Max Rhov^2 For NozzleStarted by pasquale, Jan 31 2007 1 1 :21 AM
Share this topic:
► Nozzle ► Water Jet Nozzle ► Heat Exchanger ► Rho
► Water Heat Exchanger
► Rho
► Pressure Vessel
ShareShareShareShareShareShareShareMore
► Vision RV ► Liquid Gas ► Flow ► Water Brand
pasquale
Hi to all;
Posted 3 1 Ja n u a r y 2 007 - 1 1 :2 1 A M
1/6/14 Max Rhov̂ 2 For Nozzle - Industrial Professionals - Cheresources.com Community
www.cheresources.com/invision/topic/3417-max-rhov2-for-nozzle/ 2/4
I would like to know if there are general guidelines for the maximum value of rho*v^2 at nozzle equipment (inlet and outlet).
Thanks in advance
muchlis nugroho
Hi,
I usually use 3000 for gas and 1500 for 2-phase in SI unit.
Rgds,
MNG
QUOTE (pasquale @ Jan 31 2007, 11:21 PM) <{POST_SNAPBACK}> (index.php?act=findpost&pid=9654)
Hi to all;
I would like to know if there are general guidelines for the maximum value of rho*v^2 at nozzle equipment (inlet and outlet).
Thanks in advance
Posted 01 Febr u a r y 2 007 - 03 :05 A M
Zauberberg
Hello,
I recall this question has been raised in one of the Eng-Tips threads, followed by discussion about necessity of impingement
plate installation. If this is the subject of your concern, TEMA recommends that inlet impingement protection be installed
under the following conditions:
• When the rho*V2 through the inlet nozzle exceeds 2232 kg/(m*s2) or 1500 lb/(ft*s2) for non-corrosive, non-abrasive,
single phase fluids
• When the rho*V2 through the inlet nozzle exceeds 744 kg/(m*s2) or 500 lb/(ft*s2) for corrosive or abrasive liquids
• When there is a nominally saturated vapor
• When there is a corrosive gas
• When there is two phase flow at the inlet
I guess these numbers can be used as a guideline for maximum Rho*V2 values for equipment nozzles without impingement
baffles.
Posted 01 Febr u a r y 2 007 - 09 :4 2 A M
Art Montemayor
Zauberberg (or Sylvester, as I like to think of him) is on the right trail. If the equipment in question is a shell & tube heat
exchanger, The Standards of the Tubular Exchanger Manufacturrers Association (TEMA) state:
"An impingement plate, or other means to protect the tube bundle against impinging fluids, shall be provided when entrance line
values of rV2 (in lb/ft2-s) exceed the following:
Non-corrosive, non-abrasive, single phase fluids = 1,500
All other liquids, including a liquid at its boiling point = 500
For all other gases and vapors, including all nominally saturated vapors, and for liquid vapor mixtures, impingement protection is
required.
In no case shall the shell or bundle entrance or exit area produce a value of rV2 in excess of 4,000 lb/ft2-s.
Consideration shall be given to the need of special devices to prevent erosion of the tube ends under the following conditions:
Posted 01 Febr u a r y 2 007 - 04 :5 4 PM
1/6/14 Max Rhov̂ 2 For Nozzle - Industrial Professionals - Cheresources.com Community
www.cheresources.com/invision/topic/3417-max-rhov2-for-nozzle/ 3/4
1. Use of an axial inlet nozzle;
2. Liquid rV2 is in excess of 6,000 lb/ft2-s."
Additionally, the NorSok P-100 Process Standards for Offshore applications state:
"Typically the following maximum inlet momentum for the inlet stream should be used on scrubbers:
No inlet device: rV2 <= 1,000 kg/m2s
Half pipe: rV2 <= 1,500 kg/m2s
Inlet vane: rV2 <= 6,000 kg/m2s"
Pasquale has not revealed what type of equipment he is referring to and all we can do is guess. We need specifics basic data in
order to generate specific, correct answers to the query.
pasquale
I have a xilenes splitter and I would like to know the maximum value of rho*v^2 on the vapor line nozzle (top of column) and
for the nozzle that joints the reboiler (it's a furnace in my case) with the column.
this line is very critical in our design because there is two-phases flow (I have checked there is a spray flow). The size is
30inch then near the column there is an enlargement to 48 inch (so nozzle column is 48 inch).
I'm checking the hydraulics of this system but the mixed phase 30 inch line has a
value of rho*v^2 of 18500 Pa that seems too high for me.
Maybe it's better to change the diameter of this line ?
Any comments is appreciate
Pasquale
Posted 02 Febr u a r y 2 007 - 02 :1 7 A M
process equipment
hi.
i'm kind of confusing which r-v-sq to use from TEMA:
RCB-4.61 shell side impingement protection
RCB-4.62 shell or bundle entrance and exit
RCB-4.63 tube side
which one should be taken into account (design criterion) ?
thanks
Posted 02 Febr u a r y 2 007 - 07 :5 5 A M
muchlis nugroho
Hi,
Seems that I should revise my standard.
Rgds,
MNG
Posted 06 Febr u a r y 2 007 - 09 :09 PM
Hi all...
I have some enquiries regarding the momentum criterion for nozzle in separator (2 phases).
If we look to the DEP, the pv2 value is pv2>2100. May I know how this 2100 value is derived... is there any method to
Posted 1 2 Ma y 2 009 - 09 :3 8 PM
1/6/14 Max Rhov̂ 2 For Nozzle - Industrial Professionals - Cheresources.com Community
www.cheresources.com/invision/topic/3417-max-rhov2-for-nozzle/ 4/4
Back to Industrial Professionals · Next Unread Topic →
Ch er esou r ces.com Com m u n ity → Gen er a l Ch em ica l En g in eer in g For u m → In du str ia l Pr ofession a ls
Nozzle
Started by Guest_Atul Jain_25382_* , 06 Dec 201 3
0 replies21 6 v iews
06 Dec 201 3
Tank Outlet Nozzle Location
Started by Guest_sunny 1 43_* , 04 Dec 201 3
8 replies
226 v iews
05 Dec 201 3
Shell Side Nozzle Location
Started by Guest_WilliamN_* , 21 Oct 201 3
0 replies
288 v iews
21 Oct 201 3
Steam Out Nozzle Connection
Started by Guest_zahraniazi_* , 25 Aug 201 3
6 replies
547 v iews
31 Aug 201 3
Nozzle Sizing For Produced Water Tank
Started by Guest_Manoj.Selv araj_* , 24 Aug 201 3
2 replies
51 9 v iews
24 Aug 201 3
determine it? how they get that value...what happen if the pv2 is exceeded the max value...please kindly advice and thank
you for helping.
HEY SORRY AGAIN FOR JUNPING IN BETWEEN
TEMA SPECIFIES THE VALUE OF ROWV2 VALUE ABOUT 2200 THATS TRUE, DOES ANY ONE KNOW WHAT VALUE
DOSE HEI CODES CONVEY.
CERTAINLY I BELIEVE IT WILL BE VERY HIGH BUT DONT KNOW EXACTLY IF ANY ONE CAN GET IT.
Posted 1 3 Ma y 2 009 - 01 :1 9 A M