Matti Pajari Prestressed hollow core slabs supported on beams ...

675
Matti Pajari Prestressed hollow core slabs supported on beams Finnish shear tests on floors in 1990–2006 VTT WORKING PAPERS 148

Transcript of Matti Pajari Prestressed hollow core slabs supported on beams ...

Page 1: Matti Pajari Prestressed hollow core slabs supported on beams ...

Matti Pajari

Prestressed hollow core slabs supported on beams

Finnish shear tests on floors in 1990–2006

VTT WORKING PAPERS 148

Page 2: Matti Pajari Prestressed hollow core slabs supported on beams ...

ISBN 978-951-38-7495-7 (URL: http://www.vtt.fi/publications/index.jsp) ISSN 1459-7683 (URL: http://www.vtt.fi/publications/index.jsp)

Copyright © VTT 2010

JULKAISIJA – UTGIVARE – PUBLISHER

VTT, Vuorimiehentie 5, PL 1000, 02044 VTT puh. vaihde 020 722 111, faksi 020 722 4374

VTT, Bergsmansvägen 5, PB 1000, 02044 VTT tel. växel 020 722 111, fax 020 722 4374

VTT Technical Research Centre of Finland, Vuorimiehentie 5, P.O. Box 1000, FI-02044 VTT, Finland phone internat. +358 20 722 111, fax +358 20 722 4374

Page 3: Matti Pajari Prestressed hollow core slabs supported on beams ...

Series title, number and report code of publication

VTT Working Papers 148 VTT-WORK-148

Author(s) Matti Pajari

Title

Prestressed hollow core slabs supported on beams Finnish shear tests on floors in 1990–2006

Abstract

Arrangements and results of 20 full-scale load tests on floors, each made of eight to twelve prestressed hollow core slabs and three beams, are presented. The tests have been carried out by VTT Technical Research Centre of Finland and Tampere University of Technology.

ISBN 978-951-38-7495-7 (URL: http://www.vtt.fi/publications/index.jsp)

Series title and ISSN Project number

VTT Working Papers 1459-7683 (URL: http://www.vtt.fi/publications/index.jsp)

Date Language Pages November 2010 English 674 p.

Name of project Commissioned by Querkraftfähigkeit von Spannbeton-Fertigdecken bei biegeweicher Lagerung

Institut für Massivbau der RWTH Aachen

Keywords Publisher Prestress, hollow core slab, flexible support, shear resistance, floor test, composite construction, concrete

VTT Technical Research Centre of Finland P.O. Box 1000, FI-02044 VTT, Finland Phone internat. +358 20 722 4520 Fax +358 20 722 4374

Page 4: Matti Pajari Prestressed hollow core slabs supported on beams ...

4

Preface

The reduction of the shear resistance of hollow core slabs due to deflection of the sup-porting beams has been studied since 1990. Despite numerous tests, theoretical and nu-merical analyses and international cooperation, no common European understanding about the reasons of and solutions for this phenomenon has been achieved. A German research project “Querkrafttragfähigkeit von Spannbeton-Fertigdecken bei biegewei-cher Lagerung”, recently completed at Institut für Massivbau, Rheinisch-Westfälische Technische Hochschule, Aachen, aimed to be a step to that direction. The present report has been elaborated as a part of this project.

All reported tests have been performed in confidential projects and commissions. The owners of the results mentioned in the report have permitted the publication of all relevant data and paid the costs of the information service, which is gratefully acknowledged.

The work has financially been supported by the research team in Aachen, i.e. Prof. Hegger, Dr. Roggendorf and their coworkers. Without their contribution it would not have been possible to realise the work. Special thanks are due to them for their patience in waiting for the completion of the report and for the kind and encouraging atmosphere before, during and after the project.

Page 5: Matti Pajari Prestressed hollow core slabs supported on beams ...

5

Contents

Preface ........................................................................................................................... 4

Meaning of abbreviations................................................................................................ 6

1. Introduction ............................................................................................................... 7

2. Summary................................................................................................................... 8

3. Shear tests on floors ................................................................................................. 9

VTT.CR.Delta.265.1990........................................................................................................ 11

VTT.S.WQ.265.1990............................................................................................................. 33

VTT.PC.InvT.265.1990 ......................................................................................................... 73

VTT.PC.InvT.400.1992 ....................................................................................................... 101

VTT.S.WQ.400.1992........................................................................................................... 133

VTT.PC.InvT-Unif.265.1993................................................................................................ 163

VTT.PC.InvT-Topp.265.1993 .............................................................................................. 199

VTT.PC.Rect-norm.265.1993.............................................................................................. 231

VTT.PC.InvT_Cont.265.1994.............................................................................................. 263

TUT.CR.MEK.265.1994 ...................................................................................................... 293

VTT.RC.Rect-norm.265.1994 ............................................................................................. 317

VTT.CP.LBL.320.1998 ........................................................................................................ 347

VTT.CR.Delta.400.1999...................................................................................................... 375

VTT.CP.Super.320.2002..................................................................................................... 413

TUT.CP.LB.320.2002.......................................................................................................... 443

VTT.S.WQ.500.2005........................................................................................................... 467

VTT.PC.InvT.500.2006 ....................................................................................................... 525

VTT.CR.Delta.500.2005...................................................................................................... 563

VTT.PC.InvT.400.2006 ....................................................................................................... 613

VTT.CR.A-beam.320.2006.................................................................................................. 639

Page 6: Matti Pajari Prestressed hollow core slabs supported on beams ...

6

Meaning of abbreviations

VTT Technical Research Centre of Finland

TUT Tampere University of Technology

PC Prestressed concrete beam

RC Reinforced concrete beam

S Steel beam

CP Composite, prestressed beam

CR Composite reinforced beam

WQ Top-hat steel beam

InvT Inverted T-beam (concrete)

Rect Rectangular beam (concrete)

A-beam, Delta, MEK, LB, LBL, Super Patented composite beams

Unif Uniformly distributed load over half floor

Topp Reinforced concrete topping

Norm Normal support (slabs on the top of the beam)

Cont Continuous beam

Page 7: Matti Pajari Prestressed hollow core slabs supported on beams ...

7

1. Introduction

The effect of flexible supports, i.e. reduction of the shear resistance of the hollow core slabs due to deflection of the supporting beams, has been experimentally studied since 1990. The results and analysis of ten tests carried out by VTT, Finland, have been pub-lished previously. Due to these tests and parallel tests performed elsewhere it has be-come clear that the reduction of the shear resistance has to be taken into account in design.

European standard EN 1168. Precast concrete products. Hollow core slabs has been amended by a sentence stating that the effect of flexible supports on the shear resistance shall be taken into account. How this can be done, is not specified. Therefore, national design rules, if any, are applied to meet this requirement. It is obvious that a European design method has to be developed, but this is not only a question of standardisation; research is also needed.

In 2005, a research project dealing with the effects of flexible supports was started at RWTH, Aachen. New floor tests were performed, but the results of the former Finnish and German tests were also considered. As a part of the project, the test arrangements and results of twenty Finnish floor tests in 1990–2006 have been elaborated and pub-lished in this report. The aim has been to provide experimental data which can be re-ferred to when writing scientific papers or when developing and standardizing European design rules. No analysis of the results is presented. The aim has also been to make the data so complete that there is no need to read the original test reports, five of which have been written in Finnish. Some tabulated characteristics of the tests are given on the first page. The rest of the report is divided in 20 Chapters, each including the results on one floor test and the related reference tests.

The German test results are available at

http://www.imb.rwth-aachen.de/Weitere-Informationen/ (Titel „Zum Tragverhalten von Spannbeton-Fertigdecken bei biegeweicher Lagerung“)

Page 8: Matti Pajari Prestressed hollow core slabs supported on beams ...

8

2. Summary

Basic data about the tests are given in Table 1.

Table 1. Thickness of slabs (hslab), length of core filling (Lfill), span of beams (L), length of slabs (Lslab), shear resistance / one slab in floor test (Vobs), mean of shear resistances observed in reference tests (Vref) and last measured deflection of the middle beam before failure ().

Test hslab

mm Lfill

mmL

m Lslab

m Vobs

kN Vref

kN ref

obs

V

V 1)

mm

L/

VTT.CR.Delta.265.1990 265 50 5,0 6,0 114,6 283,9 0,40 16,3 307

VTT.S.WQ.265.1990 265 50 5,0 6,0 166,1 230,5 0,72 17,6 284

VTT.PC.InvT.265.1990 265 50 5,0 6,0 103,4 230,5 0,45 9,9 505

VTT.PC.InvT.400.1992 400 320 5,0 7,2 252,1 490,3 0,51 5,42) 926

VTT.S.WQ.400.1992 400 30 5,0 7,2 293,6 516,3 0,57 14,6 342

VTT.PC.InvT-Unif.265.1993 265 185 5,0 6,0 147,6 251,8 0,59 39 128

VTT.PC.InvT-Topp.265.1993 265 50 5,0 6,0 140,3 193,6 0,72 13,8 362

VTT.PC.Rect-Norm.265.1993 265 50 5,0 6,0 163,8 210,9 0,78 7,7 649

VTT.PC.InvT-Cont.265.1994 265 50 5,0 6,0 191,4 194,6 0,98 5,2 962

TUT.CR.MEK.265.1994 265 50 5,02 6,0 148,2 223,2 0,66 16,7 301

VTT.RC.Rect-Norm.265.1994 265 50 7,2 6,0 106,7 226,2 0,47 30,3 238

VTT.CP.LBL.320.1998 320 50 5,0 7,2 161,9 295,3 0,55 20,9 240

VTT.CR.Delta.400.1999 400 50 5,0 8,4 222,0 419,5 0,53 24 208

VTT.CP.Super.320.2002 320 250 4,8 9,6 127,5 242,8 0,53 17,5 274

TUT.CP.LB.320.2002 320 50 4,8 7,2 149,2 313,3 0,48 21,3 225

VTT.S.WQ.500.2005 500 400 7,2 10,0 269,6 650,7 0,41 21,2 340

VTT.PC.InvT.500.2005 500 400 7,2 10,0 336,4 547,1 0,61 21,8 330

VTT.CR.Delta.500.2005 500 400 7,2 10,0 366,9 529,4 0,69 25,7 280

VTT.PC.InvT.400.2006 400 50 4,8 9,0 282,4 332,7 0,85 6,2 774

VTT.CR.A-beam.320.2006 320 50 4,8 8,0 183,3 284,0 0,65 20,9 2301) Last measured deflection before failure 2) Deflection at failure > 5,4 mm and < 7,2 mm

Page 9: Matti Pajari Prestressed hollow core slabs supported on beams ...

9

3. Shear tests on floors

Page 10: Matti Pajari Prestressed hollow core slabs supported on beams ...

10

Page 11: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

11

1 General information

1.1 Identification and aim

VTT.CR.Delta.265.1990

Last update 2.11.2010

DE265 (Internal identification)

Aim of the test To test the interaction between Delta beam and hollow core slabs.

1.2 Test type

Fig. 1. Illustration of test setup. Delta beam in the middle, steel I-beams at the ends.

1.3 Laboratory & date of test

VTT/FI 6.9.1990

1.4 Test report (in Finnish)

Author(s) Koukkari, H.

Name Deltapalkin ja ontelolaataston koekuormitus (Load test on Delta beam and hollow core floor) (in Finnish)

Ref. number RAT01814/90

Date 17.9.1990

Availability Confidential, owner is Peikko Group Oy, P.O. Box 104, FI-15101 Lahti, Finland

2 Test specimen and loading

2.1 General plan

Fig. 2. View on test arrangements.

Page 12: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

12

Fig. 3. Plan. Beams 1) were 1,2 m long cuts of railway rails, There was a small gap between the ends of consecutive cuts. The beams between beams 1) and 2) were also cuts of railway rails. Beams 2) were 1,5 m long steel I-profiles. Measures to eliminate the friction between the stacking steel beams were considered unnecessary.

Fig. 4. Plan and section A-A.

2.2 End beams

200

200

HE 200 B

9 15

15

Fig. 5. End beam.

Page 13: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

13

2.3 Middle beam

The middle beam, see Figs 6–8, comprised - a prefabricated steel component made of a top plate, bottom plate and two folded and

perforated web plates - a cast-in-situ part of concrete K30 which filled the empty space between the slab ends

laying on the ledges of the web plates. The concrete was cast by VTT in laboratory, 24.8.1990. Structural steel: Raex, see 9.1

Fig. 6. Middle beam. Cross-section and tie reinforcement (hooks made of rebars T16) for anchoring of slabs to the beam. Depth of beam = 265 mm + 6 mm.

315Holes 150 300300

220

70

Fig. 7. Middle beam. Position of holes in the webs. South end.

2.4 Arrangements at middle beam

- Simply supported, span = 5,0 m - Note the nonsymmetric position of the beam with respect to the supports (Fig. 7). Such

a displacement was necessary because there was no web hole in the mid-point of the beam. The tie reinforcement had to be anchored both to the longitudinal joints between adjacent hollow core units and to the beam through the web holes.

Tie reinforcement: - perpendicular to the beam: 3x(1+1) hooks T16 of the type shown in Fig. 6, anchored to

the longitudinal joints of the slabs and inside the beam - parallel to the beam: In the cast-in-situ concrete, parallel to the Delta beam and

between the edges of the beam and the slab ends, there were two straight rebars T8, 4,75 m long, one on each side of the beam, see Fig. 8.

Page 14: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

14

Fig. 8. Middle beam. One end of the Delta beam was free to move in beam’s direction.

60 490

60

Fig. 9. Cast-in-situ concrete within and outside middle beam. Note the tie bars T8.

2.5 Slabs

1200

35

185

40

40223 223

265

223223152 152

1160

Fig. 10. Nominal geometry of slab units.

- Extruded by Partek Oy, Nastola factory, grade of concrete K60 - 10 lower strands J12,5 initial prestress 1100 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2m see 9.1 for the strength.

2.6 Temporary supports

No temporary supports below beams.

2.7 Loading arrangements

See Fig. 11. There was a gypsum layer between the tertiary beams and the top surface of the slabs. The primary spreader beams were in direct contact with the secondary spreader beams and the secondary beams with the tertiary spreader beams. No attempts were made to eliminate the friction. For this reason it is difficult to evaluate exactly, to which extent the spreader beams participated to the load-carrying mechanism.

Page 15: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

15

10

00(f

rom

sla

b en

d)

432A

A A

1

600

P

49

0 1

000

P P

1 1 1 1

600 600 600 600 600 600 600

8765 N

orth

So

uth

11

11

11

11

A

B

B

B B

P

PP

PPrimary

Secondary

Tertiary

Load cells

Fig. 11. Loading arrangement with three layers of spreader beams.

Fig. 12. Arrangements at South end of Delta beam.

Page 16: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

16

3 Measurements

3.1 Support reactions

The support reaction of the middle beam due to the actuator loads 4P was measured by load cells below the South end of the middle beam. See Figs 8 and 11. Due to the eccentric position of the concrete slabs with respect to the supports of the middle beam, the support reaction below the North end was roughly = 1,08 times the support reaction below the South end where the reaction was measured.

3.2 Vertical displacement

Fig. 13. Location of transducers 1 … 29 for measuring vertical deflection as well as the location of transducers 30 (measuring differential horizontal displacement between slab edge and Delta beam) and 31 (measuring vertical diff. displacement between slab end and middle beam).

3.3 Average strain

Not measured

3.4 Horizontal. displacements

See Fig. 13 for the only horizontal transducer 30.

3.5 Strain There were strain gauges for measuring the steel strain in the Delta beam, both parallel

to the beam and in transverse direction at the bottom surface of the ledges. Two strain gauges were glued to the top surface of the top plate and two to the bottom surface of the bottom plate, all four parallel to the beam.

The soffit and top surface of the hollow core slabs were also provided with strain gauges in order to measure the strain parallel to the Delta beam. The position of all strain gauges is given in Fig. 14.

Page 17: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

17

Fig. 14. Position of strain gauges. a) Bottom surface of the ledges of Delta beam, gauges 1–10. b) On the bottom and top flange of Delta beam (gauges 11, 12, 23 and 24) and on the hollow core slabs (13–22).

4 Special arrangements

-

5 Loading strategy

5.1 Load-time relationship

Before starting the test, all measuring devices were zero-balanced. Thereafter, the actuator loads P were cyclically varied in such a way that three cycles of the type 0 43,2 kN 0 were followed by two cycles of the type 0 86,4 kN 0 (Stage I) wherafter P was monotonously increased to failure (Stage II).

5.2 After failure

6 Observations during loading

Stage I At P = 38,8 kN longitudinal cracks appeared in the joint concrete along the Delta beam close to the supports of the beam. The cracks grew both in length and width with increasing load.

Stage II At P = 210 kN, the first inclined crack appeared at the edge of slab 4 near the support. Before failure there was an inclined crack at the outermost edge of slabs 1, 4, 5 and 8. At P = 240 kN slab 1 failed along an inclined crack as shown in Fig. 17. This was followed by the failure of all slabs on the same side of the Delta beam. The failure patterns are illustrated in Figs 15–22.

After failure

7 Cracks in concrete

In the following figures, the numbers refer to the value of the actuator loads P in kN.

7.1 Cracks at service load

See Fig. 15.

Page 18: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

18

7.2 Cracks after failure

Fig. 15. Cracks on the top and on the edges of the floor after failure.

Fig. 16. Cracks in the soffit after failure.

Page 19: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

19

Fig. 17. Slab 1 after failure.

Fig. 18. Top surface of slabs 1 (on the left), 2 and 3 after failure.

Page 20: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

20

Fig. 19. Slab 4 after failure.

Fig. 20. Top surface of slabs 4 (on the right) and 3 after failure.

Page 21: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

21

Fig. 21. Slab 8 after failure.

Fig. 22. Soffit of slabs 1–4 after failure.

8 Observed shear resistance

The measured support reaction vs. the total imposed actuator load is depicted in Fig. 23. This relationship and the known eccentricity of the slabs and loads with respect to the beam supports have been used when calculating the observed shear resistance of the slabs.

Page 22: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

22

Fig. 23. Total imposed actuator load vs. support reaction of middle beam. South end. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + V

where Vg,sl, Vg,jc, Veq and VP are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P, respectively. The test report does not give all these components but the sum

Veq + VP = 101,9 kN which is based on measured support reaction below one end of the middle beam and on the geometry of the test specimen. The self weight of the loading equipment was 420 kg/ one actuator. From this, Veq = 1,8 kN is obtained. Hence VP = 100,1 kN. From the measured density of the concrete and nominal geometry

Vg,sl + Vg,jc = 12,3 + 0,4 kN = 12,7 kN follows. The shear resistance Vobs = 114,6 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear resistance per unit width is vobs = 95,5 kN/m

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

Delta beam - web plates - top plate - bottom plate

355 390 390

Nominal (Raex 37-52) Nominal (Raex 423) Nominal (Raex 423)

End beams 350 Nominal (Fe52) Slab strands J12,5 1570–1630 1770–1860 Nominal (no yielding in test) Reinforcement Txy 500 Nominal value for reinforcing bars

(no yielding in test)

Page 23: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

23

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

12 50 50 6.9.1990 Upper flange of slabs 1–4. 3 from each, = 2393 kg/m3

Mean strength [MPa] 74,2 (0 d)1) Vertically drilled St.deviation [MPa] 6,2 Tested as drilled2)

9.3 Strength of slab concrete, reference tests

Not measured, assumed to be the same as that in the floor test

9.4 Strength of cast-in-situ concrete

#

a

a

a

a mm

Date of test

Note

3 150 31.8.1990 Kept in laboratory in the same Mean strength [MPa] 33,8 (-6 d)1) conditions as the floor specimen St.deviation [MPa] - = 2247 kg/m3

1) Date of material test minus date of structural test (floor test or reference test) 2) After drilling, kept in a closed plastic bag until compression

10 Measured displacements and strains

In the following figures, P stands for the actuator force plus load due to loading equipment per one actuator. The cylic stage (Stage I) is not shown. The first point on each curve corresponds to the start of the monotonous loading stage (Stage II). Due to the abrupt failure, the measured results at the last load step are missing.

10.1 Deflections

Fig. 24. Mid-point deflection of middle beam (transducer 15) and end beams (transducers 1 and 29).

Page 24: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

24

Fig. 25. Deflection of middle beam measured by transducers 12–17.

Fig. 26. Deflection of slabs 1–4 measured by transducers 2–6.

Page 25: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

25

Fig. 27. Deflection of slabs 1–4 measured by transducers 7–11.

Fig. 28. Deflection of slabs 5–8 measured by transducers 19–22.

Page 26: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

26

Fig. 29. Deflection of slabs 5–8 measured by transducers 24–28.

Fig. 30. Deflection along longitudinal line of symmetry measured by transducers 1, 4, 9, 15, 21, 26 and 29.

10.3 Average strain

-

Page 27: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

27

10.4 Differential displacement

Fig. 31. Differential vertical displacement between middle beam and end of slab 7 measured by transducer 31.

Fig. 32. Differential horizontal displacement between middle beam and edge of slab 4 measured by transducer 30.

Page 28: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

28

10.5 Strain

Fig. 33. Longitudinal (gauge 4) and transverse strain (gauges 1–3 and 5–7) measured at the bottom surface of the ledge of Delta beam.

Fig. 34. Longitudinal (gauge 9) and transverse strain (gauges 8 and 10) measured at the bottom surface of the ledge of Delta beam.

Page 29: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

29

Fig. 35. Strain parallel to the beam

- on the top surface (gauges 19 and 20) and on the bottom surface (gauges 21 and 22) of the hollow core slabs

- on the top surface of the top plate (gauge 23) and on the bottom surface of the bottom plate of the Delta beam (gauge 12).

Fig. 36. Strain parallel to the beam

- on the top surface (gauges 13–15) and on the bottom surface (gauges 16–18) of the hollow core slabs

- on the top surface of the top plate (gauge 24) and on the bottom surface of the bottom plate of the Delta beam (gauge 11).

The tensile strain of the order 0,001 measured at the bottom of the bottom plate and in the ledges of the Delta beam confirm that the steel in the beam was far from yielding.

Page 30: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

30

11 Reference tests

After the load test on the floor, slabs 3 and 7 were taken as reference test specimens. Their ends which had been supported by the end beams, where loaded in shear as shown in Fig. 37. The concrete tie beam partly outside the slab end, partly in the hollow cores, was not removed before loading.

Fig. 37. Layout of reference test. For Lj, see the next table. Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure + weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span

mm

Vg

kN

Pa+Peq

kN

Va+eq

kN

Vobs

kN

vobs

kN/m Note

R3 >6.9.1990 4938 10,3 348,5 277,9 288,2 240,2 Web shear failure

R7 >6.9.1990 4810 10,0 340,4 269,6 279,6 233,0 Web shear failure

Mean 283,9 236,6

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 114,6 kN per one slab unit or 95,5 kN/m. This is 40% of the mean of the shear resistances observed in the reference tests.

Page 31: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.265.1990

31

13 Discussion

1. The span of the middle beam was 5,0 m; that of the end beams 4,9 m.

2. The friction between the spreader beams was not intentionally eliminated, which may have affected the response of the floor test specimen to some extent.

3. The failure took place at an unexpected low load level. Therefore, the load increments applied were still relatively big and the gap between the failure load, at which no measurements were made, and the proceeding load level at which the response was measured, was big, too. The conclusions below about the strains and deflections at failure are based on the extrapolation of the measured curves.

4. At failure, the net deflection of the middle beam due to the imposed actuator loads (deflection minus settlement of supports) was 16,3 mm or L/307, i.e. rather small. It was 3,5–4,3 mm greater than that of the end beams. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a minor effect, if any, on the failure of the slabs.

5. The shear resistance measured in the reference tests was higher than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005. This difference may be attributable to the concrete tie beam at the edge of the sheared end in the reference test. It prevented the deformation of the end section of the slab and thus equalized the strains in the webs of the slab, which effectively eliminated the premature failure of any individual web.

6. The beams did not yield in the floor test.

7. The failure mode was web shear failure of edge slabs close to the supports of the middle beam. Unlike in an isolated hollow core slab unit, the appearance of the first inclined crack close to the slab end did not mean failure but the loads could still be increased.

Page 32: Matti Pajari Prestressed hollow core slabs supported on beams ...

32

Page 33: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

33

1 General information

1.1 Identification and aim

VTT.S.WQ.265.1990 Last update 2.11.2010

WQ265 (Internal identification).

Note that the top-hat steel beam was called HQ-beam when the floor test was carried out, but later on the name has been changed. The present name WQ-beam is used in the following

Aim of the test To study whether or not the shear resistance of the hollow core slabs is reduced when supported on a WQ-beam

1.2 Test type

WQ-beam

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 11.10.1990

1.4 Test report Author(s) Koukkari, H.

Name Matalien leukapalkkien ja ontelolaataston kuormituskokeet (Load tests on shallow beams and hollow core floor), in Finnish

Ref. number RAT01839/90

Date 19.11.1990

Availability Confidential, owner is Rautaruukki Oyj, P.O. Box 35, FI-01531 Vantaa, Finland

Page 34: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

34

2 Test specimen and loading

2.1 General plan

Fig. 2. Overview on arrangements.

Page 35: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

35

Fig. 3. Plan and longitudinal section along joint between adjacent slab units. Note the suspension reinforcement 3T8 c/c 1200 in the longitudinal joints of slabs and rebars (1+2+1)T8 tying the slab ends at the ends of the specimen and on both sides of the WQ-beam.

T8: Hot rolled, weldable rebar A500HW, = 8 mm

Page 36: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

36

2.2 End beams

Fig. 4. End beam.

- Simply supported, span = 5,0 m - There was plywood between the slabs and the end beam, see also Fig. 3 - Structural steel: Fe 52, fy 350 MPa (nominal fy)

2.3 Middle beam

The beam was designed to carry the support reactions from the slabs, slightly lower than those corresponding to the estimated shear resistance of the slab ends. The beam was made by PPTH-Teräs Oy and delivered to VTT on the 8th of August 1990. The measured camber of the beam was 12,7 mm.

Fig. 5. WQ-beam. Structural steel: Fe 52C, fy 350 MPa (nominal fy)

2.4 Arrangements at middle beam

- Simply supported, span = 5,0 m - 4 load cells below support at South end - bearing length of slabs = 60 mm - see Fig. 3 for the bar reinforcement across the beam and parallel to it - joint concrete cast 27.9.1990

Page 37: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

37

2.5 Slabs

1200

35

185

40

40223 223

265

223223152 152

1160

Fig. 6. Nominal geometry of slab units.

- Extruded by Parma Oy 29.6.1990 - delivered to VTT, 12.9.1990 - grade of concrete K60 - 10 lower strands J12,5; initial prestress 1100 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

2.6 Temporary supports

-

2.7 Loading arrangements

See Fig. 7. There was a gypsum layer between the tertiary beams and the top surface of the slabs. The primary spreader beams were in direct contact with the secondary spreader beams and the secondary beams with the tertiary spreader beams. No attempts were made to eliminate the friction. For this reason it is difficult to evaluate, to which extent the spreader beams participated in the load-carrying mechanism.

Page 38: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

38

10

00(f

rom

sla

b en

d)

432A

A A

1

600

P

49

0 1

000

P P

1 1 1 1

600 600 600 600 600 600 600

8765

Nor

th

So

uth

11

11

11

11

A

B

B

B B

P

PP

PPrimary

Secondary

Tertiary

Load cells

Fig. 7. Loading arrangements with three layers of spreader beams. The joint concrete between the slab ends and middle beam was extended to the ends of the WQ-beam.

Page 39: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

39

3 Measurements

3.1 Support reactions

There were four load cells below the South end of the WQ-beam for measuring the support reaction due to the actuator loads.

3.2 Vertical displacement

Fig. 8. Location of transducers 1 … 33 for measuring vertical deflection, 34 … 39 for measuring the opening of cracks along the WQ-beam, 40 and 41 for measuring the differential horizontal displacement between the end of the beam and the joint concrete (see Fig. 13) and 42 & 43 for measuring differential vertical displacement between the slab end and the beam.

Page 40: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

40

3.3 Average strain

-

3.4 Horizontal displacements

See Fig. 8, transducers 34 … 41. Transducers 40 and 41 measured the sliding of the joint concrete along the WQ-beam. Fig. 13 gives an impression of the vertical position of these transducers.

3.5 Strain

Fig. 9. Position of strain gauges 1 … 48, all parallel to the beams.

Page 41: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

41

Fig. 10. Position of strain gauges 49 … 53 below WQ-beam, all transverse to the beam, and position of strain gauges 42–48, all parallel to the beam.

4 Special arrangements -

5 Loading strategy

5.1 Load-time relationship

Date of test was 11.10.1990 Before starting the test, all measuring devices were zero-balanced. Thereafter, the actuator loads P were varied in such a way that after five cycles of the type 0 201,6 kN 0 (Stage I) the loads P were monotonously increased to 293 kN (Stage II). At this point unloading was necessary due to a leakage in the hycraulic circuit. After having fixed the leakage, loads P were monotonously increased to failure (Stage III).

5.2 After failure

6 Observations during loading

For the cracks observed during the loading and after the failure, see Figs 11–19.

Stage I Cracks parallel to and along the edges of the WQ-beam were observed in the joint concrete. Some longitudinal cracks along the strands in the soffit of the slabs and vertical cracks in the tie beams at the ends of the floor were discovered.

Stage II The cracks along the edges of the WQ-beam grew gradually and at P = 230 kN they were continuous from one beam end to the other. At P = 273 kN, an inclined crack, starting at the mid-depth of slab 4 next to the WQ-beam and growing upwards, appeared. At P = 283 kN an inclined crack also appeared at the end of slab1, and at P = 292 kN in slab 8.

Stage III

Right before failure, an inclined crack was observed in slab 8, and at the same time, a similar crack appeared in slab 1. At P = 345 kN, slabs 8 and 7 failed in shear.

Page 42: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

42

7 Cracks in concrete

7.1 Cracks at service load

7.2 Cracks after failure

Fig. 11. Inclined cracks in slab 1 after failure of slabs 7 and 8.

Fig. 12. Failure of slabs 8 and 7.

Page 43: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

43

Fig. 13. Failure of slabs 8 and 7.

Fig. 14. Failure of slab 8.

Page 44: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

44

Fig. 15. Failure of slab 8.

Page 45: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

45

Fig. 16. Cracks on the top and at the edges of the floor after failure. The load values refer to actuator load P at which the crack was observed.

Page 46: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

46

Fig. 17. Cracks on the top and at the edges of the floor after failure.

Page 47: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

47

Fig. 18. Cracks after failure in the soffit.

Page 48: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

48

Fig. 19. A part of the previous figure in more detail. The position of the webs in the hollow core slabs is indicated by dashed lines.

8 Observed shear resistance

The total actuator load = 4P vs. measured support reaction below the South end of the middle beam is shown in Fig. 20. The theoretical reaction is calculated assuming simply supported slabs. This comparison shows that the support reaction due to the actuator forces can be calculated accurately enough assuming simply supported slabs. However, the failure of the slab ends at the North end of the middle beam resulted in reduction of support reaction below that end while the actuator force could still slightly be increased. The maximum support reaction is regarded as the indicator of failure.

Page 49: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

49

Fig. 20. Stages I and II. Measured support reaction due to total actuator load 4P.

Fig. 21. Stage III. Measured support reaction due to total actuator load 4P.

Page 50: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

50

The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + VP

where Vg,sl, Vg,jc, Veq and VP are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P, respectively. The test report does not give all these components but VP = 151,6 kN is obtained from the failure load P = 345 kN using the load-reaction relationship shown in Fig. 21 [reaction = 0,8844x(2P)]. In the same way Veq = 1,8 kN is obtained from the weigth of the loading equipment (= 210 kg / one slab). From the nominal geometry and measured density of the concrete Vg,sl + Vg,jc = 12,3+0,4 = 12,7 kN follows. The shear resistance Vobs = 166,1 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 138,4 kN/m.

9 Material properties

9.1 Strength of steel

Component ReH/Rp0,2 Rm Note

MPa MPa

End beam 350 Nominal (Fe 52, no yielding in test)

WQ-beam 350 Nominal (Fe 52C, no yielding in test)

Slab strands J12,5 1570–1630 1770–1860 Nominal (no yielding in test)

Reinforcement Txy 500 Nominal value for reinforcing bars, (no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 12.11.1990 Upper flange of slabs 5 and 3 (3pc. each), = 2398 kg/m3

Mean strength [MPa] 65,3 (+1 d)1) vertically drilled St.deviation [MPa] 4,0 Tested as drilled2)

9.3 Strength of slab concrete, reference tests

Not measured, assumed to be the same as that in the floor test.

Page 51: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

51

9.4 Strength of grout in joints

#

a

a

a

a mm

Date of test

Note

3 150 10.10.1990 Kept in laboratory in the same

Mean strength [MPa] 30,5 (-1 d)1) conditions as the floor specimen

St.deviation [MPa] =2223 kg/m3 #

a

a

a

a mm

Date of test

Note

3 150 12.10.1990 Kept in laboratory in the same

Mean strength [MPa] 31,7 (+1 d)1) conditions as the floor specimen

St.deviation [MPa] =2213 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

10 Results measured during floor test In the following graphs, P is the actuator load.

10.1 Deflections

The measured deflections in Stages II and III are shown in Figs 22–39. The numbers close to the curves refer to the number of transducer, see Fig. 8.

Fig. 22. Stage II.

Page 52: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

52

Fig. 23. Stage III.

Fig. 24. Stage II.

Page 53: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

53

Fig. 25. Stage III.

Fig. 26. Stage II.

Page 54: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

54

Fig. 27. Stage III.

Fig. 28. Stage II.

Page 55: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

55

Fig. 29. Stage III.

Fig. 30. Stage II.

Page 56: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

56

Fig. 31. Stage III.

Fig. 32. Stage II.

Page 57: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

57

Fig. 33. Stage III.

Fig. 34. Stage II.

Page 58: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

58

Fig. 35. Stage III.

Fig. 36. Stage II.

Page 59: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

59

Fig. 37. Stage III.

10.2 Crack width

The differential displacement measured by horizontal transducers 34–39 reflect the crack width in the joint concrete next to the WQ-beam. These differential displacements in stages II and III are shown in Figs 38 and 39.

Fig. 38. Stage II.

Page 60: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

60

Fig. 39. Stage III.

10.3 Average strain

-

10.4 Differential horizontal displacement

A positive value means that the concrete is moving towards the beam end.

Fig. 40. Stage II.

Page 61: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

61

Fig. 41. Stage III.

10.5 Differential vertical displacement

A positive value means that the slab end is deflecting more than the beam.

Fig. 42. Stage II.

Page 62: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

62

Fig. 43. Stage III.

10.6 Strain

Fig. 44. Stage II.

Page 63: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

63

Fig. 45. Stage III.

Fig. 46. Stage II.

Page 64: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

64

Fig. 47. Stage III.

Fig. 48. Stage II.

Page 65: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

65

Fig. 49. Stage III.

Fig. 50. Stage II.

Page 66: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

66

Fig. 51. Stage III.

Fig. 52. Stage II.

Page 67: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

67

Fig. 53. Stage III.

Fig. 54. Stage II.

Page 68: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

68

Fig. 55. Stage III.

Fig. 56. Stage II.

Page 69: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

69

Fig. 57. Stage III.

Fig. 58. Stage II.

Page 70: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

70

Fig. 59. Stage III.

Fig. 60. Stage II.

Page 71: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

71

Fig. 61. Stage III.

11 Reference tests

After the floor test, slabs 3 and 5 were taken for reference test specimens. Their ends which had been supported by the end beams, were loaded in shear as shown in Fig. 62. The concrete tie beam partly outside the slab end, partly in the hollow cores, was not removed before loading.

Fig. 62. Layout of reference test. For Lj, see the next table. Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure + weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

Pa+Peq kN

Va+eq kN

Vobs kN

vobs kN/m

Note

R3 12.10.1990 5940 12,3 285,5 237,4 249,6 208,0 Web shear failure R7 12.10.1990 5950 12,3 239,5 199,2 211,4 176,2 Web shear failure Mean 230,5 192,1

Page 72: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.265.1990

72

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 166,1 kN per one slab unit or 138,4 kN/m. This is 72% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The friction between the spreader beams was not eliminated, which may have

affected the response of the floor test specimen to some extent. 2. The last measured net deflection of the middle beam due to the imposed

actuator loads only (deflection minus settlement of supports) was 17,6 mm or L/284. It was 4,9–6,2 mm greater than that of the end beams. Hence, the torsional stresses due to the different deflection of the middle beam and end beams may have had a minor effect on the failure of the slabs.

3. The shear resistance measured in the reference tests was of the same order

as or slightly higher than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005. The concrete tie beam at the sheared end may have enhanced the resistance. It prevented the deformation of the end section of the slab and thus equalized the strains in the webs of the slab, which effectively eliminated the premature failure of any individual web.

4. The beams did not yield in the floor test. 5. The failure mode was web shear failure of edge slabs close to the supports of

the middle beam. Unlike in an isolated hollow core slab unit, in the floor test the appearance of the first inclined crack close to the slab end did not mean failure but the loads could still be increased.

Page 73: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

73

1 General information

1.1 Identification and aim

VTT.PC.InvT.265.1990 Last update 2.11.2010

PC265 (Internal identification).

Aim of the test To study whether or not the shear resistance of the hollow core slabs is reduced when supported on a shallow prestressed concrete beam

1.2 Test type

Prestressed concrete beam

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 14.–19.11.1990

1.4 Test report Author(s) Koukkari, H.

Name Matalien leukapalkkien ja ontelolaataston kuormituskokeet (Load tests on shallow beams and hollow core floor), in Finnish

Ref. number RAT01854/90

Date 28.11.1990

Availability Confidential, owner is Rakennustuoteteollisuus RTT ry, P.O. Box 381, FI-00131 Helsinki

2 Test specimen and loading

2.1 General plan

Fig. 2. Overview on arrangements.

Page 74: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

74

Fig. 3. Plan and longitudinal section along joint between adjacent slab units. 8 refers to rebar T8, see 9.1.Note the tie reinforcement 3T8 c/c 1200 in the longitudinal joints of slabs and rebars (1+2+1) T8 tying the slab ends at the ends of the specimen and on both sides of the PC beam.

Page 75: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

75

2.2 End beams

- Reinforced concrete beam - Made by Lohja Oy, delivered to VTT on the 2nd of August 1990 - Simply supported, span = 5,0 m - Concrete K40

50 Plastic plugin cores

300

300

80

End beam

5 T20, L=5150

2 T8L=4750

Tie beam

Concrete filling

Dowel reinforcement

Hoops T8c/c 150

Fig. 4. Arrangements at end beam.

Txy refes to a rebar with diameter xy mm, see 9.1.

The size and spacing of the dowel reinforcement has not been given in the report.

2.3 Middle beam

The beam was designed to carry the support reactions from the slabs, somewhat lower than those corresponding to the estimated shear resistance of the slab ends on non-flexible support. The beam was manufactured by Lohja Oy in Nummela factory and it was delivered to VTT on the 2nd of August 1990. The measured camber of the beam was 20,6 mm.

4645

265

480 150

Shear keys 150x150x25 c/c 300

100

150

4 12,5

4545

14 12,5

= 1100 M Papo

= 1100 M Papo

40

A1 A1

A1A1

Fig. 5. Cross-section of PC beam. 12,5 refers to a prestressing strand J12,5 and A1 to a rebar T12, see 9.1. Concrete K60.

Page 76: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

76

Fig. 6. PC beam. Manufacturing drawing by Oy Lohja CAD Ab. J12,5: 7 indented wires, =12,5 mm, Ap = 93 mm2, low relaxation (<2,5% 100 h)

Page 77: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

77

2.4 Arrangements at middle beam

50 Plastic plug

503025 45

Neoprene 30x5

3 T8 L=2000 c/c 1200

3 holes c/c 1200

30

2 T8 L = 4750

40

185

40

50

Fig. 7. Arrangements at middle beam for T8 see 9.1. - Simply supported, span = 5,0 m - 4 load cells below support at South end - joint concrete K30 cast 7.11.1990, maximum aggregate size 8 mm, consistency

1–2 VBs, rapidly hardening cement

2.5 Slabs

1200

35

185

40

40223 223

265

223223152 152

1160

Fig. 8. Nominal geometry of slab units. - Extruded by Parma Oy 29.6.1990, the same bed and casting lot as for the slabs in test VTT.S.WQ.265 - delivered to VTT, 18.10.1990 - concrete K60 - 10 lower strands J12,5 initial prestress 1100 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2, low relaxation (<2,5% 100 h), see 9.1

Page 78: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

78

2.6 Temporary supports

-

2.7 Loading arrangements

See Fig. 7. There was a gypsum layer between the tertiary beams and the top surface of the slabs. The primary spreader beams were in direct contact with the secondary spreader beams and the secondary beams with the tertiary spreader beams. No attempts were made to eliminate the friction. For this reason it is difficult to evaluate, to which extent the spreader beams participated in the load-carrying mechanism.

10

00(f

rom

sla

b en

d)

432A

A A

1

600

P

58

0 1

000

P

1 1 1 1

600 600 600 600 600 600 600

8765

Nor

th

So

uth

11

11

11

11

A

B

B

P

PP

PPrimary

Secondary

Tertiary

Load cells

Fig. 9. Loading arrangement with three layers of spreader beams.

Page 79: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

79

3 Measurements

3.1 Support reactions

There were four load cells below the South end of the PC beam for measuring the support reaction due to the actuator loads.

3.2 Vertical displacement

Fig. 10. Location of transducers 1 … 33 for measuring the vertical deflection, 40 & 41 for measuring the differential horizontal displacement between the end of the beam and the joint concrete (see Figs 11 & 17) and 42 & 43 for measuring differential vertical displacement between the slab end and the beam.

Page 80: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

80

3.3 Average strain

-

3.4 Horizontal displacements

See Fig. 8, transducers 34 … 41. Transducers 40 and 41 measured the sliding of the slab along the WQ-beam. Figs 11 and 17 give an impression of the position of these transducers.

Fig. 11. Position of horizontal transducers 39 and 41at South end of middle beam.

Page 81: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

81

3.5 Strain

Fig. 12. Position of strain gauges 1 … 44, all parallel to the beams.

4 Special arrangements

-

Page 82: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

82

5 Loading strategy

5.1 Load-time relationship

The exact date of the floor test is not mentioned in the test report but it has been before 19.11.1990 and most likely not before 14.11.1990.

Before starting the test, all measuring devices were zero-balanced. Thereafter, the actuator loads P were varied in such a way that after five cycles of the type 0 185,3 kN 0 (Stage I), loads P were monotonously increased to failure load 205,6 kN (Stage II).

5.2 After failure

6 Observations during loading

For the cracks observed during the loading and after the failure, see Figs 12–23.

Stage I Cracks parallel to and along the edges of the PC beam were observed in the joint concrete. Cracks between the tie beams and the slab ends were also observed above the end beams.

Stage II At P = 180 kN, inclined cracks appeared in the upper corners of the outermost webs of slabs 1, 4, 5 and 8 next to the supports of the middle beam. At P = 200 kN new inclined cracks below the first inclined cracks appeared and at P = 205,6 kN a failure took place along these new cracks.

7 Cracks in concrete

7.1 Cracks at service load

7.2 Cracks after failure

Fig. 13. Failure of slab 4.

Page 83: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

83

Fig. 14. Failure of slab 4.

Fig. 15. Cracks parallel to beam. South end of middle beam.

Page 84: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

84

Fig. 16. Failure of slabs 1 (on the right) and 5 (on the left).

Fig. 17. Cracks after failure in slab 8 and in the joint concrete.

Page 85: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

85

Fig. 18. Failure of slab 1.

Fig. 19. Failure of slab 5.

Page 86: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

86

Fig. 20. Cracks parallel to beam in joint concrete. North end of middle beam.

Fig. 21. Cracks on the top and at the edges of the floor after failure. The load values refer to the value of actuator load P at which the crack was observed.

Page 87: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

87

Fig. 22. Failure cracks and other major cracks on the top and at the edges of the floor after failure.

Page 88: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

88

Fig. 23. Cracks in the soffit after failure.

Page 89: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

89

8 Observed shear resistance

The actuator load = P vs. measured support reaction below the South end of the middle beam is shown in Fig. 24.

Fig. 24. Measured support reaction below South end of PC beam vs. actuator load P.

The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + VP

where Vg,sl, Vg,jc, Veq and VP are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P, respectively. VP = 88,9 kN is obtained from the failure load P = 205,6 kN using the load-reaction relationship shown in Fig. 31 [VP = 0,8645x(0,5P)]. In the same way Veq = 1,8 kN is obtained from the weigth of the loading equipment (= 210 kg / one slab). From the nominal geometry and measured density of the concrete Vg,sl + Vg,jc = 12,3+0,4 = 12,7 kN follows. The shear resistance Vobs = 103,4 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 86,2 kN/m.

Page 90: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

90

9 Material properties

9.1 Strength of steel

Component ReH/Rp0,2 MPa

Rm MPa

Note

Slab strands J12,5 1570–1630 1770–1860 Nominal (no yielding in test)

Reinforcement Txy (=xy mm)

500 Nominal value for reinforcing barsA500HW (no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 14.–19.11.1990?Upper flange of slabs 4 and 8 (3pc. each), = 2418 kg/m3

Mean strength [MPa] 63,8 (? d)1) vertically drilled

St.deviation [MPa] 4,6 Tested as drilled2)

9.3 Strength of slab concrete, reference tests

-

9.4 Strength of grout in joints

#

a

a

a

a mm

Date of test

Note

3 150 14.11.1990 Kept in laboratory in the same

Mean strength [MPa] 26,8 (? d)1) conditions as the floor specimen

St.deviation [MPa] =2267 kg/m3

1) Date of material test minus date of structural test (floor test or reference test) 2) After drilling, kept in a closed plastic bag until compression

Page 91: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

91

10 Results measured during floor test In the following graphs, P is the actuator load.

10.1 Deflections

The measured deflections in Stage II are shown in Figs 25–41. The numbers close to the curves refer to the number of transducer, see Fig. 10.

Fig. 25. Measured deflection.

Fig. 26. Measured deflection.

Page 92: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

92

Fig. 27. Measured deflection.

Fig. 28. Measured deflection.

Page 93: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

93

Fig. 29. Measured deflection.

Fig. 30. Measured deflection.

Page 94: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

94

Fig. 31. Measured deflection.

Fig. 32. Measured deflection.

10.2 Crack width

The differential displacement measured by horizontal transducers 34–39 reflect the crack width in the joint concrete next to the middle beam. These measured displacements in Stage II are shown in Fig. 33.

Page 95: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

95

Fig. 33. Opening of joint in Stage II.

10.3 Average strain

-

10.4 Differential horizontal displacement

A positive value means that the concrete is moving towards the beam end.

Fig. 34. Differential horizontal displacement between South end of middle beam and edge of slab in Stage II.

Page 96: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

96

10.5 Differential vertical displacement

A positive value means that the slab end is deflecting more than the beam.

Fig. 35. Differential vertical displacement between middle beam and slab end. Stages I and II.

10.6 Strain

Fig. 36. Strain measured by gauges 1–6. Stage II.

Page 97: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

97

Fig. 37. Strain measured by gauges 7–12. Stage II.

Fig. 38. Strain measured by gauges 13–18. Stage II.

Page 98: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

98

Fig. 39. Strain measured by gauges 19–24. Stage II.

Fig. 40. Strain measured by gauges 25–28, 33–36 and 42–43. Stage II.

Page 99: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

99

Fig. 41. Strain measured by gauges 29–32 and 38–41. Stage II.

11 Reference tests

No reference tests were performed for the slabs in the present floor test. Instead, the reference tests carried out for two slabs taken from floor test VTT.S.WQ.265.1990 are regarded as applicable to this case, too, because

- the slabs for these two floor tests were taken from the same casting lot and bed

- the slabs were cast as early as 29.6.1990 and the change in concrete strength must have been very small in October – November 1990 when the tests were carried out.

The results presented below are taken from report VTT.S.WQ.265.1990. Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure + weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

Pa+Peq kN

Va+eq kN

Vobs kN

vobs kN/m

Note

R3 12.10.1990 5940 12,3 285,5 237,4 249,6 208,0 Web shear failure

R7 12.10.1990 5950 12,3 239,5 199,2 211,4 176,2 Web shear failure

Mean 230,5 192,1

Page 100: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.265.1990

100

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 103,4 kN per one slab unit or 86,1 kN/m. This is 45% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The friction between the spreader beams was not eliminated, which may have

affected the response of the floor test specimen to some extent. This additional stiffness reduced the deflection of the floor but it is difficult to evaluate whether the net effect on the observed shear resistance was positive or negative.

2. The net deflection of the end beams (deflection minus settlement of supports was very small beams, apparently < 2 mm. The original idea was to reduce the horizontal interaction between the end beam and the slab ends above it, but due to some misunderstanding, the beams were provided with dowel reinforcement which was not specified in the drawings. These dowels made the laboratory personnel believe that the slab ends and the end beam must be cast together. In this way the resulting composite beam became far too stiff to deflect like the middle beam, which was the primary design criterion for the end beam.

3. The last measured net deflection of the middle beam due to the imposed actuator loads only (deflection minus settlement of supports) was 9,9 mm or L/505. It was ≈8 mm greater than that of the end beams. Hence, the torsional stresses due to the different deflection of the middle beam and end beams may have had a minor effect on the failure of the slabs. On one hand, the torsion in the slab elements due to the different deflection of the middle beam and end beams reduced the deflection of the middle beam but increased the torsional shear stresses in the webs of the outermost slab elements. The net effect of the torsion on the observed shear resistance may have been positive or negative.

4. The shear resistance measured in the reference tests was of the same order as or slightly higher than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure.VTT Research Notes 2292, Espoo 2005. The concrete tie beam at the sheared end may have enhanced the resistance in the reference tests. It prevented the deformation of the end section of the slab and thus equalized the strains in the webs of the slab, which effectively eliminated the premature failure of any individual web.

5. The beams did not yield in the floor test.

6. The failure mode was web shear failure of edge slabs close to the supports of the middle beam. Unlike in an isolated hollow core slab unit, in the floor test the appearance of the first inclined crack close to the slab end did not mean failure but the loads could still be increased.

7. The failure mode was web shear failure of edge slabs close to the supports of the middle beam. Unlike in an isolated hollow core slab unit, in the floor test the appearance of the first inclined crack close to the slab end did not mean failure but the loads could still be increased.

Page 101: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

101

1 General information

1.1 Identification and aim

VTT.PC.InvT.400.1992 Last update 2.11.2010

PC400 (Internal identification)

Aim of the test To study the shear resistance of thick hollow core slabs supported on beams.

1.2 Test type

Prestressed concrete beam

Prestressed concrete beam

Prestressed concrete beam

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 24.2.1992

1.4 Test report

Author(s) Pajari, M.

Name Loading test for 400 mm hollow core floor supported on prestressed concrete beams

Ref. number RAT-IR-3/1993

Date 15.4.1993

Availability Public, available on request from VTT Expert Services, P.O. Box 1001, FI-02044 VTT.

Financed by Lohja Oy, Finland; NCC Prefab AB, Sweden; Parma Oy, Finland; Oy Partek Concrete Ab, Finland; Skanska Prefab AB, Sweden and AB Strängbetong, Sweden. The Finnish companies were financially supported by TEKES, Finland.

2 Test specimen and loading (see also Appendix A)

2.1 General plan

4

1

2

3

4444

7

8

5

444

5000

7200 7200

1260 1260

6

50

480

50

Fig. 2. Plan.

Page 102: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

102

2.2 End beams

Simply supported, prestressed concrete beams. Span = 5,0 m Concrete: K60

50

40

1342

40 p0

5600

A

A

100

50

40

40 40100 100

380

Strands 3 J12,9

A A

= 1250 MPa

p0

Strands 8 J12,9

= 1250 MPa

Fig. 3. End beam. For J12,9 see 2.3.

Plywood

140140

380

80

400L = 4750

50

30 30

Plastic plug

End beam

Tie beam

2 T10

Fig. 4. Arrangements at end beam. T10 refers to a reinforcing bar, see 2.4.

3503 T12 c/c 1200

1100 Fig. 5. Tie reinforcement in joints between adjacent slabs. T12 refers to a reinforcing bar, see 2.4.

Page 103: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

103

2.3 Middle beam

Concrete: K60 Tendons: J12,9: Prestressing strand, 7 wires, =12,9 mm, Ap = 100 mm2, see 9.1

40 150

50

50

50 5050 50

5050 150 40

880

1342

115

4013

400 4040= 1210 MPa kN

po

Strands 12+12 J12,9

po

Strands 1+1 J12,9

= 1210 MPa po

Strands 2+2 J12,9

400

150

30

150

5600

A

A

at both endsDebonding: 4 J12,9 , L=1300 A A

= 1310 MPa

Holes

120012001600

150

150

Shear keys 150x150x15 c/c 300

100

Fig. 6. Elevation and section of middle beam.

2.4 Arrangements at middle beam

320 mm of all hollow cores where filled by concrete. Neither slots nor holes were made in the hollow core slabs.

480 50 320320 50

200

150

10

320

40

40

550

4 T10 L = 5550

Neoprene 20x10

Hard mineral wool

60 140

Fig. 7. Section along hollow cores.

Page 104: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

104

L = 2500 3 T12 c/c 1200

30

Fig. 8. Tie reinforcement in joints between adjacent slabs. - Simply supported, span = 5,0 m Txy: Hot rolled, weldable rebar A500HW, = xy mm, see 9.1.

2.5 Slabs

1200

400

35 40

40

62,1

197,9

60

60216

1158

R12

5

18

Fig. 9. Nominal geometry of slab units (in scale).

- Extruded by Partek Betoniteollisuus Oy, Hyrylä factory 15.1.1992 - 13 lower strands J12,5 initial prestress 1100 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

119538,5 40,2

48,7

306,4

1156

bw,i = 290,9bw,i

Fig. 10. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 2,0 in slab 5; 1,4 in slab 4; 1,3 in slab 7 and 0,9 in slabs 3 and 4 Measured weight of slab units = 5,49 kN/m

2.6 Temporary supports

Temporary supports below beams (Yes/No) - No

Page 105: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

105

2.7 Loading arrangements

There were two separate, manually controlled hydraulic circuits, one for actuators P1 and the other for actuators P2, see Fig. 11. Attempts were made to keep P1 ≈ P2. The primary spreader beams on the top of the floor were railway rails cut in pieces slightly shorter than 1,2 m. The friction between the secondary and primary spreader beams was eliminated by teflon plates.

4

1

2

3

4444

7

8

5

444

5000

A AB

B

7200 7200

1260 1260

6

2P1

2P2 2P

1

2P2

2P1

4P22P1

AA

580

Fig. 11. Plan. P1 and P2 refer to vertical actuator forces.

P2

P2

P2

P2 2P

12P

1

Det A

5000

BB

Fig. 12. Section B-B, see previous figure.

Gypsum

Teflon plates

P Steel platesFDet A

2

F

F

F

Fig. 13. Detail A, see previous figure.

Page 106: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

106

3 Measurements

3.1 Support reactions

1

5

3 loadcells

Sou

th

Fig. 14. Load cells below the South end of the middle beam.

3.2 Vertical displacement

44444 445

6

7

8

4

3

2

110

6

7

8

9

11

12

13

14

5 15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

7200 7200

3600 36001400 1400

South

North

580

Fig. 15. Location of transducers 5 … 39 for measuring vertical deflection along lines I … VII.

3.3 Average strain

7070

5

6

7

8

47 46

4849

1

2

3

4

(61)

54(60)

53(59)

52(58)

(57)

50(56)

5155

North

South

L

TransducerSteel bar

Fig. 16. Apparatus for measuring average strain. L =1120mm and 1060 mm for the bottom and top side transducers, respectively.

Fig. 17. Position of device (transducers 50–61) measuring average strain parallel to the beams. Transducers 46–49 measured the sliding of the outermost slabs along the beam. Numbers in parentheses refer to the soffit of the floor, others to the top side.

Page 107: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

107

3.4 Horizontal. displacements

5

6

7

8

1

2

3

4

North

South

41 40

43

45 44

42

Fig. 18. Transducers 40–45 measuring crack width on the top of the floor.

3.5 Strain To detect longitudinal cracks along strands, the soffit of slabs 2, 3, 6 and 7 was provided

with strain gauges as shown in Figs 19 and 20. The measuring length of the gauges was 67 mm.

80

50 50

67

Fig. 19. Strain gauges below strands. 2

3

6

7

1

2

34

5

67

8

910 1112

1314

1516

1819

20

21

2223

24

17

25

2627

2829

30 3132

33

3435

3637

3839

40250

Fig. 20. Position of strain gauges. The webs of the slabs are indicated by dot-and-dash lines below strands.

4 Special arrangements

-

Page 108: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

108

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 24.2.1992 When the actuator forces Pi were equal to zero but the weight of the loading equipment was on, all measuring devices were zero-balanced. The loading history is shown in Fig.21. Note, that the number of load step, not the time, is given on the horizontal axis. In the following, the loading until failure (steps 1–29) is called Stage 1 and the post-failure stage with a support below failed slab 1 (steps 30–38) Stage 2. In Stage 3 the support was still under slab 1 and the load on slab 2 was removed.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30 35 40

Load step

Pi [

kN]

P1

P2

Stage 1 Stage 3Stage 2

Fig. 21. Development of actuator loads P1 and P2. The weight of loading equipment per actuator was 1,2 kN and 5,6 kN for actuators P1 and P2, respectively. Consequently, the imposed load per slab was F1 = P1 + 1,2 kN for slabs 2, 3, 6 and 7 F2 = P2 + 5,6 kN for slabs 1, 4, 5 and 8

5.2 After failure

See Stages 2 and 3 on the next page.

Page 109: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

109

6 Observations during loading

Stage 1 At P1 = 276,8 kN, P2 = 265,3 kN a shear failure took place in slab 1

between the line load and the support, see Appendix A, Fig. 4.

Stage 2 A support was placed below the line load F1 on slab 1 as shown in Fig. 23. The aim was to continue the loading with seven line loads but the end of slab 2 failed shortly after the reloading was started as shown in Fig. 24. This failure was obviously due to the load transfer from slab 1 to slab 2 across the vertical joint because the support under slab 1 was not able to carry load before a certain additional deflection of slab 1 had taken place, and this deflection was not possible before slab 2 had failed.

Stage 3 After the failure of slab 2, the actuator on slab 2 was removed. Now slab 1 was tightly lying on the support below the line load. A shear failure took place in slab 5 at P1 = 375,0 kN, P2 = 379,0 kN, see Appendix A, Figs 5–7.

After failure When demolishing the test specimen it was observed that the core fillings were perfect and the gap between the soffit of the slabs and the upper surface of the ledges of the middle beam was completely filled by the grout, see Appendix A, Figs 8–12.

The middle beam looked intact after the failure.

7 Cracks in concrete

7.1 Cracks at service load

-

7.2 Cracks after failure

1

2

3

44

7

8

5

6

F

F

F

1

2

2

F17

4

F

F

F

1

2

2

F1

Fig. 22. Stage 1. Cracks on the top and at the edges of the floor after failure.

Page 110: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

110

1

2

3

44

7

8

5

6

F

F

F

6

5

8

F7

7

4

F

F

F

2

1

4

F3

Temporary support

Fig. 23. Stage 2. Cracks after failure of slab 2.

1

2

3

44

7

8

5

6

F

F

F

6

5

8

F7

7

4F4

F3

Temporary support

Fig. 24. Stage 3. Cracks after failure of slab 5.

8 Observed shear resistance

The maximum support reaction is regarded as the indicator of failure. The failure most likely took place before the load values P1 = 276,8 kN, P2 = 265,3 kN were measured and when the sum of actuator loads load on half floor was = 1085,0 kN. This is supported by the fact that the efforts to keep all actuator loads equal succeeded well except at this point. Due to the softening of slab 1 the pressure in actuators P2 was reduced and the middle beam rose upwards, which resulted in increasing pressure in actuators P1. This is in accordance with the difference in loads shown in Fig. 21 at steps 22 and 23. In this way the support reaction of the South end of the middle beam was reduced at the expense of increased support reaction at the North end.

Fig. 25 shows the relationship between the measured support reaction below the South end of the middle beam and the sum of actuator loads on half floor. The ratio of the reaction to the load is shown in Fig. 26 and in a larger scale in Fig. 27. Assuming simply supported slabs gives the theoretical ratio of 0,835. The measured support reaction seems to follow the theoretical value rather well until load 1015 kN at which the ratio 0,845 is obtained. The next step gives only 0,810 which suggests that slab 1 has already lost a part of its shear stiffness and the load on it is partly transferred to slab 2.

After failure of slab 1 it is unclear, how much load was transferred via slab 1 to the middle beam and how much directly to the floor of the hall. Therefore, no definite values for the shear resistance are given in Stages 2 and 3.

Page 111: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

111

0

100

200

300

400

500

600

700

800

900

0 200 400 600 800 1000 1200

Load on half floor [ kN]

Reaction [kN]

Fig. 25. Stage 1. Support reaction measured below South end of the middle beam vs. load on half floor = 2(P1 + P2 ).

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

0 200 400 600 800 1000 1200

Load on half floor [ kN]

Reaction / load on half floor

Fig. 26. Ratio of measured support reaction (below South end of the middle beam) to load on half floor.

0,80

0,81

0,82

0,83

0,84

0,85

0,86

0 200 400 600 800 1000 1200

Load on half floor [ kN]

Reaction / load on half floor

Fig. 27. A part of the previous figure in a large scale.

Page 112: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

112

The observed shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pi, respectively. It is concluded that the maximum support reaction of the failed slab 1 has been at least Vp = 0,845 x (actuator loads on half floor) /4 = 0,845 x(276,8+265,5) /2 = 229,1 kN. In the same way, the support reaction due to the weight of the loading equipment has been 0,845x(1,2+5,6)/2 = 2,87 kN. Vg,jc is calculated from the nominal geometry of the joints and measured density of the grout. When calculating Vg,sl, the measured weight of the slabs is used. The values of the shear force components are given in Table 1 below. Table 1. Components of shear resistance due to different loads.

Action Load Shear force

kN/slab

Weight of slab unit 5,49 kN/m 19,4

Weight of joint concrete 0,19 kN/m 0,7

Loading equipment (1,2+5,6)/2 kN/slab 2,9

Actuator loads (276,8+265,5)/2 kN /slab 229,1

The observed shear resistance Vobs = 252,1 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 210,1 kN/m.

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

Slab strands J12,5 1630 1860 Nominal (no yielding in test)

Beam strands J12,5 1630 1860 Nominal (no yielding in test)

Reinforcement Txy 500 Nominal value for reinforcing bars (no yielding in test)

Page 113: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

113

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 2.4.19920)? Upper flange of slab 1, Mean strength [MPa] 81,4 (+? d)1) vertically drilled St.deviation [MPa] 5,1 Tested as drilled2)

Density = 2437 kg/m3 0) This is the date given in the report. It is most likely too late because it is the same as the date of the core tests for VTT.S.WQ.400.1992 carried out after the present floor test #

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 2.4.19920)? Upper flange of slab 5, Mean strength [MPa] 84,3 (+? d)1) vertically drilled St.deviation [MPa] 2,2 Tested as drilled2)

Density = 2442 kg/m3 0) This is the date given in the report. It is most likely too late because it is the same as the date of the core tests for VTT.S.WQ.400.1992 carried out after the present floor test

9.3 Strength of slab concrete, reference tests

The slabs for the reference tests were taken from the floor test specimen.

9.4 Strength of concrete in middle beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 100 100 18.3.1992 Top surface of beam, Mean strength [MPa] 64,3 (+22 d)1) vertically drilled St.deviation [MPa] 3,2 Tested as drilled2)

Density = 2358 kg/m3

9.4 Strength of grout in joints and core filling

#

a

a

a

a mm

Date of test

Note

6 150 24.2.1992 Kept in laboratory in the same Mean strength [MPa] 27,8 (+0 d)1) conditions as the floor specimen St.deviation [MPa] 0,58

1) Date of material test minus date of structural test (floor test or reference test) 2) After drilling, kept in a closed plastic bag until compression

9.5 Strength of concrete in end beams

Not measured, nominal value K60

Page 114: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

114

10 Measured displacements Note that the last points on each curve represent the post failure situation.

10.1 Deflections

0

50

100

150

200

250

300

0 1 2 3 4 5 6 7 8 9 10

Deflection [mm]

P2

[kN

]

5

6

7

8

9

Fig. 28. Deflection on line I, Western end beam.

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14

Deflection [mm]

P2

[kN

]

10

11

12

13

14

Fig. 29. Deflection on line II.

Page 115: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

115

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14

Deflection [mm]

P2

[kN

]

15

16

17

18

19

Fig. 30. Deflection on line III.

0

50

100

150

200

250

300

0 1 2 3 4 5 6 7 8 9 10

Deflection [mm]

P2

[kN

]

20

21

22

23

24

Fig. 31. Deflection on line IV, middle beam.

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14 16 18

Deflection [mm]

P2

[kN

]

25

26

27

28

29

Fig. 32. Deflection on line VI.

Page 116: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

116

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14 16 18

Deflection [mm]

P2

[kN

]

30

31

32

33

34

Fig. 33. Deflection on line VII.

0

50

100

150

200

250

300

0 1 2 3 4 5 6 7 8 9 10

Deflection [mm]

P2

[kN

]

35

36

37

38

39

Fig. 34. Deflection on line VIII along Eastern end beam.

0

50

100

150

200

250

300

350

400

-4 -2 0 2 4 6 8 10

Deflection [mm]

P2

[kN

]

5

6

7

8

9

Fig. 35. Deflection on line I along Western end beam, stages 1–3.

Page 117: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

117

0

50

100

150

200

250

300

350

400

0 2 4 6 8 10 12

Deflection [mm]

P2

[kN

]

20

21

22

23

24

Fig. 36. Deflection on line IV along middle beam, stages 1–3.

0

50

100

150

200

250

300

350

400

0 2 4 6 8 10

Deflection [mm]

P2

[kN

]

35

36

37

38

39

Fig. 37. Deflection on line VIII along Western end beam, stages 1–3.

0

50

100

150

200

250

300

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

P2

[kN

]

West end

East end

Middle

Fig. 38. Stage 1. Net deflection of mid-point of beams (rigid body motion = settlement of beam supports eliminated).

Page 118: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

118

The last measured net deflection of the middle beam was 5,4 mm before the highest load level and the first measured after it was 7,2 mm. Before failure, the net deflection of the middle beam was 1,4 mm and after the highest load level 1,7–2,2 mm greater than that of the end beams.

10.2 Crack width

0

50

100

150

200

250

300

0,0 0,5 1,0 1,5 2,0

Differential displacement [mm]

P2

[kN

]

40

41

42

43

44

45

Fig. 39. Differential displacement ( crack width) measured by transducers 40–46.

10.3 Average strain (actually differential displacement)

0

50

100

150

200

250

300

350

400

-1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2

Differential displacement [mm]

P2

[kN

]

50

51

52

53

54

55

Fig. 40. Differential displacement at top surface of floor measured by transducers 50–55.

Page 119: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

119

0

50

100

150

200

250

300

350

400

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4

Differential displacement [mm]

P2

[kN

]

56

57

58

59

60

61

Fig. 41. Differential displacement at soffit measured by transducers 56–61.

10.4 Shear displacement

0

50

100

150

200

250

300

350

400

-1,0 -0,9 -0,8 -0,7 -0,6 -0,5 -0,4 -0,3 -0,2 -0,1 0,0

Differential displacement [mm]

P2

[kN

]

46

47

48

49

Fig. 42. Stages 1–3. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

Page 120: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

120

10.5 Strain

A gradual growth in the measured strain means that there has been a crack, most likely attributable to the release of the prestressing force, before the loading. A sudden increase in crack width indicates a new crack. An example of the former and latter behaviour are illustrated e.g. by transducers 35 and 34, respectively, see Fig. 49.

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

]

12345

Fig. 43. Strain measured by gauges 1–5.

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 678910

Fig. 44. Strain measured by gauges 6–10.

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 1112131415

Fig. 45. Strain measured by gauges 11–15.

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 1617181920

Fig. 46. Strain measured by gauges 16–20.

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 2122232425

Fig. 47. Strain measured by gauges 21–25.

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 2627282930

Fig. 48. Strain measured by gauges 26–30.

Page 121: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

121

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 3132333435

Fig. 49. Strain measured by gauges 31–35.

0

50

100

150

200

250

300

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 3637383940

Fig. 50. Strain measured by gauges 36–40.

In Figs 51 and 52 the cracks below the soffit of slab 2, 3, 6 and 7 are shown.

2

3

6

7

Visible crack250

Crack detected by strain gauge

Visible crack,not detectedby strain gauge

W2

W3

W4

W5W6

W7

W8

W9

W10

W12

W13

W14

W15W16

W17

W18

W19

W20

W1W11 Fig. 51. Location of cracks observed visually or by strain gauges under load P2 = 153,2 kN.

Page 122: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

122

2

3

6

7

250

Crack

W2

W3

W4

W5W6

W7

W8

W9

W10

W11

W12

W13

W14

W15W16

W17

W18

W19

W20

W1

Fig. 52. Location of cracks observed visually or by strain gauges under load P2 = 251,3 kN.

11 Reference tests

4040L

1260P

V

Tie beam

40L

P

V

1260

40

a)

b)

Fig. 53. Layout of reference test. a) With tie beam, slabs 1 and 5. b) Without tie beams, slabs 7 and 8. For L, see the Table 2.

Page 123: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

123

Table 2. Span L, ultimate load Pobs, ultimate shear force Vobs and failure mode in

reference tests. The weight of the loading equipment = 0,5 kN is included in Pobs.

Slab

L

mm Tie

beam Pu

kN

Vu

kN

Failure mode

1 5985 Yes > 600* > 494*

1050

12601150

5 5000 Yes 591 461 12601230

990

Anchorage failure

7 7110 No 564 487 1260750

Shear tension failure

8 7115 No 568 490 1150

700

1260

Shear tension failure

Mean 483

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 252,1 kN per one slab unit or 210,1 kN/m. This is 52% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only (deflection minus settlement of supports) was 5,4–7,2 mm or L/926–L/694, i.e. rather small.

2. The shear resistance measured in the reference tests was slightly higher than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005.

3. Before failure, the net deflection of the middle beam was 1,5 mm and right after the highest load level 1,8–2,2 mm greater than that of the end beams. This is a too small difference to cause considerable torsional stresses in the slabs.

The failure mode was web shear failure of edge slab 1 close to the middle beam. The middle beam seemed to recover completely after the failure.

Page 124: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A124

APPENDIX A: PHOTOGRAPHS

Page 125: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A125

Page 126: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A126

Page 127: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A127

Page 128: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A128

Page 129: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A129

Page 130: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A130

Page 131: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A131

Page 132: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.1992

A132

Page 133: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

133

1 General information

1.1 Identification and aim

VTT.S.WQ.400.1992 Last update 2.11.2010

ST400 (Internal identification)

Aim of the test To study the shear resistance of thick hollow core slabs supported on steel beams.

1.2 Test type

Steel beam Steel beamSteel beam

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 25.3.1992

1.4 Test report

Author(s) Pajari, M.

Name Loading test for 400 mm hollow core floor supported on steel beams

Ref. number RAT-IR-4/1993

Date 23.4.1993

Availability Public, available on request from VTT Expert Services, P.O. Box 1001, FI-02044 VTT.

Financed by Lohja Oy, Finland; NCC Prefab AB, Sweden; Parma Oy, Finland; Oy Partek Concrete Ab, Finland; Skanska Prefab AB, Sweden and AB Strängbetong, Sweden. The Finnish companies were financially supported by TEKES, Finland.

2 Test specimen and loading (see also Appendix A)

2.1 General plan

4

1

2

3

4444

7

8

5

444

5000

7200 7200

1260 1260

6

50

306

50 North

South

Fig. 2. Plan.

Page 134: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

134

2.2 End beams

Simply supported box girders made of steel. Span = 5,0 m

Plywood

200

300

80

400L = 4750

50

30 30

Plastic plug

End beam

Tie beam

2 T10

Fig. 3. Arrangements at end beam. T10 refers to a reinforcing bar, see 2.4.

350 1100

3 T12 c/c 1200

Fig. 4. Tie reinforcement in joints between adjacent slabs. T12 refers to a reinforcing bar, see 2.4.

2.3 Middle beam

140

40

30

8

586

290

Fe 52

140

Holes 3 16

5000100 100

1200 1200 1400

60

Stiffening plate Stiffening plate

Fig. 5. Elevation and section of middle beam.

Page 135: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

135

2.4 Arrangements at middle beam

5050

320

40

40140

30

40

30

8

586

290 30

Hard mineral wool

Plastic plugFe52

4 T10 L = 5150

Fig. 6. Section along hollow cores.

L = 2500

60

3 T12 c/c 1200 Fig. 7. Tie reinforcement in joints between adjacent slabs. - Simply supported, span = 5,0 m

Txy: Hot rolled, weldable rebar A500HW, = xy mm, see 9.1.

2.5 Slabs

1200

400

35 40

40

62,1

197,9

60

60216

1158

R12

5

18

Fig. 8. Nominal geometry of slab units (in scale).

- Extruded by Partek Betoniteollisuus Oy, Hyrylä factory 15.1.1992 - 13 lower strands J12,5 initial prestress 1100 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

119538,5 40,1

49,0

303,54

1158

bw,i = 290,8bw,i

Fig. 9. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 1,2 and 1,1 in slab 1; 1,0 in slabs 3 and 7 Measured weight of slab units = 5,51 kN/m

Page 136: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

136

2.6 Temporary supports

Temporary supports below beams (Yes/No) - No

2.7 Loading arrangements

There were two separate, manually controlled hydraulic circuits, one for actuators P1 and the other for actuators P2, see Fig. 10. Attempts were made to keep P1 ≈ P2 so as to generate two linear line loads on the floor. The primary spreader beams on the top of the floor were railway rails cut in pieces slightly shorter than 1,2 m. The friction between the secondary and primary spreader beams was eliminated by teflon plates.

4

1

2

3

4444

7

8

5

444

5000

A AB

B

7200 7200

1260 1260

6

2P1 2P

2 2P1

2P2

2P1

4P22P1

AA

406

North

South

Fig. 10. Plan. P1 and P2 refer to vertical actuator forces.

P2

P2

P2

P2 2P

12P

1

Det A

5000

BB

Fig. 11. Section B-B, see previous figure.

Gypsum

Teflon plates

P Steel platesFDet A

2

F

F

F

Fig. 12. Detail A, see previous figure.

Page 137: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

137

3 Measurements

3.1 Support reactions

1

5

3 loadcells

Sou

th

Fig. 13. Load cells below the South end of the middle beam.

3.2 Vertical displacement

44444 445

6

7

8

4

3

2

110

6

7

8

9

11

12

13

14

5 15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

7200 7200

3600 36001400 1400

South

North

406

Fig. 14. Location of transducers 5 … 39 for measuring vertical deflection.

3.3 Average strain

(61)

54(60)

53(59)

52(58)

(57)

50(56)

5155

47 46

7070

(62)(63)

48(65) (64)49

5

6

7

8

1

2

3

4

South

North

L

TransducerSteel bar

Fig. 15. Apparatus for measuring average strain. L =1120mm and 1060 mm for the bottom and top side transducers, respectively.

Fig. 16. Position of device (transducers 50–61) measuring average strain parallel to the beams. Transducers 46–49 and 62–65 measured the sliding of the outermost slabs along the beam. Numbers in parentheses refer to the soffit of the floor, others to the top side.

Page 138: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

138

3.4 Horizontal displacements

5

6

7

8

1

2

3

4

North

South

41 40

43

45 44

42

Fig. 17. Transducers 40–45 measuring crack width on the top of the floor.

3.5 Strain To detect longitudinal cracks along strands, the soffit of slabs 2, 3, 6 and 7 was provided

with strain gauges as shown in Figs 18 and 19. The measuring length of the gauges was 67 mm.

80

50 50

67

Fig. 18. Strain gauges below strands.

2

3

6

7

1

2

34

5

67

8

910 1112

1314

1516

1819

20

21

2223

24

17

25

2627

2829

30 3132

33

3435

3637

3839

40160

Fig. 19. Position of strain gauges. The webs of the slabs are indicated by dot-and-dash lines below strands.

4 Special arrangements

-

Page 139: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

139

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 25.3.1992 All measuring devices were zero-balanced when the actuator forces Pi were equal to zero but the weight of the loading equipment was on. The loading history is shown in Fig. 20. Note, that the number of load step, not the time, is given on the horizontal axis. In the following, the cyclic stage (steps 1–16) and the monotonous stage until failure (steps 16–41) are called Stage 1.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30 35 40 45

Load step

Pi [

kN]

P1

P2

Stage 1

Fig. 20. Development of actuator loads P1 and P2. The weight of loading equipment per actuator was 1,2 kN and 5,6 kN for actuators P1 and P2, respectively. Consequently, the imposed load per slab was F1 = P1 + 1,2 kN for slabs 2, 3, 6 and 7 F2 = P2 + 5,6 kN for slabs 1, 4, 5 and 8

Page 140: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

140

5.2 After failure

After failure, the failed slab 5 was temporarily supported and the load test was continued. This is called Stage 2.

0

50

100

150

200

250

300

350

400

450

0 5 10 15 20 25 30 35

Load step

Pi [

kN]

P1

P2

Stage 2

Fig. 21. Development of actuator loads P1 and P2 in Stage 2.

6 Observations during loading

Stage 1 At P1 = 300,3 kN, P2 = 297,1 corners of slabs 5 and 8 cracked next to the support of the beam. At P1 = 319,7 kN, P2 = 318,1 kN a narrow shear crack appeared in the web of slab 5, see Fig. 22. It grew in width and length when the loads were increased. At P1 = 337,9 kN, P2 = 334,2 kN a shear failure took place in slab 5 between the line load and the support, see Appendix A, Figs 3–5.

Stage 2 After the failure, a temporary support was placed below slab 5 as shown in Fig. 23. The aim was to continue the load test with seven line loads. When the loads were increased, a corner of slab 1 cracked as shown in Fig. 23. At P1 = 381,1 kN, P2 = 377,2 kN slabs 6 and 7 failed as shown in Fig. 23 and in Annex A, Figs 7–11.

After failure When demolishing the test specimen it was observed that the interface between the webs of the middle beam and the slab ends had cracked neatly along the edge of the beam, see Appendix A, Fig. 6.

The middle beam looked intact after the failure.

Page 141: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

141

7 Cracks in concrete

7.1 Cracks at service load

Not documented.

7.2 Cracks after failure

= 300 kN

= 320 kN

= 300 kN

= 340 kN

F 1

F 2

F 1 F 1

F 1

F 2 F 2

F 2

F 2

F 2 F 2

F 2

1

2

3

4448

5

6

7

Fig. 22. Stage 1. Cracks after failure on the top and at the edges of the floor specimen.

Temporary supportunder slab

F2

1F

5F

F2

F2 F2

1F1F

1F

= 1

2

3

4448

5

6

7

Fig. 23. Stage 2. Cracks after failure of slabs 6 and 7.

8 Observed shear resistance

The maximum measured support reaction is regarded as the indicator of failure. The failure took place at P1 = 337,9 kN, P2 = 334,2 kN or F1 = 339,1 kN, F2 = 339,8 kN.

Fig. 24 shows the relationship between the measured support reaction below the South end of the middle beam and the sum of actuator loads on half floor. The ratio of the reaction to the load is shown in Fig. 25 and in a larger scale in Fig. 26. Assuming simply supported slabs gives the theoretical ratio of 0,825. The measured support reaction seems to be ≈ 0,805 times the load before failure.

Page 142: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

142

0100200300400500600700800900

10001100

0 200 400 600 800 1000 1200 1400

Load on half floor [ kN]

Reaction [kN]

Fig. 24. Stage 1. Support reaction measured below South end of the middle beam vs. load on half floor = 2(P1 + P2).

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

0 200 400 600 800 1000 1200 1400

Load on half floor [ kN]

Reaction / Load on half floor

Fig. 25. Ratio of measured support reaction (below South end of the middle beam) to actuator loads on half floor.

0,790

0,795

0,800

0,805

0,810

600 700 800 900 1000 1100 1200 1300 1400

Load on half floor [ kN]

Reaction / Load on half floor

Fig. 26. A part of the previous figure in a large scale.

Page 143: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

143

The observed shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pi, respectively. It is concluded that the maximum support reaction due to the imposed load of the failed slab 5 due has been

Vp = 0,805 x (actuator loads on half floor) /4 = 0,805 x (337,9+334,2) /2 = 270,5 kN.

In the same way, the support reaction due to the weight of the loading equipment has been 0,805x(1,2+5,6)/2 = 2,74 kN. Vg,jc is calculated from the nominal geometry of the joints and measured density of the grout. When calculating Vg,sl, the measured weight of the slabs is used. The values of the shear force components are given in Table 1 below. Table 1. Components of shear resistance due to different loads.

Action Load Shear force

kN/slab

Weight of slab unit 5,51 kN/m 19,7

Weight of joint concrete 0,19 kN/m 0,7

Loading equipment (1,2+5,6)/2 kN/slab 2,7

Actuator loads (337,9+334,2) /2 kN /slab 270,5

The observed shear resistance Vobs = 293,6 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 244,7 kN/m.

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

Slab strands J12,5 1630 1860 Nominal (no yielding in test)

Reinforcement Txy 500 Nominal value for reinforcing bars, no yielding in test

End beams ≈ 350 Nominal value for Fe 52, no yielding in test

Page 144: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

144

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 2.4.1992 Upper flange of slab 4, Mean strength [MPa] 77,1 (+8 d)1) vertically drilled

St.deviation [MPa] 5,8 Tested as drilled2)

Density = 2425 kg/m3 #

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 2.4.1992 Upper flange of slab 8, Mean strength [MPa] 81,0 (+8 d)1) vertically drilled

St.deviation [MPa] 6,5 Tested as drilled2)

Density = 2425 kg/m3

9.3 Strength of slab concrete, reference tests

The slabs for the reference tests were taken from the floor test specimen.

9.4 Strength of grout in joints and core filling

#

a

a

a

a mm

Date of test

Note

3 150 25.3.1992 Kept in laboratory in the same Mean strength [MPa] 23,2 (+0 d)1) conditions as the floor specimen St.deviation [MPa] -

9.5 Strength of concrete in end beams

-

1) Date of material test minus date of structural test (floor test or reference test) 2) After drilling, kept in a closed plastic bag until compression

Page 145: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

145

10 Measured displacements Note that the last points on each curve represent the post failure situation.

10.1 Deflections

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16 18 20

Deflection [mm]

P2

[kN

]

5

6

7

8

9

Fig. 27. Deflection on line I, Western end beam.

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16 18 20 22 24

Deflection [mm]

P2

[kN

]

10

11

12

13

14

Fig. 28. Deflection on line II.

Page 146: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

146

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16 18 20 22 24

Deflection [mm]

P2

[kN

]

15

16

17

18

19

Fig. 29. Deflection on line III.

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16 18 20

Deflection [mm]

P2

[kN

]

20

21

22

23

24

Fig. 30. Deflection on line IV, middle beam.

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16 18 20 22 24

Deflection [mm]

P2

[kN

]

25

26

27

28

29

Fig. 31. Deflection on line VI.

Page 147: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

147

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16 18 20 22 24

Deflection [mm]

P2

[kN

]

30

31

32

33

34

Fig. 32. Deflection on line VII.

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16 18 20

Deflection [mm]

P2

[kN

]

35

36

37

38

39

Fig. 33. Deflection on line VIII along Eastern end beam.

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16

Deflection [mm]

P2

[kN

]

West end

Middle

East End

Fig. 34. Stage 1. Net deflection of mid-point of beams (rigid body motion = settlement of beam supports eliminated).

Page 148: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

148

The last measured net deflection of the middle beam before failure was 14,6 mm. Before failure, the net deflection of the middle beam was 1,4 mm and after the highest load level 2,2–2,5 mm greater than that of the end beams.

10.2 Crack width

0

50

100

150

200

250

300

350

0,0 0,5 1,0 1,5 2,0 2,5

Differential displacement [mm]

P2

[kN

]

40

41

42

43

44

45

Fig. 35. Differential displacement ( crack width) measured by transducers 40–46.

10.3 Average strain (actually differential displacement)

0

50

100

150

200

250

300

350

-1,4 -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0

Differential displacement [mm]

P2

[kN

]

50

51

52

53

54

55

Fig. 36. Differential displacement at top surface of floor measured by transducers 50–55.

Page 149: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

149

0

50

100

150

200

250

300

350

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4

Differential displacement [mm]

P2

[kN

] 56

57

58

59

60

61

Fig. 37. Differential displacement at soffit measured by transducers 56–61.

10.4 Shear displacement

0

50

100

150

200

250

300

350

-1,8 -1,6 -1,4 -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2

Differential displacement [mm]

P2

[kN

]

46

47

62

63

Fig. 38. North end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

Page 150: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

150

0

50

100

150

200

250

300

350

-1,8 -1,6 -1,4 -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2

Differential displacement [mm]

P2

[kN

]

48

49

64

65

Fig. 39. South end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

10.5 Strain A gradual growth in the measured strain means that there has been a crack before the loading, most likely attributable to the release of the prestressing force. A sudden increase in crack width indicates a new crack. An example of the former and latter behaviour are illustrated e.g. by transducers 26 and 30, respectively, see Fig. 45.

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 12345

Fig. 40. Strain measured by gauges 1–5.

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

]

678910

Fig. 41. Strain measured by gauges 6–10.

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 1112131415

Fig. 42. Strain measured by gauges 11–15.

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

] 1617181920

Fig. 43. Strain measured by gauges 16–20.

Page 151: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

151

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

]

2122232425

Fig. 44. Strain measured by gauges 21–25.

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

]

2627282930

Fig. 45. Strain measured by gauges 26–30.

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]

P2

[kN

]

3132333435

Fig. 46. Strain measured by gauges 31–35.

0

50

100

150

200

250

300

350

-500 0 500 1000 1500 2000

Strain [10-6 ]P

2 [k

N] 36

37383940

Fig. 47. Strain measured by gauges 36–40.

In Figs 48 and 49 the cracks below the soffit of slabs 2, 3, 6 and 7 are shown.

2

3

6

7

Visible crack

Crack detected by strain gauge

W1

W2

W3

W4

W5W6

W7

W8

W9

W10

W11

W12

W13

W14

W15W16

W17

W18

W19

W20

190

Fig 48. Cracking of bottom surface of hollow core units no 2, 3, 6 and 7 along the strands under force F2 = 153.2 kN. The cracking limit for the strain gauge measurements is 0,03%. The length of the broken line corresponds to the length of the visible crack.

Page 152: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

152

2

3

6

7

Crack detected by strain gauge

W1

W2

W3

W4

W5W6

W7

W8

W9

W10

W11

W12

W13

W14

W15W16

W17

W18

W19

W20

190

Fig. 49. Cracking of bottom surface of hollow core units no 2, 3, 6 and 7 along the strands under force F2 =330 kN.

11 Reference tests

L

P

V

Tie beam1260

4040

Fig. 50. Layout of reference tests on slabs 4 and 8 taken from the floor test specimen. For L, see Table 2.

Page 153: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

153

Table 2. Span L, ultimate load Pu, ultimate shear force Vu and failure mode in reference tests. The weight of the loading equipment = 0,5 kN is included in Pu.

Slab

L mm

Pu

kN

Vu

kN

Failure mode

4 7000 582 499,8 1260

440

Shear tension failure

8 7000 622 532,8 1260350

Shear tension failure

Mean 516,3

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 293,6 kN per one slab unit or 244,7 kN/m. This is 57% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only

(deflection minus settlement of supports) was 14,6 mm or L/342

2. The shear resistance measured in the reference tests was somewhat higher than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005. This may be due to the tie beam which made the shear stresses in the webs more uniform than those in the tests without tie beams.

3. Before failure, the net deflection of the middle beam was 2,2–2,5 mm greater than that of the end beams. This is a too small difference to cause considerable torsional stresses in the slabs.

4. The failure mode was web shear failure of edge slab 5 close to the middle beam. The middle beam seemed to recover completely after the failure.

Page 154: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A154

APPENDIX A: PHOTOGRAPHS

Page 155: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A155

Page 156: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A156

Page 157: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A157

Page 158: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A158

Page 159: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A159

Page 160: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A160

Page 161: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.400.1992

A161

Page 162: Matti Pajari Prestressed hollow core slabs supported on beams ...
Page 163: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

163

1 General information

1.1 Identification and aim

VTT.PC.InvT-Unif.265.1993 Last update 2.11.2010

PC265E (Internal identification)

Aim of the test To study the effect of core filling with length equal to the core height.

1.2 Test type

Prestressed concrete beam

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 18.1.1993

1.4 Test report

Author(s) Pajari, M.

Name 265 mm hollow core floor supported on prestressed concrete beam under evenly distributed load

Ref. number RAT-IR-5/1993

Date 7.3.1993

Availability Public, available on request from VTT Expert Services, P.O. Box 1001, FI-02044 VTT.

Financed by Parma Oy, Finland; Oy Partek Concrete Ab, Finland; Skanska Prefab AB, Sweden and AB Strängbetong, Sweden

2 Test specimen and loading (see also Appendix A)

2.1 General plan

750

375

480

50

6000 50

50750

750

5000

5000

Fig. 2. Plan.

Page 164: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

164

2.2 End beams

240

12

230 7,5

12

Fig. 3. Cross-section of end beam.

Plywood

80 50

30 30Plastic plug

End beam

Tie beamL = 4750

2 T8

265

230

240

HE240A

Fe 52 Fig. 4. Arrangements at end beam. T8 refers to a reinforcing bar with diameter 8 mm, see 2.3.

Simply supported, span = 5,0 m, fy 350 MPa (nominal fy), did not yield in the test.

2.3 Middle beam

Prestressed concrete beam, see Figs 5–7. Concrete: K60 Passive reinforcement and tendons: T8: Hot rolled, weldable rebar A500HW, = 8 mm, see 9.1 J12,5: strand with 7 indented wires, =12,5 mm, Ap = 93 mm2, see 9.1 Tie reinforcement: Straight rebars in the tie beams, across the middle beam and in the longitudinal joints of the slabs, see Figs 4 and 7.

Fig. 5. Middle beam.

55 6 5070 x6x50

4 J 12,5

14 J 12,5

= 1100 MPapo

=1100 MPapo 55

Shear keys 125x125 c/c 300

30

3 holes c/c 1200

15

4645

Fig. 6. Section of middle beam. See also Fig. 7.

Page 165: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

165

2.4 Arrangements at middle beam

- Simply supported, span = 5,0 m - Joints and tie beams grouted on the 17th of December 1992 - The concrete filling in the hollow cores was cast via the end of the slab; neither slots

nor holes in the slab elements were made.

265

502025 55 780

100

48050

150

3 holes c/c 1200

302 T8 L = 5150

Neoprene 20x10

185185

2 T8 L = 5150

40

185

40

265

Mineralwool

3 T8 L=2000c/c 1200

Fig. 7. Section along hollow cores.

2.5 Slabs

1160

40

1200

185 w,ib

35 w,ib = 235

265

40

Fig. 8. Nominal geometry of slab units. Nominal length = 6000 mm.

- 10 slabs extruded 7.12.1992 by Partek Betoniteollisuus Oy, Hyrylä factory,

all from the same casting bed and casting lot - Grade of concrete K60 - 10 lower strands J12,5 initial prestress 1100 MPa - Slabs 1–8 for floor test, slabs 9–10 for reference tests J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2, see 9.1.

115844,2

1194

180,

6 w,ib

41,2 w,ib = 222,438,2

Fig. 9. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 1,8;1,7&1,6; 1,5 and 1,4 mm in slabs 10; 3; 6 and 9, respectively Measured weight of slab units = 4,12 kN/m

2.6 Temporary supports

- No

Page 166: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

166

2.7 Loading arrangements

64 short I-beams (primary spreader beams) were placed on the floor as shown in Fig. 10. The length of these beams was 550 mm. There was gypsum mortar between the slabs and the floor to smoothe the uneven top surface of the slabs. The loads from 16 actuators were distributed to the primary beams with the aid of 16 tertiary spreader beams and 32 secondary spreader beams as shown in Fig. 10. To eliminate the contribution of the loading equipment to the load-carrying mechanism of the floor, two teflon plates were placed below one end of each secondary and tertiary beam, see Appendix A, Figs 2 and 3. The actuators were connected to three hydraulic circuits which were controlled separately to create the same force in each actuator. Eight of them (P1 and P2) were of long type with a swivel at both ends, eight (P3) were of short type with a swivel on the top. Attempts were made to keep all actuator forces equal during the test. The total imposed load due to the actuator force Pi and weight of underlying loading equipment was F1 = P1 + 1,4 kN F2 = P2 + 1,4 kN F3 = P3 + 1,8 kN

375

750

375

375

375

375

480

506000 50

5050

00

A A

A A

2 + 23

PP1+ 23

P2P1+23

P2

P 2 + 23

P2

P2

PrimarySecondary

Tertiary

P1 P1 2P

2P

3P

3P

3P

3P

3P

3P

3P

3P

P1 P1 2P

2P

Fig. 10. Plan. P1, P2

and P3 refer to vertical actuator forces.

Page 167: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

167

3 Measurements

3.1 Support reactions 1

5

3 loadcells

Sou

th

Fig. 11. Load cells below the South end of the middle beam.

3.2 Vertical displacement

4

5

8 4

3

2

1

19

18

29

25

6

7

I II

III

IV V

3000 30003000

5000

10

6

7

8

9

11

12

13

14

5 15

16

17

20

21

22

23

24

26

27

28

3000

6000 6000

3030

North

South

Fig. 12. Location of transducers 5 … 29 for measuring vertical deflection along lines I … V.

3.3 Average strain

5

6

7

8

47 46(62)(63)

48(65) (64)49

50 50

1

2

3

4

(61)

54(60)

53(59)

52(58)

(57)

50(56)

5155

150

North

South

L

TransducerSteel bar

Fig. 13. Apparatus for measuring average strain. L =1120mm and 1060 mm for the bottom and top side transducers, respectively.

Fig. 14. Position of device (transducers 50–61) measuring average strain parallel to the beams. Transducers 46–49 and 62–65 measured the sliding of the outermost slabs along the beam. Numbers in parentheses refer to the soffit of the floor, others to the top.

Page 168: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

168

3.4 Horizontal. displacements

5

6

7

8

1

2

3

4

North

South

41 40

43

45 44

42

Fig. 15. Position of transducers 40–45 measuring crack width.

3.5 Strain

4 Special arrangements

-

5 Loading strategy

5.1 Load-time relationship

Date of test was 18.1.1993. When the actuator forces Pi were equal to zero but the weight of the loading equipment was on, all measuring devices were zero-balanced. The loading history is shown in Fig.16. Note, that the number of load step, not the time, is given on the horizontal axis. The whole load test took two hours and five minutes. In the following, the cyclic stage (steps 0–16) is called Stage I, the monotonous stage from increment 16 to failure is called Stage II.

0

10

2030

40

50

6070

80

90

0 10 20 30 40 50

Load step [mm]

Pi [

kN]

P1

P2

P3

Fig. 16. Development of actuator forces P1, P2 and P3.

Page 169: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

169

5.2 After failure

6 Observations during loading

Stage I -

Stage II At Pi = 40 kN soffit of the middle beam cracked. At Pi = 45 kN cracks in the corners of slabs 2 and 7 as well as a longitudinal crack along a hollow core in the soffit of slab 3 were observed, see Figs 17 and 18. At Pi = 75 kN one corner of slab 4 cracked as shown in App. A, Fig. 6. When increasing the loads, diagonal shear cracks appeared in the webs of slab units; first in slab 4 (Figs. 7 and 8 in App. A), then in slab 8 (Figs 15 and 16 in App. A) and finally also in slab 1 (Fig. 17 in App. A). At P1 = 90,0 kN, P2 = 87,6 kN P3 = 86,8 kN a web shear failure took place in slab 4 close to the middle beam. The cracking patterns after the failure are shown in Figs 17 and 18 and in App. A, Figs 9–18 and 21–23.

After failure

When demolishing the test specimen it was observed that all core fillings were perfect, see App. A, Figs 19–20.

7 Cracks in concrete

7.1 Cracks at service load

7.2 Cracks after failure

The vertical cracking in the joint concrete next to the middle beam typically took place along the edges of the middle beam, not along the joint concrete or along the slab ends.

1

44

P = 75 kNi

3

4

1

2

7

8

5

6

Fig. 17. Cracks after failure on the top and at the edges.

Page 170: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

170

Pi=45kN

?7

8

5

6

3

4

1

2

Fig. 18. Cracks after failure in the soffit.

8 Observed shear resistance

The maximum support reaction is regarded as the indicator of failure. The failure took place when P1 = 90,0 kN, P2 = 87,6 kN P3 = 86,8 kN or when the sum of actuator loads load on half floor was = 702,4 kN.

Fig. 19 shows the relationship between the measured support reaction below the South end of the middle beam and the sum of actuator loads on half floor. The ratio of the reaction to the load is shown in Fig. 20 and in Fig. 21 in a larger scale. Assuming simply supported slabs the ratio = 0,756 is obtained, and the measured support reaction seems to follow this assumption well until at load 646 kN (Pi = 80 kN) the sudden softening of slab 4 at the North end of the middle beam resulted in load transfer from the North to the South end of the middle beam. At failure the ratio equalled 0,78, but the failure took place at the opposite (North) end of the beam where the support reaction must have been lower. For this reason it seems justified to use the value of 0,756 for calculation of the shear resistance.

0

100

200

300

400

500

600

0 100 200 300 400 500 600 700 800

Load on half floor [mm]

Rea

ctio

n [k

N]

Fig. 19. Support reaction measured below South end of the middle beam vs. load on half floor = 2(P1 + P2 ) + 4 P3.

Page 171: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

171

0,00,10,20,30,40,50,60,70,80,91,0

0 100 200 300 400 500 600 700 800

Load on half floor [kN]

Rea

ctio

n /

Lo

ad o

n h

alf f

loo

r

Fig. 20. Ratio of measured support reaction (below South end of the middle beam) to load on half floor.

0,75

0,76

0,77

0,78

0,79

0 100 200 300 400 500 600 700 800

Load on half floor [kN]

Rea

ctio

n /

Lo

ad o

n h

alf f

loo

r

Fig. 21. A part of the previous figure in a large scale. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of topping concrete, weight of loading equipment and actuator forces Pi, respectively. The shear force at failure is calculated assuming that the slabs behave as simply supported beams. For Veq and VP this means that Veq = 0,756x(8x1,4 +8 x1,8)/8 = 2,4 kN and Vp = 0,756x(4xP1 + 4xP2 +8xP3)/8. Vg,jc is calculated from the nominal geometry of the joints and measured density of the concrete, other components of the shear force are calculated from measured loads and weights. The values for the components of the shear force are given in Table on the next page.

Page 172: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

172

Table. Components of shear resistance due to different loads.

Action Load Shear force

kN

Weight of slab unit 4,117 kN/m 12,2

Weight of joint concrete 0,11 kN/m 0,3

Loading equipment 3,2 kN 2,4

Actuator loads (4x90,0+4x87,6+8x86,8)/8 kN 132,7

The observed shear resistance Vobs = 147,6 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 123,0 kN/m.

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

End beams 350 Nominal (Fe 52)

Slab strands J12,5 >1570 >1770 Nominal (no yielding in test)

Beam strands J12,5 >1570 >1770 Nominal (may have yielded in test)

Reinforcement Txy 500 Nominal value for reinforcing bars A500HW (no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 25.01.1993 Upper flange of slab 4,

Mean strength [MPa] 72,9 (+7 d)1) tested as drilled2)

St.deviation [MPa] 4,5 Density = 2440 kg/m3

9.3 Strength of slab concrete, reference tests

Not measured, assumed to be the same as that in the floor test.

9.4 Strength of grout in longitudinal joints of slab units

#

a

a

a

a mm

Date of test

Note

3 150 18.1.1993 Kept in laboratory in the same

Mean strength [MPa] 31,3 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,76 Density = 2150 kg/m3

Page 173: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

173

9.5 Strength of concrete in the middle beam

#

a

a

a

a mm

Date of test

Note

6 150 25.1.1993 Kept in laboratory in the same

Mean strength [MPa] 68,6 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 3,30 Density = 2403 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

10 Measured displacements

In the following figures, F stands for the average actuator load + the average weight of loading equipment per actuator.

10.1 Deflections

0

10

2030

40

50

6070

80

90

0 5 10 15 20 25 30 35 40 45

Deflection [mm]

F [k

N]

5

6

7

8

9

Fig. 22. Deflection measured by transducers 5–9.

0

10

2030

40

50

6070

80

90

0 5 10 15 20 25 30 35 40 45

Deflection [mm]

F [k

N]

10

11

12

13

14

Fig. 23. Deflection measured by transducers 10–14.

Page 174: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

174

0

10

2030

40

50

6070

80

90

0 5 10 15 20 25 30 35 40 45

Deflection [mm]

F [k

N]

15

16

17

18

19

Fig. 24. Deflection measured by transducers 15–19.

0

10

2030

40

50

6070

80

90

0 5 10 15 20 25 30 35 40 45

Deflection [mm]

F [k

N]

20

21

22

23

24

Fig. 25. Deflection measured by transducers 20–24.

0

10

2030

40

50

6070

80

90

0 5 10 15 20 25 30 35 40 45

Deflection [mm]

F [k

N]

25

26

27

28

29

Fig. 26. Deflection measured by transducers 25–29.

Page 175: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

175

0

10

2030

40

50

6070

80

90

0 5 10 15 20 25 30 35 40 45

Net deflection [mm]

F [k

N] 7

27

17

Fig. 27. Net mid-point deflection (measured deflection – settlement of supports) for end beams (7 and 27) and middle beam (17).

10.2 Crack width

0

10

2030

40

50

6070

80

90

0 5 10 15 20 25

Differential displacement [mm]

F [k

N]

40

41

42

43

44

45

Fig. 28. Differential displacement ( crack width) measured by transducers 40–45, see Fig. 15.

0

10

2030

40

50

6070

80

90

0 1 2 3 4 5

Differential displacement [mm]

F [k

N]

40

41

42

43

44

45

Fig. 29. A part of the previous figure in a larger scale.

Page 176: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

176

10.3 Average strain (actually differential displacement)

0

10

2030

40

50

6070

80

90

-3,0 -2,5 -2,0 -1,5 -1,0 -0,5 0,0 0,5

Differential displacement [mm]

F [k

N]

50

51

52

53

54

55

Fig. 30. Differential displacement measured by transducers 50–55, see Fig. 12.

0

10

2030

40

50

6070

80

90

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0

Differential displacement [mm]

F [k

N]

56

57

58

59

60

61

Fig. 31. Differential displacement measured by transducers 56–61, see Fig. 12. To get a rough estimate of the strains before failure, the measured results on the top and at the bottom of the middle beam are shown in Fig. 32. The displacements were actually measured 10–20 mm outside the top and bottom surface of the floor but this is ignored in Fig. 32.

Page 177: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

177

52 53

57

56

59

265

0.51.01.52.02.53.03.5 0.0 -0.5 -1.0-1.5 -2.0

100

-2.5 -3.04.0

5450

51

61

60

DIFFERENTIAL DISPLACEMENT [mm]

58

10

Beam

Slabs

4.5

10

Fig. 32. Differential displacement measured by transducers 50–61 at failure. The values measured on the top and at the bottom are connected with a straight line. Dividing the values given in Fig. 32 on the top by 1060 mm and those at the bottom by 1120, the value of average strain is obtained. Multiplying the average strain by 1,07, the strain change at the mid-section of the beam due to the actuator loads is obtained. Hence, the change in concrete strain on the top of the beam is

%26,007,11060/55,2c

and the change in the stress of the lower tendons of the beam is

580MPa1,073,2/1120(190GPa)E ppp

Taking into account the low prestress level 1100 MPa, the losses of prestress, the elastic deformation due to the release of the prestressing force as well as the short span of the beam and the low self-weight of the slabs, it is clear that the stress in the lowest tendons must have been below 1000 MPa before the actuator loads were applied. This means that the stress in the tendons must have been of the order of yield stress or a bit lower. It can also be concluded that the compression zone of the beam could still carry a higher load. So, the yielding of the beam could not be the reason to the failure.

10.4 Shear displacement

0

10

2030

40

50

6070

80

90

-14 -12 -10 -8 -6 -4 -2 0

Differential displacement [mm]

F [k

N]

46

47

48

49

Fig. 33. Sliding of upper edge of slabs 1, 4, 5 and 8 along middle beam, see Fig. 12.

Page 178: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

178

0

10

2030

40

50

6070

80

90

-2,0 -1,5 -1,0 -0,5 0,0

Differential displacement [mm]

F [k

N]

46

47

48

49

Fig. 34. A part of the previous figure in a larger scale.

0

10

2030

40

50

6070

80

90

-1,5 -1,0 -0,5 0,0 0,5 1,0

Differential displacement [mm]

F [k

N]

62

63

64

65

Fig. 35. Sliding of lower edge of slabs 1, 4, 5 and 8 along middle beam. Cracking of the corner of slab 4 at F = 70 kN makes the curve of transducer 62 meaningless after that point. The curve of transducer 63 seems to be incorrect from the beginning.

Page 179: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

179

0

10

2030

40

50

6070

80

90

-1,0 -0,8 -0,6 -0,4 -0,2 0,0

Shear displacement [mm]

F [k

N]

46-62, slab 4

47-63, slab 8

48-64, slab1

49-65, slab 5

Fig. 36. Shear displacement (= differential displacement between upper and lower edge of slabs 1, 4, 5 and 8) in beam's direction, see Fig. 12. After F = 70 kN the curve for slab 4 reflects primarily the rigid body motion of a loose piece of concrete. Due to the errors in transducer 63, the curve for slab 8 has no physical meaning. Fig. 36 shows that the core filling could not totally eliminate the transverse horizontal shear deformation of the slab ends.

10.5 Strain -

11 Reference tests

Two tests were carried out: R9 (slab 9) and R10 (slab 10).

375

750

375

375

375

375

6000

P P

P P

1 2 3

456

7

8

1 (6) 2 (5) 3 (4)

7 (8)Teflon

Teflon

30303030 6000

1200a)

b)

Fig. 37. Layout of reference test. a) Plan. b) Elevation. There was gypsum mortar between the lowest spreader beams ant the top surface of the slab. Transducers 1–6 measured vertical displacement of the top surface, transducers 7 and 8 the slippage of the outermost strands.

Page 180: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

180

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35 40 45

Load step [mm]

P [k

N]

R9

R10

Fig. 38. Loading.

Bending crack

Failure crack

R9:Failure crack

R10:

Fig. 39. Failure modes in reference tests. The bending crack in test R9 did not contribute to the actual failure. See also Appendix A, Figs 24–28.

0

20

40

60

80

100

120

140

160

180

0 10 20 30 40 50 60 70

Deflection [mm]

P [k

N]

R9

R10

Fig. 40. Midpoint deflection from which the rigid body motion due to the settlement of the supports has been eliminated. P is the actuator force.

Page 181: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

181

0

20

40

60

80

100

120

140

160

180

0 1 2 3 4

Slippage [mm]

P [k

N]

R9/7

R9/8

R10/7

R10/8

Fig. 41. Slippage of outermost strands measured by transducers 7 and 8.

0

20

40

60

80

100

120

140

160

180

0,00 0,02 0,04 0,06 0,08 0,10 0,12 0,14

Bond slip [mm]

P [k

N]

R9/7

R9/8

R10/7

R10/8

Fig. 42. A part of the previous figure in a larger scale. Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force P at failure, weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span

mm

Vg

kN

P

kN

Peq

kN

Vobs

kN

vobs

kN/m Note

R9 22.1.2002 5940 12,2 155,6 1,4 248,5 196,9 Web shear failure

R10 22.1.2002 5940 12,2 160,0 1,4 255,1 212,5 Flexural shear failure

Mean 251,8 209,8

Page 182: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

182

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 147,6 kN per one slab unit or 123,0 kN/m. This is 59% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The failure mode was web shear failure of edge slabs. The prestressed

concrete beam seemed to recover completely after the failure.

2. The obtained shear resistance was 43% higher than that observed in test VTT.PC.InvT.265.1990. The filled hollow cores and the uniformly distributed load over half floor made the difference in the present test. It is difficult to say, to which extent the enhanced resistance was attributable to each of these differences.

3. The net deflection of the middle beam due to the imposed actuator loads (deflection minus settlement of supports) was 39 mm or L/128. It was 17–19 mm greater than the deflection of the end beams. Hence, the torsion due to the different deflection of the middle beam and end beams has to be taken into account when analyzing the test result.

4. The measured strains on the top and at the bottom of the middle beam suggest that the middle beam was not yielding when the failure took place.

Page 183: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A183

APPENDIX A: PHOTOGRAPHS

Page 184: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

A184

Page 185: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A185

Page 186: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

A186

Page 187: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A187

Page 188: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

A188

Page 189: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A189

Page 190: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

A190

Page 191: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A191

Page 192: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

A192

Page 193: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A193

Page 194: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

A194

Page 195: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A195

Page 196: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Unif.265.1993

A196

Page 197: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.InvT-Unif.265.1993

A197

Page 198: Matti Pajari Prestressed hollow core slabs supported on beams ...
Page 199: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

199

1 General information

1.1 Identification and aim

VTT.PC.InvT-Topp.265.1993 Last update 2.11.2010

PC265T (Internal identification)

Aim of the test To study the effect of reinforced concrete topping on the shear resistance of hollow core slabs supported on a beam. A prestressed concrete beam was chosen because, according to previous tests, the interaction between the slabs and concrete beam was stronger than with steel beam.

1.2 Test type

Prestressed concrete beam

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 11.10.1993

1.4 Test report

Author(s) Koukkari, H.

Name Loading test on 265 mm hollow core floor with topping supported on prestressed concrete beam

Ref. number RAT-IR-19/1993

Date 15.12.1993

Availability Public, available on request from VTT Expert Services, P.O. Box 1001, FI-02044 VTT.

Financed by Finnish Association of Building Industry RTT, the Inter-national Prestressed Hollow Core Association IPHA, KB Kristianstads Cementgjuteri, Sweden, Skanska Prefab AB, Sweden

2 Test specimen and loading (see also Appendix A)

2.1 General plan

See Figs 1 and 10 and Appendix A, Figs 3 and 4.

2.2 End beams

240

12

230 7,5

12

Fig. 2. Cross-section of end beam.

Fig. 3. Arrangements at end beam. T8 refers to a reinforcing bar with diameter 8 mm, see 2.3.

Page 200: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

200

Simply supported, span = 5,0 m

2.3 Middle beam

Prestressed concrete beam, see Figs 4–6 and Appendix A Concrete: K60 Passive reinforcement and tendons: Txy: Hot rolled, weldable rebar A500HW, = xy mm, see 9.1 J12,5: strand with 7 indented wires, =12,5 mm, Ap = 93 mm2 B5: Cold formed rebar B500K, = 5 mm, see 9.1

Tie reinforcement: Straight rebars in the tie beams, across the middle beam and in the longitudinal joints of the slabs, see Figs 3 and 6.

Fig. 4. Middle beam.

55 6 5070 x6x50

4 J 12,5

14 J 12,5

= 1100 MPapo

=1100 MPapo 55

Shear keys 125x125 c/c 300

30

3 holes c/c 1200

15

4645

Fig. 5. Section of middle beam. See also Fig. 6.

2.4 Arrangements at middle beam

- Simply supported, span = 5,0 m - Joints and tie beams grouted on the 24th of September 1993 - The top surface of the slab units and the middle beam were cleaned and moistened

before casting the topping concrete on the 29th of September 1993 - No special measures to enhance the bond between the topping and the underlying

concrete

Page 201: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

201

265

50202555 780

100

48050

150

302 T 8 L = 5150

Neoprene 20x10 3T 8 L=2000c/c 1200

50

2 T8 L = 5150

40

18

540

Plastic plug

50

Topping concrete K40

Mesh reinforcement B5 #150

60

Fig. 6. Section along hollow cores.

4

5

8 4

3

2

1

6

7

I

5000

Fig. 7. Overlapping of mesh reinforcement.

2.5 Slabs

1160

40

1200

185 w,ib

35 w,ib = 235

265

40

Fig. 8. Nominal geometry of slab units. - Extruded 15.9.1993 by Partek Oy, Hyrylä factory, grade of concrete K60 - 10 lower strands J12,5 initial prestress 950 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2, see 9.1.

Page 202: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

202

116244,3

119417

9,1 w,ib

34,2 w,ib = 22238,8

Fig. 9. Mean of most relevant measured geometrical characteristics, slabs 1–8.

Max measured bond slips: 2,0 in slab 7; 1,8 in slab 10 and 1,6 in slab 4, Measured weight of slab units = 4,18 kN/m

2.6 Temporary supports

-

2.7 Loading arrangements

There were two separate hydraulic circuits, one for actuator loads P1 and the other for actuator loads P2. See Fig. 10 and App. A, Figs 3 and 4 for the loading arrangements.

Fig. 10. Plan. P1 and P2 refer to vertical actuator forces. det 1: roller bar, det 2: hinge. The thickness of the topping was 60 mm in those corners of slabs 1, 4, 5 and 8 which where on the South and North edge of the floor specimen.

Page 203: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

203

Gypsum

Teflon plates

P Steel platesF

2F

550F

F

Fig. 11. Bearing above the spreader beams on slabs 1, 4, 5 and 8. The hydraulic actuators (P2) prevented the lateral motion of the square steel tube beams (see App. 1, Figs 3 and 4) and the friction at the ends was eliminated by teflon plates.

3 Measurements

3.1 Support reactions

The support reaction due to the actuator loads below the Southern end of the middle beam was measured by three load cells, see Fig. 12.

1

5

3 loadcells

Sou

th

Fig. 12. Load cells below one end of the middle beam.

3.2 Vertical displacement

4

5

8 4

3

2

1

19

18

29

25

6

7

I IIIII IV V

3000 3000

5000

106

7

8

9

11

12

13

14

5 15

16

17

2021

22

23

24

26

27

28

2970

597030

30 2970 30

5970 30

South

North

Fig. 13. Location of transducers 5–29 for measuring vertical deflection along lines I–V.

3.3 Sliding of slab (horizontal displacement)

The sliding of the slab ends along the middle beam was measured using eight transducers (46–48 & 62–65). Their position is shown in Fig. 16. See also Figs 7 and 10–13 in App. A.

Page 204: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

204

3.4 Crack width (horizontal displacement)

The differential displacement reflecting the width of vertical cracks in the topping was measured by six transducers located as shown in Fig. 14.

Fig. 14. Transducers (40–45) measuring crack width between the middle beam and the slab ends.

3.5 Average strain Average strain was measured using 12 devices of the type shown in Fig. 15. See Fig 16

for the position of the transducers.

L

TransducerSteel bar

Fig. 15. Apparatus for measuring average strain. L = 1120mm and 1060 mm for the top and soffit transducers (50–55 and 56–61), respectively.

Fig. 16. Position of transducers 50–61 measuring average strain parallel to the beam and position of transducers 46–48 & 62–65 measuring sliding of slabs along the beam. The numbers in parentheses refer to lower transducers.

Page 205: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

205

4 Special arrangements

- none

5 Loading strategy

5.1 Load-time relationship

The date of the floor test was 11.10.1993 The imposed load Fi on each hollow core slab was equal to Pi + Peq, i where Pi is the actuator load P1 or P2 shown in Fig. 10 and Peq,i the load due to the self weight of the loading equipment. So

F1 = P1 + 1,2 kN for slab units 2, 3, 6 and 7 F2 = P2 + 5,6 kN for slab units 1, 4, 5 and 8

When the actuator forces Pi were equal to zero but the weight of the loading equipment was on, all measuring devices were zero-balanced. The loading history is shown in Fig.17. Note, that the number of load increment, not the time, is given on the horizontal axis. The whole test took roughly two hours. In the following, the cyclic stage (increments 0–16) is called Stage I, the monotonous stage from increment 16 to failure is called Stage II.

0

20

40

60

80

100

120

140

160

0 10 20 30 40 50

Number of load increment

F [k

N]

F1

F2

Fig. 17. Loading history.

5.2 After failure

Page 206: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

206

6 Observations during loading

Pi kN

Observations Cracking pattern

55 (1)

Vertical cracks in the flange of the middle beam, under slab 6

topp ing

flan ge

55 (1)

Vertical cracks in the longitudinal edges of the topping, above the middle beam

ends 5 1

55(1)

One vertical crack in the tie beam, above the end beam

topp ingtie beam

H E-beam

55(3)

Several vertical cracks in the middle beam ends

55(5)

A vertical crack in the longitudinal edge of the topping

5 1

60

Cracking in the middle beam flange grew down to the bottom of the middle beam

to p pin g

flange

80

Cracks on the surface of the topping along the joint between the middle beam

and slabs 1–4

see Fig. 18

80

A transverse crack in the soffit of the middle beam

5 6

2

m id d le be ambottom o f

90 The cracks in the end tie beams reached the surface ot the topping

90

A vertical crack in the longitudinal edge of the topping starting from the corner of the

middle beam 4 8

Pi =55 kN

100 A vertical crack in the concrete tie beam, between slabs 5 and 6

100

A vertical crack in the joint between slab 1 and the middle beam, next to the beam 5 1

Page 207: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

207

110

A vertical crack in the joint between the slab 5 and the middle beam,

next to the beam 5 1

115

A vertical crack in the longitudinal edge of the topping starting from the corner of the

middle beam 5 1

115

The concrete topping became loose above the middle beam, between slabs

1 and 5 5 1

120 Diagonal cracks developed in edges of slabs 1 and 4 near the middle beam and a vertical crack along the ends of slabs 5–8 appeared in the topping. After a while diagonal cracks developed in edges of slabs 5 and 8 near the middle beam.

135 A shear failure took place in slabs 4 and 8.

7 Cracks in concrete

7.1 Cracks at service load

7.2 Cracks after failure

8

7

6

5 1

2

3

4

1000

8

1000

4

10001000

15

Fig. 18. Cracks after failure on the top and at the edges.

Page 208: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

208

8

7

6

5 1

2

3

4

Fig. 19. Cracks after failure in the soffit.

8 Observed shear resistance

The maximum support reaction is regarded as the indicator of failure.

0

50

100

150

200

250300

350

400

450

500

0 100 200 300 400 500 600

Load on half floor [kN]

Rea

ctio

n [k

N]

Fig. 20. Support reaction measured below South end of the middle beam vs. load on half floor = 2(P1 + P2).

Page 209: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

209

0,00,10,20,30,40,50,60,70,80,91,0

0 100 200 300 400 500 600

Load = 2(P1+P2) [kN]

Re

act

ion

/ L

oa

d

Monotonous

Cycle 1

Fig. 21. Ratio of measured support reaction (below South end of the middle beam) to load on half floor = 2(P1 + P2). The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Vg,top + Veq + Vp

where Vg,sl, Vg,jc, Vg,top, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of topping concrete, weight of loading equipment and actuator forces Pi, respectively. The shear force due to the the self-weight of the structure is calculated assuming that the slabs behave as simply supported beams. Veq and VP are calculated using the measured relationship between the support reaction of the beam and the loads. This means that Veq = 0,883xPeq and Vp = 0,883x(P1.+ P2)/2. Vg,jc and Vg,top are calculated from the nominal geometry of the joints, nominal thickness 60 mm of the topping and measured density of the concrete, other components of the shear force are calculated from measured loads and weights. The values for the components of the shear force are given in Table below. Table. Components of shear resistance due to different loads.

Action Load Shear force

kN

Weight of slab unit 4,18 kN/m 12,4

Weight of joint concrete 0,11 kN/m 0,3

Loading equipment (1,2+5,6)/2 kN 3,0

Weight of topping 1,58 kN/m 4,7

Actuator loads 271,6 (135,4+136,3)/2 kN 119,9

The observed shear resistance Vobs = 140,3 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 116,9 kN/m

Page 210: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

210

9 Material properties

9.1 Strength of steel:

ReH/Rp0,2 Rm Component

MPa MPa Note

End eams 350 Nominal (Fe 52, no yielding in test)

Strands J12,5 >1570 >1770 Nominal (no yielding in test)

Reinforcement B5 500 Nominal (B500K)

Reinforcement T8 500 Nominal (A500HW)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 25.10.1993 Upper flange of slabs 1, 3 & 8, two pc. from each

Mean strength [MPa] 78,2 (+14 d)1) Vertically drilled

St.deviation [MPa] 4,3 Tested as drilled2) Density = 2417 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 25.10.1993 Upper flange of slab9

Mean strength [MPa] 72,0 (+14 d)1) Vertically drilled

St.deviation [MPa] 4,9 Tested as drilled2) Density = 2407 kg/m3

9.4 Strength of grout in longitudinal joints of slab units and tie beams

#

a

a

a

a mm

Date of test

Note

2 150 11.10.1993 Kept in laboratory in the same

Mean strength [MPa] 29,3 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] Density = 2200 kg/m3 #

Cores h

d

h mm

d mm

Date of test

Note

3 50 50 25.10.1993 Vertically drilled

Mean strength [MPa] 33,8 (+14 d)1) Tested as drilled2)

St.deviation [MPa] 4,6 Density = 2147 kg/m3

Page 211: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

211

9.5 Strength of concrete in the topping

#

a

a

a

a mm

Date of test

Note

2 150 11.10.1993 Kept in laboratory in the same

Mean strength [MPa] 29,3 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] Density = 2200 kg/m3

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 25.10.1993 Vertically drilled

Mean strength [MPa] 34,2 (+14 d)1) Tested as drilled2)

St.deviation [MPa] 1,25 Density = 2200 kg/m3

9.6 Strength of concrete in the middle beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 75 75 25.10.1993 Vertically drilled

Mean strength [MPa] 62,9 (+14 d)1) Tested as drilled2)

St.deviation [MPa] 3,6 Density = 2387 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

10 Measured displacements

In the following figures, F2 = P2 +5,6 kN is the line load on slabs 1, 4, 5 and 8 due to actuator force P2 and weight of loading equipment. Note that the last six points on each curve represent the post failure situation.

Page 212: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

212

10.1 Deflections

0

20

40

60

80

100

120

140

160

0 2 4 6 8 10 12

Deflection [mm]

F2

[kN

] 5

6

7

8

9

Fig. 22. Deflection measured by transducers 5–9.

0

20

40

60

80

100

120

140

160

0 4 8 12 16 20

Deflection [mm]

F2

[kN

] 10

11

12

13

14

Fig. 23. Deflection measured by transducers 10–14.

Page 213: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

213

0

20

40

60

80

100

120

140

160

0 2 4 6 8 10 12 14 16 18 20

Deflection [mm]

F2

[kN

] 15

16

17

18

19

Fig. 24. Deflection measured by transducers 15–19.

0

20

40

60

80

100

120

140

160

0 4 8 12 16 20

Deflection [mm]

F2

[kN

] 20

21

22

23

24

Fig. 25. Deflection measured by transducers 20–24.

Page 214: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

214

0

20

40

60

80

100

120

140

160

0 4 8 12 16 20

Deflection [mm]

F2

[kN

] 25

26

27

28

29

Fig. 26. Deflection measured by transducers 25–29.

0

20

40

60

80

100

120

140

160

0 2 4 6 8 10 12 14 16

Net deflection [mm]

F2

[kN

]

7

17

27

Fig. 27. Net mid-point deflection (measured deflection – settlement of supports) for end beams (7 and 27) and middle beam (17).

Page 215: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

215

10.2 Crack width

0

20

40

60

80

100

120

140

160

0 0,2 0,4 0,6 0,8 1

Differential displacement [mm]

F2

[kN

] 40

41

42

43

44

45

Fig. 28. Differential displacement ( crack width) measured by transducers 40–45, see Fig. 14.

10.3 Average strain (actually differential displacement)

0

20

40

60

80

100

120

140

160

-1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0

Differential displacement [mm]

F2

[kN

] 50

51

52

53

54

55

Fig. 29. Differential displacement measured by transducers 50–55, see Fig. 16.

Page 216: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

216

0

20

40

60

80

100

120

140

160

-0,5 0,0 0,5 1,0 1,5 2,0

Differential displacement [mm]

F2

[kN

]56

57

58

59

60

61

Fig. 30. Differential displacement measured by transducers 56–61, see Fig. 16.

10.4 Sliding of slab along middle beam

A negative value means that the slab is moving towards the end of the beam.

0

20

40

60

80

100

120

140

160

-2,0 -1,5 -1,0 -0,5 0,0 0,5 1,0 1,5 2,0

Differential displacement [mm]

F2

[kN

]

46

47

48

49

Fig. 31. Sliding of upper edge of slabs 1, 4, 5 and 8 along middle beam, see Fig. 16. No explanation for the positive values of 46 and 47 could be given after the test.

Page 217: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

217

0

20

40

60

80

100

120

140

160

-3,5 -3,0 -2,5 -2,0 -1,5 -1,0 -0,5 0,0 0,5

Differential displacement [mm]

F2

[kN

]

62

63

64

65

Fig. 32. Sliding of lower edge of slabs 1, 4, 5 and 8 along the middle beam, see Fig. 16.

10.5 Strain -

11 Reference tests

Both ends of slabs 9 and 10 were loaded. The results of slab 10 have been ignored because the slab was not cast on the same bed as slabs 1–9.

P

P

1 2 3

456

7

8

1 (6) 2 (5) 3 (4)

7 (8)

Gypsum

30L

1300

L/230 30 30

Fig. 33. Layout of reference test. a) Plan. b) Elevation. For L, see the next Table.

Page 218: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

218

Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure, weight of loading equipment Peq, total shear force (support reaction) Vobs at failure and total shear force vobs per unit width.

Test Date Span L

mm Vg kN

Pa kN

Peq kN

Vobs kN

vobs kN/m

Note

R9/1 19.10.1993 5940 12,4 233,7 0,7 208,5 173,8 Web shear failure

R9/2 19.10.1993 4940 9,9 209,3 0,7 178,6 148,8 Web shear failure

Mean 193,6 161,3

12 Comparison: Floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 140,3 kN per one slab unit or 116,9 kN/m. This is 72% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The failure mode was web shear failure of edge slabs. The prestressed

concrete beam seemed to recover completely after the failure.

2. The net deflection of the middle beam due to the imposed actuator loads (deflection minus settlement of supports) was 13,8 mm or L/360, i.e. rather small. It was 4,3–4,8 mm greater than that of the end beams. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a minor or negligible effect on the failure of the slabs.

3. The mean of shear resistances measured in the reference tests was roughly 10% lower than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005.

4. The topping concrete above the middle beam became loose at one end of the middle beam when the imposed load was 85% of the failure load. The failure took place at the opposite side

5. Comparing the deflection of the middle beam in the present test with that in test VTT.PC.InvT-Unif.265.1993 suggests that the middle beam was still far from yielding when the failure took place.

Page 219: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A219

APPENDIX A: PHOTOGRAPHS

Page 220: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A220

Page 221: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A221

Page 222: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A222

Page 223: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A223

Page 224: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A224

Page 225: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A225

Page 226: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A226

Page 227: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A227

Page 228: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A228

Page 229: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A229

Page 230: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT-Topp.265.1993

A230

Page 231: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

231

1 General information

1.1 Identification and aim

VTT.PC.Rect-norm.265.1993 Last update 2.11.2010

PC265N (Internal identification)

Aim of the test To study the shear resistance of hollow core slabs supported on the top of beam.

1.2 Test type

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 14.12.1993

1.4 Test report

Author(s) Koukkari, H. & Pajari, M.

Name Loading test on 265 mm hollow core floor supported on prestressed concrete beam

Ref. number RAT-IR-20/1993

Date 15.2.1994

Availability Public, available on request from VTT Expert Services, P.O. Box 1001, FI-02044 VTT

Financed by the Finnish Association of Building Industry RTT (supported by the Technology Development Centre of Finland); the International Prestressed Hollow Core Association IPHA; KB Kristianstads Cementgjuteri, Sweden and Skanska Prefab AB, Sweden

2 Test specimen and loading (see also photographs in Appendix A)

2.1 General plan

Page 232: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

232

6000

95 5000

905

905

290

1234

5678

95

1000

5000

1200120012001200

Nor

th

Sou

th

Fig. 2. Plan.

Page 233: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

233

2.2 End beams

I-beams made of steel. Span = 5,0 m

1200 1001300

5200

HE 240 ASteel Fe 52

100 13001200

A

A

A A

24012

2067,5

5 stiffening plates, thickness = 10 mm

12

Fig. 3. End beam.

Plywood

80 50

30 30

Plastic plug

End beam

Tie beam

L = 4750 2 T8

265

230

240

HE240A

Fe 52

Fig. 4. Arrangements at end beam. T8 refers to a reinforcing bar, see 2.4.

2.3 Middle beam

The middle beam was a composite beam comprising a precast, prestressed concrete beam and a cast-in-situ component. The grade of the concrete was K60 in the lower, precast part and K30 in the upper part. See Figs 5 and 6 for the main characteristics of the beam.

Page 234: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

234

180

50 75 50 50505050 52,552,5

4645

16 J12,5

po = 1100 MPa

150150

230

380

350

5400

A

A - AHoop

Hoops5 H8 c/c 200

21001200

22 H8 c/c 100

2100

neopren10 x 20

22 H8 c/c 100

Fig. 5. Middle beam. Main reinforcements and hoops. H8 and J12,5 refer to rebar hoops and prestressing strands with diameter 8 and 12,5 mm, respectively, see 9.1.

2.4 Arrangements at middle beam

601520

380

290

50

4 T8 L = 4950

Neoprene 20x10

3 T8 L=2000c/c 1200

40

40

Plastic plug

50

480

265

Fig. 6. Middle beam. Section along hollow cores. T8: Hot rolled, weldable rebar A500HW, = 8 mm, in longitudinal joints between adjacent slabs, see 9.1.

Page 235: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

235

2.5 Slabs

1200

35

185

40

40223 223

265

223223152 152

Fig. 7. Nominal geometry of slab units.

- Extruded by Partek Betoniteollisuus Oy, Hyrylä factory 8.11.1993 and 11.11.1993 - 10 lower strands J12,5 initial prestress 950 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

115942,1

1193

180,

6 w,ib

36,1 w,ib = 216,537,9

Fig. 8. Floor test. Mean of most relevant measured geometrical characteristics of slabs 1–8.

Max measured bond slips: 2,5 , 2,2 and 1,9 mm in slab 4; 2,3 mm in slabs 1 and 6, 1,9 and 1,8 mm in slab 7 Measured weight of slab units = 4,09 kN/m

1159

1193

w,ib

w,ib = 217,935,3

182,

6

37,4

40,4

Fig. 9. Reference tests. Mean of most relevant measured geometrical characteristics of slabs 9 and 10.

Max measured bond slips: 2,3, 1,7and 1,4 mm in slab 10; 1,7, 1,5 and 1,4 mm in slab 9 Measured weight of slab units = 4,11 kN/m

There were 10 slabs cast on the same bed. Three of them were cast on the 8th of November, seven on the 11th of November. Since the expected failure mode was failure of the outermost slabs, the slabs were arranged as shown in Fig. 10. In this way, one slab from the both casting days remained for the reference tests.

Page 236: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

236

4

5

8 4

3

2

1

6

7

11.11. 11.11.

11.11.11.11.

8.11.

8.11. 11.11.

11.11.

North

South Fig. 10.Floor test. Position of slabs cast on November 8 and 11.

2.6 Temporary supports

Temporary supports below beams (Yes/No) - No

2.7 Loading arrangements

There were two separate, manually controlled hydraulic circuits, one for actuators P1 and the other for actuators P2, see Fig. 14. Attempts were made to keep P1 ≈ P2 to generate two uniform line loads on the floor. The primary spreader beams on the top of the floor were slightly shorter than 0,6 m. There was gypsum mortar between the primary spreader beams and the top surface of the floor. The friction between the secondary and primary spreader beams was eliminated by teflon plates (beams spreading loads P2) and by a roller bearing (beams spreading load P1).

Page 237: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

237

6000

95 5000

P P P P P P2 2

P P

P P

P P

PP

905

290

1234

5678

95

1000

5000

2 2 2 2

1 1

11

2 2 1 1 2 2

Nor

th

Sou

th

Det A

905

Fig. 11. Plan. P1 and P2 refer to vertical actuator forces. For det A, see Fig. 12.

Gypsum

Teflon plates

P Steel platesFDet A

2

F

F

F

Fig. 12. Detail A, see the figure above.

3 Measurements

3.1 Support reactions

Page 238: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

238

1

5

3 loadcells

Sou

th

Fig. 13. Load cells below the South end of the middle beam.

3.2 Vertical displacement

4

5

8 4

3

2

1

19

18

29

25

6

7

I II

III

IV V

3000 30003000

5000

106

7

8

9

11

12

13

14

5 15

16

17

2021

22

23

24

26

27

28

3000

6000 6000North

South

Fig. 14. Location of transducers 5 … 29 for measuring vertical deflection.

3.3 Average strain

5

6

7

8

47 46(62)(63)

48(65) (64)49

50 50

1

2

3

4

(61)

54(60)

53(59)

52(58)

(57)

50(56)

5155

North

South

L

TransducerSteel bar

Fig. 15. Apparatus for measuring average strain. L =1120mm and 1060 mm for the bottom and top side transducers, respectively.

Fig. 16. Position of device (transducers 50–61) measuring average strain parallel to the beams. Transducers 46–49 and 62–65 measured the sliding of the outermost slabs along the beam. Numbers in parentheses refer to the bottom, others to the top side.

Page 239: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

239

3.4 Horizontal displacements

5

6

7

8

1

2

3

4

North

South

41

43

45

40

44

42

Fig. 17. Transducers 40–45 measuring crack width on the top of the floor.

3.5 Strain

-

4 Special arrangements

-

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 14.12.1993

All measuring devices were zero-balanced when the actuator forces Pi were equal to zero but the weight of the loading equipment was on.

The loading history is shown in Fig. 18. Note, that the number of load step, not the time, is given on the horizontal axis. The load test took 3,5 h but in the beginning there was a break of half an hour due to a system error in the data logger.

In the following, the cyclic stage (steps 1–16) is called Stage I, the remaining part (steps 16–48) Stage II.

0

20

40

60

80

100

120

140

160

180

0 10 20 30 40 50

Load step

Pi [

kN]

P1

P2

Fig. 18. Development of actuator loads Pi.

Page 240: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

240

The weight of loading equipment per actuator was 1,2 kN and 5,6 kN for actuators P1 and P2, respectively. Consequently, the imposed load per slab was F1 = P1 + 1,2 kN for slabs 2, 3, 6 and 7 F2 = P2 + 5,6 kN for slabs 1, 4, 5 and 8

5.2 After failure

-

6 Observations during loading

Stage I The cast-in-situ concrete cracked vertically along ends of slabs 5, 7

and 8 at P1 = P2 = 55 kN.

Stage II At P1 = P2 = 70 kN he cast-in-situ concrete cracked vertically along ends of slabs 1 and 4. At P1 = P2 = 80kN these cracks had grown together. At P1 = P2 = 90 kN similar cracks on the opposite side of the middle beam had also grown together. At P1 = P2 = 168 kN inclined shear cracks appeared in the outermost webs of slabs 1, 5 and 8 close to the ends of the middle beam. This was followed by a sudden drop of P2. P2 could still be increased to the previous value and beyond it. At P1 = P2 = 168 kN an inclined shear crack appeared in the outermost web of slab 4 close to the North end of the middle beam. At P1 = 167,5 kN and P2 = 171,2 kN slabs 5–8 failed in shear as shown in Fig. 19.

After failure When the slabs were removed, it came out that the joint concrete had completely filled the space between the slab and the middle beam, the space under the slab end and the core fillings included.

Page 241: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

241

7 Cracks in concrete

7.1 Cracks at service load

Not documented.

7.2 Cracks after failure

8

7

6

5 1

2

3

4

8

7

6

5 1

2

3

4

15 84

1000100010001000

Fig. 19. Cracks after failure on the top, at the bottom and in the longitudinal edges of the floor.

8 Observed shear resistance

The maximum measured support reaction is regarded as the indicator of failure. The failure took place at P1 = 167,5 kN, P2 = 171,2 kN or F1 = 168,7 kN, F2 = 176,8 kN.

Fig. 20 shows the relationship between the measured support reaction below the South end of the middle beam and the sum of actuator loads on half floor.

The ratio of the reaction to the load is shown in Fig. 21 and in a larger scale in Fig. 22. Based on Fig. 22 it is justified to assume that at failure the support reaction due to the line load is equal to 0,874 times the line load. Assuming simply supported slabs gives the theoretical ratio of 0,85.

Page 242: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

242

0

100

200

300

400

500

600

0 100 200 300 400 500 600 700

Load step

Lo

ad

on

ha

lf flo

or

[kN

]

Fig. 20. Support reaction measured below South end of the middle beam vs. load on half floor = 2(P1 + P2 ).

0

0,2

0,4

0,6

0,8

1

1,2

1,4

0 100 200 300 400 500 600 700

Load on half floor [kN]

Su

pp

ort

re

act

ion

[kN

]

Fig. 21. Ratio of measured support reaction (below South end of the middle beam) to actuator loads on half floor.

Page 243: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

243

0,86

0,87

0,88

0,89

0,9

0,91

300 400 500 600 700

Load on half floor [kN]

Re

act

ion

/ L

oa

d o

n h

alf

floo

r

Fig. 22. A part of the previous figure in a large scale. The point corresponding to the highest support reaction has been indicated by an arrow. The observed shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P1, and P2, respectively. It is concluded that the maximum support reaction due to the imposed load on the failed slabs has been Vp = 0,874 x (actuator loads on half floor) / 4 = 0,874x(167,5 + 171,2) /2 = 148,0 kN. In the same way, the support reaction due to the weight of the loading equipment has been 0,874x(1,2+5,6)/2 = 2,97 kN. Vg,jc is calculated from the nominal geometry of the joints and measured density of the grout. When calculating Vg,sl, the measured weight of the slabs is used. The values of the shear force components are given in Table 1 below. Table 1. Components of shear resistance due to different loads.

Action Load Shear force

kN/slab

Weight of slab unit 4,09 kN/m 12,3

Weight of joint concrete 0,17 kN/m 0,5

Loading equipment (1,2+5,6)/2 kN/slab 3,0

Actuator loads (199,7+200,5) /2 kN /slab 148,0

The observed shear resistance Vobs = 163,8 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 136,5 kN/m.

Page 244: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

244

9 Material properties

9.1 Strength of steel:

Component ReH/Rp0,2 Rm Note MPa MPa Strands J12,5 1630 1860 Nominal (no yielding in test) Reinforcement Txy

500 Nominal value for reinforcing bars A500HW, no yielding in test

End beams ≈ 350 Nominal value for Fe 52, no yielding in test

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 23.12.1993 Upper flange of slabs 1, 2 and 5, two cores from each

Mean strength [MPa] 62,5 (+9 d)1) vertically drilled

St.deviation [MPa] 7,0 Tested as drilled2)

Density = 2445 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 23.12.1993 Upper flange of slab 9,

Mean strength [MPa] 70,8 (+9 d)1) vertically drilled

St.deviation [MPa] 4,3 Tested as drilled2)

Density = 2462 kg/m3 #

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 23.12.1993 Upper flange of slab 10,

Mean strength [MPa] 68,0 (+9 d)1) vertically drilled

St.deviation [MPa] 8,1 Tested as drilled2)

Density = 2453 kg/m3

9.4 Strength of grout in joints and tie beams

#

a

a

a

a mm

Date of test

Note

3 150 14.12.1993 Kept in laboratory in the same

Mean strength [MPa] 33,8 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] - Density = 2177 kg/m3

Page 245: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

245

9.5 Strength of concrete in upper part of middle beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 75 75 23.12.1993 Upper surface of beam,

Mean strength [MPa] 35,2 (+9 d)1) vertically drilled

St.deviation [MPa] 2,8 Tested as drilled2)

Density = 2217 kg/m3

9.6 Strength of concrete in lower part of middle beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 75 75 23.12.1993 Upper surface of beam,

Mean strength [MPa] 74,0 (+9 d)1) vertically drilled

St.deviation [MPa] 5,5 Tested as drilled2)

Density = 2450 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

10 Measured displacements

Note that the last two points on each curve represent the post failure situation.

10.1 Deflections

0

20

40

60

80

100

120

140

160

180

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

5

6

7

8

9

P1 [kN]

Fig. 23. Deflection on line I, Western end beam.

Page 246: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

246

0

20

40

60

80

100

120

140

160

180

0 2 4 6 8 10 12 14

Deflection [mm]

10

11

12

13

14

P1 [kN]

Fig. 24. Deflection on line II.

0

20

40

60

80

100

120

140

160

180

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

15

16

17

18

19

P1 [kN]

Fig. 25. Deflection on line III, middle beam.

Page 247: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

247

0

20

40

60

80

100

120

140

160

180

0 2 4 6 8 10 12 14

Deflection [mm]

20

21

22

23

24

P1 [kN]

Fig. 26. Deflection on line IV.

0

20

40

60

80

100

120

140

160

180

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

25

26

27

28

29

P1 [kN]

Fig. 27. Deflection on line V, Eastern end beam.

Page 248: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

248

0

20

40

60

80

100

120

140

160

180

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

7, End

17, Middle

27, End

P1 [kN]

Fig. 28. Net deflection of mid-point of beams (rigid body motion = settlement of beam supports has been eliminated).

The last measured net deflection of the middle beam at highest load level before failure was 7,7 mm. This is 3,8–4 mm higher than the net deflection of the end beams.

10.2 Crack width

0

20

40

60

80

100

120

140

160

180

0,0 0,4 0,8 1,2 1,6 2,0

Crack width [mm]

40

41

42

43

44

45

P1 [kN]

Fig. 29. Differential displacement ( crack width) measured by transducers 40–45.

Page 249: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

249

10.3 Average strain (actually differential displacement between slab edges)

0

20

40

60

80

100

120

140

160

180

-1,0 -0,8 -0,6 -0,4 -0,2 0,0

Differential displacement [mm]

50

51

52

53

54

55

P1 [kN]

Fig. 30. Differential displacement at top surface of floor measured by transducers 50–55.

0

20

40

60

80

100

120

140

160

180

0,0 0,2 0,4 0,6 0,8 1,0 1,2

Differential displacement [mm]

56

57

58

59

60

61

P1 [kN]

Fig. 31. Differential displacement at soffit measured by transducers 56–61.

Page 250: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

250

10.4 Shear displacement between slab edge and middle beam

In Figs 32 and 33 the differential displacements measured by transducers 46–49 and 62–65 are shown. A negative sign means that the slab edge is coming closer to the fixing point of the transducer.

0

20

40

60

80

100

120

140

160

180

-1,4 -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0

Differential displacement [mm]

46

47

62

63

P1 [kN] Top Bottom

Fig. 32. North end of middle beam. Differential displacement between edge of slab and middle beam.

0

20

40

60

80

100

120

140

160

180

-1,4 -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0

Differential displacement [mm]

48

49

64

65

P1 [kN] Top Bottom

Fig. 33. South end of middle beam. Differential displacement between edge of slab and middle beam.

10.5 Strain -

Page 251: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

251

11 Reference tests

Both ends of slabs 9 and 10 were loaded in shear as shown in Fig. 34. The tests were performed after the floor test (21.12.1993).

P

P1 2 3

456 7

8

1 (6) 2 (5) 3 (4)

8 (7)

Gypsum

30303030 L

0,5L 1000

Fig. 34. Layout of reference tests. Transducers 2 and 5 are in the mid-span. For L, see Table 2. The slip of the outermost strands was measured by transducers 7 and 8. The load-deflection relationship for the mid-point of the slabs is shown in Fig. 35 and the failure load in Table 2. The measured self-weight of the slabs = 4,11 kN/m has been used when calculating the shear resistance. Virtually no slip of the outermost strands was observed. For the failure mode, see also Appendix A.

0

50

100

150

200

250

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

P [k

N]

Test 9.1

Test 9.2

Test 10.1

Test 10.2

Fig. 35. Net mid-point deflection of slabs. Rigid body motion (= settlement of supports) has been eliminated.

Page 252: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

252

Table 2. Span L, ultimate load Pu, shear force due to self weight Vg, shear force due to imposed load VP, ultimate shear force Vu and failure mode in reference tests. The weight of the loading equipment = 1,4 kN is included in Pu.

Slab

L mm

Pu

kN

Vg

kN

VP

kN

Vu

kN

Failure mode

9,1 5936 240,4 12,19 201,1 213,3

250

860

9.2 5000 256,4 10,3 206,7 217,0 600

100

10.1 5935 219,4 12,2 183,5 195,7 400

10.2 5000 257,3 10,3 207,4 217,7 420

Mean 210,9

12 Comparison: floor test vs. reference tests

The observed shear resistance in the floor test was 163,8 kN per one slab unit or 136,5 kN/m. This is 65% of the mean observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only (deflection minus settlement of supports) was 7,7 mm or L/649 at the highest load level.

2. The shear resistance measured in the reference tests was of the same order as the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

3. Before failure, the net deflection of the end beams was 3,8–4 mm lower than that of the middle beam. This is a too small difference to cause considerable torsional stresses in the slabs.

4. The failure mode was a web shear failure of slabs on one side of the middle beam. Before failure there were diagonal cracks in all for slab edges next to the supports of the middle beam.

The failure behaviour of the slabs was similar to that in the other Finnish floor tests in which the slabs were supported close to the soffit of the middle beam.

Page 253: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A253

APPENDIX A: PHOTOGRAPHS

Page 254: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A254

Page 255: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A255

Page 256: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A256

Page 257: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A257

Page 258: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A258

Page 259: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A259

Page 260: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A260

Page 261: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.Rect-norm.265.1993

A261

Page 262: Matti Pajari Prestressed hollow core slabs supported on beams ...
Page 263: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

263

1 General information

1.1 Identification and aim

VTT.PC.InvT_Cont.265.1994 Last update 2.11.2010

PC265C (Internal identification)

Aim of the test To study the shear resistance of hollow core slabs supported on continuous beam.

1.2 Test type

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 3.3.1994

1.4 Test report

Author(s) Pajari, M.

Name Loading test for 265 mm hollow core floor supported on continuous beams

Ref. number RTE5-IR-4/1994

Date 29.4.1994

Availability Public, available on request from VTT Expert Services, P.O. Box 1001, FI-02044 VTT.

Financed by the Finnish Association of Building Industry RTT (supported by the Technology Development Centre of Finland); the Finnish Steel Work Association; the International prestressed Hollow core Association IPHA; KB Kristianstads Cementgjuteri, Sweden; Stombyggarna i Hudiksvall AB, Sweden and SBUF, Sweden

2 Test specimen and loading (see also Appendix A)

2.1 General plan

Page 264: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

264

P3

50

6000

5050

5000

1000

1000

480

1234

5678

1000 P31000

Support above beam

1000

10005000Support below beam

1200120012001200

SOUTHNORTH

Fig. 2. Plan.

2.2 End beams

Box girders made of steel. Span = 5,0 m

1000 1200 1001300

7200

HE 200 ASteel Fe 52

1000100 13001200

A

A

A A

20010

10

1706,5

7 stiffening plates, thickness = 10 mm

Fig. 3. End beam.

Page 265: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

265

Plywood

80 50

30 30Plastic plug

Tie beamL = 4750

2 T8

265

Fig. 4. Arrangements at end beam. T8 refers to a reinforcing bar, see 2.4.

2.3 Middle beam

The middle beam was a prestressed concrete beam provided with shear keys (indents) on both sides of the web. The grade of the concrete was K60. See Figs. 5, 6 and 8 for the dimensions of the cross-section.

40

Holes 80

40707070

1300 130012001200

5000 20002000

Fig. 5. Middle beam. Elevation.

Shear keys c/c 300

12575

265100

125 175

Fig. 6. Middle beam. Shear keys.

55 6 5070 x6x50

4 J12,5

14 J12,5

po

=1100 MPapo

=1100 MPa

70

4545

70 7070 50 50 50 50

7+7 J12,5

=1100 MPapo

4645

Fig. 7. Middle beam. Position of prestressing strands J12,5. For J12,5, see 9.1.

Page 266: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

266

2.4 Arrangements at middle beam

50

Plastic plug

265

502025 55 780

Neoprene 20x10100

48050

150

2 T8 L = 5150

2 T8 L = 5150

Shear keys 125x125 c/c 300

40

185

40

15

Fig. 8. Section along hollow cores.

3 holes c/c 1200

70

3 T8 L = 2000 c/c 1200

Fig. 9. Tie reinforcement in joints between adjacent slabs.

100

50

60

Grout

Concrete

Filling length 100 mm in outermost voids, 50 mm in other voids

a)

Steel profile

Steel bar

b)

Fig. 10. To prevent sliding of slab edge along the middle beam (this is not possible if the continuous beam carries hollow core slabs on both sides of the continuous support), a steel bar penetrating the web and a steel profile were installed. The empty space around the bar in the hole as well as the gap between the U-profile and the slab edge were grouted. a) Elevation. b) Top view (see also Fig. 16). See Also Appendix A, Figs 5 and 7. Txy: Hot rolled, weldable rebar A500HW, = xy mm, see 9.1.

Page 267: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

267

2.5 Slabs

1200

35

185

40

40223 223

265

223223152 152

Fig. 11. Nominal geometry of slab units (in scale).

- Extruded by Partek Betoniteollisuus Oy, Hyrylä factory 21.1.1994 - 10 lower strands J12,5 initial prestress 950 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

115543,7

1193

183,

9 w,ib

34,9 w,ib = 215,734,2

Fig. 12. Floor test. Mean of most relevant measured geometrical characteristics of slabs 1–8.

Max measured bond slips: 5,9 and 3,0 mm in slab 1; 3,3 and 2,5 mm in slab 6 and 2,2 mm in slab 7 Measured weight of slab units = 3,99 kN/m

1156

1194

w,ib

w,ib = 216,535,9

183,

5

34,1

43,5

Fig. 13. Reference tests. Mean of most relevant measured geometrical characteristics of slab 9.

Max measured bond slips: 6,5, 4,0, 2,3 and 2,2 mm in slab 10 (1,3 mm in slab 9) Measured weight of slab units = 4,01 kN/m

There were too large bond slips in strands at one end of slabs 1 and 6 (3,0–5,9 mm) and at both ends of slab 10. Slab 10 was rejected and the ends of slabs 1 and 6 with too high slip were placed on the end beams.

2.6 Temporary supports

Temporary supports below beams (Yes/No) - No

Page 268: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

268

2.7 Loading arrangements

There were three separate, manually controlled hydraulic circuits, one for actuators P1 the other for actuators P2, and the third for actuators P3, see Fig. 14. Attempts were made to keep P1 ≈ P2 to generate two uniform line loads on the floor. The aim of loads P3 was to make the middle beam behave as one with clamped ends (no rotation at support) as far as possible.

The primary spreader beams on the top of the floor were slightly shorter than 0,6 m. The friction between the secondary and primary spreader beams was eliminated by teflon plates (beams spreading loads P2) and by a roller bearing (beams spreading load P1). There was gypsum mortar between the primary spreader beams and the top surface of the floor.

P3

50

6000

5050

5000

P P P P P P2 2

1000

1000

P1

P2480

1234

5678

1 12 2 2 2

P1

P1P1

P2

P2

P21000 P

31000

Support above beam

1000

10005000Support below beam

1200120012001200

Det B

Det A

SOUTHNORTH

Primary Secondary

Primary

Secondary

Fig. 14. Plan. P1, P2 and P3 refer to vertical actuator forces. For det A and det B, see Figs. 15 and 16.

Page 269: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

269

Gypsum

Teflon plates

P Steel platesFDet A

2

F

F

F

Fig. 15. Detail A, see the figure above.

100 mm infill in outermost core

Shaft through beam

Fig. 16. Det B, see the figure above.

10001000

Load cell

5000

Fig. 17. Support conditions of end beams.

(P )3Load cell

Hydraulic actuator Hydraulic actuator

10001000 5000

(P )3

Fig. 18. Supports below and concentrated loads on middle beam.

3 Measurements

3.1 Support reactions

1

5

3 loadcells

Sou

th

Fig. 19. Load cells below the South end of the middle beam.

Page 270: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

270

3.2 Vertical displacement

4

5

8 4

3

2

1

19

18

29

25

6

7

I II

III

IV V

3000 30003000

5000

106

7

8

9

11

12

13

14

5 15

16

17

2021

22

23

24

26

27

28

3000

6000 6000

Fig. 20. Location of transducers 5 … 29 for measuring vertical deflection.

3.3 Average strain

(61)

54(60)

53(59)

52(58)

(57)

50(56)

5155

47 46

7070

(62)(63)

48(65) (64)49

5

6

7

8

1

2

3

4

South

North

L

TransducerSteel bar

Fig. 21. Apparatus for measuring average strain. L =1120mm and 1060 mm for the bottom and top side transducers, respectively.

Fig. 22. Position of device (transducers 50–61) measuring average strain parallel to the beams. Transducers 46–49 and 62–65 measured the sliding of the outermost slabs along the beam. Numbers in parentheses refer to the soffit of the floor, others to the top side.

Page 271: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

271

3.4 Horizontal. displacements

5

6

7

8

1

2

3

4

North

South

41 40

43

45 44

42

Fig. 23. Transducers 40–45 measuring crack width on the top of the floor.

3.5 Strain

-

4 Special arrangements

See 2.7 for the support conditions of the beams.

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 3.3.1994

All measuring devices were zero-balanced when the actuator forces Pi were equal to zero but the weight of the loading equipment was on.

The loading history is shown in Fig. 24. Note, that the number of load step, not the time, is given on the horizontal axis. The loading took 2 h 20 min.

In the following, the cyclic stage (steps 1–16) is called Stage I, the monotonous stage until P3 = 450 kN Stage II and the final stage with constant P3 until failure Stage III (steps 34–42).

0

50100

150

200250

300

350

400450

500

0 5 10 15 20 25 30 35 40 45

Load step

P [

kN]

P1

P2

P3

Fig. 24. Development of actuator loads Pi.

Page 272: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

272

The weight of loading equipment per actuator was 1,2 kN and 5,6 kN for actuators P1 and P2, respectively. Consequently, the imposed load per slab was

F1 = P1 + 1,2 kN for slabs 2, 3, 6 and 7 F2 = P2 + 5,6 kN for slabs 1, 4, 5 and 8

The weight of the loading equipment below actuator loads P3 was 0,5 kN and

F3 = P3 + 0,5 kN on the middle beam. The bending moment between the supports of the middle beam followed closely the elastic bending moment distribution until P1 = P2 = 160 kN, P3 = 450 kN. Thereafter P3 was kept constant. The bending moment in the span was roughly equal but opposite to that at supports, see Fig. 25.

-600

-400

-200

0

200

400

600

0 1 2 3 4 5

Distance from support [m]

M [kNm]

Fig. 25. Bending moment diagram of middle beam between supports at failure.

5.2 After failure

-

6 Observations during loading

Stage I The vertical joints between the slab ends and the middle beam cracked, and at P1 = P2 = 55 kN these cracks had grown through the whole length of the joint.

Stage II At P1 = P2 = 110 kN, the middle beam cracked in flexure at supports.

Stage III At P1 = P2 = 195 kN it was observed that the outermost hollow core slabs 1, 4, 5 and 8 were cracked in flexure below the line loads. At P1 = P2 = 200 kN slabs 1–4 suddenly and simultaneously failed in shear, see Figs 26 & 27 and Appendix A, Figs 7–16. It was impossible to say where the first shear crack appeared.

After failure When the slabs were removed, it came out that the joint concrete had completely filled the space between the slab and the middle beam, the space under the slab end included.

Page 273: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

273

7 Cracks in concrete

7.1 Cracks at service load

Not documented.

7.2 Cracks after failure

1

2

3

44

7

8

5

4

1

195195

195

110

195

110

6

0 0

200

200

200

5555

North

South

Fig. 26. Cracks after failure on the top and at the edges of the floor specimen. The numbers refer to the actuator loads P1.

180

20044

7

8

5

6 2

3

1

4

North

South Fig. 27. Cracks after failure in the soffit. The numbers refer to the actuator loads P1.

Page 274: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

274

8 Observed shear resistance

The maximum measured support reaction is regarded as the indicator of failure. The failure took place at P1 = 199,7 kN, P2 = 200,5 kN or F1 = 200,9 kN, F2 = 206,1 kN.

Fig. 28 shows the relationship between the measured support reaction below the South end of the middle beam and the sum of actuator loads on half floor. The effect of the actuator forces P3 have been subtracted from the measured support reaction, and it is not included in the load on the half floor, either.

The ratio of the reaction to the load is shown in Fig. 29 and in a larger scale in Fig. 30. Based on Fig. 30 it is justified to assume that at failure the support reaction due to the line load is 0,88 times the line load. Assuming simply supported slabs gives the theoretical ratio of 0,84.

0

100

200

300

400

500

600

700

800

900

0 100 200 300 400 500 600 700 800

Reaction force [kN]

Load on half floor [kN]

Fig. 28. Stage 1. Support reaction measured below South end of the middle beam vs. load on half floor = 2(P1 + P2 ).

0

0,2

0,4

0,6

0,8

1

1,2

0 100 200 300 400 500 600 700 800

Load on half floor [kN]

Reaction / Load on half floor

Fig. 29. Ratio of measured support reaction (below South end of the middle beam) to actuator loads on half floor.

Page 275: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

275

0,870

0,875

0,880

0,885

0,890

0,895

0,900

300 400 500 600 700 800

Load on half floor [kN]

Reaction / Load on half floor

Fig. 30. A part of the previous figure in a large scale. The observed shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P1, and P2, respectively. It is concluded that the maximum support reaction due to the imposed load on the failed slabs has been Vp = 0,88 x (actuator loads on half floor) / 4 = 0,88 x(199,7 + 200,5) /2 = 176,09 kN. In the same way, the support reaction due to the weight of the loading equipment has been 0,88x(1,2+5,6)/2 = 2,99 kN. Vg,jc is calculated from the nominal geometry of the joints and measured density of the grout. When calculating Vg,sl, the measured weight of the slabs is used. The values of the shear force components are given in Table 1 below. Table 1. Components of shear resistance due to different loads.

Action Load Shear force

kN/slab

Weight of slab unit 3,99 kN/m 11,8

Weight of joint concrete 0,17 kN/m 0,5

Loading equipment (1,2+5,6)/2 kN/slab 3,0

Actuator loads (199,7+200,5) /2 kN /slab 176,1

The observed shear resistance Vobs = 191,4 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 159,5 kN/m.

Page 276: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

276

9 Material properties

9.1 Strength of steel

Component ReH/Rp0,2 Rm Note MPa MPa Strands J12,5 1630 1860 Nominal (no yielding in test)

Reinforcement Txy 500 Nominal value for reinforcing bars, no yielding in test

End beams ≈ 350 Nominal value for Fe 52, no yielding in test

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 11.3.1994 Upper flange of slabs 1, 3 and 5, two cores from each

Mean strength [MPa] 73,4 (+8 d)1) vertically drilled

St.deviation [MPa] 3,1 Tested as drilled2)

Density = 2388 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 11.3.1994 Upper flange of slab 9,

Mean strength [MPa] 65,8 (+8 d)1) vertically drilled

St.deviation [MPa] 2,1 Tested as drilled2)

Density = 2382 kg/m3

9.4 Strength of grout in joints and core filling

#

a

a

a

a mm

Date of test

Note

3 150 3.3.1994 Kept in laboratory in the same

Mean strength [MPa] 25,2 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] - Density = 2177 kg/m3

9.5 Strength of concrete in middle beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 75 75 11.3.1994 Upper surface of beam,

Mean strength [MPa] 65,3 (+8 d)1) vertically drilled

St.deviation [MPa] 3,1 Tested as drilled2)

Density = 2425 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

Page 277: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

277

10 Measured displacements

10.1 Deflections

020406080

100120140160180200220

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

5

6

7

8

9

P1 [kN]

Fig. 31. Deflection on line I, Western end beam.

020406080

100120140160180200220

0 2 4 6 8 10 12 14 16 18

Deflection [mm]

10

11

12

13

14

P1 [kN]

Fig. 32. Deflection on line II.

Page 278: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

278

020406080

100120140160180200220

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

15

16

17

18

19

P1 [kN]

Fig. 33. Deflection on line III, middle beam.

020406080

100120140160180200220

0 2 4 6 8 10 12 14 16 18

Deflection [mm]

20

21

22

23

24

P1 [kN]

Fig. 34. Deflection on line IV.

020406080

100120140160180200220

0 1 2 3 4 5 6 7 8 9

Deflection [mm]

25

26

27

28

29

P1 [kN]

Fig. 35. Deflection on line V, Eastern end beam.

Page 279: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

279

020406080

100120140160180200220

0 1 2 3 4 5 6 7 8

Deflection [mm]

7, West end

27, East end

17, Middle

P1 [kN]

Fig. 36. Net deflection of mid-point of beams (rigid body motion = settlement of beam supports eliminated).

The last measured net deflection of the middle beam before failure was 5,2 mm. This was 1,7–1,8 mm lower than the net deflection of the end beams.

10.2 Crack width

020406080

100120140160180200220

0,0 0,5 1,0 1,5 2,0 2,5

Crack width [mm]

40

41

42

43

44

45

P1 [kN]

Fig. 37. Differential displacement ( crack width) measured by transducers 40–45.

Page 280: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

280

10.3 Average strain (actually differential displacement between slab edges)

020406080

100120140160180200220

-0,6 -0,5 -0,4 -0,3 -0,2 -0,1 0,0

Differential displacement [mm]

50

51

52

53

54

55

P1 [kN]

Fig. 38. Differential displacement at top surface of floor measured by transducers 50–55.

020406080

100120140160180200220

-0,1 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8

Differential displacement [mm]

56

57

58

59

61

55

P1 [kN]

Fig. 39. Differential displacement at soffit measured by transducers 56–61.

10.4 Shear displacement between slab edge and middle beam

In Figs 41 and 42 the differential displacements measured by transducers 46–49 and 62–65 are shown. A negative sign means that the slab edge is coming closer to the fixing point of the transducer. Fig. 40 illustrates how the negative curvature and cracking due to negative bending moment at support result in positive values of measured differential displacements on the top edge of the slab.

Page 281: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

281

P3

Fig. 40. Measuring differential displacement on the top of the floor.

020406080

100120140160180200220

-0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 1,2

Differential displacement [mm]

46

47

62

63

P1 [kN]

TopBottom

Fig. 41. North end of middle beam. Differential displacement between edge of slab and middle beam.

020406080

100120140160180200220

-0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4

Differential displacement [mm]

48

49

64

65

P1 [kN]

TopBottom

Fig. 42. South end of middle beam. Differential displacement between edge of slab and middle beam.

10.5 Strain -

Page 282: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

282

11 Reference tests

Both ends of slab 9 were loadedin shear as shown in Fig. 43. The tests were performed after the floor test (3.3.1994) but before the cores were drilled and loaded (11.4.1994). The slip of the outermost strands was measured by transducers 7 and 8. No slip was observed before failure.

P

P1 2 3

456 7

8

1 (6) 2 (5) 3 (4)

8 (7)

Gypsum

30303030 L

0,5L 1000

Fig. 43. Layout of reference tests. For L, see Table 2.

Table 2. Span L, ultimate load Pu, shear force due to self weight Vg, shear force due to imposed load Vu, ultimate shear force Vu and failure mode in reference tests. The weight of the loading equipment = 0,5 kN is included in Pu.

Slab

L mm

Pu

kN

Vg

kN

VP

kN

Vu

kN

Failure mode

9.1 5936 211,0 11,9 176,5 188,4

Shear tension failure

9.2 5000 237,1 9,6 191,1 200,7

Shear tension failure

Mean 194,6

Page 283: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

283

12 Comparison: floor test vs. reference tests

The observed shea191,4 kN per one slab unit or 159,5 kN/m. This is 98% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only

(deflection minus settlement of supports) was 5,2 mm or L/962

2. The shear resistance measured in the reference tests was of the same order as the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

3. Before failure, the net deflection of the end beams was 1,7–1,8 mm greater than that of the middle beam. This is a too small difference to cause considerable torsional stresses in the slabs.

4. The failure mode was an abrupt web shear failure of slabs on one side of the middle beam. No shear cracks were observed before the failure. This is typical of the shear tests carried out on non-flexible supports and different from the behaviour of the other 19 Finnish floor tests reported elsewhere in this working paper.

5. Within the accuracy of the measurements, the shear resistance observed in the floor test was equal to the mean of the resistances observed in the reference tests. This is also different from the behaviour of the other 19 Finnish floor tests.

Page 284: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A284

APPENDIX A: PHOTOGRAPHS

Page 285: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A285

Page 286: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A286

Page 287: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A287

Page 288: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A288

Page 289: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A289

Page 290: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A290

Page 291: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A291

Page 292: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT_Cont.265.1994

A292

Page 293: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

293

1 General information

1.1 Identification and aim

TUT.CR.MEK.265.1994 Last update 2.11.2010

MEK265 (Internal identification)

Aim of the test To study the interaction between the MEK beam and hollow core slabs.

1.2 Test type

Fig. 1. Illustration of test setup. MEK beam in the middle, steel beams (square tubes) at the ends.

1.3 Laboratory & date of test

TUT/FI 15.4.1994

1.4 Test report

Author(s) Iso-Mustajärvi, Pertti

Name MEK-liittopalkin ja ontelolaaston kuormituskoe (Load test on MEK composite beam and hollow core floor)

Ref. number

Tutkimusselostus N:o 253/94, Tampere University of Technology, Building Construction

Date 20.4.1994

Availability

Note

Confidential, owner is Normek Oy, Hiomotie 10, FI-00380 Helsinki, Finland

Figures in this paper have partly been modified (e.g. translation of text) by M. Pajari

2 Test specimen and loading

2.1 General plan

Fig. 2. Overview.

Page 294: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

294

Fig. 3. Plan.

Page 295: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

295

Fig. 4. Section C-C. Loading arrangements.

2.2 End beams

Fig. 5. End beam. Measured dimensions. Steel Fe 52D.

Page 296: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

296

Fig. 6. End beam, section A-A. Measured dimensions. 8 K 1200 refers to reinforcing bars T8 c/c 1200 where 8 is the thickness of the bar in mm. Simply supported, span = 5,02 m, fy 350 MPa (nominal fy)

2.3 Middle beam

Simply supported, span = 5,02 m The beam comprised a steel component, see Figs 7 and 8, which formed a composite beam with cast-in-situ concrete. The steel component was made of an I-beam, a horizontal plate (bottom flange) below the I-beam and two vertical zig-zag-shaped connector elements, welded to the I-beam and to the bottom plate. The cast-in-situ concrete, cast simultaneously with the grouting of the joints on the 31st of March 1994, filled the empty space between the slab ends laying on the bottom flange. Concrete: K30, max aggregate size 8 mm Structural steel: Fe52D

Fig. 7. Steel component of MEK beam. Cross-section.

Page 297: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

297

Fig. 8. Elevation. Note the zig-zag-shaped connector element.

2.4 Arrangements at middle beam

Fig. 9. Section B-B. 8 K 1200 refers to reinforcing bars T8 c/c 1200 where 8 is the thickness in mm.

2.5 Slabs

1200

35

185

40

40223 223

265

223223152 152

1160

Fig. 10. Nominal geometry of slab units.

- Extruded by Parma Oy, 9 slab elements were delivered to laboratory 11.03.1994 - 10 lower strands J12,5; initial prestress not given in the report but 1100 MPa was

a common value at that time

J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

2.6 Temporary supports

No temporary supports below beams.

Page 298: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

298

2.7 Loading arrangements

See Figs 2–4. The idea was to create two line loads using four actuators. Two actuator forces loaded one primary spreader beam which distributed the load to two secondary beams. Each secondary beam distributed the load to two tertiary spreader beams and each tertiary beam to two quaternary spreader beams. The quaternary beams were 550 mm long steel tubes with square cross-section 80 mm x 80 mm x 5 mm. The top surface below these beams was evened out with gypsum and a soft wood fibre plate was placed onto the gypsum and below the beams. In this way, a linear line load was created by 8 quaternary spreader beams. The bearings below the primary, secondary and tertiary spreader beams were hinges which also allowed longitudinal displacement at one end of each spreader beam. The fixed hinges were placed symmetrically.

3 Measurements

3.1 Support reactions

There were load cells below the South end of the middle beam.

Page 299: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

299

3.2 Vertical displacement

Fig. 11. Location of transducers 1–15 for measuring vertical deflection and that of transducers 16–28 for measuring differential horizontal displacement.

Page 300: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

300

Fig. 12. Section D-D.

3.3 Average strain

-

3.4 Horizontal. displacements

See Fig. 11 for the position of the horizontal transducers 16–28.

Page 301: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

301

3.5 Strain

The strains in the floor were measured by strain gauges placed as shown in Figs 13 and 14.

Fig. 13. Position of strain gauges 62 … 69 and 80 … 82.

Page 302: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

302

Fig. 14. Location of strain gauges 40 … 48.

4 Special arrangements - None …

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 15.4.1994. The support reaction, displacements and strains due to the installation of the slab elements, grouting and the weight of loading equipment are given in Sections 10.1 and 10.5. When the actuator forces P were equal to zero, all measuring devices were zero-balanced. Thereafter, each actuator force P was increased to 115 kN and reduced back to zero. This load cycle was repeated for four more times (5 cycles altogether) before increasing the actuator load monotonously to P = 324 kN which was the failure load. The cyclic and monotonous stages are called stage I and stage II, respectively.

Page 303: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

303

Fig. 15. Support reaction below South end of MEK beam vs. sum of actuator forces P (= 4P).

5.2 After failure

6 Observations during loading

Stage I At P = 91 kN, the first vertical cracks were observed in the tie beams at the ends of the floor. At P = 114 kN the joint concrete cracked along the slab ends next to the MEK beam 1,2 m from the edges of the floor.

Stage II At P = 172 kN the crack on the East side of MEK beam extended over the whole length of the beam. On the West side the same was true at P = 302 kN. At P = 302 kN cracks also appeared between the joint concrete and the edges of MEK beam. These cracks were at the end of the beam and 1,2 m long. At P = 313 kN an inclined crack was observed at the end of slabs 4 and 8 close to the MEK beam. At P = 324 kN a new inclined crack appeared in slab 8. This crack was on the East side of the previous inclined crack and resulted in shear failure of the floor. The development of the cracks and the failure mode are illustrated in Figs 16–22.

Page 304: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

304

7 Cracks in concrete

7.1 Cracks before failure

Fig. 16. Cracks on the top surface and at the edges before failure. The numbers refer to the value of actuator load P.

Page 305: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

305

Fig. 17. Cracks in tie beam.

Fig. 18. Inclined cracks in slab 8. The final failure crack on the right.

Page 306: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

306

7.2 Cracks after failure

Fig. 19. Failure of slab 8.

Fig. 20. Failure of slab 8.

Page 307: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

307

Fig. 21. Cracks after failure on the top and at the edges.

Page 308: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

308

Fig. 22. Cracks after failure in the soffit.

8 Observed shear resistance

The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + VP

where Vg,sl, Vg,jc, Veq and VP are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P, respectively. In this case the support reaction due to the self weight of the floor and loading equipment was measured directly. Therefore, the weight of the components was not measured. The shear force at failure can be calculated from values given in Table 1 on the next page.

Page 309: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

309

Table 1. Components of shear resistance due to different loads.

Action Support reaction

kN Shear force

kN

Weight of slab unit + Weight of joint concrete + Loading equipment (65,53)/4 16,4

Actuator loads 131,8 The observed shear resistance Vobs = 148,2 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 123,5 kN/m.

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

Bottom plate in MEK beam 354 350 358

513 501 518

Other steel in beams (Fe52D) 350 Nominal value

Slab strands J12,5 ≥ 1550 ≥ 1770 Obviously no yielding before failure

Reinforcement T8 500 Nominal value for reinforcing bars (no yielding in test)

9.2 Strength of slab concrete

#

Cores h

d

h mm

d mm

Date of test

Note

3 50 50 15.4.1994

Mean strength [MPa] 60,0 (+0 d)1)

St.deviation [MPa] 9.3 Strength of slab concrete, reference tests

Not measured, assumed to be the same as that in the floor test.

9.4 Strength of grout in joints of slab units and in MEK beam

#

a

a

a

a mm

Date of test

Note

4 150 15.4.1994 Kept in laboratory in the same

Mean strength [MPa] 33,3 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,96 1) Date of material test minus date of structural test (floor test or reference test)

10 Measured displacements

In the following figures, P stands for the actuator load in one actuator. Only the monotonous loading stage after the cyclic stage is shown.

Page 310: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

310

10.1 Deflections

Table 2. Support reaction below South end of MEK beam and deflection measured by transducers 13–15, both due to installation of hollow core slabs, grouting and loading equipment.

Reaction 13 14 15 40 41 42

kN [mm] [mm] [mm] [0,001] [0,001] [0,001]

65,53 3,05 4,04 3,26 -0,491 0,129 -0,122

Fig. 23. Mid-point deflection of end beams.

Fig. 24. Deflection of hollow core slabs, transducers 2–6.

Page 311: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

311

Fig. 25. Deflection of hollow core slabs, transducers 7–11.

Fig. 26. Deflection of MEK beam, transducers 13–15.

Page 312: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

312

Fig. 27. Differential vertical displacement between MEK beam and slab end measured by gauges 28 and 29.

10.2 Crack width

Fig. 28. Opening of joint ( crack width), transducers 16–19.

10.3 Average strain (actually differential displacement)

-

Page 313: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

313

10.4 Shear displacement

Fig. 29. Southern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

Fig. 30. Northern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

10.5 Strain Table 3. Strain in MEK beam due to installation of hollow core slabs, grouting and loading equipment measured by transducers 40–48.

40 41 42 43 44 45 46 47 48

[0,001] [0,001] [0,001] [0,001] [0,001] [0,001] [0,001] [0,001] [0,001]

-0,491 0,129 -0,122 -0,177 -0,133 0,102 0,204 0,152 0,165

Page 314: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

314

Fig. 31. Strain measured by gauges 40 (transverse to beam) and 42, 43 and 44 (parallel to beam).

Fig. 32. Strain measured by gauges 41 and 45–48.

Page 315: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

315

Fig. 33. Strain measured by gauges 69 and 80–82 in the soffit of hollow core slabs.

Fig. 34. Top surface of thee floor. Strain measured by gauges 62–68.

Page 316: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CR.MEK.265.1994

316

11 Reference tests

Fig. 35. Layout of reference test, slab 9. Lj = 5,93 m. Note the cast-in-situ concrete at the loaded end, cast on the 31st of March 1994, which filled 50 mm of the hollow cores. Table 4. Reference test. Span of slab, sum of actuator force Pa at failure and weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Pa+Peq kN

Vobs kN

vobs kN/m

Note

R1 ? 5930 230,7 223,2 186,0 Web shear failure

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 148,2 kN per one slab unit or 123,5 kN/m. This is 66% of the shear resistance observed in the reference test.

13 Discussion

1. The deflection of the middle beam due to the imposed actuator loads only

(deflection minus settlement of supports) was 16,7 mm or L/301.

2. The shear resistance measured in the reference tests was of the same order as the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005.

3. At failure load, the maximum difference in the mid-point deflection of the beams was 4,2 mm. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a minor effect on the failure of the slabs.

4. The failure mode was web shear failure of edge slab 8. The measured strains in the MEK beam show that the beam could not yield in longitudinal bending.

Page 317: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

317

1 General information

1.1 Identification and aim

VTT.RC.Rect-norm.265.1994 Last update 2.11.2010

RC265N (Internal identification)

Aim of the test To study the shear resistance of hollow core slabs supported on the top of reinforced concrete beam.

1.2 Test type

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 11.11.1994

1.4 Test report

Author(s) Pajari, M.

Name Loading test for 265 mm hollow core floor supported on reinforced concrete beams

Ref. number RTE-IR-7/1994

Date 20.12.1994

Availability Public, available on request from VTT Expert Services, P.O. Box 1001, FI-02044 VTT.

Financed by the Finnish Association of Building Industry RTT (supported by the Technology Development Centre of Finland); the Finnish Steel Work Association, the International Prestressed Hollow Core Association IPHA; KB Kristianstads Cementgjuteri, Sweden, Stombyggarna i Hudisksvall, Sweden and SBUF, Sweden

2 Test specimen and loading (see also photographs in Appendix A)

2.1 General plan

Page 318: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

318

290 1200

12290

7200

1200

6000 6000

1

2

3

4

5

6

7

8

9

10

11

12

North

South

A

A

Fig. 2. Plan.

2.2 End beams

The length of the beam was 7,6 m.

360

300

Concrete K30

Stirrup

2 T12 L = 7500

2 T25 L = 7500

3 T25 L = 7500

Fig. 3. Section of end beam. TXY refers to rebars with thickness xy mm, see 9.1. The stirrups were 6 and 8 mm thick rebars in the middle and at the ends of the beams, respectively.

Plywood

80 50

3030 Plastic plug

End beam

Tie beamL = 7150

2 T8

265

360

300 Fig. 4. Arrangements at end beam. T8 refers to a reinforcing bar, see 9.1

2.3 Middle beam

The middle beam was a reinforced concrete beam. The grade of the concrete was K60. See Figs 5 and 6. Txy refers to a reinforcing bar with diameter xy mm, see 9.1.

Page 319: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

319

200

12 T8 c/c 250

21 T10 c/c 100

3200 2000

21 * 2 T10 c/c 100

12 T10 c/c 250

200

7200200

200

21 * 2 T10 c/c 100

21 T10 c/c 100

2000

Stirrup A

Stirrup B

Stirrup C

A

A

Fig. 5. Stirrups. Txy refers to a reinforcing bar with diameter xy mm, see 9.1. Stirrup A is a hoop (rounded rectangular) surrounding all longitudinal rebars shown in Fig. 6.

380

480

230

350

150 150180

Stirrup B T10

Stirrup C

Concrete K60

4 T12

T10

6555

4 T25

6 T25

Stirrup B T10

Fig. 6. Middle beam. For the material of Txy and stirrups see 9.1.

2.4 Arrangements at middle beam

601520

380

Concrete K30

50

4 T8 L = 7400

Neoprene 20x10 5 T8 L=2000 c/c 1200between slabs

265

40

185

40

Plastic plug

50

480

290

Fig. 7. Middle beam. Section along hollow cores. T8 refers to rebar A500HW, d = 8 mm, see 9.1.

Page 320: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

320

2.5 Slabs

1200

35

185

40

40223 223

265

223223152 152

Fig. 8. Nominal geometry of slab units.

- Extruded by Partek Betoniteollisuus Oy, Hyrylä factory10.10.1994 - 10 lower strands J12,5 J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2, initial prestress = 950 MPa, see 9.1.

1153

1193

177,

3 w,ib

39,7 w,ib38,4 = 219,1

45,3

Fig. 9. Floor test. Mean of most relevant measured geometrical characteristics of slabs 1–12.

Max measured bond slips: 1,6 mm in slab 12; 1,4 and 1,3 mm in slab 5 Measured weight of slab units = 4,25 kN/m

= 221,8

1153

1193

w,ib

w,ib39,6

175,

0

40,0

46,9

Fig. 10. Reference tests. Mean of most relevant measured geometrical characteristics of slabs 13 and 14.

Max measured bond slips: 1,3 mm in slab 13 and 1,2 mm in slab 14, Measured weight of slab units = 4,33 kN/m

2.6 Temporary supports

Temporary supports below beams (Yes/No) - No

Page 321: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

321

2.7 Loading arrangements

The loads P, see Fig. 11, were generated by 6 identical hydraulic actuators, each connected to the same hydraulic pressure. The actuator loads were spreaded with the aid of 6 primary, 12 secondary and 24 tertiary spreader beams to two transverse line loads on the slabs as shown in Figs 11–13. The reaction forces of the actuators were carried by a temporary steel frame which was fixed to the floor of the hall by tension bars. Four holes were drilled through the test floor for these bars. The position of the tension bars is shown in Fig. 11. After the test it came out that the holes had no effect on the failure mechanism. The tertiary spreader beams on the top of the floor were slightly shorter than 0,6 m. The friction between the teriary and secondary beams was eliminated by roller bearings and that between the secondary and primary spreader beams by teflon plates. There was gypsum mortar between the tertiary spreader beams and the top surface of the floor.

2901200

12290

7200

1200

6000 6000

Hole through floorHydraulic actuator

1

2

3

4

5

6

7

8

9

10

11

12P

P

P

P

P

P

PTeflon sheets

P P P P P

A

A A

A

7200

North

South

Det A

Fig. 11. Loading arrangements.

Page 322: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

322

Gypsum

Teflon plates

P Steel platesFDet A

2

F

F

F

Fig. 12. Detail A, see the Fig. 11.

Fig. 13. Loading frame carrying the reaction of the actuators.

3 Measurements

3.1 Support reactions

1

7

3 loadcells

Sou

th

Fig. 14. Load cells below the South end of the middle beam.

Page 323: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

323

3.2 Vertical displacement

3000

9

8

7

6

5

17

18

16

15

14

13

12

24

25

23

22

21

20

19

31

32

30

29

28

27

26

38

39

37

36

35

34

33

10

11

3000 30003000

7

8

9

10

11

12

1

2

3

4

5

6

South

NorthI II III IV V

Fig. 15. Location of transducers 5 … 39 for measuring vertical deflection.

3.3 Average strain

1

2

3

4

5

6

7

8

9

10

11

12

64 69 66(65) (67)

80 104 92(81) (93)(105)

78 102 90(79) (91)(103)

76 100 88(77) (89)(101)

74 98 86(75) (87)(99)

72 96 84(73) (85)(97)

70 94 82(71) (83)(95)

A A

150

B B

B

B

6068

62(61) (63)

SouthAA

North

Fig. 16. Position of transducers measuring average strain parallel to the beam (70–105), displacement of the slab edges relative to the beam in beam's direction (60–67) and sliding of the upper part of the beam relative to the lower, precast part of the beam (68–69). Numbers in parentheses refer to the bottom, others to the top side.

Page 324: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

324

L

TransducerSteel bar

Fig. 17. Apparatus for measuring average strain. L = 1120mm and 1060 mm for the bottom and top side transducers, respectively.

3.4 Horizontal. displacements

42

41 46

47

4843

4944

5045

1

2

3

4

5

6

7

8

9

10

11

12

North

South Fig. 18. Transducers 41–50 measuring crack width on the top of the floor.

3.5 Strain

-

4 Special arrangements -

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 11.10.1994. Before the onset of the loads, the middle beam and the end beams had cracked due to the dead weight. The mid-point deflection of the middle beam was 32 mm and that of the end beams of the same order. The maximum crack widths in the middle beam and end beams were 0,20 and 0,15 mm, respectively. All measuring devices were zero-balanced when the actuator forces P were equal to zero but the weight of the loading equipment was on.

Page 325: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

325

The loading history is shown in Fig. 19. Note, that the number of load step, not the time, is given on the horizontal axis. The load test took 2 h 35 min. In the following, the cyclic stage (steps 1–16) is called Stage I, the remaining part (steps 16–52) Stage II.

0

50

100

150

200

250

0 10 20 30 40 50 60

Load step

P [

kN]

Fig. 19. Development of actuator loads Pi. The weight of loading equipment per one slab was 3,1 kN. Consequently, the imposed load per slab was

F = 0,5P + 3,1 kN.

5.2 After failure

-

6 Observations during loading

Stage I The cast-in-situ concrete in the upper part of the middle beam cracked vertically along the slab ends. At P = 60 kN the tie beams above the end beams started to crack. The maximum crack width in the middle beam was 0,25 mm.

Stage II At P = 220 kN the first shear cracks were observed at the ends of slabs 1 and 7, at P = 225 kN in slab unit 12 and at P = 233 kN also in slab unit 6. At P = 238,2 kN slab 7 failed.

After failure

When removing the loading equipment, slab 8 was knocked with a hammer. The sound revealed that the slab end had cracked. This was confirmed when slab 7 had been removed. A diagonal shear crack was observed at the end of slab 8 close to the middle beam. When the slabs were removed, it came out that the joint concrete had completely filled the space between the slabs and the middle beam, the space under the slab end and the core fillings included. The concrete infill in the cores of slab units cracked along the slab ends on one side of the middle beam while on the other side it remained virtually uncracked, see Figs. 20 and 21 in App. A.

Page 326: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

326

Three days after removal of the loads but when the loading equipment was still on, the deflection of the middle beam was 35 mm, i.e. only 3 mm more than the deflection before the test. Such a recovery is not possible after considerable yielding of the reinforcement in the concrete. This suggests that the softening behaviour observed in the load – deflection curve (see Fig. 29) is mainly attributable to effects other than the plastification of the reinforcement.

7 Cracks in concrete

7.1 Cracks at service load

See Fig. 20.

7.2 Cracks after failure

7

8

9

10

11

12

1

2

3

4

5

6

80 kN120 kN

60 kN

120 kN

80 kN

120 kN

220 kN

225 kN 220 kN

220 kN

233 kN225 kN

110 kN

60 kN

100 kN

130 kN

80 kN

120 kN

150 kN

Fig. 20. Cracks after failure on the top and in the longitudinal edges of the floor. The force values refer to the load P at which the crack was observed.

8 Observed shear resistance

The maximum measured support reaction is regarded as the indicator of failure. The failure took place at P = 238,2 kN.

Fig. 21 shows the relationship between the measured support reaction below the South end of the middle beam and the sum of actuator loads on half floor.

The ratio of the reaction to the load is shown in Fig. 22 and in a larger scale in Fig. 23. Based on Fig. 23 it is justified to assume that at failure the support reaction due to the line load is equal to 0,765 times the line load. Assuming simply supported slabs gives the theoretical ratio of 0,800 ... 0,801.

Page 327: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

327

0

100

200

300

400

500

600

0 100 200 300 400 500 600 700 800

Load on half floor [kN]

Sup

port

rea

ctio

n [k

N]

Fig. 21. Support reaction measured below South end of the middle beam vs. load on half floor (= 3P).

0

0,2

0,4

0,6

0,8

1

0 100 200 300 400 500 600 700 800

Load on half floor [kN]

Sup

port

rea

ctio

n [k

N]

Fig. 22. Ratio of measured support reaction (below South end of the middle beam) to actuator loads on half floor. The points corresponding to load P 0 are not shown.

Page 328: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

328

0,740,750,760,770,780,790,8

0,810,820,830,84

300 400 500 600 700 800

Load on half floor [kN]

Sup

port

rea

ctio

n [k

N]

Fig. 23. A part of the previous figure in a large scale. The point corresponding to the highest support reaction has been indicated by an arrow. The observed shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P, respectively. It can be concluded that the maximum support reaction due to the imposed load on the failed slabs has been Vp = 0,765 x (actuator loads on half floor) / 6 = 0,765x3x238,2/6 = 91,11 kN. In the same way, the support reaction due to the weight of the loading equipment has been 0,765 x 3,1 = 2,37 kN. Vg,jc is calculated from the nominal geometry of the joints and measured density of the grout. When calculating Vg,sl, the measured weight of the slabs is used. The values of the shear force components are given in Table 1 below. Table 1. Components of shear resistance due to different loads.

Action Load Shear force kN/slab

Weight of slab unit 4,25 kN/m 12,75 Weight of joint concrete 0,14 kN/m 0,42 Loading equipment 3,1 kN/slab 2,37 Actuator loads 238,2 /2 kN /slab 91,11

The observed shear resistance Vobs = 106,7 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 88,9 kN/m.

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

Strands J12,5 1630 1860 Nominal (no yielding in test)

Reinforcement Txy 500 Type A500 HW. Nominal value for reinforcing bars, no yielding in test

Page 329: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

329

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 24.11.1994 Upper flange of slabs 1, 7 and 12, two cores from each,

Mean strength [MPa] 67,2 (+13 d)1) vertically drilled

St.deviation [MPa] 1,7 Tested as drilled2)

Density = 2378 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 18.11.1994 Upper flange of slab 13,

Mean strength [MPa] 67,8 (< 7 d)1) vertically drilled

St.deviation [MPa] 2,5 Tested as drilled2)

Density = 2365 kg/m3 #

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 18.11.1994 Upper flange of slab 14,

Mean strength [MPa] 67,8 (< 7 d)1) vertically drilled

St.deviation [MPa] 2,9 Tested as drilled2)

Density = 2388 kg/m3

9.4 Strength of grout in joints, tie beams and in the upper part of the middle beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 75 75 24.11.1994 Upper surface of middle

Mean strength [MPa] 25,3 (+13 d)1) beam, vertically drilled

St.deviation [MPa] 1,3 Tested as drilled2)

Density = 2177 kg/m3

9.5 Strength of concrete in lower part of middle beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 75 75 24.11.1994 Upper surface of beam,

Mean strength [MPa] 63,6 (+13 d)1) vertically drilled

St.deviation [MPa] 4,0 Tested as drilled2)

Density = 2412 kg/m3

1) Date of material test minus date of structural test (floor test or reference test) 2) After drilling, kept in a closed plastic bag until compression

Page 330: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

330

10 Measured displacements

10.1 Deflections

0

50

100

150

200

250

0 5 10 15 20 25 30 35

Deflection [mm]

P [k

N]

5

6

7

8

9

10

11

Fig. 24. Deflection on line I, Western end beam.

0

50

100

150

200

250

0 5 10 15 20 25 30 35

Deflection [mm]

P [k

N]

12

13

14

15

16

17

18

Fig. 25. Deflection on line II.

0

50

100

150

200

250

0 5 10 15 20 25 30 35

Deflection [mm]

P [k

N]

19

20

21

22

23

24

25

Fig. 26. Deflection on line III, middle beam.

0

50

100

150

200

250

0 5 10 15 20 25 30 35

Deflection [mm]

P [k

N]

26

27

28

29

30

31

32

Fig. 27. Deflection on line IV.

0

50

100

150

200

250

0 5 10 15 20 25 30 35

Deflection [mm]

P [k

N]

33

34

35

36

37

38

39

Fig. 28. Deflection on line V, Eastern end beam.

Page 331: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

331

0

50

100

150

200

250

0 5 10 15 20 25 30 35

Deflection [mm]

P [k

N]

8

22

36

Fig. 29. Net deflection of mid-point of beams (rigid body motion = settlement of beam supports has been eliminated).

The last measured net deflection of the middle beam at highest load level before failure was 30,3 mm. This is 3,8–7 mm higher than the net deflection of the end beams. It is possible that the twist of the outermost slabs has affected the shear resistance.

10.2 Crack width

0

50

100

150

200

250

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0

Displacement [mm]

P [k

N] 41

42

43

44

45

Fig. 30. Differential displacement ( crack width) measured by transducers 41–45.

0

50

100

150

200

250

0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0

Displacement [mm]

P [k

N] 46

47

48

49

50

Fig. 31. Differential displacement ( crack width) measured by transducers 46–50.

10.3 Average strain (actually differential displacement between slab edges)

0

50

100

150

200

250

-0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6

Displacement [mm]

P [k

N]

70

72

74

76

78

80

Fig. 32. Differential displacement at top surface of slabs 7–12 measured by transducers 70, 72,...,80.

0

50

100

150

200

250

-0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6

Displacement [mm]

P [k

N]

82

84

86

88

90

92

Fig. 33. Differential displacement at top surface of slabs 1–6 measured by transducers 82, 84,...,92

Page 332: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

332

0

50

100

150

200

250

-2,0 -1,5 -1,0 -0,5 0,0 0,5 1,0

Displacement [mm]

P [k

N]

94

96

98

100

102

104

Fig. 34. Differential displacement at top surface of middle beam measured by transducers 94, 96,...,104.

0

50

100

150

200

250

-0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 1,2

Displacement [mm]

P [k

N]

71

73

75

77

79

81

Fig. 35. Differential displacement at soffit of slabs 7–12 measured by transducers 71, 73,...,81.

0

50

100

150

200

250

-0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 1,2

Displacement [mm]

P [k

N]

83

85

87

89

91

93

Fig. 36. Differential displacement at soffit of slabs 1–6 measured by transducers 83, 85,...,93.

0

50

100

150

200

250

0,0 0,5 1,0 1,5 2,0 2,5 3,0

Displacement [mm]

P [k

N]

95

97

99

101

103

105

Fig. 37. Differential displacement at soffit of the middle beam measured by transducers 95, 97,...,105.

10.4 Shear displacement between slab edge and middle beam

In Figs 38 and 39 the differential displacements between the lower and upper part of the slab edges relative to the middle beam in beams’s direction are shown. A negative sign means that the slab edge is approaching the end of the beam.

0

50

100

150

200

250

-3,5 -3,0 -2,5 -2,0 -1,5 -1,0 -0,5 0,0 0,5

Displacement [mm]

P [k

N] 60

61

62

63

Top

Bottom

Fig. 38. South end of middle beam. Differential displacement measured by transducers 60–63.

0

50

100

150

200

250

-3,5 -3,0 -2,5 -2,0 -1,5 -1,0 -0,5 0,0 0,5

Displacement [mm]

P [k

N] 64

65

66

67

Top

Bottom

Fig. 39. North end of middle beam. Differential displacement measured by transducers 64–67.

Page 333: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

333

In Fig. 40 the longitudinal, differential displacements between the upper and lower part of the middle beam are shown. A negative sign means that the upper part is approaching the end of the lower part (moving outwards more than the lower part).

0

50

100

150

200

250

-0,4 -0,3 -0,2 -0,1 0,0

Displacement [mm]

P [k

N]

68

69

Fig. 40. South end of middle beam. Differential displacement between upper and lower part of the middle beam at South end (transducer 68) and at North end (transducer 69).

10.5 Strain -

11 Reference tests

Slabs 13 and 14 were loaded in shear as shown in Fig. 41. The tests were performed after the floor test (11.11.1994) but before 18.11.1994.

P

P1 2 3

456 7

8

1 (6) 2 (5) 3 (4)

8 (7)

Gypsum

30303030 5940

5940/2 1200

Fig. 41. Layout of reference tests. The slippage of the outermost strands was measured by transducers 7 and 8. The load-deflection relationship for the mid-point of the slabs is shown in Fig. 42. The change in the slope is attributable to flexural cracking below the load. Despite the cracking, the failure mode in both tests was tensile failure in the web. Virtually no slippage of the outermost strands occurred before failure.

Page 334: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

334

0

50

100

150

200

250

300

0 5 10 15 20 25

Deflection [mm]

P [k

N]

13

14

Fig. 42. Net mid-point deflection of slabs 13 and 14. Rigid body motion (= settlement of supports) has been eliminated. The failure modes and failure loads are given in Table 2. The measured self-weight of the slabs = 4,33 kN/m has been used when calculating the shear resistance. Table 2. Span L, ultimate load Pu, shear force due to self weight Vg, shear force due to imposed load VP, ultimate shear force Vu and failure mode in reference tests. The weight of the loading equipment = 1,0 kN is included in Pu.

Slab

L mm

Pu

kN

Vg

kN

VP

kN

Vu

kN

Failure mode

13 5940 264,9 12,86 212,7 225,6

14 5940 266,5 12,86 214,0 226,9

Mean 226,2

Page 335: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

335

12 Comparison: floor test vs. reference tests

The observed shear resistance in the floor test was 106,7 kN per one slab unit or 88,9 kN/m. This is 47% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only (deflection minus settlement of supports) was 30,3 mm or L/238 at the highest load level.

2. The failure mode was a web shear failure of slab at the edge of the tested floor next to the middle beam. Before failure there were diagonal cracks in all four slab edges next to the supports of the middle beam.

3. The shear resistance measured in the reference tests was of the same order as the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

4. Before failure, the net deflection of the end beams was 3,8–7 mm higher than the net deflection of the end beams. It is possible that the twist of the outermost slabs has affected the shear resistance. On the other hand, when the first diagonal cracks were observed at load P = 220 kN (92% of the failure load), the net deflection of the end beams was less than 1,0 mm smaller than that of the middle beam.

5. The failure behaviour of the slabs was similar to that in the other Finnish floor tests in which the slabs were supported close to the soffit of the middle beam.

Page 336: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A336

APPENDIX A: PHOTOGRAPHS

Page 337: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A337

Page 338: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A338

Page 339: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A339

Page 340: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A340

Page 341: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A341

Page 342: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A342

Page 343: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A343

Page 344: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A344

Page 345: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A345

Page 346: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.RC.Rect-norm.265.1994

A346

Page 347: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

347

1 General information

1.1 Identification and aim

VTT.CP.LBL.320.1998 Last update 2.11.2010

LBL320 (Internal identification)

Aim of the test To quantify the interaction between the LBL beam and hollow core slabs.

1.2 Test type

Fig. 1. Overview on test arrangements. LBL beam in the middle, steel beams (square tubes) at the ends.

1.3 Laboratory & date of test

VTT/FI 25.3.1998

1.4 Test report

Author(s) Pajari, M.

Name Load test on hollow core floor

Ref. number RTE30146/98

Date 3.8.1998

Availability Confidential, owner is

Lujabetoni Oy

Harjamäentie 1

FI-71800 Siilinjärvi

Finland

2 Test specimen and loading (see also Appendices A and B)

The tie beams at the ends of the slabs and the enlargements at the edges of the slab near the middle beam were cast and the joints grouted on the 16th of March 1998.

Page 348: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

348

2.1 General plan

123

5678

5000 (span of beam)B

B

C

C

D

D

4

1200

50

1

500

(fro

m s

lab

end)

In-situ concrete K30

E

E

South

North

West

East

5000 (span of beam)

1200 1200 1200

1

200

(fro

m s

lab

end)

4

32

44

4

4

120

0

5000 (span of beam)

7

200

7

200

Fig. 2. Plan. For sections B-B, C-C, D-D and E-E see Figs 3, 4, 5 and 6.

Page 349: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

349

2.2 End beams

See Fig. 3. Simply supported, span = 5,0 m, roller bearing below Northern end fy 355 MPa (nominal fy), did not yield in the test.

50

Plywood

Plastic plug

L=4750

200

200

RHS

12.5 100

2 8

Fe52

50

40 40

Steel plate

B B

Concrete K30

Fig. 3. Arrangements at end beam (section B-B in Fig. 2). 8 refers to a reinforcing bar T8 with diameter 8 mm.

2.3 Middle beam

The beam, see illustration in Fig. 4 and App. A for more details, comprised

- a prefabricated steel component with a bottom plate, two upper chords made of reinforcing bars and bent reinforcing bars welded both to the chords and to the bottom plate (lattice girders) as shown in App. A.

- a precast and prestressed concrete component, see Fig 5 and App. A, provided with shear keys as shown in Fig. 4.

Steel plate

Precast prestressedconcrete

Shear keys50x220x10 c/c 100

Fig. 4. Illustration of LBL beam. The prestressed part was cast by Lujabetoni Oy Concrete: K80, max aggregate size 16 mm, rapidly hardening cement

Page 350: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

350

Passive reinforcement and tendons in LBL beam:

Txy: Hot rolled, weldable rebar A500HW, = xy mm J12,9: Prestressing strand, 7 wires, =12,9 mm, Ap = 100 mm2,

prestress = 1350 MPa, low relaxation (nominal value 2,5% at = 0,7fpu) Structural steel: S355J0, fy 355 MPa (nominal value) unless otherwise specified Tie reinforcement across the beam: A500HW, see above.

2.4 Arrangements at middle beam

1000

112

Bars welded to inserted steel plate

2 12 A500HW L = 2520 one on the other

260

1000

150

300 2 12 A500HW

520

450

60

1000

symm.

C C

Fig. 5. Suspension and tie reinforcement in joints between adjacent hollow core units (section C-C in Fig. 2). 12 refers to a reinforcing barT12 with diameter 12 mm.

432

6808 2080

50

Plastic plug

4 L= 4900

40

240

40

44

320

In-situ concrete K30

D D

Fig. 6. Arrangements at middle beam (section D-D in Fig. 2). 10 refers to a reinforcing bar T10 with diameter 10 mm.

Page 351: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

351

1000

112

Bar welded to inserted steel plate

2 8 L = 1400, 400 mm bent intothe grout, parallel to the beam

260

1000

150

300 1 12 A500HW

520

450

1000

symm.

E E

1 12 A500HW L = 2520

Fig. 7. Suspension and tie reinforcement at the outermost edges of the hollow core floor (section E-E in Fig. 2). 8 and 12 refer to reinforcing bars T8 and T12 with diameters 8 and 12 mm.

2.5 Slabs

1162

38

320 63 52

187 224 230

10

25

1196

40 40 40 40 40 6540

44

106

R12370

70

222

36

3850

817

101010

25 25 25274 137

R123

52

Fig. 8. Nominal geometry of slab units.

- Extruded by Lujabetoni Oy, Hämeenlinna factory 14.1.1998 - 13 lower strands J12,5, initial prestress 1100 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

1163 (at mid-depth)

61,7 61,7 61,761,0 61,0

54,3

37,5 42,3

222,8

Fig. 9. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 2,5 and 2,1 mm in slab 8 2,4 mm in slab 6 2,2 and 2,1 mm in slabs 2 and 3 Measured weight of slab units = 5,13 kN/m

Page 352: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

352

2.6 Temporary supports

No

2.7 Loading arrangements

44

P P P P P P2

P P

P P

PP

1200

432

123

5678

44

1200

A A

A A

P Pa1

4

300 300 300

300

300

300300300

300 300 300 300

300 300 300 300

Load cells 1, 2 ja 3under support of beam

South

North

West

Middle beam

Det 1

a1 a1 a1

a2a2

a2a2

a1 a1 a1 a1a2 a2

Fig. 10. Plan. Pa1 and Pa2 refer to vertical actuator forces.

Gypsum

Teflon plates

P Steel platesFDet 1

a1F

550F

F

Fig. 11. Detail 1, see previous figure.

Page 353: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

353

3 Measurements

3.1 Support reactions

8

7

4

3

1 2 3

Fig. 12. Load cells below the Northern support of the middle beam.

3.2 Vertical displacement

216

123

5678

4

3600

1617181920

1112131415

2627282930

3132333435

Transducer for measuring vertical displacement

216

3600

2122232425

3637383940

4142434445

30 30 30 30 30

30 30 30 30 30

20 20 202020

40 40 40 40 4030 30 30 30 30

3600

3600

3600

II

III

IV

V

VI

VII Fig. 13. Location of transducers 11 … 45 for measuring vertical deflection along lines I … VII.

Page 354: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

354

3.3 Average strain

-

3.4 Horizontal displacements

5678

4650

Measures differential displacement between steel flange and concrete component of beam in beam's direction

(51)

(49)48

(47)1234

545

8

56

5710 55

Measures differential displacement of slab edge and beam in beam's direction,numbers in parentheses refer to bottom fibre of slab, others to top fibre

7 6

940 40 40

Measures differential displacement between slab end and beam (crack width)

H52(53) H

Fig. 14. Transducers measuring crack width (5–10), shear displacement at the ends of the middle beam (46–53) and differential displacement between bottom plate and concrete component of the middle beam. Transducers 47, 49, 51 and 53 are below transducers 46, 48, 50 and 52, respectively.

J

49

48

H H

J

L-profile, glued to slab

L-profile, glued to slab

Fig. 15. Section H-H, see Fig. 15. Only transducers 48 and 49 shown.

48

49

46

47

J J

Fig. 16. Section J-J, see Fig. 16. Only transducers 46–49 shown.

J

55

H H

J

Fig. 17. Section H-H, see Fig. 15. Only transducers 55 is shown.

55 54

J J

Fig. 18. Section J-J, see Fig. 18. Only transducers 54 and 55 shown.

3.5 Strain

-

Page 355: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

355

4 Special arrangements

-

5 Loading strategy

5.1 Load-time relationship

Date of test was 25.3.1998 All measuring devices were zero-balanced when the actuator forces Pa1 and Pa2 were equal to zero but the weight of the loading equipment and the self-weight of the structure were acting. The weight of the loading equipment below loads Pa1 was equal to 5,6 kN and that below loads Pa2 equal to 1,2 kN. To create two uniform line loads to the floor, attempts were made to keep Pa2 equal to Pa1 + 4,4 kN. The loading history for Pa1 and Pa2 is shown in Fig. 20 and the measured support reaction in Fig. 21.

0

25

50

75

100

125

150

175

0 50 100 150 200 250

Time [min]

P [

kN

]

Pa1

Pa2

Fig. 19. Actuator forces Pa1 and Pa2 vs. time.

Page 356: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

356

0

50

100

150

200

250

300

350

400

450

500

550

600

0 25 50 75 100 125 150 175

Pm=(Pa1+Pa2)/2 [kN]

Rp

,ob

s [k

N]

Fig. 20. Support reaction RP,obs below Northern end of middle beam. Note the slight increase in RP,obs despite the reduction of Pm at the end of the curve.

0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

1

0 25 50 75 100 125 150 175

Pm=(Pa1+Pa2)/2 [kN]

Vp

,ob

s /

Pm

Fig. 21. Development of observed support reaction VP,obs per one slab as function of mean actuator force Pm.

5.2 After failure

-

Page 357: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

357

6 Observations during loading

Stage I (Cyclic)

The joint concrete between the middle beam and the slab units started to crack along the slab ends.

Stage II (Monotonous)

At Pa1 = 70 kN the cracks in the joint concrete between the middle beam and the slab units were continuous. At Pa1 = 80 kN the tie beams above the end beams started to crack. At Pa1 = 115 kN flexural cracks were observed in slab unit 1 (see Fig. 23). At Pa1 = 150 kN first shear cracks were observed in slab unit 5 and later in slab units 8, 1 and 4. At Pa1 = 168,3 kN and Pa2 = 174,0 kN a shear failure took place in slab units 5–8.

The cracking pattern after failure is shown in Fig. 23 and in App. B. Figs 6–15.

After failure The concrete infill in the cores of slab units remained virtually uncracked as can be seen in App. B, Figs 16–17. The cracking took typically place along the surface of the core filling and along the slab ends.

7 Cracks in concrete

7.1 Cracks at service load

7.2 Cracks after failure

1

2

37

8

5

4

680 70 80

145

125

160

115125

9040

135125 150

135

70

160

40145 40 145

125

Fig. 22. Cracking pattern after failure at top surface and at edges of floor. The force values refer to the actuator force Pa1

.

8 Observed shear resistance

The ratio (measured support reaction below one end of the middle beam)/ (theoretical support reaction due to actuator forces on half floor) is shown in Fig. 23. The theoretical reaction is calculated assuming simply supported slabs. This comparison shows that the support reaction due to the actuator forces can be calculated accurately enough assuming simply supported slabs. However, the failure of the slab ends first at the South end of the middle beam resulted in reduction of support reaction below that end and increase at the North end while the symmetrically positioned actuator forces were reduced. Therefore, the measured support reaction under the maximum actuator forces, not the maximum measured support reaction, is regarded as the indicator of failure. See also Chapter 10, Fig. 29.

Page 358: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

358

0,0

0,2

0,4

0,6

0,8

1,0

1,2

0 20 40 60 80 100 120

RP,obs / RP,th

Pa1 [kN] Fig. 23. Ratio of measured support reaction of the middle beam (Rp,obs) to theoretical support reaction (Rp,th) vs. actuator force Pa1. Only actuator loads Pa1 and Pa2 are taken into account in the support reaction. Assuming simply supported slabs and calculating the support reaction of the actuator loads from equilibrium of forces, gives support reaction which is 83,7% of the actuator loads. On the other hand, just before the failure, the measured support reaction under the North end of the middle beam was 81,68% of the loads on half floor. Using this relationship for the weight of loading equipment, and assuming that the weight of the slabs and jointing concrete was distributed to both ends of the slab units as if the slabs were simply supported beams, the shear resistance of one slab end (support reaction of slab end at failure) due to different load components can be calculated as shown below. Table. Components of shear resistance due to different loads.

Support reaction due to

weight of slab unit (Vg,sl) 82,9

42

3760377037503810

N 18,5 kN

weight of cast-in-situ concrete (Vg,isc) 4

75,0352,02 kN

0,8 kN

loading equipment (Veq)

2

2,16,58168,0

kN

2,8 kN

actuator loads (Vp)

2

0,1743,1688168,0

kN

139,8 kN

The shear resistance of one slab end due to imposed load

Vobs,imp = Vp + Veq = 139,8 kN + 2,78 kN = 142,6 kN

and the total shear resistance

Vobs = Vobs,imp + Vg,sl + Vg,isc = 142,6 kN + 18,5 kN + 0,8 kN = 161,9 kN

are obtained.

The observed shear resistance Vobs = 161,9 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 134,9 kN/m.

Page 359: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

359

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

Bottom plate 355 Nominal (S355J0)

Lattice girders 500 Nominal (A500HW) Slab strands J12,5 1570 1770 Nominal (no yielding in test) Beam strands J12,9 1630 1860 Nominal (no yielding in test)

Reinforcement Txy 500 Nominal value for reinforcing bars A500H

(no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 1.4.2009 Upper flange of slab1 (11–13) and 5 (51 –53),

Mean strength [MPa] 63,8 (+7 d)1) vertically drilled

St.deviation [MPa] 5,3 Tested as drill2460 kg/m3 9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 1.4.2009 Upper flange of slab 9 (91–93) and 10 (101 –103),

Mean strength [MPa] 61,8 (0 d)1) vertically drilled

St.deviation [MPa] 2,4 Tested as drilled2)

Density = 2480 kg/m3 9.4 Strength of grout in longitudinal joints of slab units

#

a

a

a

a mm

Date of test

Note

3 150 25.3.1998 Kept in laboratory in the same

Mean strength [MPa] 23,0 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] - Density = 2070 kg/m3

9.5 Strength of concrete in LBL beam

#

Cores h

d

h

mm

d

mm

Date of test

Note

3 75 75 1.4.2009 Upper flange, vertically

Mean strength [MPa] 84,8 (+7 d)1) drilled

St.deviation [MPa] - Tested as drilled2)

Density = 2480 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

Page 360: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

360

10 Measured displacements

In the following Figs 26–32, Vp stands for the shear force of one slab end due to imposed actuator loads, more accurately 1/4 of the measured support reaction below the North end of the middle beam. On the other hand, in Fig. 33 the mean actuator force = (Pa1+Pa2)/2 is used as load parameter. Comparison between Figs 29 and 33 shows that the maximum load carrying capacity was achieved before the maximum support reaction below the North end was measured. This suggests that there was load transfer from the South to the North while the shear cracks propagated in the slab units.

10.1 Deflections

In Fig. 29 (middle beam) the net deflection (= measured deflection – rigid body motion due to settlement of supports) is given, other figures show the measured deflection.

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[k

N

11

12

13

14

15

Fig. 24. Deflection on line I along end beam.

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[kN16

17

18

19

20

Fig. 25. Deflection on line II in the middle of slabs 1–4.

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[k

N

21

22

23

24

25

Fig. 26. Deflection on line III close to the line load, slabs 1–4.

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[kN

26

27

28

29

30

Fig. 27. Net deflection on line IV along the middle beam.

Page 361: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

361

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[kN

31

32

33

34

35

Fig. 28. Deflection on line V close to the line load, slabs 5–8.

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[k

N

36

37

38

39

40

Fig. 29. Deflection on line VI in the middle of slabs 5–8.

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[kN

41

42

43

44

45

Fig. 30. Deflection on line VII along end beam, slabs 5–8.

0

20

40

60

80

100

120

140

160

0 5 10 15 20 25 30

Deflection [mm]

Vp

[k

N]

28, middle

13

43

Fig. 31. Net deflection of midpoint of middle beam (28) and those of end beams (13, 43). (Settlement of supports eliminated.)

10.2 Crack width

0

20

40

60

80

100

120

140

160

0.0 0.5 1.0 1.5 2.0 2.5 3.0

Crack width [mm]

Vp

[k

N

5

6

7

8

9

10

Fig. 32. Differential displacement ( crack width) measured by transducers 5–10.

0

20

40

60

80

100

120

140

160

0,0 0,5 1,0 1,5 2,0

Crack width [mm]

Vp

[kN

]

5

6

7

8

9

10

Fig. 33. Same as previous figure but the cyclic loading phase is not shown.

Page 362: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

362

10.3 Average strain (actually differential displacement)

-

10.4 Shear displacement

0

20

40

60

80

100

120

140

160

-4 -3 -2 -1 0 1

Displacement [mm]

Vp

[k

N]

46 slab 1

47 slab 1

48 slab 5

49 slab 5

Fig. 34. Southern end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

0

20

40

60

80

100

120

140

160

-4 -3 -2 -1 0 1

Displacement [mm]

Vp

[k

N]

50 slab 4

51 slab 4

52 slab 8

53 slab 8

Fig. 35. Northern end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

Fig. 36. Shear displacement = differential displacement at upper edge – differential displacement at lower edge of slab.

0

20

40

60

80

100

120

140

160

-2,0 -1,5 -1,0 -0,5 0,0

Displacement [mm]

Vp

[k

N]

46-47 slab1

48-49 slab 5

50 - 51 slab 4

52 - 53 slab 8

Page 363: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

363

10.5 Relative displacement between bottom flange and concrete component of middle

beam

0

20

40

60

80

100

120

140

160

-0,06 -0,05 -0,04 -0,03 -0,02 -0,01 0,00 0,01

Displacement [mm]

Vp

[kN

]

54

56

57

Fig. 37. Differential displacement measured by transducers 54, 56 and 57.

0

20

40

60

80

100

120

140

160

-1,00 0,00 1,00

Displacement [mm]

Vp

[k

N]

55

Fig. 38. Differential displacement measured by transducer 55 (obviously incorrect).

11 Reference tests

P

P

1 2 3

456

7

8

1 (6) 2 (5) 3 (4)

8 (7)

Gypsum

40404040 7118 (Slab unit 9)

3560 1200

7120 (Slab unit 10) Fig. 39. Layout of reference test. a) Plan. b) Elevation. The displacements were measured by transducers 1–6, the bond slip of the outermost strands by transducers 7 and 8.

Page 364: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

364

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30 35 40 45 50

Deflection [mm]

P [

kN

]

Slab 9

Slab 10

Fig. 40. Actuator force – time relationship. R1 : Slab 9; R2:Slab 10.

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14

Deflection [mm]

Pa

[kN

] 123456

R1

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14

Deflection [mm]

Pa

[kN

] 123456

R2

Fig. 41. Displacements measured by transducers 1–6. Pa is the actuator force.

0

50

100

150

200

250

300

350

0 0,01 0,02 0,03

Slippage [mm]

Pa

[kN

]

78

R1

0

50

100

150

200

250

300

350

0 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08

Slippage [mm]

Pa

[kN

]

78

R2

Fig. 42. Slippage of outermost strands measured by transducers 7–8. Pa is the actuator force.

Page 365: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

365

Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure, weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

Pa kN

Peq kN

Vobs kN

vobs kN/m

Note

R1 1.4.1998 7118 18,5 332,0 0,8 297,1 250,6 Web shear failure

R2 1.4.1998 7120 18,4 328,0 0,8 293,6 244,7 Web shear failure

Mean 295,3 246,1

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 161,9 kN per one slab unit or 134,9 kN/m. This is 55% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. At maximum load, the net deflection of the middle beam due to the imposed

actuator loads (deflection minus settlement of supports) was 20,9 mm or L/240, i.e. rather small. It was 4,5–7,5 mm greater than that of the end beams. See Fig. 33 for the difference. Hence, the torsional stresses due to the different deflection of the middle beam and end beams may have had a minor effect on the failure of the slabs.

2. The shear resistance measured in the reference tests was typical of the similar slabs produced in Finland, see Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005.

3. The bond between the cast-in-situ concrete and the edges of the hollow cores was weak. This can be seen in the photographs in App. B in which the hardened hollow core fillings remained almost intact in most cases.

4. The sliding of the edge slabs along the middle beam was negligible before 85% of the failure load was achieved. At failure the differential displacement between the bottom flange of the beam and the soffit of the edge slabs was of the order of 0,2 … 0,5 mm. This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance.

5. The transverse shear deformation of the edge slabs was considerable which can be seen in Figs 47–49.

6. The failure mode was web shear failure of edge slabs. The LBL beam seemed to recover completely after the failure.

Page 366: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

A366

APPENDIX A: STEEL COMPONENT OF LBL BEAM

Fig. 1. Steel component of LBL beam. Elevation (lattice girders) and plan (bottom plate). See Fig. 2 for sections A, B and C.

Page 367: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

A367

Fig. 2. Sections A, B and C, see Fig. 1.

Page 368: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

A368

Fig. 3. Splicing of lattice girders.

Page 369: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

A369

Fig. 4. Bottom flange and position of lattice girders.

Page 370: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

A370

Fig. 5. Design of lattice girders.

Page 371: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

B371

APPENDIX B: PHOTOGRAPHS

Fig. 1. Overview.

Fig. 2. Loading equipment.

Fig. 3. Arrangements at end beams.

Fig. 4. Transducers at the end of middle beam.

Fig. 5. Failure pattern of slab unit 5.

Fig. 6. Detail of slab unit 5 after failure.

Page 372: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

B372

Fig. 7. Slab unit 5 seen from above after failure.

Fig. 8. Failure pattern of slab unit 8.

Fig. 9. Cracking pattern of slab unit 1 after failure of slab units 5–8.

Fig. 10. Detail of slab unit 1. Note the transverse crack in the soffit.

Fig. 11. Cracking pattern of slab unit 4 after failure of slab units 5–8.

Fig. 12. Failure pattern of slab units 5–8 seen from above.

Page 373: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

B373

Fig. 13. Failure pattern of slab units 5–8 seen from below.

Fig. 14. Failure pattern of slab units 5–7 seen from below.

Fig. 15. Edge of middle beam after removing slab units 1–4.

Fig. 16. Edge of middle beam after removing slab units 5–8.

Fig. 17. Detail of middle beam after removing slab units.

Fig. 18. Failure pattern of slab unit 9 in reference test.

Page 374: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.LBL.320.1998

B374

Fig. 19. Failure pattern of slab unit 9 in reference test.

Fig. 20. Failure pattern of slab unit 10 in reference test.

Fig. 21. Failure pattern of slab unit 10 in reference test.

Page 375: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

375

1 General information

1.1 Identification and aim

VTT.CR.Delta.400.1999 Last update 2.11.2010

DE400 (Internal identification)

Aim of the test To quantify the interaction between the Delta beam and 400 mm thick hollow core slabs.

1.2 Test type

Fig. 1. Overview of test arrangements. Delta beam in the middle, steel beams at the ends.

1.3 Laboratory & date of test

VTT/FI 2.12.1999

1.4 Test report

Author(s) Pajari, M.

Name Load test on hollow core floor

Ref. number RTE47/00

Date 29.3.2000

Availability Confidential, owner is Peikko Group Oy, P.O. Box 104, FI-15101 Lahti, Finland

2 Test specimen and loading (see also Appendices A)

Page 376: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

376

2.1 General plan

5000 (span of beam)

123

5678

5000 (span of beam)

A A

B

B

C

C

D

D

4

1200

50

170

0(f

rom

sla

b en

d)

In-situ concrete K30

E

E

540

1200

(fr

om s

lab

end

)12

00

1200 1200 120084

00 (

Len

gth

of s

lab

)

So

uth

No

rth

EastEast

West

Fig. 2. Plan.

Page 377: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

377

2.2 End beams

50

Plywood

Plastic plugL=4750

150

250RHS

10 75

St355

50

50 50

Steel plate

B B

Concrete K30

Steel rod, free to roll

2 T8

Fig. 3. Arrangements at end beam. T8 refers to a reinforcing bar A500HW with diameter 8 mm, see 2.3. Simply supported, span = 5,0 m fy 355 MPa (nominal fy), did not yield in the test.

2.3 Middle beam

The beam, see Fig. 4 and App. A, comprised

- a steel box girder with inclined, perforated webs - a concrete component, cast by VTT in laboratory on the 19th of November 1999,

which filled the empty space between the slab ends laying on the bottom flangee of the beam.

Concrete: K30 Reinforcement: Txy: Hot rolled, weldable rebar A500HW, diameter = xy mm Structural steel in Delta beam: Raex 420, fy 420 MPa (nominal fy) unless otherwise specified

225

5250

Holes 150

End plate 385x490x6

300

130(verticaldistance)

300

225

Ledges flame cut

30 Ledges flame cut

30

Fig. 4. Delta beam. The diameter of the holes was 150 mm.

Page 378: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

378

480

278

15

65

25

Rebars 2 32

385

500 100100

6

Fig. 5. Cross-section of Delta beam. The rebars were welded to the webs of the beam.

2.4 Arrangements at middle beam

- Simply supported, span = 5,0 m, roller bearing at one end

278

540Rebar 12 L = 3800 in each longitudinal joint between adjacent slab units

C C

Fig. 6. Section along joint between adjacent slab units, see Fig. 2.

Page 379: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

379

480

278

15

65

25

540

Rebars32

400

385

Rebars 212

100

D D

Concrete K30Plastic plug

Rebars 212

Fig. 7. Section along hollow cores, see Fig. 2.

278

540

Rebar 8 L = 3800, in cast-in-situ concrete outside longitudinal edges of outermost slab units

E E

Fig. 8. Section along outer edge of floor specimen, see Fig. 2.

Page 380: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

380

2.5 Slabs

Fig. 9. Nominal geometry of slab units (in scale).

- Extruded by Parma Betonila Oy, Hyrylä factory 29.10.1999 - 13 lower strands J12,5; initial prestress 1000 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

bw,i

46,1

308,4

38,6 42,1

1158 (at mid-depth)

bw,i = 297,6 Fig. 10. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 1,9 in slab 7; 1,8 in slab 8; 1,7 in slabs 2, 4, and 7 Measured weight of slab units = 5,39 kN/m

46,1

r=125

193

38,4

215

62

60,5

62 91 6242

1158

400

bw,i = 297,6

bw,i

Fig. 11. Cross-sectional geometry based on nominal and measured geometry.

2.6 Temporary supports

No temporary supports below beams.

Page 381: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

381

2.7 Loading arrangements

P 2P P P2

12

00(f

rom

sla

b en

d)

123

5678

a2

A A

A A

4

300 300 300

300

300

300300300

E

E

300 300 300 300

300 300 300 300

Load cells 2, 3 and 4 under support of beam

Det 1

a2a1 a1

Pa1

Pa1

Pa2 Pa2

Pa1Pa1Pa1Pa1

Pa2 Pa2

54

0 1

200

No

rth

So

uth

Fig. 12. Plan. Pa1 and Pa2 refer to vertical actuator forces.

Gypsum

Teflon plates

P Steel platesFDet 1

a1F

550F

F

Fig. 13. Detail 1, see previous figure.

Page 382: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

382

3 Measurements

3.1 Support reactions

1

5

3 load cells

No

rth

Fig. 14. Load cells below the Northern support of the middle beam.

3.2 Vertical displacement

270

123

5678

436

00

1617181920

1112131415

2627282930

3132333435

Transducers for measuring vertical displacement- Transducers 27, 28, 29 on the continued centrelines of the longitudinal joints between the slabs - Transverse measures given with respect to the centrelines of the joints between the slabs

270

4800

2122232425

3637383940

4142434445

30 30 30 30 30

30 30 30 30 30

20 20 202020

40 40 40 40 4030 30 30 30 30

3600

4800

540

I

II

III

IV

VII

VI

V

Fig. 15. Location of transducers 11 … 45 for measuring deflection along lines I … VII.

Page 383: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

383

3.3 Average strain

Not measured

3.4 Horizontal. displacements

5678

50(51)

1234

5

810

Measures differential displacement between slab edge and beam in beam's direction,numbers in parentheses refer to the soffit of the floor, others to the top

7 6

9

40 40 40

Measures differential displacement between slab end and beam (crack width)

H H52

(53)48(49)

46(47)

Middle beam

13020

13020

Fig. 16. Transducers measuring crack width (5–10) and shear displacement at the ends of the middle beam (46–53). Transducers 47, 49, 51 and 53 are below transducers 46, 48, 50 and 52, respectively.

J

49

48

H H

J

L-profile, glued to slab

(Only transducers 48 and 49 shown)

L-profile, glued to slab

Fig. 17. Section H-H, see Fig. 20.

48

49

46

J J

(Only transducers 46 - 49 shown)

20

2025

30 (from slab end)

Fig. 18. Section J-J, see Fig. 21.

Page 384: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

384

3.5 Strain and differential vertical displacement

The strain was measured using strain gauges at mid-span of the middle beam. Their position is shown in Fig. 19 The contact between the soffit of the slabs and the ledges of the middle beam was monitored by two transducers shown in Fig. 19.

54

A A

555657 6061

5859

5657 59 58

61 60

5455CL

CL

2

3

6

7

A A

CL

Plan

Fig. 19. Horizontal strain gauges 56–61 and transducers 54–55 for measuring differential vertical displacement.

Page 385: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

385

4 Special arrangements

- None

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 2.12.1999. The loading took 2 h 35 min. The actuator loads at different time steps are given in Fig. 20.

0

50

100

150

200

250

0 10 20 30 40 50

Time step

Act

ua

tor lo

ad [k

N]

Pa1

Pa2

Fig. 20. Actuator forces Pa1 and Pa2 at different time steps.

5.2 After failure

Page 386: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

386

6 Observations during loading

Before test Some longitudinal cracks along the strands were discovered in the soffit of the slabs before the test, see Fig. 22. They were below the webs (strands) of the hollow core units, parallel to the strands and obviously caused by the transfer of the prestressing force. Their width was less than 0,1 mm before the test, but it grew when the floor was loaded. They were obviously caused by the release of the prestressing force.

Stage I The joint concrete started to crack along the web of the Delta beam, see Fig. 23. In Figs 22 and 23 as well as in all figures in App. A presenting cracking, the numbers refer to the value of Pa1 in kN when the crack was first observed.

Stage II At Pa1 = 80 kN the tie beams at both ends of the specimen cracked vertically. There were also continuous, visible cracks between the joint concrete and the Delta beam, see Fig. 21. From Pa1 = 80 kN on, an increasing number of inclined cracks were observed in the corners of the outermost slab units close to the ends of the Delta beam. At Pa1 = 200 kN, diagonal shear cracks were observed in the corners of slab units 1 and 5, see App. 1, Figs 8 and 9. These cracks grew in width and length until at Pa1 = 238 kN, Pa2 = 233 kN slab units 5–8 failed in shear between the line load and the middle beam. The failure mode is illustrated in Fig. 23 and in App. A, Figs 8–24.

After failure The joint between the slab ends and Delta beam opened along the webs of the beam. The joint concrete as well as the interface between the joint concrete and the slab ends remained virtually uncracked, see Fig. 21 and App. A, Figs 23–28.

Fig. 21. Cracking mode between joint concrete and Delta beam.

The ledge of the Delta beam was in tight contact with the bottom surface of the slab units until failure. After the failure, the collapsing slab units deformed the ledges as shown in App. 1, Figs 14–16 and 25–28.

Page 387: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

387

7 Cracks in concrete

7.1 Cracks at service load

8

6

5

7

4

2

3

1

60 0

60

0

60

60

0

60

00

0

60

60600

60

6060

0

0

Fig. 22. Cracks in the soffit at service load (Pai = 60 kN). The initial cracks observed before loading are indicated with 0. The figures give the value of the actuator force at which the crack was observed.

7.2 Cracks after failure

8

200190

12010080 170200200

100225

210 235225

235

North

80210

8080

225225

6

5

7

4

2

3

1

60 80

East West

South

Fig. 23. Cracks after failure on the top and at the edges.

Page 388: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

388

8 Observed shear resistance

In Fig. 24 the reaction force under one end of the Delta beam, measured by load cells 2–4, is shown as a function of the load on half floor. The relationship is slightly nonlinear.

0

100

200

300

400

500

600

700

0 200 400 600 800 1000

Load on half floor [kN]

Fig. 24. Reaction force under support 1 of middle beam vs. load on half floor (=2Pa1 +2Pa2). Fig. 25 illustrates the ratio of measured support reaction of one slab end Vp due to the actuator loads (= one fourth of measured support reaction under one end of Delta beam) to the imposed loads on one slab unit (= (4xPa1+4xPa2)/8) as a function of Pa1. The dashed line in Fig. 25 indicates what the response for a simply supported slab would have been.

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

0 50 100 150 200 250

P1 [kN]

Simply supported behaviour

Fig. 25. Ratio of measured support reaction of a half floor to the load on the half floor. Only imposed load considered.

Page 389: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

389

Assuming simply supported slabs and calculating the support reaction of the actuator loads from equilibrium of forces gives a support reaction which is 86,1% of the actuator loads. On the other hand, just before the failure, the measured support reaction under end 2 of the Delta beam was 82,9% of the loads on half floor. Using this relationship also for the weight of loading equipment, and assuming that the weight of the slabs and cast-in-situ concrete was distributed to both ends of the slab units as if the slabs were simply supported beams, the shear resistance of one slab end (support reaction of slab end at failure) due to different load components can be calculated as shown in Table 2. Table 2. Components of shear resistance due to different loads.

Support reaction due to

weight of slab unit (Vg,sl) 9,82

42

4630459046304600

kN 22,65 kN

weight of cast-in-situ concrete (Vg,isc) 4

1,430,722 kN

1,4 kN

loading equipment (Veq)

2

1,25,60,8291

kN

2,82 kN

actuator loads (Vp)

4

162,7263,2354,6 kN

195,1 kN

The shear resistance of one slab end due to imposed load

Vu,imp = Vp + Veq = 195,1 kN + 2,8 kN = 197,9 kN and the total shear resistance

Vu = Vu,imp + Vg,sl + Vg,isc = 197,9 kN + 22,7 kN + 1,4 kN = 222,0 kN are obtained. The strong deviation of the support reaction from the simply supported behaviour of the slab units at Pa1 < 100 kN cannot be explained by the negative bending moment carried by the tie reinforcement penetrating the Delta beam. The bending moment corresponding to the yield stress 500 MPa of the tie reinforcement is of the order of 37 kNm per floor and 37/4 = 9,3 kNm per slab unit. This increases the support reaction of one slab unit at the Delta beam by 1,1 kN which is far too small to explain the behaviour. It is more likely that the extra support moment is due to the joint concrete. The tie reinforcement obviously helps in mobilizing vertical friction, dowel action and aggregate interlocking along the inclined webs of the Delta beam, particularly in the web holes. With increasing crack width along the Delta beam these effects fade out.

At Pa1 = 200 kN diagonal shear cracks at the ends of slab units 1 and 5 started to change the load-carrying mechanism of these slab units. The loads were more and more transferred to the neighbouring slab units and less directly to the beam. As a result, the support reactions of the Delta beam became different in such a way that the reaction force at the North end was smaller than that at the opposite end. This effect can be seen in Fig. 25 when Pa1 is greater than 200 kN.

Page 390: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

390

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

Delta beam 420 Nominal (Raex 420)

Slab strands J12,5 1630 1860 Nominal (no yielding in test)

Reinforcement Txy 500 Nominal value for reinforcing bars

(no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 10.12.1999 Upper flange of slabs 5 and 6,

Mean strength [MPa] 68,6 (+8 d)1) vertically drilled. Tested as drilled2)

St.deviation [MPa] 2,6 Density = 2448 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 10.12.1999 Upper flange of slab9, vertic-

Mean strength [MPa] 67,3 (+2 d)1) ally drilled. Tested as drilled2)

St.deviation [MPa] 1,7 Density = 2445 kg/m3

9.4 Strength of concrete in Delta beam and joints

#

a

a

a

a mm

Date of test

Note

6 150 2.12.1999 Kept in laboratory in the same

Mean strength [MPa] 28,8 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,8 Density = 2212 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

Page 391: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

391

10 Measured displacements

In the following figures, Vp stands for the average shear force of one slab end due to imposed actuator loads, calculated assuming simply supported slabs.

10.1 Deflections

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25

Deflection [mm]

11

12

13

14

15

Vp [kN]

Fig. 26. Deflection on line I along Western end beam.

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25 30 35

Deflection [mm]

16

17

18

19

20

Vp [kN]

Fig. 27. Deflection on line II in the middle of slabs 1–4.

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25 30

Deflection [mm]

21

22

23

24

25

Vp [kN]

Fig. 28. Deflection on line III close to the Delta beam, slabs 1–4.

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25 30

Deflection [mm]

26

27

28

29

30

Vp [kN]

Fig. 29. Deflection on line IV along the middle beam.

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25 30

Deflection [mm]

31

32

33

34

35

Vp [kN]

Fig. 30. Deflection on line V close to the Delta beam, slabs 5–8.

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25 30 35 40

Deflection [mm]

36

37

38

39

40

Vp [kN]

Fig. 31. Deflection on line VI in the middle of slabs 5–8.

Page 392: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

392

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25

Deflection [mm]

41

42

43

44

45

Vp [kN]

Fig. 32. Deflection on line VII along Eastern end beam, slabs 5–8.

020406080

100120140160180200

0 2 4 6 8 10 12 14 16 18 20 22

Displacement [mm]

Vp

[k

N]

13,West end

28, Delta

43,East end

Fig. 33. Net deflection of midpoint of middle beam (28) and those of end beams (13, 43). (Settlement of supports eliminated.)

10.2 Crack width

020406080

100120140160180200

0 1 2 3 4

Displacement [mm]

5

6

7

8

9

10

Vp [kN]

Fig. 34. Differential displacement ( crack width) measured by transducers 5–10.

020406080

100120140160180200

0 1 2 3 4

Displacement [mm]

5

6

7

8

9

10

Vp [kN]

Fig. 35. Same as previous figure but the cyclic loading phase is not shown.

10.3 Opening of gap between slab and ledge of Delta beam

0

50

100

150

200

-1,00 -0,75 -0,50 -0,25 0,00 0,25 0,50 0,75 1,00

Growth of gap [mm]

Vp

[k

N]

54, slabs 2 - 3

55, slabs 6 - 7

Fig. 36.

Page 393: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

393

10.4 Shear displacement

0

50

100

150

200

-0,5 0,0 0,5 1,0 1,5 2,0 2,5 3,0

Displacement [mm]

Vp

[k

N]

46, slab 1

47, slab 1

48, slab 5

49, slab 5

Fig. 37. Northern end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

0

50

100

150

200

-0,5 0,0 0,5 1,0 1,5 2,0 2,5 3,0

Displacement [mm]

Vp

[k

N]

50, slab 4

51, slab 4

52, slab 8

53, slab 8

Fig. 38. Southern end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

020406080

100120140160180200

-0,5 0,0 0,5 1,0 1,5 2,0 2,5 3,0

Displacement [mm]

Vp

[k

N]

46-47, slab 1

48-49, slab 5

50-51, slab 4

52-53, slab 8

Fig. 39. Shear displacement = differential displacement at upper edge – differential displacement at lower edge of slab.

10.5 Strain

0

50

100

150

200

-2000 -1500 -1000 -500 0

Strain [10-6]

Vp

[k

N]

56, ledge, slabs 2 - 357, ledge, slabs 6 - 758, top flange59, top flange

Fig. 40. Strain measured by gauges 56–59.

0

50

100

150

200

0 250 500 750 1000 1250 1500

Strain [10-6]

Vp

[k

N]

60

61

Fig. 41. Strain measured by gauges 60 and 61 parallel to Delta beam.

Page 394: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

394

11 Reference tests

P

P

1 2 3

456

7

8

1 (6) 2 (5) 3 (4)

8 (7)

Gypsum

50505050 8290 (Test R9/1)

4150 (Test R9/2)

1200

7150 (Test R9/2)

4800 (Test R9/1)

a)

b)

Fig. 42. Loading arrangements and position of transducers for measuring displacement (1–6) and slip of strand (7 and 8). a) Plan. b) Elevation.

0

100

200

300

400

500

600

0 5 10 15 20 25 30 35 40 45 50 55

Step

P [

kN]

R9/1

R9/2

Fig. 43. Actuator force – time relationship.

0

100

200

300

400

500

600

-5 0 5 10 15

Deflection [mm]

P [k

N] 1

2

3

4

5

6

R9/1

0

100

200

300

400

500

600

-5 0 5 10 15

Deflection [mm]

P [k

N] 1

2

3

4

5

6

R9/2

Fig. 44. Displacements measured by transducers 1–6. P is the actuator force.

Page 395: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

395

0

100

200

300

400

500

600

0,00 0,04 0,08 0,12 0,16

Slippage [mm]

P [k

N]

7

8

R9/1

0

100

200

300

400

500

600

0,0 0,0 0,1 0,1 0,2

Slippage [mm]

P [k

N]

7

8

R9/1

Fig. 45. Slippage of outermost strands measured by transducers 7–8. P is the actuator force. Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force P at failure, weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

P kN

Peq

kN Vobs kN

vobs kN/m

Note

R9/1 8.12.1999 8290 21,9 432,0 0,7 394,6 328,8 Web shear failure

R9/2 8.12.1999 7150 18,9 506,3 0,7 444,4 370,3 Web shear failure

Mean 419,5 349,6

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 222,0 kN per one slab unit or 185,0 kN/m. This is 53% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only

(deflection minus settlement of supports) was 24,0 mm or L/208.

2. The shear resistance measured in the reference tests was of the same order as the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

3. The maximum difference in the net mid-point deflection of the beams was 4,0 mm. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs.

4. The edge slabs slided 0,13 … 0,23 mm along the beam before failure. This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance.

5. The failure mode was web shear failure of edge slabs. The plastic deformation of the ledges of Delta beam was considerable on the failed side. Otherwise the Delta beam seemed to recover completely after the failure.

Page 396: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A396

APPENDIX A: PHOTOGRAPHS

Fig. 1. Delta-beam (middle beam in floor test).

Fig. 2. Detail of Delta-beam.

Page 397: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A397

Fig. 3. Overview of test arrangements.

Fig. 4. Loading arrangements.

Page 398: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A398

Fig. 5. Arrangements at support of middle beam.

Fig. 6. Measuring equipment on slab units 2, 3, 6 and 7.

Page 399: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A399

Fig. 7. Arrangements at support of end beam.

Fig. 8. Failure pattern of slab unit 5.

Page 400: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A400

Fig. 9. Failure pattern of slab unit 1.

Fig. 10. Failure pattern of slab unit 4.

Page 401: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A401

Fig. 11. Failure pattern of slab unit 8.

Fig. 12. Cracking pattern of tie beam between slab units 2 and 3 at failure of the floor.

Page 402: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A402

Fig. 13. Cracking pattern of tie beam at end of slab units 6 and 7 at failure of the floor.

Fig. 14. Deformation of ledge of Delta-beam under slab units 5–8 after failure of the floor.

Page 403: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A403

Fig. 15. Deformation of ledge of Delta-beam under slab units 5–8 after failure of the floor.

Fig. 16. Deformation of ledge of Delta-beam under slab unit 5 after failure of the floor.

Page 404: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A404

Fig. 17. Top surface of the floor after removal of loads.

Fig. 18. Top surface of slab unit 5 after failure.

Page 405: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A405

Fig. 19. Top surface of slab unit 6 after failure.

Fig. 20. Top surface of slab unit 7 after failure.

Page 406: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A406

Fig. 21. Top surface of slab unit 8 after failure.

Fig. 22. Top surface of slab unit 1 after failure.

Page 407: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A407

Fig. 23. Cracks along middle beam.

Fig. 24. Cracks along middle beam.

Page 408: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A408

Fig. 25. Joint concrete between slab unit 5–8 and midde beam after removal of slab units.

Fig. 26. Detail of the joint concrete after failure.

Page 409: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A409

Fig. 27. Web and deformed ledge of middle beam after removal of slab units and joint concrete. The tie bars penetrating the beam have been flame-cut after the test.

Fig. 28. Detail of middle beam after failure.

Page 410: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A410

Fig. 29. Reference test R9/1. Failure pattern.

Fig. 30. Reference test R9/1. Failure pattern.

Page 411: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.400.1999

A411

Fig. 31. Reference test R9/2. Failure pattern.

Fig. 32. Reference test R9/2. Failure pattern.

Page 412: Matti Pajari Prestressed hollow core slabs supported on beams ...
Page 413: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

413

1 General information

1.1 Identification and aim

VTT.CP.Super.320.2002 Last update 2.11.2010

SUP320 (Internal identification)

Aim of the test There were essential differences between Super beam and beams in previous floor test. A test was needed to quantify the interaction between the Super beam and hollow core slabs.

1.2 Test type

HE200BSuper beam

HE200B

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 17.1.2002

1.4 Test report

Author(s) Pajari, M.

Name Load test on hollow core floor

Ref. number RTE868/02

Date 3.4.2002

Availability Confidential, owner is Betset Oy,

P.O. Box 14, FI-43701 Kyyjärvi, Finland

2 Test specimen and loading (see also Appendices A and B)

Page 414: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

414

2.1 General plan

4800 (span of beam)

123

5678

4800 (span of beam)

A A

B

D

D

C

C

4

120040

170

0

(fro

m s

lab

end)

In-situ concrete K30

E

E

680

B

4800 (span of beam)

9600

(Le

ngt

h o

f sla

b )

1200 1200 1200

130

0

(fro

m s

lab

end)

West

No

rth

So

uth

East

9600

Fig. 2. Plan.

Page 415: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

415

2.2 End beams

200

200

HE 200 B

9 15

15

Fig. 3. End beam.

50

Plywood

Plastic plug

L=4700

HE 200 B

40

Steel plate

B B

Concrete K30

Steel rod,free to roll

2 6

40 40

Tie beam

Fig. 4. Arrangements at end beam. 6 refers to a reinforcing bar TW6, see 2.3.

Simply supported, span = 4,8 m, roller bearing below Southern end fy 355 MPa (nominal fy), did not yield in the test.

2.3 Middle beam

The beam, see Fig. 5 and App. A, comprised

- a prefabricated part with two L-shaped steel profiles, a folded and perforated steel plate welded to these profiles and a precast and prestressed concrete slab with ribbed reinforcement

- a cast-in-situ part of concrete which filled the empty space between the slab ends laying on the L-profiles.

- Lower, prestressed part cast by Betset Oy, 13.12.2001 - Upper part cast by VTT in laboratory, 4.1.2002 Concrete: K80 in the prefabricated part, K40 in the upper part Passive reinforcement and tendons in Super beam:

TWxy: Hot rolled, weldable rebar A500HW, = xy mm J12,9: Prestressing strand, 7 wires, =12,9 mm, Ap = 100 mm2, prestress = 1380 MPa Kz: Cold formed rebar B500K, = z mm

Structural steel: S355J2G3, fy 355 MPa (nominal fy) unless otherwise specified Tie reinforcement: Straight, nonprestressed prestressing strands across the middle beam and in the longitudinal joints of the slabs or outside the outer slabs, see Figs 7- 9. J12,5: 7 indented wires, =12,5 mm, Ap = 93 mm2 J9,3: 7 indented wires, =9,3 mm, Ap = 52 mm2

Page 416: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

416

Fig. 5. Middle beam.

2.4 Arrangements at middle beam

- Simply supported, span = 4,8 m, roller bearing at both ends

60010 3070

Plastic plug

40

240

40

230

Concrete K40

110

10 10100

Concrete K80

C C250

Fig. 6. Section along hollow cores, see Fig. 2.

D

2 J12,5 L = 4000

1 J12,5 L = 3000

Concrete K30Concrete K40Concrete K30

D

Fig. 7. Section along joint between adjacent slab units, see Fig. 2.

Page 417: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

417

1 J12,5 L = 4000

1 J9,3 L = 3000

E

Concrete K30Concrete K40Concrete K30

E

Fig. 8. Section along outer edge of floor specimen, see Fig. 2.

Fig. 9. Tie reinforcement across middle beam.

2.5 Slabs

Fig. 10. Nominal geometry of slab units (in scale).

- Extruded by Betset Oy, Kyyjärvi factory 21.11.2001 - 13 lower strands J12,5 initial prestress 1000 MPa - 2 upper strands J12,5 initial prestress 900 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

317

1162 (at mid-depth)

34,4 bw,i = 256

86

43

42,3

44,3 44,355,9 55,9 55,9

21,3

Fig. 11. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 2,5; 2,4; 2,3 and 2x2,1 mm, all in slab unit 6. Measured weight of slab units = 4,40 kN/m

Page 418: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

418

71

72,5

21,6

35 21141

223

67,3

43

320

r126

r126

229

72,5

35

72,5

105

35

86

35 43

r126

r126

1162

bw,i = 256

bw,i

Fig. 12. Geometry for calculation of cross-sectional characteristics.

2.6 Temporary supports

There were temporary supports at mid-span of all three beams during erection, see Fig. 13. They carried the weight of the slabs and cast-in-situ concrete as well as the weight of the loading equipment, and were removed during the first stage of the floor test.

Fig. 13. Temporary support below mid-point of middle beam.

Page 419: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

419

2.7 Loading arrangements

4800 (span of middle beam)

P P P 2P P P2

P P

P P

PP

1300(from slab end)

a1 a1

a2 a2

a2a2

123

5678

a2 a2a1 a1 a1 a1

A A

A A

P Pa1 a1

D

D

C

C

4

300

300

300

600

E

E

Load cells 2, 3 and 4 under support of beam

Det 1

340

340

300

300

300

600

300

300 300

300

300

300

Fig. 14. Plan. Pa1 and Pa2 refer to vertical actuator forces.

Gypsum

Teflon plates

P Steel platesFDet 1

a1F

550F

F

Fig. 15. Detail 1, see previous figure.

Page 420: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

420

3 Measurements

3.1 Support reactions

1

5

3 load cells

No

rth

Fig. 16. Load cells below the Northern support of the middle beam.

3.2 Vertical displacement

340

123

5678

4

4500

1617181920

2627282930

3132333435

Transducers for measuring vertical displacement- Transducers 27, 28, 29 on the continued centrelines of the longitudinal joints between the slabs - Transverse measures given with respect to the centrelines of the joints between the slabs

5100

2122232425

3637383940

30 30 30 30 30

30 30 30 30 30

20 20 202020

680

II

III

IV

VI

V

340

1112131415

40 40 40 40 4030 30 30 30 30I

5100

4500

41424345 VII44

No

rth

So

uth

Fig. 17. Location of transducers 11 … 45 for measuring vertical deflection along lines I … VII.

Page 421: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

421

3.3 Average strain

5678

55 (61)1234

L

L

2030

440

440

54 (60)

56 (62)57 (63)

59 (65) 58 (64)

L

L

20

2056

60

54

62

58

64

No

rth

So

uth

Fig. 18. Position of device (transducers 54–65) measuring average strain parallel to the beams. Numbers in parentheses refer to the soffit of the floor, others to the top.

L

TransducerSteel bar

Fig. 19. Apparatus for measuring average strain. L =1040 mm and 1150 mm for the top and soffit transducers (54–59 and 60–65), respectively.

3.4 Horizontal. displacements

5678

50(51)

1234

5

810

Measures differential displacement between slab edge and beam in beam's direction,numbers in parentheses refer to the soffit of the floor, others to the top

7 6

9

40 40 40

Measures differential displacement between slab end and beam (crack width)

H H52

(53)48(49)

46(47)

Middle beam

13020

13020

Fig. 20. Transducers measuring crack width (5–10) and shear displacement at the ends of the middle beam (46–53). Transducers 47, 49, 51 and 53 are below transducers 46, 48, 50 and 52, respectively.

Page 422: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

422

J48

H H

J

L-profile, glued to slab

(Only transducers 48 and 49 shown)

49

Fig. 21. Section H-H, see Fig. 20.

48

49

46

J J

(Only transducers 46 - 49 shown)

20

20

47

30 (from slab end)

Fig. 22. Section J-J, see Fig. 21.

3.5 Strain

3 50 50

20

5050

3020

2

67

110

600

CL

72

68

66

69

7173

70

110

L

L

LL

Longitudinalstrain gauges

5

67

2030 Transversestrain gauges

20

L

L

30

Fig. 23. Position of strain gauges 66–73 at mid-section of middle beam.

4 Special arrangements

5 Loading strategy

5.1 Load-time relationship

Date of test was 17.1.2001 Before removal of the temporary supports and when the actuator forces Pai were equal to zero but the weight of the loading equipment was on, all measuring devices were zero-balanced. Thereafter, the temporary supports were removed. Fig 24 shows the effect of this operation to the support reaction of the middle beam. The loading history is shown in Fig. 25.

Page 423: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

423

02468

101214161820

0 5 10 15 20 25 30Time [min]

R [k

N]

a)

0,0

20,0

40,0

60,0

80,0

100,0

120,0

0 100 200 300 400 500

Pa1 [kN]

R [kN]

b) Fig. 24. Development of support reaction R below Northern end of middle beam a) When removing the temporary supports. b) Later as function of Pa1.

-10

10

30

50

70

90

110

130

150

0 20 40 60 80 100 120 140 160 180Time [min]

Pa

[kN

]

Pa2Pa1

Stage IIIStage IIStage I

Fig. 25. Actuator forces Pa1 and Pa2 vs. time.

5.2 After failure

6 Observations during loading

Stage I Some longitudinal cracks along the strands were discovered in the soffit of the slabs, see Fig. 30. Their width was of the order of 0,08 … 0,10 mm. They were obviously caused by the release of the prestressing force.

Stage II The interface between the cast-in-situ concrete and slab ends cracked along slabs 1–4 at Pa1 = 30 kN and along slabs 5–8 at Pa1 = 50 kN. The tie beams at the ends of the floor specimen failed between slabs 2 and 3 at Pa1 = 30 kN and between slabs 6 and 7 at Pa1 = 50 kN. Pai = 50 kN corresponds to the expected service load when the shear resistance of the slabs was assumed to be critical in the design.

At the end of Stage II, some cracks in the soffit had increased in length and their maximum width was of the order of 0,10–0,12 mm , see Fig. 30.

Page 424: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

424

Stage III

At Pa1 = 115 kN an inclined crack was observed outside slab 1 at Northern support of middle beam and soon after that a similar crack appeared outside slab 5. At Pa1 = 120 kN, similar cracks appeared outside slabs 4 and 8, see Figs 8–11 in App. B. The next aimed load step Pa1 = 120 kN, Pa2 = 124,4 kN could not be achieved because new inclined cracks appeared below the previous ones in slabs 1 and 5 Consequently, slab 1, followed by slabs 4 and 5 failed in shear. The highest support reaction was obtained at load combination Pa1 = 112,6 kN, At Pa2 = 123,7 kN.

After failure

When demolishing the test specimen it was observed that all core fillings were not perfect. Due to the cracking mechanism, see Fig. 26, the core fillings could be measured, see Figs 27–29 and App. B, Figs 22–25.

Fig. 26. Cracking took typically place along the surface of the core filling.

Fig. 27. Super beam after removal of slab units.

Page 425: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

425

b

dcf

cf

Chamfer 30x30 250

72.5

72.5

105

a) b)

Fig. 28. a) Core filling seen in the beams’s direction. b) Nominal dimensions of a hollow core.

1a1b1c1d2a2b2c2d3a3b3c3d4a4b4c4d

5a5b5c5d6a6b6c6d7a7b7c7d8a8b8c8d

bcf

bcf

dcf

dcf

20 18 12 4 12 17 18 17 18 10 12 16 19 15 14

13 15 13 8 14 14 12

3 7 8 10 6 3 2 3 5 10 11 5 6 5 7

9 8 6 910 8 7

Wide crack Thin crack

Thin crackCracked or not?

South North

Fig. 29. Core fillings seen from above after removal of slabs. The core fillings are identified by the number of the slab and letters a–d. dcf and bcf, see Fig. 42, are given in centimetres.

7 Cracks in concrete

7.1 Cracks at service load

123

5678

4

000

00

50

0

0

0B

50

5050

5050

50

50

50

50

50

50

No

rth

So

uth

Fig. 30. Cracks in the soffit at service load (Pai = 50 kN). The initial cracks observed before loading are indicated with red colour. The figures give the value of the actuator force at which the crack was observed.

Page 426: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

426

7.2 Cracks after failure

123

5678

4

120115

115120

Fig. 31. Cracks after failure on the top and at the edges.

123

5678

4

No

rth

So

uth

Fig. 32. Cracks after failure in the soffit.

8 Observed shear resistance

The ratio (measured support reaction below one end of the middle beam)/ (theoretical support reaction due to actuator forces on half floor) is shown in Fig. 33. The theoretical reaction is calculated assuming simply supported slabs. This comparison shows that the support reaction due to the actuator forces can be calculated accurately enough assuming simply supported slabs. However, the failure of the slab ends at the North end of the middle beam resulted in reduction of support reaction below that end while the actuator force could still slightly be increased. The maximum support reaction is regarded as the indicator of failure.

Page 427: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

427

0,0

0,2

0,4

0,6

0,8

1,0

1,2

0 20 40 60 80 100 120

RP,obs / RP,th

Pa1 [kN]

Fig. 33. Ratio of measured support reaction of the middle beam (Rp,obs) to theoretical support reaction (Rp,th) vs. actuator force Pa1. Only actuator loads Pa1 and Pa2 are taken into account in the support reaction. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Va

where Vg,sl, Vg,jc, Veq and Va are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pai, respectively. All components of the shear force are calculated assuming that the slabs behave as simply supported beams. For Veq and Va this means that Veq = 0,8677xPeq and Va = 0,8677x(Pa1 + Pa2)/2. Vg,jc is calculated from the nominal geometry of the joints and density of the concrete, other components of the shear force are calculated from measured loads and weights. The values for the components of the shear force are given in Table below. Table. Components of shear resistance due to different loads.

Action Load Shear force

kN

Weight of slab unit 4,40 kN/m 20,97

Weight of joint concrete 0,212 kN/m 1,01

Loading equipment (1,2+5,6)/2 kN 2,95

Actuator loads (112,6+123,7)/2 kN 102,52

The observed shear resistance Vobs = 127,5 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 106,2 kN/m

Page 428: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

428

9 Material properties

9.1 Strength of steel

ReH/Rp

0,2 Rm

Component MPa MPa

Note

L-profiles 355 Nominal (S355J2G3) Folded plate 355 Nominal (S355J2G3) Tie strands J12,5 and J9,3 1630 1860 Nominal (no yielding in test) Slab strands J12,5 1630 1860 Nominal (no yielding in test) Beam strands J12,9 1630 1860 Nominal (no yielding in test)

Reinforcement Txy and Kz 500 Nominal value for reinforcing bars(no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 25.01.2002 Upper flange of slabs 5 and

Mean strength [MPa] 62,1 (+8 d)1) 6, vertically drilled, tested as

St.deviation [MPa] 4,6 drilled2), density =2328 kg/m3

9.3 Strength of slab concrete, reference tests

Not measured, assumed to be the same as that in the floor test

9.4 Strength of grout in longitudinal joints of slab units

#

a

a

a

a mm

Date of test

Note

6 150 17.1.2002 Kept in laboratory in the same

Mean strength [MPa] 21,4 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,90 density = 2152 kg/m3

9.5 Strength of concrete in the upper part of the beam and in the core filling

#

a

a

a

a mm

Date of test

Note

6 150 17.1.2002 Kept in laboratory in the same

Mean strength [MPa] 33,3 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,30 density = 2178 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

Page 429: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

429

10 Measured displacements

In the following figures, Va stands for the shear force of one slab end due to imposed actuator loads, calculated assuming simply supported slabs. Note that the last three points on each curve represent the post failure situation for which the real shear force has been lower than that shown in the figures. This note is based on the measured support reaction, see Fig. 25.b.

10.1 Deflections

0

20

40

60

80

100

120

0 5 10 15 20 25 30

Deflection [mm]

Va

[kN

]

1112131415

Fig. 34. Deflection on line I along western end beam.

0

20

40

60

80

100

120

0 5 10 15 20 25 30

Deflection [mm]

Va

[kN

]

1617181920

Fig. 35. Deflection on line II in the middle of slabs 1–4.

0

20

40

60

80

100

120

0 5 10 15 20 25 30

Deflection [mm]

Va

[kN

]

2122232425

Fig. 36. Deflection on line III close to the line load, slabs 1–4.

0

20

40

60

80

100

120

0 5 10 15 20 25 30

Deflection [mm]

Va

[kN

]

2627282930

Fig. 37. Deflection on line IV along the middle beam.

0

20

40

60

80

100

120

0 5 10 15 20 25 30

Deflection [mm]

Va

[kN

]

3132333435

Fig. 38. Deflection on line V close to the line load, slabs 5–8.

0

20

40

60

80

100

120

0 5 10 15 20 25 30

Deflection [mm]

Va

[kN

]

3637383940

Fig. 39. Deflection on line VI in the middle of slabs 5–8.

Page 430: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

430

0

20

40

60

80

100

120

0 5 10 15 20 25 30

Deflection [mm]

Va

[kN

]4142434445

Fig. 40. Deflection on line VII along end beam, slabs 5–8.

0

20

40

60

80

100

120

0 5 10 15 20 25Deflection [mm]

Va

[kN

]

13, End beam28, Super43, End beam

Fig. 41. Net deflection of midpoint of middle beam (28) and those of end beams (13, 43). (Settlement of supports eliminated.)

10.2 Crack width

0

20

40

60

80

100

120

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0Crack width [mm]

Va

[kN

]

5678910

Fig. 42. Differential displacement ( crack width) measured by transducers 5–10.

0

20

40

60

80

100

120

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0

Crack width [mm]

Va

[kN

]5678910

Fig. 43. Same as previous figure but the cyclic loading phase is not shown.

10.3 Average strain (actually differential displacement)

0

20

40

60

80

100

120

-2,0 -1,5 -1,0 -0,5 0,0Differential displacement [mm]

Va

[kN

]545556 beam57 beam5859

Fig. 44. Differential displacement at top surface of floor measured by transducers 54–59.

0

20

40

60

80

100

120

0,0 0,5 1,0 1,5 2,0 2,5Differential displacement [mm]

Vp

[kN

]

606162 beam63 beam6465

Fig. 45. Differential displacement at soffit measured by transducers 60–65.

Page 431: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

431

10.4 Shear displacement

0

20

40

60

80

100

120

-2,5 -2,0 -1,5 -1,0 -0,5 0,0 0,5Differential displacement [mm]

Vp

[kN

]

46 Slab 147 Slab 148 Slab 549 Slab 5

Fig. 46. Northern end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

0

20

40

60

80

100

120

-2,5 -2,0 -1,5 -1,0 -0,5 0,0 0,5Differential displacement [mm]

Vp

[kN

]

50 Slab 451 Slab 452 Slab 853 Slab 8

Fig. 47. Southern end of middle beam. Differential displacement between edge of slab and middle beam. A negative value means that the slab is moving towards the end of the beam.

Fig. 48. Shear displacement = differential displacement at upper edge – differential displacement at lower edge of slab.

0

20

40

60

80

100

120

0,0 0,5 1,0 1,5 2,0 2,5Shear displacement [mm]

Va

[kN

]

46-47 Slab 148-49 Slab 550-51 Slab 452-53 Slab 8

10.5 Strain

0

20

40

60

80

100

120

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8Strain [10-3]

Va

[kN

]

66

67

70

71

Fig. 49. Strain measured by gauges 66, 67, 70 and 71.

0

20

40

60

80

100

120

-1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0Strain [10-3]

Va

[kN

]68697273

Fig. 50. Strain measured by gauges 68, 69, 72 and 73.

Page 432: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

432

11 Reference tests

P

P

1 2 3

456

7

8

1 (6) 2 (5) 3 (4)

8 (7)

Gypsum

35353535

8500 (Test R9/1)

1300

9524 (Test R9/2)

3565

a)

b)

Fig. 51. Layout of reference test. a) Plan. b) Elevation. Test R9/2 was carried out first.

0

50

100

150

200

250

300

0 5 10 15 20 25 30 35 40

Time [min]

P [k

N]

R9/2R9/1

Fig. 52. Actuator force – time relationship.

0

50

100

150

200

250

300

0 5 10 15 20 25 30 35 40

Deflection [mm]

P [

kN]

123456

R9/2

0

50

100

150

200

250

300

0 5 10 15 20 25 30 35 40

Deflection [mm]

P [k

N] 1

23456

7

R9/1

Fig. 53. Displacements measured by transducers 1–6. P is the actuator force.

Page 433: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

433

0

50

100

150

200

250

0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35

Slippage [mm]

P [k

N]

78

R9/2

0

50

100

150

200

250

300

350

0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35

Slippage [mm]

P [

kN]

78

R9/1

Fig. 54. Slippage of outermost strands measured by transducers 7–8. P is the actuator force. Table. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure, weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

Pa kN

Peq kN

Vobs kN

vobs kN/m

Note

R9/2 24.1.2002 9519 21,2 230,7 0,7 221,3 184,4 Web shear failure R9/1 24.1.2002 8500 19,0 288,3 0,7 264,4 220,3 Flexural shear failure Mean 242,8 202,4

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 127,5 kN per one slab unit or 106,3 kN/m. This is 53% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the removed temporary supports and imposed actuator loads (deflection minus settlement of supports) was 17,5 mm or L/274, i.e. rather small. It was 3,1–3,3 mm greater than that of the end beams.

2. The net deflection of the middle beam due to the imposed actuator loads only (deflection minus settlement of supports) was 15,9 mm or L/300.

3. The shear resistance measured in the reference tests was 10% lower than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

4. The maximum difference in the net mid-point deflection of the beams was less than 3,3 mm. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs.

5. The bond between the cast-in-situ concrete and the edges of the hollow cores was weak.

6. The edge slabs slided 0,13 … 0,23 mm along the beam before failure. This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance.

7. The transverse shear deformation of the edge slabs was considerable which can be seen in Figs 47–49.

8. The failure mode was web shear failure of edge slabs. The Super beam seemed to recover completely after the failure even though it obviously had cracked in flexure.

Page 434: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

A434

APPENDIX A: DETAILS OF SUPER BEAM

Page 435: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

A435

Page 436: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

A436

Page 437: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

B437

APPENDIX B: PHOTOGRAPHS

Fig. 1. Tie reinforcement at the edge of the floor. Fig. 2. Overview on arrangements.

Fig. 3. Loading arrangements.

Fig. 4. Transducers measuring average strain in beam’s direction.

Page 438: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

B438

Fig. 5. Arrangements at end beam.

Fig. 6. Transducers measuring sliding of slabs along middle beam.

Fig. 7. Arrangements for line loads.

Fig. 8. Failure of slab 5.

Fig. 9. Failure of slab 1.

Fig. 10. Diagonal crack in slab 8 after failure.

Page 439: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

B439

Fig. 11. Failure of slab 4.

Fig. 12. Vertical cracking of end beam between slabs 6 and 7.

Fig. 13. Wide crack along the western edge of middle beam next to slab 2.

Fig. 14. Failure cracks in slab 2.

Fig. 15. Cracks in slab 4 after failure.

Fig. 16. Cracks in slabs 2–4 after failure.

Page 440: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

B440

Fig. 17. Cracks in slab 5 after failure.

Fig. 18. Cracks in slab 1 after failure.

Fig. 19. Soffit of slabs 3 and 4 after failure.

Fig. 20. Soffit of slabs 1–2 after failure.

Page 441: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

B441

Fig. 21. Failed ends of slabs 3–4 after failure.

Fig. 22. Western side of middle beam. Note the bond failure along the vertical interface of the cast-in-situ concrete and the precast beam as well as the intact core fillings.

Fig. 23. Eastern side of middle beam after demolition.

Fig. 24. Western side of middle beam after demolition.

Page 442: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CP.Super.320.2002

B442

Fig. 25. Intact core fillings after failure. Note the geometric imperfections at the end.

Fig. 26. Web shear failure in reference test R9/2.

Fig. 27. Web shear failure in reference test R9/2.

Fig. 28. Flexural shear failure in reference test R9/1.

Fig. 29. Flexural shear failure in reference test R9/1.

Page 443: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

443

1 General information

1.1 Identification and aim

TUT.CP.LB.320.2002 Last update 2.11.2010

LB320 (Internal identification)

Aim of the test To quantify the interaction between LB beam and hollow core slabs.

1.2 Test type

Middle beam (LB)End beam End beam

Fig. 1. Overview on test arrangements. LB beam in the middle, steel beams (square tubes) at the ends.

1.3 Laboratory & date of test

TUT/FI (Tampere University of Technology) 19.6.2002

1.4 Test report

Author(s) Suonio, M., Taskinen A.

Name LUJABEAM-palkin (LB) laatastokoe (Test on hollow core floor with LUJABEAM (LB), in Finnish)

Ref. number -

Date 28.8.2002

Availability Confidential, owner is

Lujabetoni Oy

Harjamäentie 1

FI-71800 Siilinjärvi

Finland

2 Test specimen and loading (see also Appendices A)

Page 444: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

444

2.1 General plan

Fig. 2. Plan. Span of beams 4,8 m.

2.2 End beams

Fig. 3. Arrangements at end beam. 8 refers to a reinforcing bar T8, see 2.3.

2.3 Middle beam

The beam, see Figs 4–7, comprised a precast and prestressed concrete component provided with shear keys and two L-shaped steel ledges.

Page 445: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

445

L-profile, steel

Precast prestressedconcrete

Shear keys50x220x10 c/c 100

Fig. 4. Illustration of LB beam.

Fig. 5. Design of LB beam. Txy refers to reinforcing bar A500HW with diameter xy, see 2.3.

Page 446: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

446

Fig. 6. Sections A-A, B-B and C-C. Txy refers to reinforcing bar A500HW, see 2.3.

Fig. 7. Detail 1. Design of ledges.

Page 447: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

447

The prestressed part was cast by Lujabetoni Oy in their Siilinjärvi factory 25.4.2002 Concrete: K80, max aggregate size 16 mm, rapidly hardening cement

Passive reinforcement and tendons in LBL beam:

Txy: Hot rolled, weldable rebar A500HW, = xy mm J12,9: Prestressing strand, 7 wires, =12,9 mm, Ap = 100 mm2, prestress = 1250 MPa, low relaxation (nominal value 2,5% at = 0,7fpu) Structural steel: S355J2G3, fy 355 MPa (nominal value) unless otherwise specified

2.4 Arrangements at middle beam

- Simply supported, span = 4,8 m

Fig. 8. Section along hollow cores, see Fig. 2.

Fig. 9. Section along joint between adjacent slab units, see Fig. 2. The rebars are made of A500 HW.

Fig. 10. Section along outer edge of floor specimen, see Fig. 2. The rebars are made of A500 HW.

Page 448: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

448

2.5 Slabs

Fig. 11. Nominal geometry of slab units (in scale).

- Extruded by Lujabetoni Oy, Siilinjärvi factory, date not given in the report - 11 lower strands J12,5 initial prestress 1100 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

39,3

59,4

37,8

226,3

bw,i = 311,7

bw,i

1167 (at mid-depth)

Fig. 12. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 1,9 mm in slab unit 4, 1,8 mm in slab units 1 and 6, 1,7 in slab units 4, 5, 8 and 2 x 1,7 in slab unit 6 Measured weight of slab units = 5,33 kN/m

2.6 Temporary supports

There were no temporary supports below beams.

Page 449: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

449

2.7 Loading arrangements

Fig. 13. Section A-A in Fig. 2. Palkin laipan katkaisu reunavalun tasalle = the ledge of the beam was cut along the edge concrete.

3 Measurements

3.1 Support reactions

Fig. 14. Load cells 60, 63, 68 and 69 measuring the force in the tension bars, see also Fig.13. Load cells 61, 62, 67 and 64–66 below the supports of the LB beam.

Page 450: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

450

3.2 Vertical displacement

Fig. 15. Location of transducers 1–18 for measuring vertical deflection of floor.

3.3 Average strain in mid-span and crack width along edges of middle beam

Fig. 16. Position of device (transducers 26, 27, 28 and 30) measuring average strain parallel to the beams. Numbers in parentheses refer to the soffit of the floor, others to the top. Position of transducers 19–24 for measuring crack width between LB beam and ends of hollow core slabs.

Page 451: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

451

3.4 Horizontal. displacements

See 3.3

3.5 Strain

Fig. 17. Strain gauges 40, 41, 46–49 measuring longitudinal strain of beam and strain gauges 42–45 measuring transverse strain of ledges.

4 Special arrangements

On top of the end beams shims were placed to simulate the camber of the middle beam in such a way that when the hollow core slabs were installed, all corners of the end beams touched the supporting beams. All cast-in-situ concrete (K30, max aggregate size 8 mm) was taken from the same batch. The date of casting was 4.6.2002. The ledges of the LB.beam were flame-cut along the outer edges of the outermost hollow core slabs and holes for the tension bars were drilled through the hollow cores.

Page 452: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

452

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 19.6.2002. Before starting, all measuring devices were zero-balanced. The loading history is shown in Fig. 18.

Fig. 18. Actuator force P vs. time.

6 Observations during loading

In the figures below, P refers to the force in the hydraulic actuators.

Stage I (Cyclic)

At P = 75 kN the joint concrete between the middle beam and the slab units started to crack along the slab ends, and at P = 80 kN there was a continuous crack in the joint concrete on both sides of the beam along the whole length of the beam.

At P = 100 kN the cast-in-situ concrete cracked along the outer edge of slabs 1 and 5 and along the edge of slab 8.

At P = 120 kN first vertical cracks were observed in the tie beams above the end beams of the test specimens.

Stage II (Monotonous)

At P = 140 kN the cast-in-situ concrete (edge concrete) cracked along the outer edge of slab 8.

At P = 240 kN the joint concrete cracked along the edges of the middle beam in the mid-span of the beam.

At P = 260 kN a longitudinal crack was observed in slab 4, see Fig. 20.

At P = 283,4 a web shear failure took place in slab 8.

The cracking pattern after failure is shown in Figs 20–21 (top surface and edges) and in Fig. 19 (soffit after failure).

After failure See App. A, Figs 3–7. LB beam seemed intact after demolishing the slabs.

Page 453: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

453

7 Cracks in concrete

7.1 Cracks at service load

See Fig. 20

7.2 Cracks after failure

Fig. 19. Cracks in the soffit after failure.

Page 454: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

454

Fig. 20. Cracks on the top and at the edges of the floor at load P = 260 kN. The numbers give the value of actuator load P when the crack appeared.

Page 455: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

455

Fig. 21. Failure mode on the top and at the South edge (slabs 7 and 8).

Page 456: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

456

8 Observed shear resistance

The ratio (measured support reaction below one end of the middle beam)/ (load due to actuator forces on half floor) is shown in Fig. 22 and the ratio (measured support reaction below one end of the middle beam) / (theoretical support reaction due to actuator forces on half floor) in Fig. 23. The theoretical reaction is calculated assuming simply supported slabs, which means that the support reaction force is 84,2% of 2P. The measured shear force is 89,4% of 2P before failure. This comparison shows that the support reaction due to the actuator forces cannot be calculated accurately enough assuming simply supported slabs.

Fig. 22. Measured support reaction of the middle beam vs. actuator forces 2P. Only actuator loads are taken into account in the support reaction.

Fig. 23. Measured support reaction of one slab vs. theoretical support reaction due to actuator forces. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + VP

Page 457: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

457

where Vg,sl, Vg,jc, Veq and VP are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces P, respectively. VP is calculated from the measured support reactions below the middle beam. Vg,sl and Vg,jc are calculated assuming that the slabs behave as simply supported beams, but Veq is obtained from Veq = 0,8938xFeq because the measured support proved to be 89,38% of the imposed line load on one slab unit. The values for the components of the shear force are given in Table below. Table 1. Components of shear resistance due to different loads.

Action Load Shear force

kN

Weight of slab unit 18,9

Weight of joint concrete 0,8

Loading equipment 2,8

Actuator loads (283,4)/2 kN 126,7 The observed shear resistance Vobs = 149,2 kN (shear force at support) is obtained for one slab unit with width = 1,2 m. The shear force per unit width is vobs = 124,3 kN/m

9 Material properties

9.1 Strength of steel

Component ReH/Rp0,2 MPa

Rm MPa

Note

L-profiles 355 Nominal (S355J2G3C)

Slab strands J12,5 1570 1770 Nominal (no yielding in test) Beam strands J12,9 1630 1860 Nominal (no yielding in test) Reinforcement A500HW (Txy)

500 Nominal value for reinforcing bars (no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 ? 2) Upper flange of slab 8,

Mean strength [MPa] 65,7 vertically drilled

St.deviation [MPa] 6,48 Tested as drilled2)

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

3 50 50 ? 2) Upper flange of slab,

Mean strength [MPa] 72,9 vertically drilled

St.deviation [MPa] - Tested as drilled2)

Page 458: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

458

9.4 Strength of grout in joints

#

a

a

a

a mm

Date of test

Note

6 150 19.6.2002 Kept in laboratory in the same

Mean strength [MPa] 36,2 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,26

9.5 Strength of concrete in middle beam

#

a

a

a

a mm

Date of test

Note

6 100 19.6.2002 Kept in laboratory in the same

Mean strength [MPa] 90,1 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 2,85 1) Date of material test minus date of structural test (floor test or reference test)

2) Date is not given in the report, but it is very likely 19.–22.6.2002

10 Measured displacements

In the following figures, P stands for the actuator load.

10.1 Deflections

Fig. 24. Deflection in mid-span of slabs 1–4 measured by transducers 2–6.

Fig. 25. Deflection in mid-span of slabs 5–8 measured by transducers 7–11.

Fig. 26. Net deflection of midpoint of LB beam and those of end beams (1, 12). Settlement of supports is eliminated from deflection of LB beam.)

Page 459: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

459

10.2 Crack width

Fig. 27. Differential displacement ( crack width) measured by transducers 19–24.

10.3 Average strain (actually differential displacement)

Fig. 28. Differential displacement at top and bottom surface of floor measured by transducers 26, 27, 28 and 30.

10.4 Differential displacement

Fig. 29. Differential vertical displacement between top surface of LB beam and the end of hollow core slabs measured by transducers 13 and 14. A positive value means that the slab end deflects more than the beam.

Page 460: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

460

10.5 Strain

Fig. 30. Longitudinal strain in ledges measured by gauges 40 and 41.

Fig. 31. Transverse strain in ledges measured by gauges 42, 43 and 45. The strain measured by gauge 44 is not shown because it was clearly erroneous.

Fig. 32. Longitudinal concrete strain in LB beam measured by gauges 47, 48 and 49. The strain measured by gauge 46 is not shown because it was clearly erroneous.

Page 461: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

461

11 Reference tests

Fig. 33. Layout of reference test and load – mid-point deflection curve. See also App. A, Fig. 8.

Page 462: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

462

Table 2. Reference test. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure + weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

Pa+Peq kN

Vobs kN

vobs kN/m

Note

R1 17.6.2002 7120 20,9 343,0 313,3 261,1Web shear failure (flexural shear failure)

App. A, Fig. 8 shows that the lower end of the inclined failure crack is at a distance of 500 mm from the support. At this distance, assuming the losses of prestress equal to 10% and the transfer length of the prestressing force equal to 600–800 mm, the axial stress in the soffit = -2,9 … -0,1 MPa is obtained. This suggests that the failure mode could not be initiated by a flexural crack. Hence, the failure mode has been web shear failure rather than flexural shear failure.

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 149,2 kN per one slab unit or 124,3 kN/m. This is 48% of the shear resistance observed in the reference test. Note that in this case the sheared end of the reference slab was provided with cast-in-situ concrete simulating the grouting outside the beam end in floor test, see App. A, Fig. 8.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only

(deflection minus settlement of supports) was 21,3 mm or L/225.

2. The shear resistance measured in the reference test was a bit higher than the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005. This may be attributable to the cast-in-situ concrete at the sheared end in the reference test.

3. The maximum difference in the net mid-point deflection of the beams was of the order of 5–6 mm. An estimated value is given because the settlement of the supports of the end beams was not measured. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs.

4. The failure mode was web shear failure of edge slabs close to the supports of the middle beam (LB beam). The LB beam seemed to recover completely after the failure.

Page 463: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

A463

APPENDIX A: PHOTOGRAPHS

Fig. 1. Loading arrangements.

Fig. 2. Equipment for measuring average strain in hollow core slab.

Page 464: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

A464

Fig. 3. A step between LB beam and slab 4.

Fig. 4. Failure in slab 8.

Page 465: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

A465

Fig. 5. Soffit after failure. Slab 6 in the front, slabs 7 and 8 in the rear.

Fig. 6. Slab 8 after failure. The loose top part has been removed.

Page 466: Matti Pajari Prestressed hollow core slabs supported on beams ...

TUT.CP.LB.320.2002

A466

Fig. 7. Slab 8 after failure. All loose concrete material has been removed.

Fig. 8. Failure mode in reference test.

Page 467: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

467

1 General information

1.1 Identification and aim

VTT.S.WQ.500.2005 Last update 2.11.2010

WQ500 (Internal identification)

Aim of the test To study the shear resistance of 500 mm slab supported on steel beams.

1.2 Test type

Middle beam (WQ beam) End beam (HE 340A)End beam (HE 340A)

Fig. 1. Illustration of test setup. The end beams were hot-rolled steel beams.

1.3 Laboratory & date of test

VTT/FI 16.8.2005

1.4 Test report

Author(s) Pajari, M.

Name Load test on hollow core slab floor with steel beams

Ref. number RTE3405/05

Date 14.12.2005

Availability Available at www.rakennusteollisuus.fi

2 Test specimen and loading

Page 468: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A468

2.1 General plan

123

8

7200 (span of beam)

4

150

0 (

fro

m s

lab

en

d)

7200 (span of beam)

100

00

(Le

ngth

of

slab

)1

500

7200250

250

56

789101112

(span of beam)

No

rth

So

uth

West

East

Line load

Line load

Fig. 2. Plan.

Page 469: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

469

2.2 End beams

300

330

500

50 50

HE340A

5050

Concrete K30

Rebars 2 d 10L = 7200

Plywood

Steel

Roller bar

B B

16,5

9,5

Fig. 3. Arrangements at end beam.

Simply supported, span = 7,2 m, roller bearing below one end

2.3 Middle beam

- Manufactured by PPTH Oy and transported to VTT Research Hall 1 23.5.2005 - Simply supported, span = 7,2 m, roller bearing at one end

1200 1200 1200 117012001170230 230

7600

190

20

190

20

Two transverse plate stiffeners 440x480x20 inside the beam, welded to the inner surface of the box

Seven holes, d = 48 mm

A

A

Camber 4,0 mm

Steel S355

Fig. 4. Middle beam. Elevation.

100

500

500

30

40

150 150

8062

Steel pipes through the beam,inner diameter = 48 mm,c/c 1200

10

800

A A

Fig. 5. Cross-sectional geometry.

Page 470: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A470

2.4 Arrangements at middle beam

100 30

500

50 400

Circular hole through beam c/c 1200

500

500

Rebars 4 d 12 L = 7600

Rebars 5 d 20, L = 3500, one in each longitudinal joint between adjacent slabs

30

40

80

150 150

120

C C

Fig. 6. Section C-C (see Fig. 13) along a joint between adjacent hollow core units.

50 400

D D

EPS plug

Fig. 7. Section D-D (see Fig. 13) along hollow cores. Plugs made of expanded polystyrene.

100

30

500

50

50

80

Bent rebar d 20 L = 800

100

H H

E E

H H

Slab Slab50

150

Bent rebar d 20 L = 800

Hole through beam

Cast-in-situconcrete

Fig. 8. Tie reinforcement in the cast-in-situ concrete outside the edge of the outermost slabs (section E-E in Fig. 13). See also App. A, Fig. 9. Tie reinforcement: Horizontal rebars A500HW through the beam and parallel to the beam.

Page 471: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

471

2.5 Slabs

45

R50

45

410205

R120

R125R50

500

1200

3520

Fig. 9. Nominal geometry of slab units (in scale).

- Extruded by Parma Oy,

Hyrylä factory 28.4.2005

- Strands: 16 J 12,5, Ap = 93 mm2/strand, initial prestress = 1050 MPa

40,1

48,0

400,4

1153 (1161 at mid-depth)

41,8

1195

67,1

bw,i

bw,i = 339,7

Fig. 10. Most relevant measured geometrical properties.

Max measured bond slippage: 1,9 mm (in slab 11);

2x1,7 mm (in slabs 10 and 11);

2x1,6 mm (in slabs 3 and 8) - Measured weight = 6,49

kN/m

2.6 Temporary supports

No

2.7 Loading arrangements

An auxiliary loading frame was built above the test floor. It was tied by tension bars to the floor of the research hall, see Figs 11 and 12. Six tension bars penetrated the floor through the hollow cores outside the line loads, the rest were outside the test specimen. The loads were generated by 12 actuators. See Fig. 13 for the position of the actuators. Taking into account the weight of the loading equipment Peq = 6,14 kN/slab unit, the following relationship can be written for the line load on one slab:

F = Pa + 6,14 kN (1) Pa is the load in the actuator. The line loads were applied to the slab units by 24 tertiary steel beams of the type HE 120 A (a hot-rolled I-beam with depth = 114 mm, width = 120 mm and thickness of flange = 8 mm), each 550 mm in length. The top surface of the slabs under these beams was evened out by gypsum. On the top of the tertiary beams, secondary spreader beams were placed, each on two bearings. On the top of the secondary beams, primary spreader beams were installed. The friction between the primary and secondary spreader beams was eliminated with teflon sheets, and that

Page 472: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A472

between the secondary and tertiary spreader beams with a freely rolling circular steel bar, see Figs 14–16 The drifting of the primary spreader beams was prevented by the friction at the upper and lower end of the actuators. The upper end of each actuator was provided with a swivel (ball bearing).

2P

+4,5 m

780 220420 980 180102020

a 2Pa 2Pa 2Pa 2Pa 2Pa

Fig. 11. Auxiliary loading frame. Elevation. North edge on the right.

1000

10

00

Fig. 12. Auxiliary loading frame. Plan. The position of the tension bars is indicated by white circles above the blue and green beams. North edge on the right.

Page 473: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

473

P

P1

2

123

8

7200 (span of beam)

A A

B

C

4

600

1500

(fr

om

sla

b en

d)

E

E

B

7200 (span of beam)

D C

2P

600600600600600600600600600600600 1000

0 (L

eng

th o

f sl

ab)

1500

7200

D Ca

250

250

56

789101112

2Pa 2Pa 2Pa 2Pa 2Pa(span of beam)

Pri

mar

y

Tertiary Secondary

16377 16377 16378 16377 16378 16377

16377 16377 16377 1637716378 16378

No

rth

So

uth

Fig. 13. Loading arrangements. The slabs are from two casting lots: 16377 and 16378. The position of the actuator loads is indicated by black circles above the middle beam.

A A

Load cells 2, 3 and 4 under support of beam

Det 1

2Pa

2Pa

2Pa

2Pa

2Pa

2Pa

TertiarySecondary

Primary

7200

Fig. 14. Section A-A, see Fig. 13.

Page 474: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A474

Gypsum

Teflon plates

PSteel plate

FDet 1 F

F

F

L-profile

a Pa

Roller bar

Stiffening plates

Stiffening plates

Fig. 15. Detail 1, see Fig. 14.

3 Measurements

3.1 Support reactions

Below one end of the middle beam, the support reaction due to the actuator loads was measured by three load cells as shown in Figs 14 and 16.

1

7

3 load cells

Fig. 16. Load cells below the Northern support of the middle beam.

Page 475: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

475

3.2 Vertical displacement

G

123

8

4

600

1700

(f

rom

sla

b en

d)

E

E

600600600600600600600600600600600

1700

250

56

789101112

3233343536

V

38 37 IV

11131415 I17

VI

5355565759

464748495052 51

3940414243

VII

45 44

2526272829III

31 30

1819202122 II24 23

2600

2600

30 30 30 30 305050

250

30 30

Fig. 17. Location of transducers 11 … 59 for measuring vertical deflection along lines I … VII.

Page 476: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A476

3.3–3.4 Average strain and horizontal displacements

1234J

56

789101112

63 61

64

62

65

66

60 6030

250 250

250

150

150

G

G

67 (68)69 (70)

71 (72)73 (74)

75 (76)77 (78)

250

83 (84)

87 (88)

81 (82)

J

85 (86)

I I

Fig. 18. Position of transducers 61-66, 67–78 and 81–88 measuring crack width, average strain parallel to the beams and displacement of the slab edges relative to the beam, respectively.

L

Inductive transducer

Fig. 19. Apparatus for measuring average strain. L =1100 mm.

50

G G

150250250

50 150250250

20

69 73

70 74 78

20

20

77

Fig. 20. Section G-G, see Fig. 18.

I I

L-profile, glued to slab

L-profile, glued to slab83

84 Fig. 21. Section I-I, see Fig. 18.

J J

88

83

84

87

20

20

20

20

Fig. 22. Section J-J, see Fig. 18.

Page 477: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

477

4 Special arrangements

- None

5 Loading strategy

5.1 Load-time relationship

The loads were applied in two stages: Stage I (cyclic) and Stage II (monotonous) as shown in Fig. 23.

0

50

100

150

200

250

300

0 20 40 60 80 100 120 140 160 180

Time [min]

Pa [k

N]

Cyclic Monotonous

Fig. 23. Actuator force Pa vs. time. Date of test: 16.8.2005

5.2 After failure

-

6 Observations during loading (see also the photographs in App. A)

Before loading All measuring devices were zero-balanced when the actuator forces Pa were equal to zero but the weight of the loading equipment was on.

The cracks in the slabs were visually inspected and found to be the same as those observed before the slabs were installed. They are shown in Fig. 32 in which the initial cracks in the cast-in-situ concrete are also indicated. The maximum crack width in the soffit of the slabs was of the order of 0,06–0,08 mm. The initial longitudinal crack on the top of slab 12 was above the midmost web. It was not deep. As can be seen later, the initial cracks on the top of slabs 3, 4, 9 and 12 did not affect the failure.

Cycling loading Pa = 160 kN corresponds to the shear force due to the expected service load when the shear resistance of the slabs is supposed to be prevailing in the design.

Page 478: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A478

During the cyclic stage, the vertical interface between the cast-in-situ concrete of the middle beam and the sawn slab ends gradually cracked. At Pa = 109 kN, during the first load increase, the soffit of slab 10 cracked over the whole slab length, see Fig. 32 and App. A, Fig. 24. This crack may have been initiated near the 50 mm hole drilled for the vertical tension bars through the floor.

When the load was last time at the expected service level (Pa = 160 kN), the soffit of the slabs between the line loads and the middle beam was inspected visually. The visible cracks are shown in Fig. 32. There were some new cracks along the strands and some initial cracks had grown in length. The maximum crack width in these cracks was of the order of 0,08 … 0,10 mm. No difference between the widths in the initial and new cracks could be observed. The width of the long longitudinal crack observed at Pa = 109 kN in the soffit of slab 10 was of the order of 1,0 mm.

Pa = 213 kN An inclined crack was observed in slab 7 next to the middle beam.

Pa = 257 -259 kN A similar crack was observed in slabs 1 and 12.

Pa = 272 kN The crack in slab 12 grew in width and resulted in an abrupt shear failure. See Fig. 33 for all cracks and App. A, Figs 25–27 for the shear cracks in slabs 1, 7 and 12.

Observations after failure

When slab 12 failed, the loads on it were transferred to slab 11 over the longitudinal joint. The strength of this joint and the elastic energy stored in the loading frame made the floor fail in a complicated manner illustrated in Fig. 33 and in App. A, Figs 26–33. Despite the complexity of the crack pattern after the test, the origin of the failure was the shear crack in slab 12 next to the middle beam. About core filling After the test, the concrete filling of the slab ends next to the middle beam was investigated. In all hollow cores there was an empty space above the infill in the upper outer corner as shown in App. A, Figs 48–50. This was observed first after the end of slab 12 and the cast-in-situ concrete around it was broken during demolition. Fig. 24 shows the average geometry of the core infill for slabs 1 and 12. To illustrate the scatter, the geometry of the core infill for the individual cores is shown with dashed lines for slab 1.

Page 479: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

479

50 400

bcf =118 bcf =144

Slab 1 Slab 12

Fig. 24. a) Void filling seen in the beams’s direction. On the left: average infill in the cores measured from slab 1 and the measured infill in the individual cores shown with dashed lines. On the right: average measured infill in the cores of slab 12. The dimensions of the core infill for slab 1 were measured using a method shown in Fig. 25. The length of incomplete core filling was measured with a tape measure and subtracted from 400 mm to get bcf, the length of the “complete” infill. Due to the vertical dimension of the measuring tape, the zone of complete infill includes both the zone of 100 % filling and the zone where the open space above the infill was less than 10 mm in depth. The same 10 mm tolerance was also applied when measuring bcf for slab 12. As illustrated in Fig. 26, the open space above the infill, which is 10 mm or a bit more in depth, does not weaken the performance of the core infill against transverse shear.

cfb

10

Tape measure

400

Fig. 25. Measuring the length of complete infill using a tape measure.

Fig. 26. Incomplete core infill with 10 mm gap above it.

It is obvious that the incomplete infill shown in Fig. 26 and a 100% infill are equally effective in eliminating the transverse deformation of the webs. This justifies the measuring method. Fig. 50 in App. A shows how the pressure of the grout moved the EPS plug, glued with polyurethane to the concrete, forward along the core. There was a risk of collapse of the plug. For this reason, a more efficient vibration when compacting the grout could not be a solution for a better filling. When demolishing the floor it was observed that the weakest average core infill was in slab 1. The hollow cores in slab 12 were slightly more effectively filled than in some slabs and slightly less effectively filled than in other slabs. In this sense the core filling in slab 12 was representative to the whole floor.

Page 480: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A480

Observations on support conditions of slabs

The soffit of the slab units was not in complete contact with the middle beam when the slabs were installed and grouted, see Fig. 27. There were two reasons for this phenomenon. Firstly, the middle beam was stiffer than the end beams and had a precamber of 4 mm while the end beams were straight and deflected downwards due to their self weight. Due to these effects the slab ends were laying on non-parallel supports. Secondly, the soffit of the slabs was not completely planar but slightly curved downwards in transverse direction. Fig. 28 illustrates the typical joint between the outermost slabs and the ledge of the WQ beam. This gap was partly filled with the cement paste, and where wide enough, was also filled with the grout including aggregate. This is shown in App. A, Figs 53–59. At the support of the beam, the source of the grout below the slab was either the edge grouting as shown in Fig. 28 and App. A, Figs 41 and 44–47, or end grouting. After the test, the maximum gap width max was measured for the outermost slabs where possible. The results are given in the caption of Fig. 29.

Fig. 27. Typical gap between slab and beam flange. max = 1,3 mm, 3,8 mm and 5,5 mm for slabs 1, 6 and 7, respectively. For slab 12 the gap could not be measured after the failure.

1725

Fig. 28. Concrete cast outside the outermost edges of slabs intruded below the slab to some extent.

Fig. 29 shows the horizontal dimensions of a relatively thick grouting below the corners of the slab. These were measured using a steel wire which was 1 mm thick. Slab 1 was not checked because the wire was too thick for the gap. Slab 12 could not be measured because the concrete broken in the failure had filled the gap. A direct contact between the soffit of the slab end and the ledge of the beam or grout on the ledge represents a favourable support condition. In this test also other mechanisms to transmit the support reaction of the slab to the beam may have been present. The slab units were saw-cut but there was 10 mm deep zone at the bottom of the slab cross-section, which was not sawn but broken, see App. A, Fig. 52. The rough surface of this zone could work as a dowel, see Fig. 30. Even more important may have been the fact that the reinforced cast-in-situ concrete formed a beam which with the aid of the concrete in the cores may have transmitted the loads from the slabs to the bottom flange of the beam. This load-carrying mechanism may have been effective enough to transmit the loads even without any contact between the flange of the beam and the precast slab unit as shown in Fig. 31.

Page 481: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

481

12

6

7

1

Fig. 29. The space between slab and the flange of the beam was partly filled with the jointing concrete. The filled areas were measured for slabs 6 and 7. They are drawn in scale and shown in red color.

Grout below slab end Rough slab end Fig. 30. Details affecting the transmission of support reaction between slab and beam. On the left: Grout below slab end. On the right: Rough slab end.

Gap below slab end

BA

C

Fig. 31. Possible load-carrying mechanisms through cast-in-situ concrete when precast slab unit and ledge of beam are not in contact.

Page 482: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A482

7 Cracks in concrete

7.1 Cracks at service load

123456

789101112

A

AA

AA

AA

A

A

AA

AA

A

A

A109109 129109149

129

A

A

160

160

140

AA

119

A

A

A

A

160 A

A

AA

AA

257

AAAA

109

109

A A A A

AAAA

A

A

A

A

A

A

A

A A A A A A A

AAAAA

160

160 160

160160

160160

160

160

160

160

160160

160So

uth

No

rth

Fig. 32. Cracks at service load (Pa = 140 kN). The initial cracks observed before loading are indicated with red colour and letter A. A dashed line indicates a crack in the soffit. The numbers give the value of the actuator force at which the crack (other than initial crack) was observed.

Page 483: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

483

7.2 Cracks after failure

123456

789101112

A

AA

AA

AA

A

A

AA

AA

A

A

A257253243

253245

109109 129109

257

149

193

129122272

257

A

A

160

160

140

AA

191119

191

A

A

A

A

160

177

A

A

AA

AA

257

213

259

272

272

272

272

272

272

272

272272

272

257

213

AAAA

272272

272

109

109

A A A A

AAAA

A

A

A

A

A

A

A

A A A A A A A

AAAAA

272

160

160 160160

160

160

160160

160

160

160

160160

160

So

uth

No

rth

Fig. 33. Cracks after failure. The initial cracks are indicated with red colour and letter A. A dashed line indicates a crack in the soffit. The numbers give the value of the actuator force at which the crack was observed.

Page 484: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A484

8 Observed shear resistance

The ratio (measured support reaction below one end of the middle beam) / (actuator forces on half floor) is shown in Fig. 34 and in a larger scale in Fig. 35.

0

0,2

0,4

0,6

0,8

1

1,2

0 50 100 150 200 250 300

Pa [kN]

Rp,

obs/

(6*P

a)

Fig. 34. Ratio of measured support reaction of the middle beam (Rp,obs) to actuator loads on half floor.

0,8240,8260,8280,8300,8320,8340,8360,8380,8400,8420,8440,8460,848

0 50 100 150 200 250 300

Pa [kN]

Rp,

obs/

(6*P

a)

Fig. 35. A detail of the previous figure in a larger scale. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pa, respectively. Vg,sl and Vg,jc, are calculated assuming that the slabs behave as simply supported beams. Vg,jc is calculated from the nominal geometry of the joints and density of the concrete, other components of the shear force from measured loads and weights. For Veq and Vp the relationship given in Fig. 35 is applied. This means that Veq = 0,847xPeq and Vp = 0,847xPa. The values for the components of the shear force are given in the Table on the next page.

Page 485: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

485

Table. Components of shear resistance due to different loads.

Action Load Shear force kN

Weight of slab unit 6,49 kN/m 32,13 Weight of joint concrete 0,39 kN/m 1,93 Loading equipment 6,14 kN 5,20 Actuator loads 272,00 kN 230,38

The observed shear resistance Vobs = 269,6 kN (shear force at support) is obtained for one slab. The shear force per unit width is 224,7 kN/m.

9 Material properties

9.1 Strength of steel

Middle beam Thickness

mm Strength Re

1) MPa

Top flange 40 388

Bottom flange 30 388

Web 10 407

1) Measured yield strength according to certificate of compliance

ReH/Rp0,2 Rm Component

MPa MPa Note

End beam 350 Nominal (no yielding)

Strands J12,5 1630 1860 Nominal (no yielding)

Reinforcement 500 Nominal (A500HW,no yielding)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 30.8.2005 Upper flange of slabs 9

Mean strength [MPa] 82,0 (+14 d)1) vertically drilled, tested as

St.deviation [MPa] 1,1 drilled2), density = 2363 kg/m3

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 30.8.2005 Upper flange of slabs 12

Mean strength [MPa] 84,4 (+14 d)1) vertically drilled, tested as

St.deviation [MPa] 2,1 drilled2), density = 2363 kg/m3

Page 486: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A486

9.3 Strength of slab concrete, reference test

#

Cores h

d

h mm

d mm

Date of test From

6 50 50 30.8.2005 Upper flange of slab 13,

Mean strength [MPa] 86,8 (+1 d)1) vertically drilled, tested as

St.deviation [MPa] 4,2 drilled2), density = 2430 kg/m3

9.4 Strength of grout

#

a

a

a

a mm

Date of test

Note

6 150 16.8.2005 Kept in laboratory in the same

Mean strength [MPa] 31,3 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 1,3 Density =2195 kg/m3 1) Date of material test minus date of test (floor test or reference test)

2) kept in a closed plastic bag after drilling until compression

10 Measured displacements

In the following figures, Pa is the actuator force.

10.1 Deflections

0

50

100

150

200

250

300

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]

11

13

14

15

17

Fig. 36. Deflection on line I along Western end beam.

0

50

100

150

200

250

300

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]

18

19

20

21

22

23

24

Fig. 37. Deflection on line II in the middle of slabs 1–6.

0

50

100

150

200

250

300

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

] 25

26

27

28

29

30

31

Fig. 38. Deflection on line III close to the line load, slabs 1–6.

0

50

100

150

200

250

300

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]

32

33

34

35

36

37

38

Fig. 39. Deflection on line IV along the middle beam.

Page 487: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

487

0

50

100

150

200

250

300

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]

39

40

41

42

43

44

45

Fig. 40. Deflection on line V close to the line load, slabs 7–12.

0

50

100

150

200

250

300

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]

46

47

48

49

50

51

52

Fig. 41. Deflection on line VI in the middle of slabs 7–12.

0

50

100

150

200

250

300

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]

53

55

56

57

59

Fig. 42. Deflection on line VII along Eastern end beam, slabs 7–12.

0

50

100

150

200

250

300

0 5 10 15 20 25

Deflection [mm]

Pa

[kN

]

14

35

56

Fig. 43. Net deflection of midpoint of middle beam (35) and those of end beams (14, 56) (Rigid body motion due to settlement of supports eliminated).

10.2 Crack width

0

50

100

150

200

250

300

0,0 0,5 1,0 1,5 2,0 2,5

Differential displacement [mm]

Pa

[kN

] 61

62

63

64

65

66

Fig. 44. Differential displacement parallel to the slab between the middle beam and the slabs (≈ crack width). See Fig. 18 for the location of the transducers.

Page 488: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A488

10.3 Average strain

0

50

100

150

200

250

300

-1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0

Displacement [mm]

Pa

[kN

] 67

69

71

73

75

77

Fig. 45. Differential displacement at top surface of floor measured by transducers 57, 59, 61, 63, 65 and 67.

0

50

100

150

200

250

300

0,0 0,5 1,0 1,5 2,0

Displacement [mm]

Pa

[kN

] 68

70

72

74

76

78

Fig. 46. Differential displacement at soffit of floor measured by transducers 58, 60, 62, 64, 66 and 68.

10.4 Shear displacement

0

50

100

150

200

250

300

0,0 0,5 1,0 1,5 2,0 2,5

Displacement [mm]

Pa

[kN

]

81, slab 1 top

82, slab 1 bot

85, slab 7 top

86, slab 7 bot

Fig. 47. Northern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

0

50

100

150

200

250

300

0,0 0,5 1,0 1,5 2,0 2,5

Displacement [mm]

Pa

[kN

]

83, slab 6, top

84, slab 6 bot

87, slab 12 top

88, slab 12 bot

Fig. 48. Southern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

0

50

100

150

200

250

300

0,0 0,2 0,4 0,6 0,8 1,0

Shear displacement [mm]

Pa

[kN

]

81-82, slab 1

83-84, slab 6

85-86, slab 7

87-88, slab 12

Fig. 49. Differential displacement between top and bottom edge of slabs 1, 6, 7 and 12.

Page 489: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

489

11 Reference tests

One end of slab 13 was loaded in shear as shown in Fig. 50. Test slab 13 was taken from the same casting lot as slab 12 which failed in the floor test. In the reference test the span of the slab was 9900 mm. At actuator load Pa = 250 kN (Vp = 427 kN) a flexural crack was observed below the line load. A web shear failure took place at Pa = 362,5 kN. No remarkable slippage of the strands was observed before the failure.

The loading strategy is shown in Fig. 51. The failure mode is shown in Fig. 52and in App. A, Figs 62 and 63. The aim was to load both ends of slab 13. This was not possible because the other slab end deteriorated in the first test. The measured displacements are given in Fig. 53.

The shear resistance 650,7 kN observed in the test is higher than the average value for normal production.

5050

15002P

L

Gypsum

Neoprene Steel plate

50

1 (2)

3 (4)5 (6)

300

300

650

1

2

3

4

5

6

P

P

50

50

R R

R Ra

a

a

Fig. 50. Layout of reference test. For L, see the next table.

Page 490: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

A490

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30 35 40

Time [min]

Pa

[k

N]

Fig. 51. Actuator force – time relationship.

280

1200

1090

200

P

Pa

a

Fig. 52. Failure mode

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30 35 40

Displacement [mm]

Pa

[k

N] 1

23456

Fig. 53. Displacements measured by transducers 1–6.

Table. Span of slab L, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure, weight of loading equipment Peq, shear force Vp due to imposed load at failure, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date L

mm Vg kN

Pa kN

Peq kN

Vpa+eq kN

Vobs kN

vobs kN/m

R1 29.8.2005 9900 31,63 362,5 0,29 619,06 650,7 542,2

Page 491: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.S.WQ.500.2005

491

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 269,6 kN per one slab unit or 224,7 kN/m. This is 41% of the shear resistance observed in the reference test.

13 Discussion

1. At failure, the net deflection of the middle beam due to the imposed actuator load (deflection minus settlement of supports) was 21,2 mm or L/340, i.e. rather small.

2. The shear resistance measured in the reference test was considerably higher than the mean of observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

3. The shear resistance observed in the floor test was 41% of that in the reference test.

4. The core fillings in the floor tests were not perfect. This may have affected the shear resistance.

5. The torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs because the maximum difference in the net mid-point deflection was less than 4,7 mm.

6. The bond between the smooth edges of the middle beam and the grout was weak.

7. The bond between the soffit of the slab and the grout below it was also weak.

Due to the weak bond, the edge slabs slided along the beam before failure. This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance

Page 492: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A492

APPENDIX A: PHOTOGRAPHS

Fig. 1. WQ beam.

Fig. 2. Initial crack in slab 1.

Page 493: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A493

Fig. 3. Initial cracks in slab 2.

Fig. 4. Initial crack in slab 3.

Page 494: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A494

Fig. 5. Initial crack in slab 4.

Fig. 6. Initial cracks in slab 5.

Page 495: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A495

Fig. 7. Initial crack in slab 7.

Fig. 8. Initial crack in slab 8.

Page 496: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A496

Fig. 9. Initial cracks in slab 9.

Fig. 10. Initial crack in slab 11.

Page 497: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A497

Fig. 11. Slabs 1,2,6,7,8 and 12 in their final position.

Fig. 12. Slab 12 on WQ beam and a tie bar � 20 mm.

Page 498: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A498

Fig. 13. A short, bent tie bar, outer edge of slab 1.

Fig. 14. Support conditions above end beam.

Page 499: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A499

Fig. 15. Initial bending crack in slab 3 at a distance of 1050 mm from slab end.

Fig. 16. Initial bending crack in slab 9 at a distance of 1350 mm from slab end.

Page 500: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A500

Fig. 17. Overview on test arrangements.

Fig. 18. View on the loading frame and spreader beams.

Page 501: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A501

Fig. 19. Actuators above primary spreader beams.

Fig. 20. Arrangements between spreader beams. Note the white teflon sheets between the primary and secondary spreader beams.

Page 502: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A502

Fig. 21. Three orange load cells below one support of WQ beam.

Fig. 22. North end of WQ beam before loading.

Page 503: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A503

Fig. 23. North end of WQ beam before loading.

Fig. 24. Longitudinal crack in the soffit of slab 10 at Pa = 160 kN. The cracking took place at Pa = 109 kN.

Page 504: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A504

Fig. 25. Inclined crack in slab 7 at Pa = 213 kN.

Fig. 26. Failure of slab 12 at Pa = 272 kN.

Page 505: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A505

Fig. 27. Failure of slab 12 at Pa = 272 kN.

Fig. 28. Failure of slab 12 at Pa = 272 kN.

Page 506: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A506

Fig. 29. Failure of slab 12 at Pa = 272 kN.

Fig. 30. Failure of slabs 11 and 12 at Pa = 272 kN.

Page 507: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A507

Fig. 31. Failure of slabs 11 and 12 at Pa = 272 kN.

Fig. 32. Slabs 11 and 12 after removing the loading equipment.

Page 508: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A508

Fig. 33. Slabs 11 and 12 after removing the loading equipment.

Fig. 34. Slab 7 after test. Cracks in tie beam. The read line and capital A indicate an initial crack.

Page 509: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A509

Fig. 35. Slab 8 after test. Cracks in tie beam. The read line and capital A indicate an initial crack. The nonuniform colour is due to a mortar treatment carried out after demolding.

Fig. 36. Slab 9 after test. Cracks in tie beam.

Page 510: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A510

Fig. 37. Slab 10 after test. Cracks in tie beam.

Fig. 38. Slab 11 after test. Cracks in tie beam.

Page 511: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A511

Fig. 39. Slab 12 after test. Cracks in tie beam.

Fig. 40. Slab 1 after test.

Page 512: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A512

Fig. 41. Slab 1 after test.

Fig. 42. Slab 6 after test.

Page 513: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A513

Fig. 43. Slab 12 after test.

Fig. 44. Slab 1 after test.

Page 514: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A514

Fig. 45. Slab 7 after test.

Fig. 46. Slab 7 after test.

Page 515: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A515

Fig. 47. Slab 6 after test.

Fig. 48. Failure surface at end of slab 1. Note the incomplete filling of the cores.

Page 516: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A516

Fig. 49. Concrete filling taken from one core of slab 12.

Fig. 50. Concrete filling in one core of slab 2. Note that the polystyrene plug is inclined due to the casting pressure. Consequently, the length of the filling at the bottom is greater than 400 mm.

Page 517: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A517

Fig. 51. Failure surface of slabs 11 and 12.

Fig. 52. Rough surface at slab end below even, saw-cut surface.

Page 518: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A518

Fig. 53. Changes in colour on the flange below slab 1 due to the concrete or cement paste intruding into the gap between the soffit of the slab and the steel flange. See also the vertical stripes along the vertical edge of the flange.

Fig. 54. Thin layers of grout as well as changes in colour on the flange below slab 1 due to the grout intruding into the gap between the soffit of the slab and the steel flange.

Page 519: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A519

Fig. 55. Thin layers of grout as well as changes in colour on the flange below slab 1 due to the grout intruding into the gap between the soffit of the slab and the steel flange.

Fig. 56. Thin layers of grout as well as changes in colour on the flange below slab 1 due to the grout intruding into the gap between the soffit of the slab and the steel flange.

Page 520: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A520

Fig. 57. A detail of grout below slab 6.

Fig. 58. Grout below slab 5.

Page 521: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A521

Fig. 59. Steel flange below slab 7. No clear sign of grout can be seen below the slab and above the flange.

Fig. 60. Overview on arrangements in reference test.

Page 522: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A522

Fig. 61. Loading arrangements in reference test.

Fig. 62. Failure pattern in reference test. South edge.

Page 523: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A523

Fig. 63. Failure pattern in reference test. North edge.

Page 524: Matti Pajari Prestressed hollow core slabs supported on beams ...
Page 525: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

525

1 General information

1.1 Identification and aim

VTT.PC.InvT.500.2006 Last update 2.11.2010

PC500 (Internal identification)

Aim of the test To study the shear resistance of 500 mm slab supported on concrete beams.

1.2 Test type

Middle beam (Prestressed concrete beam)End beam (HE 340B)End beam (HE 340B)

Fig. 1. Illustration of test setup. The end beams were hot-rolled steel beams.

1.3 Laboratory & date of test

VTT/FI 29.9.2005

1.4 Test report Author(s) Pajari, M.

Name Load test on hollow core slab floor with concrete beam

Ref. number VTT-S-2303-06

Date 9.3.2006

Availability Available at www.rakennusteollisuus.fi

2 Test specimen and loading

Page 526: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

526

2.1 General plan

123

8

7200 (span of beam)

4

1500

(fr

om s

lab

end

)

7200 (span of beam)

1000

0 (L

eng

th o

f sla

b)15

00

240

240

56

789101112

No

rth

So

uth

East

West

Line load

Line load

Fig. 2. Plan.

2.2 End beams

300

340

500

50 50

HE340B5050

Concrete K30

Rebars 2 T16L = 7100

Plywood

Steel

Roller bar

21,512

Fig. 3. Arrangements at end beam. Simply supported, span = 7,2 m, roller bearing below Northern end fy 355 MPa (nominal fy), did not yield in the test.

Page 527: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

527

2.3 Middle beam

- Cast by Betonimestarit Oy, 4.8.2005 - Concrete K80 - Simply supported, span = 7,2 m, roller bearing at both ends

28

280

500

7 holes throughbeam, c/c 1200

200200 480

10060

880

Chamfer20x20

Chamfer20x20

Fig. 4. Cross-sectional geometry.

49 48

96 66

48 48

48 74

48 48 48 49

48 66 96

4843

1313

36J12,5

47 4J12,5 + 2 A2

2 A1

Fig. 5. Longitudinal reinforcement. J12,5 refers to a prestressing strand; A1 and A2 to ribbed reinforcing bars, see below.

J12,5: Prestressing strand =12,5 mm, Ap = 93 mm2, p0 = 1300 MPa, nominal strength fp0,2/fp = 1630/1860 MPa, did not yield in the test A1: Rebar A500HW, 12 mm, L = 7500 mm, nominal yield strength fy = 500 MPa, did not yield in the test

A2: Rebar A500HW, 25 mm, L = 7500 mm, nominal yield strength fy = 500 MPa, did not yield in the test

1200 1200 2001200120012001200200

7600

Fig. 6. Middle beam. Elevation.

Page 528: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

528

Fig. 7. Middle beam.

Page 529: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

529

2.4 Arrangements at middle beam

Circular holes d 100 c/c 1200

Rebars 4 d 10 L = 7600

Rebars 5 d 20, L = 3500, one in each longitudinal joint between slabs

10060

Fig. 8. Section along a joint between adjacent hollow core units.

880

280

200 200

Neoprene10x20

10

500

60480 40060400

60

100

20

EPSplug

Fig. 9. Section along hollow cores. Plugs made of expanded polystyrene.

10

500

60

Rebar d 20, L = 800

100H H

E E

100

60

10060

H H

Slab Slab50

150

Rebar d 20, L = 800

Hole through beam

Cast-in-situconcrete

Fig. 10. Tie reinforcement in the cast-in-situ concrete outside the edge of the outermost slabs (section E-E in Fig. 15). See also App. A, Fig. 9.

Page 530: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

530

Tie reinforcement: Straight horizontal rebars A500HW through the beam and parallel to the beam, nominal yield strength fy = 500 MPa

2.5 Slabs

45

R50

45

410205

R120

R125R50

500

1200

3520

Fig. 11. Nominal geometry of slab units (in scale).

- Extruded by Parma Oy, Hyrylä factory 28.4.2005

39,1

47,5

401,6

1156 (1164 at mid-depth)

41,9

1195

67,1

bw,i

bw,i = 332,5

Fig. 12. Most relevant measured geometrical properties (average values).

In slabs 1–2, 5–8 and 12, one strand below the second web in the bottom layer was weakly bonded. Its slippage in all slab ends was 1,8–3,8 mm. In other strands the max measured slippage was: 2,1 mm in slab 11 2 x 1,9 mm (in slab 5); 3 x 1,8 mm in slabs 2, 7 & 8 - Measured weight =

6,54 kN/m

2.6 Temporary supports

No

2.7 Loading arrangements

An auxiliary loading frame was built above the test floor. It was tied by tension bars to the floor of the research hall, see Figs 13 and 14. Six tension bars penetrated the floor through the hollow cores outside the line loads, the rest were outside the test specimen. The loads were generated by 12 actuators. Taking into account the weight of the loading equipment Peq = 6,22 kN / slab unit, the following relationship can be written for the line load on one slab:

F = Pa + 6,22 Kn (1)

Pa is the load in the actuator. The line loads were applied to the slab units by 24 tertiary

Page 531: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

531

steel beams of the type HE 120 A ( a hot-rolled I-beam with depth = 114 mm, width = 120 mm and thickness of flange = 8 mm), each 550 mm in length. The top surface of the slabs under these beams was evened out by gypsum. On the top of the tertiary beams, secondary spreader beams were placed, each on two bearings. On the top of the secondary beams, primary spreader beams were placed. The friction between the primary and secondary spreader beams was eliminated with teflon sheets, and that between the secondary and tertiary spreader beams with a freely rolling circular steel bar, see Figs 15–17. The drifting of the primary spreader beams was prevented by the friction at the upper and lower end of the actuators. The upper end of each actuator was provided with a swivel (ball bearing).

2P

+4,5 m

780 220420 980 180102020

a 2Pa 2Pa 2Pa 2Pa 2Pa

Fig. 13. Auxiliary loading frame. Elevation.

1000

1000

Fig. 14. Auxiliary loading frame. Plan. The position of the tension bars is indicated by white circles above the blue and green beams.

Page 532: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

532

P

P1

2

123

8

7200 (span of beam)

A A

B

C

4

600

1500

(fr

om

sla

b en

d)

E

E

B

7200 (span of beam)

D C

2P

600600600600600600600600600600600 1000

0 (L

eng

th o

f sl

ab)

1500

7200 (span of beam)

D Ca

240

240

56

789101112

2Pa 2Pa 2Pa 2Pa 2Pa

16379 16379 16379 1637916378 16378

16379 16379 16379 1637916378 16378

No

rth

So

uth

East

West

Fig. 15. Loading arrangements. The slabs are from two casting lots: 16377 and 16378. The position of the actuator loads is indicated by black circles above the middle beam.

A A

Load cells 2, 3 and 4 under support of beam

Det 1

2Pa

2Pa

2Pa

2Pa

2Pa

2PaTertiary

SecondaryPrimary

7200

Fig. 16. Section A-A, see Fig. 15.

Page 533: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

533

Gypsum

Teflon plates

PSteel plate

FDet 1 F

F

F

L-profile

a Pa

Roller bar

Stiffening plates

Stiffening plates

Fig. 17. Detail 1, see Fig. 16.

3 Measurements

3.1 Support reactions

1

7

3 load cells

Fig. 18. Load cells below the Northern support of the middle beam.

Page 534: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

534

3.2 Vertical displacement

G

123

8

4

600

1700

(f

rom

sla

b en

d)

E

E

600600600600600600600600600600600

1700

56

789101112

3233343536

V

38 37 IV

1114 I17

VI

535659

464748495052 51

3940414243

VII

45 44

2526272829III

31 30

1819202122 II24 23

2600

2600

30 30 305050

240

12

30

16

30

5458

240

Fig. 19. Location of transducers 11 … 59 for measuring vertical deflection along lines I … VII.

Page 535: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

535

3.3 Average strain 123456

789101112

62

65

240

240

200

200

G

G

67 (68)69 (70)

71 (72)73 (74)

75 (76)77 (78)

60

60

Fig. 20. Position of device (transducers 67–78) measuring average strain parallel to the beams.

L

Inductive transducer

Fig. 21. Apparatus for measuring average strain. L = 1100 mm.

60

G G

200240240

69 73

78

20 77

7020

207460440 440

Fig. 22. Section G-G, see Fig. 20.

3.4 Horizontal displacements

1234E

56

789101112

63 61

64

62

65

66

60 6030

240

240

83 (84)

87 (88)

81 (82)

E

85 (86)

H H

Fig. 23. Transducers measuring crack width (61–66) and shear displacement at the ends of the middle beam (81–88). Transducers 82, 84, 86 and 88 are below transducers 81, 83, 85 and 87, respectively.

Page 536: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

536

H H

L-profile, glued to slab83

L-profile, glued to slab

84

Fig. 24. Section H-H, see Fig. 23.

E E

88

83

84

87

2020

220

20

Fig. 25. Section J-J, see Fig. 23.

4 Special arrangements

- None

5 Loading strategy

5.1 Load-time relationship

The loads were applied in two stages: Stage I and Stage II as shown in Fig. 26: Stage II represents the post-failure loading. Measured results are given only for Stage I.

Stages I and II

0

50

100

150

200

250

300

350

400

0 30 60 90 120 150 180 210

Time [min]

Pa [k

N]

I II

Fig. 26. Actuator force Pa vs. time. Date of test 29.9.2005

Page 537: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

537

5.2 After failure

-

6 Observations during loading (see also the photographs in App. A)

Before loading All measuring devices were zero-balanced when the actuator forces Pa were equal to zero but the weight of the loading equipment was on. The cracks in the slabs were visually inspected and found to be the same as those observed before the slabs were installed. They are shown in Fig. 27 in which the initial cracks in the cast-in-situ concrete are also indicated. The maximum crack width in the soffit of the slabs was of the order of 0,06–0,08 mm. As can be seen later, the initial cracks on the top of slabs 3 and 12 did not affect the failure. Pa = 140 kN corresponds to the shear force due to the expected service load when the shear resistance of the slabs is supposed to be prevailing in the design.

Cycling loading The interface between the joint concrete and the sawn slab ends gradually cracked vertically on both sides of the middle beam. At Pa = 140 kN (3rd cycle) the soffit of the floor was inspected visually. The observed cracks are shown in Fig. 27. There were diagonal cracks in the corners of slabs 4, 5 and 11, and some initial cracks had grown in length. The maximum width of these cracks was of the order of 0,08–0,10 mm.

Pa = 199 kN A sudden increase in deflection was observed in the Western part of the test floor. Simultaneously a vertical crack was observed in the Western tie beam between slabs 4 and 5.

Pa = 308 kN An inclined shear crack appeared in slab 1 next to the middle beam.

Pa = 353 kN Additional inclined shear cracks appeared in slabs 1 (next to the previous crack) and in slab 7. Since slabs 1 and 7 seemed unable to carry more load, the loads were quickly reduced to prevent the possible collapse of the loading equipment. Soon after the unloading, the test floor was reloaded (Stage II) to check, whether the load before the unloading was really the failure load. This proved to be the case. In stage II the maximum actuator load was Pa = 321,5 kN. The cracks observed after the failure are shown in Fig. 28.

After failure When removing the slabs, it came out that the bond between the slab ends and the underlying grout was weak, see App. A, Figs 27–30.

Page 538: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

538

7 Cracks in concrete

7.1 Cracks at service load

123456

789101112

A

AA

AA A

135

109

115

A

A

140119A

A

A

A

A

AA

A A

AA

A A

AA

AAA

A

AA

A

A

AAA

A A

A

A

A

A

AA

A

A

A

140

A

A

AA

A A

AA

AA

A

A

A

A

A

A AA

A

AAA

A

A

115

So

uth

West

No

rth

East

Fig. 27. Cracks at service load (Pai = 140 kN). The initial cracks observed before loading are indicated with red colour and letter A. A dashed line indicates a crack in the soffit. The figures give the value of the actuator force at which the crack (other than initial crack) was observed.

Page 539: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

539

7.2 Cracks after failure

123456

789101112

A

AA

AA A178

187135

260290109

260

115

A

A260

140119

199

AA

A210

A

A

AA

308

353

353

A A

AA

A A

AA

AAAA

A

AA

A

260

A

AAA

A A

A

A

A

A

210AA

A

A

A

140

199A

A

260

AA

353

353

A A260

AA

AA

A

A

A

A

A

A AA

A

AAA

A

A

115

A

So

uth

West

No

rth

East

Fig. 28. Cracks after failure. The initial cracks are indicated with red colour and letter A. A dashed line indicates a crack in the soffit. The figures give the value of the actuator force at which the crack was observed.

Page 540: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

540

8 Observed shear resistance

The ratio (measured support reaction below one end of the middle beam)/ (actuator forces on half floor) is shown in Fig. 29 and in a larger scale in Fig. 30.

0,00,10,20,30,40,50,60,70,80,91,0

0 50 100 150 200 250 300 350 400

Pa [kN]

Rp,

obs/

(6*P

a)

Fig. 29. Ratio of measured support reaction of the middle beam (Rp,obs) to actuator loads on half floor.

0,838

0,839

0,840

0,841

0,842

0,843

0,844

0,845

0,846

0 50 100 150 200 250 300 350 400

Pa [kN]

Rp

,obs

/(6*

Pa)

Fig. 30. A detail of the previous figure in a larger scale. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pa, respectively. Vg,jc is calculated from the nominal geometry of the joints and density of the concrete, Vg,sl from measured average weight of slabs, both assuming that the slabs behave as simply supported beams. For Veq and Vp the relation to the load is taken from the measured support reaction at failure, in other words, Veq = 0,842xPeq and Vp = 0,842xPa. The values for the components of the shear force are given in Table on the next page.

Page 541: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

541

Table. Components of shear resistance due to different loads.

Action Load Shear force kN

Weight of slab unit 6,54 kN/m 32,05

Weight of joint concrete 0,39 kN/m 1,91

Loading equipment 6,22 kN / slab 5,24

Actuator loads 353,0 kN / slab 297,20 The observed shear resistance Vobs = 336,4 kN (shear force at support) is obtained for one slab width = 1,2 m. The shear force per unit width is 280,3 kN/m

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

End beam 350 Nominal (no yielding)

Slab strands 1630 1860 Nominal (no yielding) Beam strands 1630 1860 Nominal (no yielding) Reinforcement 500 Nominal (A500HW,no yielding)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 12.10.2005 Upper flange of slab 1,

Mean strength [MPa] 85,4 (+13 d)1) vertically drilled, tested as

St.deviation [MPa] 1,72 drilled2), density = 2487 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test From

6 50 50 12.9.2005 Upper flange of slab 13,

Mean strength [MPa] 89,2 (+3 ... +4 d)1) vertically drilled, tested as

St.deviation [MPa] 2,84 drilled2), density = 2448 kg/m3

9.4 Strength of grout

#

a

a

a

a mm

Date of test

Note

6 150 29.9.2005 Kept in laboratory in the same

Mean strength [MPa] 46,6 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,97 Density = 2245 kg/m3

Page 542: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

542

9.5 Strength of beam concrete

#

a

a

a

a mm

Date of test

Note

6 150 29.9.2005 Kept in laboratory in the same

Mean strength [MPa] 100,1 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 1,02 Density = 2402 kg/m3 1) Date of material test minus date of test (floor test or reference test)

2) kept in a closed plastic bag after drilling until compression

10 Measured displacements

In the following figures, Pa is the actuator force.

10.1 Deflections

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25

Deflection [mm]

Pa

[kN

] 11

12

14

16

17

Fig. 31. Deflection on line I along Western end beam.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

] 18

19

20

21

22

23

24

Fig. 32. Deflection on line II in the middle of slabs 1–6.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]

25

26

27

28

29

30

31

Fig. 33. Deflection on line III close to the line load, slabs 1–6.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25

Deflection [mm]

Pa

[kN

]

32

33

34

35

36

37

38

Fig. 34. Deflection on line IV along the middle beam.

Page 543: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

543

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30

Deflection [mm]

Pa

[kN

]39

40

41

42

43

44

45

Fig. 35. Deflection on line V close to the line load, slabs 7–12.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25 30 35

Deflection [mm]

Pa

[kN

]

46

47

48

49

50

51

52

Fig. 36. Deflection on line VI in the middle of slabs 7–12.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25

Deflection [mm]

Pa

[kN

]

53

56

58

59

Fig. 37. Deflection on line VII along Eastern end beam, slabs 7–12.

0

50

100

150

200

250

300

350

400

0 5 10 15 20 25

Deflection [mm]

Pa [k

N]

14

35

56

Fig. 38. Net deflection of midpoint of middle beam (35) and those of end beams (14, 56) (Rigid body motion due to settlement of supports eliminated).

10.2 Crack width

0

50

100

150

200

250

300

350

400

0,0 0,5 1,0 1,5 2,0 2,5

Differential displacement [mm]

Pa

[kN

]

61

62

63

64

65

66

Fig. 39. Differential displacement parallel to the slab between the middle beam and the slabs (≈ crack width). See Fig. 23 for the location of the transducers.

Page 544: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

544

10.3 Average strain

0

50

100

150

200

250

300

350

-2,0 -1,5 -1,0 -0,5 0,0

Differential displacement [mm]

Pa

[kN

]67

69

71 (beam)

73 (beam)

75

77

Fig. 40. Differential displacement at top surface of floor measured by transducers 57, 59, 61, 63, 65 and 67.

0

50

100

150

200

250

300

350

0,0 0,5 1,0 1,5 2,0 2,5 3,0

Differential displacement [mm]

Pa

[kN

]

68

70

72 (beam)

74 (beam)

76

78

Fig. 41. Differential displacement at soffit of floor measured by transducers 58, 60, 62, 64, 66 and 68.

10.4 Shear displacement

0

50

100

150

200

250

300

350

-0,5 0,0 0,5 1,0 1,5

Differential displacement [mm]

Pa

[kN

]

81, slab 1 top

82, slab 1 bot

85, slab 7 top

86, slab 7 bot

Fig. 42. Northern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

0

50

100

150

200

250

300

350

-0,5 0,0 0,5 1,0 1,5 2,0

Differential displacement [mm]

Pa

[kN

]

83, slab 6 top

84, slab 6 bot

87, slab 12 top

88, slab 12 bot

Fig. 43. Southern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

Page 545: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

545

11 Reference tests

Both ends of slab 13 were loaded in shear as shown in Fig. 44.

5050

15002P

L

Gypsum

Neoprene Steel plate

50

1 (2)

3 (4)5 (6)

300

300

650

1

2

3

4

5

6

P

P

50

50

R R

R Ra

a

a

Fig. 44. Layout of reference test. For L, see the next table.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30 35 40

Time [min]

Pa

[kN

]

R1

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30

Time [min]

Pa

[kN

]

R2 Fig. 45. Tests R1 and R2. Actuator force – time relationship.

Page 546: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

546

0

50

100

150

200

250

300

350

0 5 10 15 20 25

Displacement [mm]

Pa

[kN

]123456

R1

0

50

100

150

200

250

300

-2 0 2 4 6 8 10 12 14

Displacement [mm]

Pa

[kN

]

123456

R2

Fig. 46. Tests R1 and R2. Displacements measured by transducers 1–6. In test R1, at Pa = 170 - 250 kN, transducer 4 was accidentaly disconnected from the data logger. Table. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure, weight of loading equipment Peq, shear force VPa+eq due to imposed load (=actuator load and weight of loading equipment) at failure, total shear force Vobs at failure for one slab and total shear force vobs per unit width. Test Date Span

mm Vg kN

Pa kN

Peq kN

VPa+eq kN

Vobs kN

vobs kN/m

R1 7.9.2005 9867 32,02 318,7 0,29 544,00 576,02 480,0 R2 8.9.2005 8370 27,16 296,8 0,29 491,00 518,17 431,8 Mean 547,1 455,9

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 336,4 kN per one slab unit or 280,3 kN/m. This is 61% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator load

(deflection minus settlement of supports) was 21,8 mm or L/330, i.e. rather small

2. The shear resistance measured in the reference tests was higher than the mean of observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

3. The torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs because the maximum difference in the net mid-point deflection was less than 5,8 mm

4. The bond between the smooth edges of the middle beam and the grout was weak.

5. The bond between the soffit of the slab and the grout below it was also weak.

6. Due to the weak bond, the edge slabs slided along the beam before failure. This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance

Page 547: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A547

APPENDIX A: PHOTOGRAPHS

Fig. 1. Failure mode in reference test R1.

Fig. 2. Failure mode in reference test R2.

Page 548: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A548

Fig. 3. Installing slabs on PC beam.

Fig. 4. Uneven surface of concrete beam due to air bubbles.

Page 549: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A549

Fig. 5. Initial crack in slab 3.

Fig. 6. Initial crack in slab 4.

Page 550: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A550

Fig. 7. Initial crack in slab 9.

Fig. 8. Initial crack in slab 10.

Page 551: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A551

Fig. 9. A short tie bar through beam at support.

Fig. 10. Initial crack in slab 3.

Page 552: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A552

Fig. 11. Initial crack in slab 12.

Fig. 12. Initial crack in slab 12.

Page 553: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A553

Fig. 13. Overview on test arrangements.

Fig. 14. Support arrangement at end beam.

Page 554: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A554

Fig. 15. Shear crack at Pa = 308 kN. The black line drawn 200 mm below the shear crack is a misprint which does not refer to a crack.

Fig. 16. Shear crack in slab 7 at Pa = 353 kN.

Page 555: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A555

Fig. 17. Failure in slab 1. Photographed after stage II. In stage I, the failure crack was the same but much thinner.

Fig. 18. Failure mode in slab 1.

Page 556: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A556

Fig. 19. Failure mode in slab 1.

Fig. 20. Cracks in soffit of slabs 4 and 5 after failure.

Page 557: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A557

Fig. 21. Crack in soffit of slab 11 after failure.

Fig. 22. Failure mode.

Page 558: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A558

Fig. 23. Core filling in slab 1.

Fig. 24. Grout at support after removal of slab. Note the perfect filling of the gap below the slab end.

Page 559: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A559

Fig. 25. Perfect filling of hollow core. Note the lack of bond between the cast-in-situ and precast concrete.

Fig. 26. The only observed incomplete filling in hollow core.

Page 560: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A560

Fig. 27. Cast-in-situ concrete below slab end. Good bond with slab, weaker bond with beam.

Fig. 28. Cast-in-situ concrete below slab end. Good bond with beam, weaker bond with slab.

Page 561: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.500.2006

A561

Fig. 29. Vertical cracking at slab ends took place along the web ob the beam.

Fig. 30. Vertical cracking at slab ends took place along the web ob the beam.

Page 562: Matti Pajari Prestressed hollow core slabs supported on beams ...
Page 563: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

563

1 General information

1.1 Identification and aim

VTT.CR.Delta.500.2005 Last update2.11.2010

DE500 (Internal identification)

Aim of the test To quantify the interaction between the Delta beam and 500 mm thick hollow core slabs.

1.2 Test type

End beam (HE 340A) End beam (HE 340A)Middle beam (Delta beam)

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 11.11.2005

1.4 Test report

Author(s) Pajari, M.

Name Load test on hollow core slab floor with Delta beam

Ref. number VTT-S-2555-06

Date 10.8.2006

Availability Confidential, owner is Peikko Finland Oy, P.O. Box 104, FI-15101 Lahti, Finland

2 Test specimen and loading (see also Appendices A and B)

Page 564: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

564

2.1 General plan

123

8

7200 (Span of beam)

A A

B

4

600

1500

(fr

om s

lab

end

)

E

E

B

7200 (Span of beam)

D C

600600600600600600600600600600600 1000

0 (L

eng

th o

f sla

b)15

00

7200

D C

430

56

789101112

(Span of beam)

Sou

th17485 17485 17485 174851748617486

17485 17485 17485 174851748617486

Nor

th

West

East Fig. 2. Plan.

2.2 End beams

300

330

500

50 50

HE340A

5050

Concrete K30

Rebars 2 T10L = 7200

Plywood

Steel

Roller bar

B B

16,5

9,5

Fig. 3. Arrangements at end beam. T10 refers to a reinforcing bar A500HW with diameter 10 mm.

Page 565: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

565

2.3 Middle beam

The beam, see Fig. 4 and App. B, comprised

- a steel box girder with inclined, perforated webs - a concrete component filling the empty space between the slab ends laying on the

bottom flange of the beam, cast by VTT in laboratory on the 27th of October 2005. Concrete: K30, max aggregate size 8 mm, consistency S4/16–21 cm Structural steel in Delta beam: S355

7610

200

20

19825 holes d 150 c/c 300 in each web plate

A

Camber 0,0 mmSteel S355

Fig. 4. Delta beam. The beam was provided with end plates, 20 mm in thickness.

500

430

30

200 2001100

305

145

50Circular holesd 150 c/c 300

Circular holesd 150 c/c 300

8

a)

b)

Fig. 5. Cross-section A-A of Delta beam. a) At web hole. b) Between web holes.

Page 566: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

566

2.4 Arrangements at middle beam

- Simply supported, span = 7,2 m, roller bearing at South end Rebars Txy: Hot rolled, weldable rebar A500HW, diameter = xy mm

23456

789101112

1

Rebars 5 d 20 L = 3500

Rebar d 20 L = 1050Rebar d 20 L = 1050

Rebars 1 + 1 d 12 L = 7600

Rebars 1 + 1 d 12 L = 7600

Fig. 6. Tie reinforcement across and along the middle beam.

500

50430

Rebars 2 d 12 L = 7600

Rebars 5 d 20, L = 3500, one in each longitudinal joint between adjacent slabs

30

20

120

C C

180 18020

1100

305140

145

50

Fig. 7. Arrangements at middle beam, section C-C along a joint between adjacent hollow core units, see Fig. 2. Rebars are made of steel A500HW.

Page 567: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

567

430

30

20

D D

180 18020

1100

50400

Fig. 8. Section D-D along hollow cores, see Fig. 2.

E E

Rebar d 20 L = 1050

50

150Cast-in-situconcrete

SlabSlab

H H

Rebar d 20 L = 1050

H H

Fig. 9. Tie reinforcement in the cast-in-situ concrete outside the longitudinal edge of the outermost slabs (section E-E in Fig. 2). See also App. A, Fig. 3. Rebars are made of steel A500HW.

Page 568: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

568

2.5 Slabs

45

R50

45

410205

R120

R125R50

500

1200

3520

Fig. 10. Nominal geometry of slab section. For more detailed data see Fig. 11.

Fig. 11. Nominal geometry of concrete section (in scale). (The number and position of strands were different in the present test, see Fig. 10.)

- Extruded by Parma Oy, Hyrylä factory 15.9.2005 - 16 lower strands J12,5 initial prestress 1050 MPa - No upper strands J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

Page 569: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

569

42,5

1161 (at mid-depth)

37,7

50,1

403,3206,3

500

64,5

bw,i

bw,i = 333,9

Fig. 12. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 1,7 in slab unit 8; 1,6 in slab unit 11; 1,5 in slab units 6, 8 and 11 Measured weight of slab units = 6,43 kN/m

2.6 Temporary supports

No

2.7 Loading arrangements

2P

+4,5 m

780220 420980180 1020 20

a 2Pa 2Pa 2Pa 2Pa 2PaX X

Fig. 13. Auxiliary loading frame, fixed to the floor of the hall by tension bars, six of which penetrated the hollow core floor.

Page 570: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

570

1000

100

0

Fig. 14. Auxiliary loading frame, plan.

P

P1

2

123

8

7200 (span of beam)

A A

B

C

4

60015

00 (

from

sla

b e

nd)

E

E

B

7200 (span of beam)

D C

2P

600600600600600600600600600600600 1000

0 (L

eng

th o

f sla

b)15

00

7200

D Ca

215

56

789101112

2Pa 2Pa 2Pa 2Pa 2Pa(span of beam)

Prim

ary

Tertiary Secondary

215

Sou

th

17485 17485 17485 174851748617486

17485 17485 17485 174851748617486

Nor

th

West

East

Fig. 15. Loading arrangements. Section X-X in Fig. 13. The slabs were from two casting lots: 17485 and 17486.

Page 571: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

571

A A

Load cells 2, 3 and 4 under support of beam

Det 1

2Pa

TertiarySecondary

Primary

7200

2Pa

2Pa

2Pa

2Pa

2Pa

Fig. 16. Section A-A. Pa refers to vertical actuator force.

Gypsum

Teflon plates

PSteel plate

FDet 1 F

F

F

L-profile

a Pa

Roller bar

Stiffening plates

Stiffening plates

Fig. 17. Detail 1, see previous figure. The stiffening plates are below the loads Pa.

3 Measurements

3.1 Support reactions

1

7

3 load cells

Fig. 18. Load cells below the Northern support of the middle beam.

Page 572: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

572

3.2 Vertical displacement

123

8

4

600

170

0

(fro

m s

lab

end)

E

E

600600600600600600600600600600600

1700

56

789101112

33343536

V

38 37 IV

111415 I17

VI

5355565759

464748495052 51

3940414243

VII

45 44

2526272829III

31 30

1819202122 II24 23

2600

2600

30 30 30 305050

215

215 32

13

30

So

uth

No

rth

Fig. 19. Location of transducers 11 … 45 for measuring vertical deflection along lines I … VII.

3.3 Average strain and 3.4 Horizontal. displacements

1234J

56

789101112

63 61

64

62

65

66

60 6030

215 215

215

150

150

G

G

67 (68)69 (70)

71 (72)73 (74)

75 (76)77 (78)

215

83 (84)

87 (88)

81 (82)

J

85 (86)

I I

Fig. 20. Position of device (transducers 67–78) measuring average strain parallel to the beams, position of transducers 61–66 measuring crack width and position of transducers 81–88 measuring measuring shear displacement of the slab ends. Numbers in parentheses refer to the soffit of the floor, others to the top.

Page 573: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

573

L

TransducerSteel bar

Fig. 21. Apparatus for measuring average strain. L = 1100 mm.

G G

70 74 78

385215215

69 7320 77

385

55050 5055020 20

20

Fig. 22. Section G-G along hollow cores.

I I

L-profile, glued to slab

L-profile, glued to slab83

84

J J

83

20

8720

88

2020

84

Fig. 23. Section I-I. Fig. 24. Section J-J.

3.5 Strain

Page 574: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

574

4 Special arrangements

None

5 Loading strategy

5.1 Load-time relationship

Date of the floor test was 11.11.2005 Before test all measuring devices were zero-balanced. The loading history is shown in Fig. 25. It comprised the following stages:

- Stage I: cyclic loading with three cycles up to Pa = 160 kN and back to zero - Stage II: monotonous loading close to failure followed by unloading which was

necessary due to the restricted stroke of the actuators - Stage III: after shimming of actuators, monotonous loading until failure. Pa = 160 kN corresponds to the shear force due to the expected service load when the shear resistance of the slab is supposed to be critical in the design.

Stages I, II and III

0

50

100

150

200

250

300

350

400

450

0 50 100 150 200 250 300 350

Time [min]

Pa [

kN]

I II III

Fig. 25. Actuator force Pa vs. time.

5.2 After failure

-

Page 575: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

575

6 Observations during loading

Before test No longitudinal cracks along the strands were discovered in the soffit of the slabs.

Stage I During stage I, the joint concrete gradually cracked along the webs of the middle beam. Here the first visible cracks were observed at Pa = 88 kN. At the same load new vertical cracks were also observed both in the Western and Eastern tie beam. The number of the new cracks in the tie beams increased with increasing load.

Stage II At Pa = 160 kN during stage II, the soffit of the slabs between the line loads and the middle beam was inspected visually. The observed visible cracks are shown in Fig. 26. They were all below the webs of the slabs. When increasing Pa beyond 160 kN, new vertical cracks appeared in the tie beams. At Pa = 334 kN an inclined crack was observed in slab 7 accompanied by a new inclined crack at Pa = 336 kN. At Pa = 337 kN an inclined crack, similar to the two shear cracks in slab 7, was observed in slab 1. Simultaneously, a sudden increase in the deflection, as well as a new vertical crack in the tie beam between slabs 4 and 5, were observed in the Western part of the test floor. Despite these shear cracks on opposite sides of the middle beam, the actuator loads could still be increased until the maximum stroke of the actuators was achieved at Pa = 379 kN. After this, short prefacricated steel tubes were placed close to the actuators to keep the floor in deflected position when unloading and shimming the actuators.

Stage III

After completing the shimming in stage III, the floor was reloaded. A new inclined crack in slab 1 resulting in shear failure was observed at Pa = 382,4 kN The cracks after the failure are shown in Fig. 28. The initial crack on the top surface of slab 9 did not contribute to the failure as can be concluded from the crack pattern.

After failure

When demolishing the test specimen it was observed that that the core fillings were perfect, see App. A, Fig. 22. Delta beam seemed to recover completely after the test. The slabs were placed directly on the bottom flange of the Delta beam. Due to the uneven surfaces of the slab soffit and the steel flange, there were thin gaps between the slab and the flange of the beam. When demolishing the floor it came out that these gaps were filled with grout (thicker gaps) or with cement paste (thinner gaps), see App. A, Fig. 23.

Page 576: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

576

7 Cracks in concrete

7.0 Cracks before test

123456

789101112

A

A

AA

A

A

A

A

AA

A

A A

AA A A A

A

A A

A

A

AA

AA

A AA

A

AA

A

A A

AAA A

A

Fig. 26. Initial cracks.

Page 577: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

577

7.1 Cracks at service load

123456

789101112

160160 160

160160

160160

A

A

AA

A

A

A

A

AA

160

160

88

88

12788

160156156

A

A A

AA A A A

A

A A

A

156

160 112

112 87156

112

160160A

AA

AA

A AA

A

AA

160 156

A

A A

AAA A

A

88

Fig. 27. Cracks at Pa = 160 kN. The dashed lines indicate thin ( 0,1 mm) cracks in the soffit.

Page 578: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

578

7.2 Cracks after failure

123456

789101112

So

uth

160160 160

160160

160160

A

A

AA

A

A

A

A

AA

160

195

275

196

160

88

88

12788

160156156

304

A

A A

AA A A A

A

A A

A

156

160

304

304250

304

112

112 87156

176 112

160160A

AA

AA

A AA

A

AA

160 156

A

A A

AAA A

A

382

337

336

334

351

330

349

88

349

263

No

rth

Fig. 28. Cracks until Pa = 160 kN in the soffit (dashed lines) and after failure on the top and at the edges of the slabs.

Page 579: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

579

8 Observed shear resistance

In Fig. 29 the reaction force Rp,obs at one end of the middle beam, measured by three load cells, vs. actuator load Pa is shown. The relationship is slightly nonlinear indicating some hysteresis in the cyclic stage.

0200400600800

100012001400160018002000

0 50 100 150 200 250 300 350 400

Pa [kN]

Rp

,ob

s [k

N]

Stages I & II

Stage III

Fig. 29. Measured reaction force Rp,obs at one end support of middle beam vs. actuator load Pa. Rp,obs includes only the reaction due to the actuator loads Pa. Figs 30 and 31 illustrate the ratio of measured support reaction Rp,obs to the theoretical support reaction Rp,th calculated from six actuator loads assuming simply supported slabs. Thus Rp,th is equal to (9900–1450)/9900x6xPa = 0,8535x6xPa. Before failure the maximum difference is -0,59%, i.e. Rp,th is less than 1% smaller than the measured support reaction. The assumption of simply supported slabs is accurate enough to justify the calculation of the experimental shear resistance based on it.

0,0

0,2

0,4

0,6

0,8

1,0

1,2

1,4

1,6

1,8

2,0

0 50 100 150 200 250 300 350 400

Pa [kN]

Rp,

obs

/Rp,

th

Stages I & II

Stage III

Fig. 30. Ratio of measured support reaction of the middle beam (Rp,obs) to theoretical support reaction (Rp,th) vs. actuator force Pa. Only actuator loads Pa are taken into account in the support reaction.

Page 580: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

580

0,0

0,2

0,4

0,6

0,8

1,0

1,2

0 50 100 150 200 250 300 350 400

Pa [kN]

Rp,

obs/

Rp

,th

Stage III

Fig. 31. As Fig. 27 but only stage III is shown. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pa, respectively. All components of the shear force are calculated assuming that the slabs behave as simply supported beams. For Veq and Vp this means that Veq = 0,8535xPe and Vp = 0,8535xPa. Vg,jc is calculated from the nominal geometry of the joints and density of the concrete, other components of the shear force are calculated from measured loads and weights. The values for the components of the shear force are given in Table 1. Table 1. Components of shear resistance due to different loads.

Shear force Action Load kN

Weight of slab unit 6,53 kN/m Vg,sl 32,19 Weight of joint concrete

0,39 kN/m Vg,jc 1,92

Loading equipment 6,22 kN Veq 5,33 Actuator loads 382,1 kN Vp 327,46

The observed shear resistance Vobs = 366,9 kN (shear force at support) is obtained for one slab unit and the shear force per unit width is vobs = 305,8 kN.

9 Material properties

9.1 Strength of steel:

ReH/Rp0,2 Rm

Component MPa MPa

Note

Delta beam 355 Nominal (S355J2G3)

Slab strands J12,5 1630 1860 Nominal (no yielding in test)

Reinforcement Txy (A500HW) 500 Nominal value for reinforcing bars (no yielding in test)

Page 581: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

581

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 15.11.2005 Upper flange of slab 1,

Mean strength [MPa] 70,5 (+4 d)1) vertically drilled, tested as

St.deviation [MPa] 3,32 drilled2), density = 2468 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 23.11.2005 Upper flange of slab 13,

Mean strength [MPa] 75,9 (+1-2 d)1) vertically drilled, tested as

St.deviation [MPa] 3,34 drilled2), density = 2463 kg/m3

9.4 Strength of cast-in-situ concrete

#

a

a

a

a mm

Date of test

Note

6 150 11.11.2005 Kept in laboratory in the same

Mean strength [MPa] 28,8 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,93 density = 2197 kg/m3

1) Date of material test minus date of structural test (floor test or reference test) 2) After drilling, kept in a closed plastic bag until compression

10 Measured displacements

In the following figures, VP stands for the shear force of one slab end due to imposed actuator loads, calculated assuming simply supported slabs.

10.1 Deflections

0

50

100

150

200

250

300

350

0 5 10 15 20 25

Deflection [mm]

Vp

[kN

]

1112141617

Fig. 32. Deflection on line I along Western end beam.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30 35 40

Deflection [mm]

Vp

[kN

]

18

1920

21

2223

24

Fig. 33. Deflection on line II in the middle of slabs 1–6.

Page 582: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

582

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30 35 40

Deflection [mm]

Vp

[kN

]25

26

2728

29

30

31

Fig. 34. Deflection on line III close to the line load, slabs 1–6.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

32

33

3435

36

3738

Fig. 35. Deflection on line IV along the middle beam.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30 35 40

Deflection [mm]

Vp [

kN]

39

40

41

42

43

44

45

Fig. 36. Deflection on line V close to the line load, slabs 7–12.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30 35 40

Deflection [mm]

Vp

[kN

]

46

47

48

49

50

51

52

Fig. 37. Deflection on line VI in the middle of slabs 7–12.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30

Deflection [mm]

Vp [k

N] 53

54

56

58

59

Fig. 38. Deflection on line VII along end beam, slabs 7–12.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30

Deflection [mm]

Vp

[kN

]

14, End

35, Delta

56, End

Fig. 39. Net deflection of midpoint of middle beam (35) and those of end beams (14, 56). Settlement of supports eliminated.

Page 583: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

583

10.2 Crack width

0

50

100

150

200

250

300

350

0,0 0,5 1,0 1,5 2,0 2,5

Differential displacement [mm]

Vp

[kN

]

61

62

63

64

65

66

Fig. 40. Differential displacement ( crack width) measured by transducers 61–66.

10.3 Average strain

Transducers 67–78 shown in Figs 20–22 measured the differential displacement between two points fixed to the test floor in order to determine the strains in beam’s direction. Figs 41–42 depict the results.

The differential displacement divided by the mutual distance of the two fixing points represents the average strain between those points. Assuming linear variation for the strain in vertical direction, the average strain at any depth between the measured top and bottom values can be calculated from the measured results. The average strain at the top and bottom fibre of the slabs and of the middle beam obtained in this way are shown in Figs 43–45 and in Figs 46–48 at service load and at failure load, respectively.

Assuming parabolic curvature due to the uniformly distributed load on the beam and having the span of the beam equal to 7,2 m, the maximum strain within each of the slabs 3, 4, 9 and 10 is 4% higher than the average strain measured between the edges of the slab. In this way, the maximum strain is obtained from the average strains by multiplying the latter by 1,04.

- On the top, the strains in the slabs were essentially smaller than those in the beam. This can be explained by the low transverse shear stiffness of the slabs. The scatter of the slab strains on the top was small.

- At the bottom, the strains in the slabs were also essentially smaller than those in the beam at the same level. The support reaction of the slabs was partly carried by the inclined webs of the middle beam. The interaction between the soffit of the slabs and the bottom flange of the beam was too weak to make the strains compatible. The tie reinforcement also tried to keep the transverse strain of the slab ends as small as possible. This can clearly be seen in Fig. 45. At Vp = 7 kN some kind of slippage took place

- At Vp = 137 kN the strain in the soffit of the slabs had a large scatter. At Vp = 326 kN the strain at the bottom of slab 9 was very small when compared with that of the other slabs. In slabs 3, 4 and 10 the scatter in the measured strains was relatively small. In slab 9, the strain at the bottom was much smaller than in the other slabs.

Page 584: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

584

0

50

100

150

200

250

300

350

-1,4 -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0

Differential displacement [mm]

Vp

[kN

]67

69

71 (beam)

73 (beam)

75

77

Fig. 41. Differential displacement at top surface of floor measured by transducers 67, 69, 71, 73, 75 and 77.

0

50

100

150

200

250

300

350

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4

Differential displacement [mm]

Vp [

kN]

68

70

72 (beam)

74 (beam)

76

78

Fig. 42. Differential displacement at soffit of floor measured by transducers 68, 70, 72, 74, 76 and 78.

0

50

100

150

200

250

300

350

-1,4 -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0,0

Average strain [mm/m]

Vp [

kN]

67

69

71 (beam)

73 (beam)

75

77

Fig. 43. Top fibre of floor. Average strain calculated from the differential displacements shown in Figs 41–42.

0

50

100

150

200

250

300

350

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4

Average strain [mm/m]

Vp [

kN]

68

70

72 (beam)

74 (beam)

76

78

Fig. 44. Bottom fibre of floor. Average strain calculated from the differential displacements shown in Figs 41–42.

0

2

4

6

8

10

12

14

16

18

20

0,00 0,01 0,02 0,03 0,04

Average strain [mm/m]

Vp [

kN]

68

70

72 (beam)

74 (beam)

76

78

Fig. 45 Bottom fibre of floor. Initial part of the previous figure.

0

100

200

300

400

500

600

-400 -200 0 200 400 600Strain [m/m]

De

pth

[mm

]

67-68 (Slab 3)69-70 (Slab 4)71-72 (Beam)73-74 (Beam)75-76 (Slab 9)77-78 (Slab 10)

Fig. 46. Average strain of slabs 3, 4, 9 and 10 as well as that of the middle beam at estimated service load Pa = 160 kN (Vp = 137 kN).

Page 585: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

585

0

100

200

300

400

500

600

-2000 -1000 0 1000 2000

Strain [m/m]

De

pth

[mm

]

67-68 (Slab 3)69-70 (Slab 4)71-72 (Beam)73-74 (Beam)75-76 (Slab 9)77-78 (Slab 10)

Fig. 47. Average strain of slabs 3, 4, 9 and 10 as well as that of the middle beam at failure load Pa =382 kN (Vp = 326 kN).

0

100

200

300

400

500

600

-2000 -1000 0 1000 2000Strain [m/m]

De

pth

[mm

]

Slabs 3, 4,9 & 10)

Beam

Fig. 48. Mean of average strains measured for slabs 3, 4, 9 and 10 as well as mean of average strains measured for the middle beam at failure load Pa = 382 kN (Vp = 326 kN).

10.4 Shear displacement

A positive value means that the slab is moving towards the end of the beam. The measured curves do not look logical, and there may have been some mess in numbering the transducers. There are two puzzles:

- why do the upper flange of slab 1 and lower flange of slab 7 in Fig. 49 move together and vice versa?

- why does the upper flange move less than the lower flange in Fig. 51 and partly in Fig. 49?

0

50

100

150

200

250

300

350

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6

Displacement [mm]

Vp

[kN

]

81 (slab 1)82 (slab 1)85 (slab 7)

86 (slab 7)

Fig. 49. North end of middle beam. Differential displacement between edge of slab and middle beam in beam's direction.

0

25

50

75

100

125

150

0,0 0,1 0,2 0,3 0,4

Displacement [mm]

Vp

[kN

]

81 (slab 1)

82 (slab 1)

85 (slab 7)

86 (slab 7)

Fig. 50. Same as previous figure, but only the initial part of the curves is shown.

Page 586: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

586

0

50

100

150

200

250

300

350

0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6

Displacement [mm]

Vp

[kN

]

83 (slab 6)

84 (slab 6)87 (slab 12)

88 (slab 12)

Fig. 51. South end of middle beam. Differential displacement between edge of slab and middle beam in beam's direction.

0

25

50

75

100

125

150

0,0 0,1 0,2 0,3 0,4

Displacement [mm]

Vp

[kN

]

83 (slab 6)

84 (slab 6)87 (slab 12)88 (slab 12)

Fig. 52. Same as previous figure, but only the initial part of the curves is shown.

10.5 Strain -

11 Reference tests

Slab 13 was taken from the same casting lot 17485 as four other slabs in the floor test.

5050

15002P

L

Gypsum

Neoprene Steel plate

50

1 (2)

3 (4)5 (6)

300

300

650

1

2

3

4

5

6

P

P

50

50

R R

R Ra

a

a

Fig. 53. Layout of reference tests. For L, see Table 3. Test R1 was carried out first.

Page 587: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

587

0

50

100

150

200

250

300

350

0 10 20 30 40 50

Time [min]

Pa

[k

N]

R1

R2

Fig. 54. Actuator force – time relationship. In both reference tests flexural cracks were observed below the loads before the shear tension failure took place in the webs close to the support. No visible slippage of the strands was observed before the failure. The failure modes are illustrated in Fig. 56 and in App. A, Figs 38–41.

The time dependence of the load and measured load – deflection relationship are shown in Figs 55.

Reference test R1

0

100

200

300

400

500

600

0 2 4 6 8 10 12 14 16 18 20

Displacement [mm]

Vp

[k

N] 123456

Reference test R2

0

100

200

300

400

500

600

0 2 4 6 8 10 12 14 16 18 20

Displacement [mm]

Vp

[k

N] 1

23456

Fig. 55. Vertical displecements measured by transducers 1–6. VP is the support reaction due to actuator forces Pa.

Page 588: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

588

300

300

650

P

Pa

aP

Pa

a

End 1 End 2

Fig. 56. Failure mode in tests R1 (End 1) and R2 (End 2). Table 2. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure, weight of loading equipment Peq, shear force Vp due to imposed load at failure, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span

mm

Vg

kN

Pa

kN

Peq

kN

Vobs

kN

vobs

kN/m Note

R1 21.12.2005 9900 32,1 278,5 0,29 507,8 396,4 Web shear failure

R2 22.12.2005 8420 28,1 315,0 0,29 550,9 435,7 Web shear failure

Mean 529,4 441,1

Page 589: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

589

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 366,9 kN per one slab unit or 305,8 kN/m. This is 69% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only

(deflection minus settlement of supports) was 25,7 mm or L/280, i.e. rather small. It was 2,4–2,6 mm greater than that of the end beams. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs.

2. The shear resistance measured in the reference tests was of the same order as the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against a web shear failure. VTT Research Notes 2292, Espoo 2005.

3. The observed shear resistance in the floor test was 69% of that in reference tests.

4. The edge slabs slided 0,6 … 1,4 mm along the beam before failure.This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance.

5. The failure mode was web shear failure of edge slabs. The Delta beam seemed to recover completely after the failure.

Page 590: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A590

APPENDIX A: PHOTOGRAPHS

Note: In Figs. 23–33 the cracks marked with red colour and letter A refer to initial cracks which existed before the onset of the loading.

Fig. 1. Delta beam as installed.

Fig. 2. Delta beam as installed.

Page 591: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A591

Fig. 3. Slab placed on Delta beam.

Fig. 4. Tie reinforcement at support of beam.

Page 592: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A592

Fig. 5. End of middle beam (Delta beam) after grouting.

Fig. 6. Overview on test arrangements.

Page 593: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A593

Fig. 7. Loading equipment.

Fig. 8. Longitudinal view on the loading equipment.

Page 594: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A594

Fig. 9. Actuators on the primary spreader beam and below the temporary loading frame.

Fig. 10. Arrangements at end beam.

Page 595: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A595

Fig. 11. Transducers at end of middle beam.

Fig. 12. Transducer, fixed to the bottom flange of the middle beam, measuring sliding of slab along beam.

Page 596: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A596

Fig. 13. Bottom flange of middle beam supporting slabs.

Fig. 14. Equipment for measuring average transverse strain of the soffit.

Page 597: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A597

Fig. 15. Initial crack in slab 3 close to end beam.

Fig. 16. Shear cracks in slab 7 at Pa = 336 kN.

Page 598: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A598

Fig. 17. Shear crack in slab 1 at Pa = 337 kN.

Fig. 18. Shear cracks in slab 1 after failure at Pa = 382 kN.

Page 599: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A599

Fig. 19. Shear cracks in slab 1 after removing the loading equipment.

Fig. 20. Failure pattern on the top of slab 1 after removing the loading equipment and drilling the cores.

Page 600: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A600

Fig. 21. Slab 1 after removing slabs 2–6 and 8–12.

Fig. 22. Perfect filling in a hollow core of slab 1.

Page 601: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A601

Fig. 23. Cast-in-situ concrete after removing the slabs. Note the grout layer between the slab and the flange of the beam.

Fig. 24. Western end beam. Cracks in cast in-situ concrete at the end of slabs 1 and 2.

Page 602: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A602

Fig. 25. Western end beam. Cracks in cast in-situ concrete at the end of slabs 1 and 2.

Fig. 26. Western end beam. Cracks in cast in-situ concrete at the end of slabs 2–4.

Page 603: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A603

Fig. 27. Western end beam. Cracks in cast in-situ concrete at the end of slabs 3–5.

Fig. 28. Western end beam. Cracks in cast in-situ concrete at the end of slabs 4–6.

Page 604: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A604

Fig. 29. Western end beam. Cracks in cast in-situ concrete at the end of slabs 5 and 6.

Fig. 30. Eastern end beam. Cracks in cast in-situ concrete at the end of slabs 7–9.

Page 605: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A605

Fig. 31. Eastern end beam. Cracks in cast in-situ concrete at the end of slabs 7–8.

Fig. 32. Eastern end beam. Cracks in cast in-situ concrete at the end of slabs 8–9.

Page 606: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A606

Fig. 33. Eastern end beam. Cracks in cast in-situ concrete at the end of slabs 9–11.

Fig. 34. Eastern end beam. Cracks in cast in-situ concrete at the end of slabs 10–12.

Page 607: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A607

Fig. 35. Eastern end beam. No crack in cast in-situ concrete at the end of slab 12.

Fig. 36. Arrangements in reference test R1.

Page 608: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A608

Fig. 37. Arrangements in reference test R1.

Fig. 38. Failure in reference test R1.

Page 609: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A609

Fig. 39. Failure in reference test R1.

Fig. 40. Failure in reference test R2.

Page 610: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

A610

‘ Fig. 41. Failure in reference test R2.

Page 611: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.Delta.500.2005

B611

APPENDIX B: DELTA BEAM

Fig. 1. Delta beam.

Page 612: Matti Pajari Prestressed hollow core slabs supported on beams ...
Page 613: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

613

1 General information

1.1 Identification and aim

VTT.PC.InvT.400.2006 Last update 2.11.2010

PC400U (Internal identification)

Aim of the test In test VTT.PC.InvT.400.1993 the edges of the beam were provided with square indents which, after grouting, served as dowels between the slab ends and the beam. In the present test the indents were missing and the longitudinal tie reinforcement was placed near to the mid-depth of the slabs. It was anticipated that these changes would enhance the shear resistance of the slabs.

1.2 Test type

Prestressed concrete beamHE 260A HE 260A

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 31.5.2006

1.4 Test report

Author(s) Pajari, M.

Name Load test on hollow core slab floor with prestressed concrete beam

Ref. number VTT-S-07331-06

Date 27.12.2006

Availability Available at www.rakennusteollisuus.fi

2 Test specimen and loading

Page 614: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

614

2.1 General plan

123

4800 (span of beam)

4

120

0 (f

rom

sla

b e

nd)

12009

000

(Len

gth

of s

lab)

4800 (span of beam)

240

240

4800 (span of beam)

5678

East

West

No

rth

120

01200 1200 1200

So

uth

900

0Line load

Line load

Fig. 2. Plan.

2.2 End beams

260

250

HE260A

7,512,5

12,5

Fig. 3. End beam made of steel.

400

50 50

HE260A

5050

Concrete K30

Rebars 2 d 12L = 4800

Plywood

Steel plate

Roller bar

60

60

Fig. 4. Arrangements at end beam.

Simply supported, span = 4,8 m, roller bearing below Northern end fy 355 MPa (nominal fy), did not yield in the test.

Page 615: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

615

2.3 Middle beam

- Cast by Parma Oy, 13.4.2006 - Simply supported, span = 4,8 m, roller bearing at both ends

1200120012001200200

5 holes d 60

5200

200

180

400200

P

P

Fig. 5. Middle beam. Elevation.

880

180

200 200

400

480

170

60

Chamfer 20x20

Fig. 6. Cross-sectional geometry.

49 48

96 66

48 48

48 74

48 48 48 49

48 66 96

484313

26J12,5

47 4J12,5

2 A1

Fig. 7. Main reinforcement.

Concrete: K80 J12,5: Prestressing strand =12,5 mm, Ap = 93 mm2, p0 = 1300 MPa, nominal strength fp0,2/fp = 1630/1860 MPa, did not yield in the test A1: Rebar A500HW, 12 mm, L = 5130 mm, nominal yield strength fy = 500 MPa, did not yield in the test

Page 616: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

616

Fig. 8. Middle beam.

Page 617: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

617

2.4 Arrangements at middle beam

18010

400

3 rebars d 16, L = 2800 one in each longitudinal joint of slabs

80

4 rebars d 12, L = 5200

60

170

880

180

200 200

Neoprene10x20

10

400

60480 506050

60 100 20

Plasticplug

Fig. 9. Section along joint between adjacent slab units.

Fig. 10. Section along hollow cores.

End of beam

Slab

GroutH

H

E

E H

E

880

180

200 200

10

400

60480 506050

60 100 20

H

80

80

E

Fig. 11. Cast-in-situ concrete (grout) outside hollow core slabs.

Fig. 12. Section E-E, see Fig. 11.

10060

H H

Slab Slab50 (width on the top)

150

Hole through beam

Cast-in-situconcrete

Rebar d 16, L = 800

Fig. 13. Section H-H, see Fig. 11.

Tie reinforcement: Straight horizontal rebars A500HW through the beam and parallel to the beam, nominal yield strength fy = 500 MPa

Page 618: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

618

1234

5678

Rebars 3 d 16 L = 2800

Rebar 1 d 16 L = 800

Rebars 1 + 1 d 12 L = 5200

Rebars 1 + 1 d 12 L = 5200

Rebar 1 d 16 L = 800

Fig. 14. Overview on tie reinforcement at middle beam. d xy refers to a reinforcing bar A500HW with diameter xy mm. For the vertical position of the bars, see Figs 9 and 12.

2.5 Slabs

1200

65

R135

90 65

220

45o

40

40

400

36

30

Fig. 15. Nominal geometry of slab units (in scale).

- Extruded by Parma Oy, Hyrylä factory 16.3.2006

- Measured weight = 5,65 kN/m

bw,i = 324,3

61,467,2

39,7

20,2

1164 (at mid-depth)

36,8

53,9

67,267,2397

61,4

Fig. 16. Most relevant measured geometrical properties.

Max measured bond slippage: 3x2,0 mm (in slabs 1, 3 and 6; 3x1,9 mm (in slabs 1, 4 and 7)

Page 619: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

619

2.6 Temporary supports

No

2.7 Loading arrangements

P2

A A

600

1200

(fr

om s

lab

end

)

E

600600600600600600600

1200

4800 (span of beam)48

0

Pa1

2Pa2 2Pa2 No

rth

So

uth

Pa1

Pa1 Pa1

6060

Fig. 17. Plan. Pa1 and Pa2 refer to vertical actuator forces.

Load cells 3, 4 and 5 under support of beam

Det 1

2Pa2

2Pa12Pa1

A A

Tertiary

Secondary

Primary 2Pa2

Fig. 18. Section A-A, see Fig. 17.

Gypsum

Teflon plates

PSteel plateF

Det 1F

F

F

L-profile

a2 Pa2

Roller bar

Stiffening plates

Stiffening plates

550550

600

F

Fig. 19. Detail 1, see previous figure.

Page 620: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

620

3 Measurements

3.1 Support reactions

1

5

3 load cells

No

rth

Fig. 20. Load cells below the Northern support of the middle beam.

3.2 Vertical displacement

1234

140

0

(fro

m s

lab

end)

E

E

140056

2627282930

V

IV

1114 I15

VI

414445

3637383940

3132333435

VII

2122232425III

1617181920 II

2500

2500

30 30 3050

50

240

12

30

13

30

4243

240

8 7

So

uth

No

rth

Fig. 21. Location of transducer 11 … 45 for measuring vertical deflection along lines I … VII.

Page 621: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

621

3.3 Average strain 1234

5678

240

240

200

200

G

G

57 (58)59 (60)

61 (62)63 (64)

65 (66)67 (68)

60

60

No

rth

So

uth

Fig. 22. Position of device (transducers 57–68) measuring average strain parallel to the beams.

L

TransducerSteel bar

Fig. 23. Apparatus for measuring average strain. L =1100 mm.

60

G G

200240240

59 63

68

20 67

602064

60440 440

2064

Fig. 24. Section G-G, see Fig. 22.

3.4 Horizontal. displacements

1234J

53 51

5456

60 60240

240

73 (74)

77 (78)

71 (72)

J

75 (76)

H H 52

55

30

5678

Fig. 25. Transducers measuring crack width (51–56) and shear displacement at the ends of the middle beam (71–78). Transducers 72, 74, 76 and 78 are below transducers 71, 73, 75 and 77, respectively.

Page 622: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

622

H H

L-profile, glued to slab73

L-profile, glued to slab

74

Fig. 26. Section H-H, see Fig. 25.

J J

78

73

74

77

2020

220

20

Fig. 27. Section J-J, see Fig. 25.

4 Special arrangements

- None

5 Loading strategy

5.1 Load-time relationship

0

50

100

150

200

250

300

0 20 40 60 80 100 120 140 160

Time [min]

Pa

i [kN

]

Pa1

Pa2

Stage I Stage II

Fig. 28. Actuator forces Pa1 and Pa2 vs. time. Date of test 31.5.2006

5.2 After failure

-

Page 623: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

623

6 Observations during loading

Before loading All measuring devices were zero-balanced when the actuator forces Pai were equal to zero but the weight of the loading equipment was on. The loading history is shown in Fig. 28. Pai = 125 kN corresponds to the shear force due to the expected service load when the shear resistance of the slabs is supposed to be prevailing in the design.

Stage I The joint concrete gradually cracked along the webs of the middle beam on the Eastern side (slabs 5–8). Here the first visible cracks were observed at Pa1 = 38 kN. On the opposite (Eastern) side of the middle beam, a similar crack was observed at Pa1 = 70 kN.

Pa1 = 125 kN during stage II

The soffit of the slabs between the line loads and the middle beam was inspected visually. The observed two visible cracks are shown in Fig. 29. They were both below the webs of the slabs.

Pa1 = 189 – 200 kN New vertical cracks were observed both in the Western

and Eastern tie beam. Both the number and the length of the cracks in the tie beams (= concrete connecting the slab ends above the supporting end beams, see Fig. 30) increased with increasing load.

Pa1 = 295,1 kN and Pa2 = 292,2 kN

The floor suddenly failed in shear on the Eastern side of the middle beam, see App., Figs 12–14 and 20–23. In slabs 5–8 an inclined crack appeared between the middle beam and the line load so rapidly that it was impossible to say, which slab failed first. The cracks after the failure are shown in Fig. 30. The joint between the grout and middle beam cracked neatly along the smooth edges of the middle beam as shown in App. A, Figs 24 an 25.

Page 624: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

624

7 Cracks in concrete

7.1 Cracks at service load

1234

5678

A

125

125

AAA

A

AAAA

3870

So

uth

No

rth

Fig. 29. Cracks at service load (Pai = 125 kN). The initial cracks observed before loading are indicated with red colour and letter A. A dashed line indicates a crack in the soffit. The figures give the value of the actuator force at which the crack (other than initial crack) was observed.

Page 625: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

625

7.2 Cracks after failure

1234

5678

A29

6

220

125

125

200AAA

A

A190

190 250

189A

220206

190A

200

A

206206

200

200221208200

220

296

296296

296

296

296

3870

So

uth

No

rth

Fig. 30. Cracks after failure. The initial cracks are indicated with red colour and letter A. A dashed line indicates a crack in the soffit. The figures give the value of the actuator force at which the crack was observed.

Page 626: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

626

8 Observed shear resistance

The ratio (measured support reaction below one end of the middle beam) / (load on half floor) is shown in Fig. 31.

0,800

0,810

0,820

0,830

0,840

0,850

0,860

0,870

0,880

0,890

0,900

0 50 100 150 200 250 300

Pa2 [kN]

Rp

,ob

s/

Fai

Fig. 31. Ratio of measured support reaction of the middle beam (Rp,obs) to load on half floor vs. actuator force Pa2. Only actuator loads Pai are taken into account in the support reaction. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pai, respectively. The components of the shear force due to the self-weight are calculated assuming that the slabs behave as simply supported beams. For Veq and Vp the relation is Veq = 0,8619xPe and Vp = 0,8619x(Pa1.+ Pa2)/2 at failure. Vg,jc is calculated from the nominal geometry of the joints and density of the concrete, other components of the shear force are calculated from measured loads and weights. The values for the components of the shear force are given in Table below. Table. Components of shear resistance due to different loads.

Action Load Shear force kN

Weight of slab unit 5,65 kN/m 25,00

Weight of joint concrete 0,302 kN/m 1,34

Loading equipment (0,66+6,22)/2 kN 2,96

Actuator loads (295,1+292,2)/2 kN 253,10 The observed shear resistance Vobs = 282,4 kN (shear force at support) is obtained for one slab unit wit width = 1,2 m. The shear force per unit width is 235,3 kN/m.

Page 627: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

627

9 Material properties

9.1 Strength of steel

Component ReH/Rp0,2 Rm Note MPa MPa End beam 350 Nominal (no yielding)

Slab strands 1630 1860 Nominal (no yielding) Beam strands 1630 1860 Nominal (no yielding) Reinforcement 500 Nominal (A500HW,no yielding)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 1.6.2006 Upper flange of slab 5,

Mean strength [MPa] 55,3 (+1 d)1) vertically drilled, tested as

St.deviation [MPa] 1,33 drilled2), density = 2386 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

From

6 50 50 9.6.2006 Upper flange of slab 9,

Mean strength [MPa] 58,9 (+1 d)1) vertically drilled, tested as

St.deviation [MPa] 0,87 drilled2), density = 2387 kg/m3

9.4 Strength of grout

#

a

a

a

a mm

Date of test

Note

6 150 31.5.2006 Kept in laboratory in the same

Mean strength [MPa] 33,7 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,37 density = 2196 kg/m3

9.5 Strength of beam concrete

#

Cores h

d

h mm

d mm

Date of test

From

6 100 100 1.6.2006 Upper part, vertically drilled

Mean strength [MPa] 72,0 (+1 d)1) Tested as drilled2)

St.deviation [MPa] 1,84 2378 Density = 2378 kg/m3 1) Date of material test minus date of test (floor test or reference test)

2) kept in a closed plastic bag after drilling until compression

Page 628: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

628

10 Measured displacements

In the following figures, Vp stands for the shear force of one slab end due to imposed actuator loads, calculated assuming simply supported slabs.

10.1 Deflections

0

50

100

150

200

250

300

0 1 2 3 4 5 6

Deflection [mm]

Vp

[kN

]

1112

131415

Fig. 32. Deflection on line I along western end beam vs. support reaction Vp of one slab due to actuator loads.

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14 16

Deflection [mm]

Vp

[kN

]

1617181920

Fig. 33. Deflection on line II in the middle of slabs 1–4.

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14

Deflection [mm]

Vp

[kN

]

2122232425

Fig. 34. Deflection on line III close to the line load, slabs 1–4.

0

50

100

150

200

250

300

0 1 2 3 4 5 6 7 8

Deflection [mm]

Vp

[kN

]

2627282930

Fig. 35. Deflection on line IV along the middle beam.

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14

Deflection [mm]

Vp

[kN

]

3132333435

Fig. 36. Deflection on line V close to the line load, slabs 5–8.

0

50

100

150

200

250

300

0 2 4 6 8 10 12 14 16 18

Deflection [mm]

Vp

[kN

]

3637383940

Fig. 37. Deflection on line VI in the middle of slabs 5–8.

Page 629: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

629

0

50

100

150

200

250

300

0 1 2 3 4 5 6

Deflection [mm]

Vp [k

N]

41

42

43

44

45

Fig. 38. Deflection on line VII along end beam, slabs 5–8.

0

50

100

150

200

250

300

0 1 2 3 4 5 6 7

Net deflection [mm]

Vp [k

N]

13

28

43

Fig. 39. Net deflection of midpoint of middle beam (28) and those of end beams (13, 43).

10.2 Crack width

Fig. 40. Differential displacement parallel to the slab between the middle beam and the slabs (≈ crack width). See Fig. 25 for the location of the transducers. Transducer 56 has given erroneus results because the crack width equal to 2,0 mm was not visually observed during the cyclic stage

0

50

100

150

200

250

300

0,0 0,5 1,0 1,5 2,0 2,5 3,0

Differential displacement [mm]

Vp

[kN

]

51

52

53

54

55

56

10.3 Average strain

0

50

100

150

200

250

300

-1,0 -0,8 -0,6 -0,4 -0,2 0,0

Differential displacement [mm]

Vp

[kN

] 57

59

61 beam

63 beam

65

67

Fig. 41. Differential displacement at top surface of floor measured by transducers 57, 59, 61, 63, 65 and 67.

0

50

100

150

200

250

300

0,0 0,2 0,4 0,6 0,8 1,0

Differential displacement [mm]

Vp

[kN

] 58

60

62 beam

64 beam

66

68

Fig. 42. Differential displacement at soffit of floor measured by transducers 58, 60, 62, 64, 66 and 68.

Page 630: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

630

10.4 Shear displacement

0

50

100

150

200

250

300

-0,2 0,0 0,2 0,4 0,6 0,8 1,0

Differential displacement [mm]

Vp [k

N]

71 Slab1

72 Slab 1

73 Slab 4

74 Slab 4

Fig. 43. Northern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

0

50

100

150

200

250

300

-0,2 0,0 0,2 0,4 0,6 0,8 1,0

Differential displacement [mm]

Vp

[kN

]

75 Slab 5

76 Slab 5

77 Slab 8

78 Slab 8

Fig. 44. Southern end of middle beam. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam.

11 Reference tests

5050

12002P

L

Gypsum

Neoprene Steel plate

50

4 (3)

5 (2)6 (1)

300

300

650

123

4 5 6

P

P

50

50

R R

R Ra

a

a

200

Fig. 45. Layout of reference test. For L, see the next table.

Page 631: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

631

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25

Time [min]

Pa

[kN

]

R1

0

20

40

60

80

100

120

140

160

180

200

0 5 10 15 20 25

Time [min]

Pa

[kN

]

R2

Fig. 46. Tests R1 and R2. Actuator force – time relationship.

0

50

100

150

200

250

300

350

-2 0 2 4 6 8 10

Deflection [mm]

Vp

[kN

]

123456

R1

0

50

100

150

200

250

300

350

-2 0 2 4 6 8

Deflection [mm]

Vp

[kN

] 1

23

456

R2

Fig. 47. Tests R1 and R2. Displacements measured by transducers 1–6. Vp is the shear force due to the actuator force Pa. Table. Span of slab, shear force Vg at support due to self weight of slab, actuator force Pa at failure, weight of loading equipment Peq, shear force Vp due to imposed load at failure, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

Pa kN

Peq kN

Vp kN

Vobs kN

vobs kN/m

R1 June 9, 2006 8894 25,2 173,9 0,29 303,1 328,3 273,6

R2 June 9, 2006 7700 21,9 185,1 0,29 315,2 337,0 280,9

Mean 332,7 277,2

Page 632: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

632

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 282,4 kN per one slab unit or 235,3 kN/m. This is 85% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator load

(deflection minus settlement of supports) was 6,2 mm or L/774, i.e. very small

2. The shear resistance measured in the reference tests was a bit lower than the mean of observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

3. The torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs because the maximum difference in the net mid-point deflection was less than 1,3 mm

4. The bond between the smooth edges of the middle beam and the grout was weak.

5. The bond between the soffit of the slab and the grout below it was also weak.

6. The position of the tie reinforcement 170 mm above the slab soffit was favourable.

7. Due to the weak bond and position of the tie reinforcement, the edge slabs did slide 0,17 … 0,21 mm along the beam before failure, see Figs 43 and 44. This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance

8. The transverse shear deformation of the edge slabs was considerable which can be seen from the relative displacement between the top flange and bottom flange, see Figs 43 and 44. At failure, the transverse horizontal displacement of the top flange was 0,52 … 0,67 mm greater than that of the bottom flange

9. The observed shear resistance was considerably higher than that in previous test VTT.PC.InvT.400.1993. This can be explained by the improvements in the middle beam, i.e. by elimination of indents at the edges of the beam and by the higher position of longitudinal reinforcement.

Page 633: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

A633

APPENDIX A: PHOTOGRAPHS

Fig. 1. Slab installed on middle beam.

Fig. 2. Middle beam.

Fig. 3. Reinforcement at the end of middle beam. One rebar parallel to the beam on the top of the joint is still missing.

Fig. 4. Reinforcement at the end of middle beam. One rebar parallel to the beam on the top of the joint is still missing.

Fig. 5. Loading arrangements.

Fig. 6. Transducers measuring deflection and differential horizontal displacement in the middle of the test floor.

Page 634: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

A634

Fig. 7. Transducers measuring differential horizontal displacement at one end of the middle beam.

Fig. 8. Loading of slabs 2 and 6 with two actuators

Fig. 9. Loading arrangements.

Fig. 10. Transducers at one end of middle beam

Fig. 11. An overview on test arrangements.

Fig. 12. Failure of slab 5.

Page 635: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

A635

Fig. 13. Failure of slab 8.

Fig. 14. Soffit of slabs 5–8 after failure.

Fig. 15. Cracks in Western tie beam after failure. Slabs 1–3.

Fig. 16. Cracks in Western tie beam after failure. Slabs 2–4.

Fig. 17. Cracks in Western tie beam after failure. Slabs 3–4.

Fig. 18. Cracks in Eastern tie beam after failure. Slabs 5–7.

Page 636: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

A636

Fig. 19. Cracks in Eastern tie beam after failure. Slabs 7–8.

Fig. 20. Failure in slab 5.

Fig. 21. Failure in slabs 5–7.

Fig. 22. Failure in slabs 6–8.

Fig. 23. Failed ends of slabs 5–8.

Fig. 24. Western side of middle beam. Note the failure of the bond along the vertical interface of the cast-in-situ concrete and the precast beam as well as the perfect filling of the gap below the slab end.

Page 637: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

A637

Fig. 25. Western side of middle beam.

Fig. 26. Eastern side of middle beam.

Fig. 27. Overview on arrangements in reference tests. The actuators in the rear were not used.

Fig. 28. Reference test R1. Northern side of slab after failure.

Fig. 29. Reference test R1. Southern side of slab after failure.

Fig. 30. Reference test R2. Northern side of slab after failure.

Page 638: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.PC.InvT.400.2006

A638

Fig. 31. Reference test R2. Southern side of slab after failure.

Page 639: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

639

1 General information

1.1 Identification and aim

VTT.CR.A-beam.320.2006 Last update 2.11.2010

A320 (Internal identification)

Aim of the test To quantify the interaction between the A-beam and hollow core slabs.

1.2 Test type

A-beamHE200A HE200A

Fig. 1. Illustration of test setup.

1.3 Laboratory & date of test

VTT/FI 17.11.2006

1.4 Test report

Author(s) Pajari, M.

Name Load test on hollow core slab floor with A-beam

Ref. number RTE868/02

Date 15.3.2007

Availability Confidential, owner is Anstar Oy, Erstantie 2, FI-15540 Villähde, Finland

www.anstar.fi

2 Test specimen and loading (see also Appendices A and B)

Page 640: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

640

2.1 General plan

4800 (span of beam)

123

4800 (span of beam)B

DC

4

120040

E

E

305

B

4800 (span of beam)

305

7

DC

6 5815

00

In-situ concrete K30

WEST

NORTHSOUTH

8000

1250

(fro

m s

lab

end)

(fro

m s

lab

end)

1200 1200 1200

Fig. 2. Plan. Position of line loads shown in blue color.

2.2 End beams

50

Plywood

Plastic plug

L=4800

200

190End beamHE 200 A

6,5

50

Steel plate

B B

Concrete K30

Steel rod,free to roll

2 8

10

50 50

10

Tie beam

Fig. 3. Arrangements at end beam. 8 refers to a reinforcing bar TW8, see 2.3.

Page 641: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

641

Simply supported, span = 4,8 m fy 355 MPa (nominal fy), did not yield in the test.

2.3 Middle beam

The beam, see Figs 4–9 and App. A, comprised

- a prefabricated steel box girder with perforated top plate and lontitudinal rebars welded onto the top plate

- a precast concrete component which filled the box girder - a cast-in-situ concrete component on the top of the box girder - The precast concrete cast by Anstar Oy - Upper part cast by VTT in laboratory together with the joint grouting, 6.11.2006 Concrete: K40 in the prefabricated part, K30 in the upper part A-BEAM:

End plates: Raex 460 M ( nominal fy 460 MPa) Other structural steel: S355J2G3, fy 355 MPa (nominal fy) Passive reinforcement in A-beam:

Txy: Hot rolled, weldable rebar A500HW, = xy mm Tie reinforcement:

Txy: Hot rolled, weldable rebar A500HW, = xy mm, see Figs 4–8.

Fig. 4. A-beam when one slab element has been installed.

Page 642: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

642

Fig. 5. Illustration of steel component of middle beam. End plates and hoop reinforcement not shown.

1200 120012001200200 200

5200

10 Five holes 52x72 mm2T

Camber 0,0 mm

Steel S355

U

U T

Fig. 6. A-beam. Elevation.

110 580 110

800

490

10

245

8

60

7045

Steel tube4x60x80

4 rebars d 32

3 rebars d 32

Rebar d 40

8130

Hoops d 6

T T

c/c 200

Fig. 7. A-beam. Section T-T. d xy refers to rebars Txy.

Page 643: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

643

270

U U

600

End plate500

Rebars welded to end plate

Fig. 8. A-beam. Section U-U.

135

190 200 200

Fig. 9. A-beam. Holes in the top flange.

Page 644: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

644

2.4 Arrangements at middle beam

- Simply supported, span = 4,8 m, roller bearing at North end

800951595 15 10

320275

Rebars 2 d 10 L = 5200

500

210

1460

60o

1460

210

Suspension reinforcement d 16

Tie reinforcement d 12

D D

Fig. 10. Arrangements at middle beam, section D-D along a joint between adjacent hollow core units in Fig. 2. The suspension reinforcement along the edges of the floor was similar to that shown here but the length of the tails was 1260 mm instead of 1460 mm. d xy refers to rebar Txy, see 2.3.

800951595 15 10

320

C C50

Fig. 11. Section C-C along hollow cores in Fig. 2.

Page 645: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

645

1234

5678

Rebars 3 d 12 L = 3000

Rebars 1 + 1 d 10 L = 5200

Rebars 1 + 1 d 10 L = 5200

Rebar 1 d 8 L = 2400Rebar 1 d 8 L = 2400

Fig. 12. Overview on tie reinforcement at middle beam. d xy refers to a reinforcing bar Txy, see 2.3.

1234

5678

Rebars 3 d 16 L = 4000

Rebar 1 d 12 L = 3600 Rebar 1 d 12 L =3600

Fig. 13. Overview on suspension reinforcement at middle beam. d xy refers to a reinforcing bar Txy, see 2.3.

Page 646: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

646

2.5 Slabs

320

1200

114,5111,5

R126

41 3535

71

35

R126

R126

229

R126

35

1158

Fig. 14. Illustration of nominal slab cross-section drawn in scale. Concrete K60. - Extruded by Parma , Hyrylä factory 6.10.2006 - 13 lower strands J12,5 initial prestress 1000 MPa J12,5: seven indented wires, =12,5 mm, Ap = 93 mm2

43,143,1

33,5

1162 (at mid-depth)

33,5

238,9238,9

38,0 73,4

bw,i

bw,i

= 256,0

Fig. 15. Mean of most relevant measured geometrical characteristics.

Max measured bond slips: 1,9 and 1,6 mm in slab unit 6, 2x1,4 mm in slab unit 8 Measured weight of slab units = 4,62 kN/m

2.6 Temporary supports

No

Page 647: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

647

2.7 Loading arrangements

8000

4800 (span of beam)

PP

1250(from slab end)

2 2

123

4800 (span of beam)

P1

B

DC

4

300 300 300

300

300

300300300

40

E

E

600

305

B

4800 (span of beam)

305

P2

7

DC

P2

6 5 A8A

P P1 1

1500

In-situ concrete K30

P1

600 600 600

WEST

NORTH

EAST

SOUTH

Fig. 16. Plan. P1 =Pa1 and P2 =Pa2 refer to vertical actuator forces.

P P P 2P P P2 2 21 1 1 1

A A

Load cells 2, 3 and 4 under support of beam

Det 1

Fig. 17. Section A-A, see Fig. 17.

Page 648: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

648

Gypsum

Teflon plates

P Steel platesFDet 1

1F

550F

F

Fig. 18. Detail 1, see Fig. 18.

3 Measurements

3.1 Support reactions

1

5

3 load cells

No

rth

Fig. 19. Load cells below the Northern support of the middle beam.

Page 649: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

649

3.2 Vertical displacement

305

123

5678

4

3500

(fr

om

sla

b en

d)

1617181920

3132333435

4500

2627282930

4647484950

30 30 30 30 30

20 20 202020

610

VIII

305

1112131415

50 5030 30 30 30 30

1400

51525355 IX54

Inductive transducer for measuring vertical displacement- Transducers 32, 33, 34 on the continued centrelines of the longitudinal joints between the slabs - Transverse measures given with respect to the centrelines of the joints between the slabs

50 50 50

30 30 30 30 30

1400

2122232425

37383940VI

III

II

I

IV

V

36

41424345 VII44

2100

30 3030 30 30

4500

Fig. 20. Location and numbering of transducers 11–55 for measuring vertical displacement at lines I–IX.

Page 650: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

650

3.3 Average strain

5678

65 (75)1234

L

L

2040

440

440

64 (74)

66 (76)67 (77)

69 (79) 68 (78)

L

L

20

2066

74

64

76

68

78 Fig. 21. Transducers measuring average strain in beam’s direction. Numbers in parentheses refer to transducers below the floor.

L

TransducerSteel bar

Fig. 22. Apparatus for measuring average strain. L =1100mm.

3.4 Horizontal. displacements

5678 60(61)

1234

5

810

Measures differential displacement between slab edge and beam in beam's direction

7 6

9

40 40 40

Measures differential displacement between slab end and beam (crack width)

H H62

(63)

58(59)

56(57)

Middle beam

13020

13020

South North

Fig. 23. Transducers measuring crack width (5–10) and shear displacement at the ends of the middle beam (56–63). Transducers 57, 59, 61 and 63 are below transducers 56, 58, 60 and 62, respectively.

Page 651: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

651

J60

H H

J

L-profile, glued to slab

61

Fig. 24. Section H-H, see Fig. 24.

60

61

56

J J

20

20

57

30 (from slab end)

Fig. 25. Section J-J, see Fig. 25.

3.5 Strain

-

4 Special arrangements

-

5 Loading strategy

5.1 Load-time relationship

Date of test was 17.11.2006 Before loading all measuring devices were zero-balanced. The loading history is shown in Fig. 27.

0

40

80

120

160

200

0 40 80 120 160 200

Time [min]

Pai [k

N]

Pa1

Pa2

Stage I Stage II

Fig. 26. Actuator forces Pa1 and Pa2 vs. time.

Page 652: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

652

0

100

200

300

400

500

600

700

0 100 200 300 400 500 600 700 800

2(Pa1+Pa2) [kN]

Rp,

obs

[kN

]

Fig. 27. Development of support reaction R below Northern end of middle beam as function of actuator loads 2(Pa1 + Pa2) on half floor.

5.2 After failure

-

6 Observations during loading

Before test The soffit of the slabs next to the middle beam was visually inspected and some cracks along the strands were observed, see Fig. 29.

Stage I The joint concrete at the middle beam gradually cracked along the ends of slabs 5–8. The first visible cracks were observed at Pa2 = 38 kN. On the opposite (Western) side of the middle beam, a similar crack was observed at Pa2 = 70 kN. The first flexural cracks in the tie beams above the end beams appeared at Pa2 = 61 kN. Their number and length increased with increasing load, see Figs 29 and 30.

Stage II At Pa2 = 70 kN, the soffit of the slabs between the line loads and the middle beam was again inspected visually. The observed visible cracks are shown in Fig. 29. Most of them were below the webs with four strands, i.e. below the strands, but none below the midmost or outermost webs where the number of strands was only three or one per web, respectively, see. Fig. 14. With increasing load new inclined cracks gradually appeared in the cast-in-situ concrete at the outermost edges of the slabs next to the ends of the middle beam, see Fig. 30. Before failure there were such cracks in the corners of slabs 1, 4, 5 and 8. In slab 8 the cracks were particularly wide before failure as can be seen in App. B, Fig. 23. The tie beams at the ends of the floor also cracked in flexure. The first flexural cracks appeared in the middle of the beams at Pa2 = 61 kN, i.e. during the cyclic load stage. Thereafter, the Eastern tie beam proved to be much stronger against cracking than the Western one. The Eastern tie beam was uncracked next to the joint between slabs 7 and 8 until failure. No reason for this nonsymmetrical behaviour could be detected.

Page 653: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

653

The failure mode was web shear failure in slabs 8 and 7, see Fig. 30 and App. B, Figs 26, 27, 36 and 39–42.

After failure When demolishing the test specimen it was observed that the core fillings were perfect. The slabs were placed on the ledge of the middle beam without any intermediate material. Due to the curved soffit of the slabs and uneven top surface of the ledge, small gaps remained somewhere between the soffit of the slab units and the underlying ledge of the middle beam, see e.g. App. B, Fig. 17. After demolishing the floor it was observed that cement paste or grout had gone into these gaps thus making the supporting ledge more even and able to distribute the support reaction to all webs. This is illustrated in App. B, Figs 43 and 44. When demolishing the floor it was observed that at the middle beam the cast-in-situ concrete had cracked vertically along the slab ends. This is illustrated in App. B, Figs 40–42.

7 Cracks in concrete

7.1 Cracks at service load

1234

7 6 58

0000

00

7070

707070

70707070

000 7070

70

70

70

00000007161

61

7070

70

3838

00 0

Fig. 28. Cracks at service load (Pai ≈ 70 kN). The initial cracks are indicated with red colour. A dashed line indicates a crack in the soffit. The figures give the value of the actuator force at which the crack was observed.

Page 654: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

654

7.2 Cracks after failure

1234

7 6 58

0000

00

7070

707070

70707070

000 7070

70

70

70

0000

130

000

177

140185

807161190

61

145125 120

130

7070

70

38

140175 145

155165

100105 38

145155

170175

185

100

115

175

185

80

145

165

175170

00

190

0

Fig. 29. Cracking pattern after the failure. The dashed lines illustrate the cracks in the soffit.

8 Observed shear resistance

The ratio (measured support reaction below one end of the middle beam)/ (theoretical support reaction due to actuator forces on half floor) is shown in Fig. 31. The theoretical reaction is calculated assuming simply supported slabs. This comparison shows that the support reaction due to the actuator forces can be calculated accurately enough assuming simply supported slabs. However, the failure of the slab ends at the North end of the middle beam resulted in reduction of support reaction below that end while the actuator force could still slightly be increased. The maximum support reaction is regarded as the indicator of failure.

Page 655: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

655

0,0

0,2

0,4

0,6

0,8

1,0

1,2

1,4

1,6

0 100 200 300 400 500 600 700 800

2(Pa1+Pa2) [kN]

Rp,

obs

/ Rp,

th

Fig. 30. Ratio of measured support reaction of the middle beam (Rp,obs) to theoretical support reaction (Rp,th) vs. actuator forces on half floor. The theoretical support reaction Rp,th is calculated from four actuator loads assuming simply supported slabs. Thus Rp,th is equal to (7900–1200)/7900x4xPam = 0,8481x4xPam. where Pam = (Pa1 + Pa2)/2. Before failure the assumption of simply supported slabs is accurate enough to justify the calculation of the experimental shear resistance based on it. The shear resistance of one slab end (support reaction of slab end at failure) due to different load components is given by

Vobs = Vg,sl + Vg,jc + Veq + Vp (1)

where Vg,sl, Vg,jc, Veq and Vp are shear forces due to the self-weight of slab unit, weight of joint concrete, weight of loading equipment and actuator forces Pai, respectively. All components of the shear force are calculated assuming that the slabs behave as simply supported beams. For Veq and Vp this means that Veq = 0,8481xPe and Vp = 0,8481x(Pa1.+ Pa2)/2. Vg,jc is calculated from the nominal geometry of the joints and density of the concrete, other components of the shear force are calculated from measured loads and weights. The values for the components of the shear force are given in Table 1. Table 1. Components of shear resistance due to different loads.

Action Load Shear force kN

Weight of slab unit 4,62 kN/m 18,25

Weight of joint concrete

0,24 kN/m 0,95

Loading equipment (0,66+5,70)/2 kN 2,70

Actuator loads (190,6+190,1)/2 kN 161,44 The observed shear resistance Vobs = 183,3 kN (shear force at support) is obtained for one slab unit. The shear force per unit width is vobs = 152,8 kN/m

Page 656: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

656

9 Material properties

9.1 Strength of steel

ReH/Rp0,2 Rm

Component MPa MPa

Note

A-Beam - End plates - Other structural steel

460 355

Nominal Raex 460 Nominal (S355J2G3)

End beams 355 (HEA 120)

Slab strands J12,5 1630 1860 Nominal (no yielding in test)

Reinforcement Txy 500 Nominal value for reinforcing bars (no yielding in test)

9.2 Strength of slab concrete, floor test

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 24.11.2006 Upper flange of slab 7 (3 pc.) and slab 8 (3 pc.), vertically

Mean strength [MPa] 74,7 (+7 d)1) drilled, tested as drilled2)

St.deviation [MPa] 4,10 density = 2416 kg/m3

9.3 Strength of slab concrete, reference tests

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 27.11.2006 Upper flange of slab 9,

Mean strength [MPa] 79,7 (+3 d)1) vertically drilled, tested as

St.deviation [MPa] 3,96 drilled2), density =2416 kg/m3

9.4 Strength of grout in longitudinal joints of slab units

#

a

a

a

a mm

Date of test

Note

6 150 17.11.2006 Kept in laboratory in the same

Mean strength [MPa] 25,0 (+0 d)1) conditions as the floor specimen

St.deviation [MPa] 0,72 density = 2183 kg/m3

9.5 Strength of concrete inside the A-beam

#

Cores h

d

h mm

d mm

Date of test

Note

6 50 50 24.11.2006 Vertically drilled through the

Mean strength [MPa] 45,6 (+7 d)1) holes of the top flange, tested

St.deviation [MPa] 5,24 as drilled2) density=2260 kg/m3 1) Date of material test minus date of structural test (floor test or reference test)

2) After drilling, kept in a closed plastic bag until compression

Page 657: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

657

10 Measured displacements

In the following figures, VP stands for the shear force of one slab end due to imposed actuator loads, calculated assuming simply supported slabs.

10.1 Deflections

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25

Deflection [mm]

Vp

[kN

]

11

12131415

Fig. 31. Deflection on line I along Western end beam.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

1617

181920

Fig. 32. Deflection on line II in the middle of slabs 1–4.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

2122

2324

25

Fig. 33. Deflection on line III close to the line load, slabs 1–4.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

2627

2829

30

Fig. 34. Deflection on line IV next to the middle beam, slabs 1–4.

Page 658: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

658

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

31

3233

34

35

Fig. 35. Deflection on line V along the middle beam.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

3637

3839

40

Fig. 36. Deflection on line VI next to the middle beam, slabs 5–8.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

414243

4445

Fig. 37. Deflection on line VII next to the line loads, slabs 5–8.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25 30 35

Deflection [mm]

Vp

[kN

]

4647484950

Fig. 38. Deflection on line VIII in the middle of slabs 5–8. Transducer 46 gave erroneous results.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20

Deflection [mm]

Vp

[kN

]

5152535455

Fig. 39. Deflection on line IX along Eastern end beam, slabs 5–8.

0

20

40

60

80

100

120

140

160

180

0 5 10 15 20 25

Deflection [mm]

Vp

[kN

]

13 end33 middle53 end

Fig. 40. Net deflection of midpoint of middle beam (33) and those of end beams (13, 53).

Page 659: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

659

10.2 Crack width

0

20

40

60

80

100

120

140

160

180

0,0 0,5 1,0 1,5 2,0 2,5 3,0

Differential displacement [mm]

Vp

[kN

] 56

7

89

10

Fig. 41. Differential displacement parallel to the slab between the middle beam and the slabs (≈ crack width).

10.3 Average strain (actually differential displacement)

0

20

40

60

80

100

120

140

160

180

-2,0 -1,5 -1,0 -0,5 0,0

Differential displacement [mm]

Vp

[kN

] 64

6566 beam

67 beam68

69

Fig. 42. Differential displacement at top surface of floor measured by transducers 64–69.

0

20

40

60

80

100

120

140

160

180

0,0 0,5 1,0 1,5 2,0 2,5

Differential displacement [mm]

Vp

[kN

] 747576 beam77 beam7879

Fig. 43. Differential displacement at soffit of floor measured by transducers 74–79.

The differential displacement divided by the mutual distance of the two fixing points represents the average strain between those points. Assuming linearly changing strain in vertical direction, the average strain at any depth between the measured top and bottom values can be calculated from the measured results. The average strain at the top and bottom fibre of the slabs and the middle beam obtained in this way are shown in Figs 45–46.

Assuming parabolic curvature due to the uniformly distributed load on the beam, and having the span of the beam equal to 4,8 m, the maximum strain within each of the slabs 2, 3, 6 and 7 is 9% higher than the average strain measured between the edges of the slab. In this way, the maximum strain is obtained from the average strains by multiplying the latter by 1,09.

Page 660: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

660

0

20

40

60

80

100

120

140

160

180

-0,0015 -0,0010 -0,0005 0,0000

Average strain

Vp

[kN

] Slab 2

Slab 3

66 beam

67 beam

Slab 6

Slab 7

Fig. 44. Top fibre of floor. Average strain calculated from the differential displacements shown in Figs 41–42.

0

20

40

60

80

100

120

140

160

180

0,0000 0,0005 0,0010 0,0015 0,0020

Average strain

Vp [k

N] Slab 2

Slab 3

76 beam

77 beam

Slab 6

Slab 7

Fig. 45. Bottom fibre of floor. Average strain calculated from the differential displacements shown in Figs 41–42.

The variation of the average strain with the depth is illustrated in Figs 47 and 48 at the evaluated service load (Vp = 57 kN) and failure load, respectively. The mean of the average strain both for the slabs and for the beam is shown in Figs 49 and 50 at two load levels.

-50

0

50

100

150

200

250

300

350

-400-2000200400600

Strain [10-6]

De

pth

[m

m]

64-74 slab 2

65-75 slab 3

66-76 beam

67-77 beam

68-78 slab 6

69-79 slab 7

Fig. 46. Average strain of slabs 2, 3, 6 and 7 as well as that of the middle beam, all in beam’s direction, at estimated service load (Vp = 57 kN).

-50

0

50

100

150

200

250

300

350

-2000-1000010002000

Strain [10-6]

De

pth

[m

m]

64-74 slab 2

65-75 slab 3

66-76 beam

67-77 beam

68-78 slab 6

69-79 slab 7

Fig. 47. Average strain of slabs 2, 3, 6 and 7 as well as that of the middle beam, all in beam’s direction, before failure at Vp = 161 kN.

Page 661: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

661

-50

0

50

100

150

200

250

300

350

-400-2000200400600

Strain [10-6]

De

pth

[m

m]

Slabs

Beam

Fig. 48. Mean of average strains measured for slabs 2, 3, 6 and 7 as well as mean of average strains measured for the middle beam at estimated service load (Vp = 57 kN).

-50

0

50

100

150

200

250

300

350

-2000-1000010002000

Strain [10-6]

De

pth

[m

m]

Slabs

Beam

Fig. 49. Mean of average strains measured for slabs 2, 3, 6 and 7 as well as mean of average strains measured for the middle beam before failure at Vp = 161 kN.

Both at service load and at failure, the strains in the top of the slabs were essentially smaller than those in the beam. This can be explained by the low transverse shear stiffness of the slabs. The scatter of the slab strains on the top was small. At service load, the strains in soffit of the slabs were on average of the same order as those in the beam at the same level. The friction force between the soffit of the slabs and the bottom flange of the beam was strong enough to make the strains compatible. This can clearly be seen in Fig. 49. At failure load, the strain in the soffit of the slabs was greater than that in the beam. This may be explained by the weak interaction between the beam and the slabs and longitudinal cracking of the slabs, the first signs of which were observed already before loading and at service load, see Figs 29 and 35.

10.4 Shear displacement

0

20

40

60

80

100

120

140

160

180

0,0 0,5 1,0 1,5 2,0 2,5

Differential displacement [mm]

Vp

[kN

]

56 slab 157 slab 158 slab 459 slab 460 slab 5

61 slab 562 slab 863 slab 8

Fig. 50. Differential displacement between edge of slab and middle beam. A positive value means that the slab is moving towards the end of the beam. At VP = 140 kN the end of slab 8 broke into pieces.

0

20

40

60

80

100

120

140

160

180

0,0 0,5 1,0 1,5 2,0 2,5

Shear displacement [mm]

Vp

[kN

] 56-57 slab 158-59 slab 460-61 slab 562-63 slab 8

Fig. 51. Transverse shear displacement of slab end calculated from displacements shown in Fig. 51.

Page 662: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

662

11 Reference tests

5050

1200P

L

GypsumWood fibre plate

Steel plate

50

1 (2)

3 (4) 5 (6)

600

1

2

3

4

5

6

P

50

50

R R

R R

600

S

S

300 300P

S S

Fig. 52. Layout of reference test. For L see Table 2.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30

Time [min]

Pa

[kN

]

Fig. 53. Test R1. Actuator force – time relationship.

0

50

100

150

200

250

300

350

0 5 10 15 20 25 30

Time [min]

Pa

[kN

]

Fig. 54. Test R2. Actuator force – time relationship.

Page 663: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

663

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12 14 16

Deflection [mm]

Pa

[kN

]123456

Fig. 55. Test R1. Displacements measured by transducers 1–6.

0

50

100

150

200

250

300

350

0 2 4 6 8 10 12

Deflection [mm]

Pa

[kN

]

12

3456

Fig. 56. Test R2. Displacements measured by transducers 1–6.

Table 2. Reference tests. Span of slab, shear force Vg at support due to the self weight of the slab, actuator force Pa at failure, weight of loading equipment Peq, total shear force Vobs at failure and total shear force vobs per unit width.

Test Date Span mm

Vg kN

Pa kN

Peq kN

Vobs kN

vobs kN/m

Note

R1 24.11.2006 7899 18,2 303,6 0,66 278,2 231,8 Web shear failure R2 24.11.2006 6800 15,4 329,5 0,66 289,7 241,4 Flexural shear failure Mean 283,9 236,6

12 Comparison: floor test vs. reference tests

The observed shear resistance (support reaction) of the hollow core slab in the floor test was equal to 183,3 kN per one slab unit or 152,8 kN/m. This is 65% of the mean of the shear resistances observed in the reference tests.

13 Discussion

1. The net deflection of the middle beam due to the imposed actuator loads only (deflection minus settlement of supports) was 20,9 mm or L/230, i.e. rather small. It was 2,1–5,4 mm greater than that of the end beams. Hence, the torsional stresses due to the different deflection of the middle beam and end beams had a negligible effect on the failure of the slabs.

2. The shear resistance measured in the reference tests was of the same order as the mean of the observed values for similar slabs given in Pajari, M. Resistance of prestressed hollow core slab against web shear failure. VTT Research Notes 2292, Espoo 2005.

3. The edge slabs slided 0,4 … 0,5 mm along the beam before failure. This reduced the negative effects of the transverse actions in the slab and had a positive effect on the shear resistance.

4. The transverse shear deformation of the edge slabs was considerable which can be seen in Figs 51–52.

5. The failure mode was web shear failure of edge slabs. The A-beam seemed to recover completely after the failure.

Page 664: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

664

APPENDIX A: A-BEAM

Fig. 1. Plan and section B-B.

Page 665: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

A665

Fig. 2. Sections A-A and C-C and list of steel parts.

Page 666: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B666

APPENDIX B: PHOTOGRAPHS

Fig. 1. A-beam.

Fig. 2. A-beam. Suspension bars temporarily stored on the top of the beam.

Fig. 3. Straight tie bar and bent suspension bar in their final position.

Fig. 4. Detail of the previous figure.

Fig. 5. Hollow core slabs temporarily supported on end beam.

Fig. 6. Middle beam before grouting of joints.

Page 667: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B667

Fig. 7. End of floor before grouting.

Fig. 8. Test floor before grouting. Note the wedges in the joints to facilitate the demolishing of the floor after the test. To eliminate the contact between the floor and the loading frame, the outermost webs of the slabs were made thinner at the legs of the frame.

Fig. 9. Measuring devices at the end of the middle beam.

Fig. 10. Measuring devices at the end of the middle beam.

Fig. 11. View on the loading arrangements.

Fig. 12. Loading on outermost slabs.

Page 668: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B668

Fig. 13. Device for measuring strain parallel to the beams.

Fig. 14. Device for measuring crack width between slab end and middle beam.

Fig. 15. Arrangements at end beam.

Fig. 16. A general view on test arrangements.

Fig. 17. Gap between soffit of slab 1 and bottom flange of middle beam.

Fig. 18. Good contact between soffit of slab 4 and bottom flange of middle beam.

Page 669: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B669

Fig. 19. Good contact between soffit of slab 5 and bottom flange of middle beam.

Fig. 20. Good contact between soffit of slab 8 and bottom flange of middle beam.

Fig. 21. Service load (Pa2 = 70 kN). Cracks below soffit of slabs 2 and 3.

Fig. 22. Service load (Pa2 = 70 kN). Cracks below soffit of slabs 6 and 7.

Fig. 23. Pa2 = 155 kN. Wide cracks in slab 8.

Fig. 24. Cracks in slab 1 after failure.

Page 670: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B670

Fig. 25. Cracks in slab 5 after failure.

Fig. 26. Cracks in slab 8 after failure.

Fig. 27. Cracks in slab 8 after failure.

Fig. 28. Cracks in Western tie beam after failure. Slabs 1 and 2.

Fig. 29. Cracks in Western tie beam after failure. Slabs 2 and 3.

Fig. 30. Cracks in Western tie beam after failure. Slabs 3 and 4. The red colour and letter A refer to an initial crack.

Page 671: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B671

Fig. 31. Cracks in Eastern tie beam after failure. Slabs 5 and 6. The red colour and letter A refer to an initial crack.

Fig. 32. Cracks in eastern tie beam after failure. Slabs 5, 6 and 7. The red colour and letter A refer to an initial crack.

Fig. 33. Cracks in Eastern tie beam after failure. Slabs 6, 7 and 8. The red colour and letter A refer to an initial crack.

Fig. 34. Cracks in Eastern tie beam after failure. Slabs 7 and 8. The red colour and letter A refer to an initial crack.

Fig. 35. Cracks in slab 4 after failure. The red colour and letter A refer to an initial crack.

Fig. 36. Cracks in slab 8 after failure.

Page 672: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B672

Fig. 37. Cracks in slab 1 after failure. The red colour and letter A refer to an initial crack.

Fig. 38. Cracks in slab 5 after failure. The red colour and letter A refer to an initial crack.

Fig. 39. Failed ends of slabs 7 and 8.

Fig. 40. Failed ends of slabs 7 and 8.

Fig. 41. Longitudinal cracking along joint between slabs 6 and 7.

Fig. 42. End of slab 8 after removal of the top flange.

Page 673: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B673

Fig. 43. A-beam after failure. The reinforcing bars have been cut after the test. Note the cement paste which has partly filled the gap between the soffit of slab 1 and the ledge of the beam.

Fig. 44. A-beam after failure. Note the cement paste which has partly filled the gap between the soffit of slab 1 and the ledge of the beam.

Fig. 45. Arrangements in reference tests.

Fig. 46. Reference test R1. Northern side of slab after failure.

Fig. 47. Reference test R1. Southern side of slab after failure.

Fig. 48. Reference test R2. Northern side of slab after failure.

Page 674: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT.CR.A-beam.320.2006

B674

Fig. 49. Reference test R2. Southern side of slab after failure.

Page 675: Matti Pajari Prestressed hollow core slabs supported on beams ...

VTT CREATES BUSINESS FROM TECHNOLOGY Technology and market foresight • Strategic research • Product and service development • IPR and licensing • Assessments, testing, inspection, certification • Technology and innovation management • Technology partnership

• • • VTT WO

RKIN

G PA

PERS 148 PR

ESTRESSEd

HO

LLOW

CO

RE SLA

BS SU

PPOR

TEd O

N B

EAM

S

ISBN 978-951-38-7495-7 (URL: http://www.vtt.fi/publications/index.jsp)ISSN 1459-7683 (URL: http://www.vtt.fi/publications/index.jsp)

Arrangements and results of 20 full-scale load tests on floors, each made of eight to twelve prestressed hollow core slabs and three beams, are presented. The tests have been carried out by VTT Technical Research Centre of Finland and Tampere University of Technology.