Master HP
Highlights
Master HP
•InputstagewithIGBT technology
•GalvanicSeparation
•Highoverload capacity
•LCDDisplay
6
INDUSTRIAL PROCESSES
E-BUSINESS (Servers Farms, ISP/ASP/POP)
ELECTRO-MEDICAL DEVICES
LOCAL AREANETWORKS(LAN)
SERVERS DATA CENTRES
INDUSTRIAL PLCS
EMERGENCY DEVICES (Lights/Alarms)
TELECOM-MUNICATIONS DEVICES
100-500 kVAThree-phase/Three-phase
MasterMPSrangehasbeenenhancedwiththeHPversioninsizesfrom100to500kVAThankstotheon-line,doubleconversiontechnologyachievedentirelywithIGBTandDSP(DigitalSignalProcessor),theMasterHPseriesensuresmaximumprotectionandpowerqualityforanytypeofdataprocessingorindustrialload,particularlyfor“missioncritical”applications,andclassifiedasVFISS11.(VoltageandFrequencyIndependent)inaccordancewithIECEN62040-3.ThisserieshasbeendesignedusinganewconfigurationthatincludesanIGBTsinewaveinputrectifierratherthanthemoreconventionalthyristors.
Zero impact sourceTheHPversionoffersthebenefitssummarisedintheZeroImpactSourceformula,thankstotheIGBTrectifier,solvesallintegrationproblemsinsystemswherethepowersupplyhasalimitedinstalledpower,wheretheUPSisalsopoweredbyagenerator,orwheretherearecompatibilityproblemswithloadsthatgenerateharmoniccurrents,;asamatteroffact,MasterHPhaszeroimpactonthepowersource,eithernetworkorgenerator:•lessthan3%inputcurrentdistortion
•Inputpowerfactor0.99•powerwalk-infunctionthatensuresa
progressivestart-upoftherectifier•start-updelayfunction,torestartthe
rectifierswhenmainspowerisrestoredifthereareseveralUPSsinthesystem.
Inaddition,MASTERHPplaysafilterandpowerfactorcorrectionroleinthepowernetworkupstreamoftheUPS,sinceiteliminatesharmoniccomponentsandthereactivepower,generatedbythepoweredutilities.
Battery care system: maximum battery careMasterHPfeaturesthesameBatteryCareSystemastheMasterseries.TheconventionalMPStakescareofbatteryoperatingstatus,inordertomaintainserviceconditionsforaslongaspossible.
FlexibilityTheconfigurationwiththeoutputtransformer,afeatureofboththeMasterHPandconventionalseries,ischaracterisedbythegalvanicisolationoftheloadandthebatteryforgreaterversatilityinsystemconfigurations.Asamatteroffactitallowsfortwonetworkinputs(mainandemergency)
separate,andcomingfromtwodifferentpowersources;thisisparticularlysuitedtoparallelsystemsinordertoensuretheselectivitybetweenthetwosources,thusimprovingthereliabilityoftheentireinstallation.
Options•Inputisolationtransformer•Synchronisationdevice(seeUGS
MasterMPS)•Hotconnectiondevice(seePSJ
MasterMPS)•Interfaceforgenerator•ClosedLoopparallelkitoption(Closed
loop:tobeorderedwiththeUPS)•Emptybatterycabinetsorforruntimes
Main features•Highoutput•Compactsize:only0.85m2afor
250kVAUPS•Lightweight•Doubleloadprotection,bothelectronic
andgalvanic,forthebattery.TheentireHPMasterrangeissuitedforuseinthebroadestspectrumofapplications;thankstotheflexibilityofconfiguration,accessoriesandoptionsavailable,itissuitedforpoweringcapacitiveloadssuchasbladeservers,etc.
MHT 100MHT 120
MHT 300MHT 400
MHT 160 - MHT 200MHT 250
800 850
1900
1000 850
1900
1500 1000
1900
2100 1000
1900
MHT 500
dimensions (mm)
Batte
ry
Maintenance Bypass Cabinet
Load
Bypass mains
Mains
UPS1 UPS2 UPS3... UPS8
Mains Mains
Batte
ry
Batte
ry
Batte
ry
Load
Bypass mains
Mains
UPS1 UPS2 UPS3... UPS8 CommonBY PASS
Mains Mains
Batte
ry
Batte
ry
UPS1A UPS2A
UGSSinchroniser
Static TransferSWITCH
Bypass 1System A
Load 1
Batte
ry
Mains
System B Bypass 2
Mains Mains Mains
Batte
ry
Batte
ry
Batte
ry
UPS1B UPS2B
Load 2
Load 4
Load 3
Static TransferSWITCH
UPS1A UPS2A
PSJ
SWITCH
Bypass 1System A
Load 1
Batte
ry
Mains
System B Bypass 2
Mains Mains Mains
Batte
ry
Batte
ry
Batte
ry
UPS1B UPS2B
Load 2
Parallel architecture that ensures the redundancy of the power source. +Flexibility and modularity
Solution that ensures redundancy until the distribution of the powersupply to the loads + Downstream fault discrimination
Parallel configuration of up to 8 units with distributed bypass
Dynamic dual bus configuration
Parallel configuration of up to 8 units with common bypass
Parallel architecture that ensures the redundancy of the power source, with autonomous bypass management. + Selectivity of downstream faults in bypass mode
Solution that ensures the redundancy of the power supply evenduring maintenance + High availability and redundancy
Dual bus system configuration
Parallel SystemPowersupplyreliabilityandavailabilityforcriticalapplications
areguaranteedbytheparalleldistributedorcentralisedparallelupto8units,perredundant(N+1)or
powerparallelandbyallthedifferentconfigurationsavailableintheMasterMPSrange.
MODELS MHT 100 MHT 120 MHT 160 MHT 200 MHT 250 MHT 300 MHT 400 MHT 500
POWER 100 120 160 200 250 300 400 500
INPUT
Nominal voltage 380 - 400 - 415 Vac Three-phase
Frequency 45 ÷ 65 Hz
Power factor > 0.99
Harmonic current distortion <3% THDi
Soft start 0 ÷ 100% in 30’’ (selectable)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Standard equipment provided standard
Back Feed protection; separable bypass line
BATTERIES
Type open lead acid and VRLA AGM / GEL; NiCd.
Ripple current Zero
Charge voltage compensation -0.5 Vx°C
OUTPUT
Nominal power (kVA) 100 120 160 200 250 300 400 500
Active power (kW) 90 108 144 180 225 270 360 450
Number of phases 3 + N
Nominal voltage 380 - 400 - 415 Vac Three-phase + N
Static stability ± 1%
Dynamic stability ± 5% in 10 ms
Voltage distortion < 1% with linear load / < 3% with non-linear load
Crest factor (lpeack/lrms) 3:1
Frequency stability on battery 0.05%
Frequency 50 or 60 Hz (selectable)
Overload 110% for 60’; 125% for 10’; 150% for 1’
INFO FOR INSTALLATION
Weight (kg) 656 700 800 910 1000 1400 1700 2100
Dimensions (hwd) (mm) 1900 x 800 x 850 1900 x 1000 x 850 1900 x 1500 x 1000 1900 x 2100 x 1000
Remote signals voltage-free contacts (configurabile)
Remote controls ESD and bypass (configurabile)
Communication Double RS232 + remote contacts + 2 slots for communications interface
Ambient temperature 0°C / +40°C
Relative humidity < 95% non-condensing
Colour Dark grey RAL 7016
Noise level (1 m) 63 ÷ 68 dBA 70 ÷ 72 dBA 70 dBA
Protection level IP20 (others upon request)
Smart Active Output up to 98,5%
Regulations Safety: EN 62040-1-1 (directive 2006/95/EC); EMC: EN 62040-2 (directive 2004/108/EC)
Classification according to IEC 62040-3
(Voltage Frequency Independent) VFI - SS - 111
RIE
LLO
ELE
TT
RON
ICA
RIE
LLO
ELE
TT
RON
ICA
RIELLO ELETTRONICA
GE
NE
RA
LC
ATA
LO
GU
E2
01
1-
12
CATG
ENX0
111R
UGB
- In
the
inte
rest
of p
rodu
ct im
prov
emen
t Rie
llo U
PS re
serv
es th
e rig
ht to
cha
nge
spec
ifica
tions
with
out n
otic
e.