEEN

TEMA SPECIFIES THE VALUE OF ROWV2 VALUE ABOUT 2200 THATS TRUE, DOES ANY ONE KNOW WHAT VALUE

DOSE HEI CODES CONVEY.

CERTAINLY I BELIEVE IT WILL BE VERY HIGH BUT DONT KNOW EXACTLY IF ANY ONE CAN GET IT.

Posted 1 3 Ma y 2 009 - 01 :1 9 A M