matthew c oung
Layout compatto ed efficiente riduce l'accesso alla luce naturale e viste. Il piano inflessibile unificato non può facilmente adattarsi a una futura espansione o aprire per l'ambiente.
Waste heat from process cooling (e.g. office’s computer center) is going into the return of the district cooling system. During the heating season this return is used to feed a central absorption heat pump (low temperatue level). The seasonal storage is used to lift the energy potential on the hot water supply temperature level (80ºC).
The district energy systems allow for using several renewable sources to cover the heating demand. Process or waste heat by ships is available all year. The winter period is characterized by low temperatures and low solar irradiation for about 3 to 4 months. Therefore the heating demand varies over the season significantly, Adding a seasonal storage to the energy supply system provides the potential for optimizing the ratio of renewable used, Even the efficiency of the combined heat and power production facility is optimized by providing a heat sink in summer.
NATURAL VENTILATION MODE
ACTIVE SLAB COOLING
Vertical Duct
Ground duct to Preconditions Air
SUMMER
-LANDFILL-
Central Air Handling Unit
Displacement System
Natural Ventilation Natural Ventilation
Airflow
ACTIVE SLAB COOLING
Airflow
ATRIUM
Radiant Active Tubing in Concrete
Connected to Sea Water Cooling(directly without chiller -18°C)
(Balcony)
Shading
0° 45°
BIOGAS
llewthgil
ylppusthgilyad
ytivacedacaflanretxenignitcudriatsuahxe
roolfdesiar
foordetalusnihgih
noitcetorpralosnoitalitnevlarutan
gnilooc/gnitaehevitaler
dniw
thgilyad
Ruotando le gallerie di 20 gradi per un'ottimale orientamento solare consente auspicabile Northern Light per illuminare naturalmente gli spazi espositivi.
Water conservation measures to minimize consumption:- Grey water reuse (on the spot, for garden vegetation)- Irrigation-free landscaping and green roofs- Avoidance of water use for cooling tower through selection of geothermal system- Waterless or low-flow sanitary fixtures- Snow, melted by heated gutter system, and rain water for outdoor water features- Grey/ snow water for remaining irrigation purposes
Migliorare esperienza del visitatore, tre tipi piccola galleria fornire una varietà di spazi intimi di visualizzazione che completano la collezione permanente del museo di opere d'arte piccole e medie dimensioni.
The use of a natural-gas fired microturbinecogeneration system will generateelectricity and heating for the building, with a 52% reduction over a typical Helsinki building performance. The microturbine could also be configured to run on bio-gas to transition from fossil fuels to renewable energy.
The structure is made with 60% fly ash cement replacement concerete bubble deck and 100% recycled reinforcing steel. LED lighting fixtures and occupancy sensors used throughout the building, balanced with daylight, reduces the use of energy and light pollution.
Layout compatto ed efficiente riduce l'accesso alla luce naturale e viste. Il piano inflessibile unificato non può facilmente adattarsi a una futura espansione o aprire per l'ambiente.
On the west facade, a double skin will provide a thermal buffer to help retain heat within the building. The facade also extends into the basement to help bring daylight into the spaces below.
Organizzazione diffusa mantiene la compattezza e l'efficienza, massimizzando luce naturale e viste. Flessibilità intrinseca del piano si adatta facilmente a una futura espansione, mentre l'apertura si collega con il museo esistente e sito archeologico.
To best ventilate the structure, the facade will be closed in the winter and be opened in the summer to bring fresh air into the space. The benefit of extending the facade below grade, is to bring in fresh air at a low level. Heat is radiated through a raised floor displacement ventilation system. Perimeter throughs within the raised floor will conceal linear hydronic radiators to provide perimeter heating.
Rain Collection
Macro Airflow
Cross Ventilation
Diffused Daylight
WaterRecycling
Snow Collection
Exhaust
Displacement Ventilation
Ventilation Heat Recovery
Black Water
Integrated Solar Panelled Facade
Natural-gas Fired Microturbine
Cogeneration System
LED Lighting Fixtures
100% Recycled Reinforcing Steel
60% Fly Ash Cement Bubble Concrete
DeckWinter
WaterRecycling
Organizzazione ConcentratoDaylighting and Solar Heating Organizzazione Diffuse
VentilationRotazione SolareWater Filtration
Gallerie VarieMaterials and Embedded Energy
Migliorare esperienza del visitatore, tre tipi piccola galleria fornire una varietà di spazi intimi di visualizzazione che completano la collezione permanente del museo di opere d'arte piccole e medie dimensioni.
Waste heat from process cooling (e.g. office’s computer center) is going into the return of the district cooling system. During the heating season this return is used to feed a central absorption heat pump (low temperatue level). The seasonal storage is used to lift the energy potential on the hot water supply temperature level (80ºC).
Gallerie VarieSynergies between District Cooling and Heating Systems
HS
I J
R S
Fifth LevelPublic
Event
Commercial
Collections
Education
Staff
Operations
Service
Fourth Level
Third Level
Second Level
Ground Level
Basement Level
Not Accounted For
Staff
Education
Education
Education
Education
Education
Education
Collections
Collections
Collections
Collections
Collections
Collections
Commercial
Commercial
Commercial
Event
Service
Service
Operations
EducationEvent
Public
Public
Public
Public
Public
Fifth Level
Fourth Level
Third Level
Second Level
Ground Level
Basement Level
10,000 M2 10,000 M2
HCL Room Program
HCL Room Program/ Level
HELSINKI CENTRAL LIBRARY - Platform for Architecture + Research
Role: Project Architect
Type: Civic, LibraryClient: City of Helsinki, Helsinki, FinlandStatus: 2012-2013, Competition in ProcedureArea: 14,000 m2Engineer: ARUPEnvironmental: ARUP, Russell Fortmeyer, Senior ConsultantVisualizer: LabtopArachitect: PAR
AWARDSAmerican Institute of Architects, New York, 2013 Merit AwardAmerican Institute of Architects, National, Emerging Professsionals Award
CONFERENCES
Association of Collegiate Schools of Architecture (ACSA) 101 Conference, San Francisco, US, March 2013
Facades + Innovation Conference, Extreme Ocularity, Chicago, US, October 2012
EXHIBITIONS
American Institute of Architects, New York, Awards ExhibitionCenter for Architecture, New York, US, April 2013
The Southern California Institute of Architecture [SCI-Arc] 40th Anniversary Exhibition, Los Angeles, US, April 2013
American Institute of Architects, National Awards ExhibitionAmerican Center for Architecture, DC, US, March - April 2013
Association of Collegiate Schools of Architecture (ACSA) 101 Conference New Constellations Ecologies Exhibition, San Francisco, US, March 2013
Heart of the Metropolis Exhibition, Jätkäsaari Bunker, Helsinki, FI, October 2012
© LABTOP
© LABTOP
© LABTOP
© LABTOP
© LABTOP
KEELUNG HARBOR TERMINAL - Platform for Architecture + Research
Role: Project Architect
Type: Transit, OfficeClient: Taiwan International Ports Corporation, Keelung, TaiwanStatus: Two Stage Prequalified Competition 2012, FinalistArea: 120,000 m2Budget: 211M USDDesign Architect: PAR, SESExectutive Architect: Ricky Liu AssociatesEngineering: Buro Happold, EnvisionsTransportation: Moffatt & Nichol, LandDesign, Mega TransImages: Labtop, PAR
AWARDS
International Prequalified, Two-stage CompetitionHonorable Mention, September 2012
EXHIBITIONS
The Southern California Institute Of Architecture [sci-arc] 40th Anniversary Exhibition, Los Angeles, US, April 2013
D3 Unbuilt Visions Awards ExhibitionUniversity Of Louisiana, US, March - April 2013
Keelung Harbor Tower ExhibitionYangming Marine Museums, Taipei, TW, October 2012
Keelung Harbor Tower ExhibitionKeelung Evergreen Hotel, Keelung, TW, September 2012
© LABTOP
© LABTOP
© LABTOP
© LABTOP
© LABTOP
© LABTOP
© LABTOP
PIRAEUS ANTIQUITIES MUSEUM - Platform for Architecture + Research
Role: Project Architect
Type: Cultural, MuseumClient: Piraeus Port Authority & Ministry Of CultureLocation: Piraeus, Athens, GreeceStatus: 2012 CompetitionArea: 14,000 M2Architect: ParEngineer: ArupEnvironmental: Arup, Russell Fortmeyer, Senior Consultant
Platform for Architecture + ResearchPress Releases + Web Development
Role: Digital Media Marketing + Web Development
UrbdeZinePress Releases + Web Development
Role: News Contributor
FreelanceProduct Renderings + Formal Studies
Role: 3d Models + Visualizations