March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2...

7
Corporate Office 17522 Bothell Way Northeast Bothell, Washington 98011 Phone 425.415.0551 Fax 425.415.0311 www.riley-group.com March 17, 2020 Mr. James Tosti McCormick Communities 805 Kirkland Avenue, Suite 200 Kirkland, Washington 98033 Subject: Large-Scale Pilot Infiltration Test McCormick Woods Parcel A McCormick Woods Drive SW & St. Andrews Drive SW Port Orchard, Washington RGI Project No. 2019-088B Dear Mr. Tosti: As requested, The Riley Group, Inc. (RGI) is pleased to provide the results of the Large-Scale Pilot Infiltration Test completed at the request of the City at the proposed McCormick Woods Parcel A residential development Site, located in Port Orchard, Washington (Figure 1). RGI previously completed infiltration assessments at the Site which is summarized in our reports: “Infiltration Assessment, McCormick Woods Parcel A, McCormick Woods Drive SW & St. Andrews Drive SW, Port Orchard, Washington, dated June 26, 2019.” “Supplemental Infiltration Assessment, McCormick Woods Parcel A, McCormick Woods Drive SW & St. Andrews SW, Port Orchard, Washington, dated December 3, 2019” The results of our Large Scale Pilot Infiltration Test (PIT) completed within the footprint of the proposed Parcel A Stormwater Pond is summarized below. Project Description The project site is located on the northeast corner of McCormick Woods Drive Southwest & St. Andrews Drive Southwest in Port Orchard, Washington. The approximate location of the site is shown on Figure 1. RGI understands the site is to be developed with a 55 lot residential development. An access road will wind through the site with entrance/exit areas on McCormick Woods Drive Southwest and St. Andrews Drive Southwest. A stormwater pond will be located in the northern portion of the site. Subsurface Conditions RGI oversaw the completion of a Large Scale Pilot Infiltration test (IT-201) within the footprint of the proposed Parcel A stormwater pond, as shown on Figure 2. Subsurface conditions in infiltration test IT-201 included three feet of reddish brown silty sand with gravel underlain by gray sand with some silt. Subsurface conditions were similar in test pit TP-201 completed south of the proposed pond location.

Transcript of March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2...

Page 1: March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2 MW-1 MW-2 IT-101 IT-102 TP-101 TP-102 TP-103 TP-201 IT-201 N Geotechnical Exploration

Corporate Office 17522 Bothell Way Northeast Bothell, Washington 98011 Phone 425.415.0551 ♦ Fax 425.415.0311

www.riley-group.com

March 17, 2020

Mr. James Tosti McCormick Communities 805 Kirkland Avenue, Suite 200 Kirkland, Washington 98033

Subject: Large-Scale Pilot Infiltration Test

McCormick Woods Parcel A McCormick Woods Drive SW & St. Andrews Drive SW

Port Orchard, Washington RGI Project No. 2019-088B

Dear Mr. Tosti:

As requested, The Riley Group, Inc. (RGI) is pleased to provide the results of the Large-Scale Pilot Infiltration Test completed at the request of the City at the proposed McCormick Woods Parcel A residential development Site, located in Port Orchard, Washington (Figure 1). RGI previously completed infiltration assessments at the Site which is summarized in our reports:

“Infiltration Assessment, McCormick Woods Parcel A, McCormick Woods Drive SW & St. Andrews Drive SW, Port Orchard, Washington, dated June 26, 2019.”

“Supplemental Infiltration Assessment, McCormick Woods Parcel A, McCormick Woods Drive SW & St. Andrews SW, Port Orchard, Washington, dated December 3, 2019”

The results of our Large Scale Pilot Infiltration Test (PIT) completed within the footprint of the proposed Parcel A Stormwater Pond is summarized below.

Project Description

The project site is located on the northeast corner of McCormick Woods Drive Southwest & St. Andrews Drive Southwest in Port Orchard, Washington. The approximate location of the site is shown on Figure 1.

RGI understands the site is to be developed with a 55 lot residential development. An access road will wind through the site with entrance/exit areas on McCormick Woods Drive Southwest and St. Andrews Drive Southwest. A stormwater pond will be located in the northern portion of the site.

Subsurface Conditions

RGI oversaw the completion of a Large Scale Pilot Infiltration test (IT-201) within the footprint of the proposed Parcel A stormwater pond, as shown on Figure 2. Subsurface conditions in infiltration test IT-201 included three feet of reddish brown silty sand with gravel underlain by gray sand with some silt. Subsurface conditions were similar in test pit TP-201 completed south of the proposed pond location.

lstone
Static Received Stamp
lstone
Text Box
LU19-PLAT PRELIM-02
Page 2: March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2 MW-1 MW-2 IT-101 IT-102 TP-101 TP-102 TP-103 TP-201 IT-201 N Geotechnical Exploration
Page 3: March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2 MW-1 MW-2 IT-101 IT-102 TP-101 TP-102 TP-103 TP-201 IT-201 N Geotechnical Exploration

USGS, 2014, Bremerton West, WashingtonUSGS, 2017, Burley, Washington

7.5-Minute Quadrangle

Approximate Scale: 1"=1000'

0 500 1000 2000 N

Site Vicinity Map

Figure 1

03/2020

Corporate Office17522 Bothell Way NortheastBothell, Washington 98011Phone: 425.415.0551Fax: 425.415.0311

McCormick Woods Parcel ARGI Project Number:

2019-088BDate Drawn:

Address: McCormick Woods Dr. Southwest & St. Andrews Dr., Port Orchard, Washington 98367

SITE

Page 4: March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2 MW-1 MW-2 IT-101 IT-102 TP-101 TP-102 TP-103 TP-201 IT-201 N Geotechnical Exploration

TP-1

TP-2

TP-3TP-4

TP-5

TP-6

TP-7

TP-8

IT-1

IT-2

MW-1

MW-2

IT-101

IT-102

TP-101TP-102

TP-103

TP-201

IT-201

N

Geotechnical Exploration Plan

Figure 2

Approximate Scale: 1"=200'

0 100 200 400

= Test pit by RGI, 03/12/20= Large-scale infiltration test pit by RGI, 03/12/20= Infiltration test pit by RGI, 10/30/19= Test pit by RGI, 10/30/19= Monitoring well, 10/30/19= Infiltration test pit by RGI, 06/10/19= Test pit by RGI, 04/30/19= Site boundary

03/2020

Corporate Office17522 Bothell Way NortheastBothell, Washington 98011Phone: 425.415.0551Fax: 425.415.0311

McCormick Woods Parcel ARGI Project Number:

2019-088BDate Drawn:

Address: McCormick Woods Dr. Southwest & St. Andrews Dr., Port Orchard, Washington 98367

Page 5: March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2 MW-1 MW-2 IT-101 IT-102 TP-101 TP-102 TP-103 TP-201 IT-201 N Geotechnical Exploration

Project Name: McCormick Woods

Project Number: 2019-088B

Client: Windward

Test Pit No.: TP-201

Date(s) Excavated: 3/12/2020

Excavation Method: Test Pit

Excavator Type: Tracked Excavator

Groundwater Level: 13'

Test Pit Backfill: Cuttings

Logged By ELW

Bucket Size: N/A

Excavating Contractor: Client Provided

Sampling Method(s)

Location McCormick Woods Drive SW and St. Andrews Drive SW, Port Orchard, WA

Surface Conditions: Mixed Brush/Ferns

Total Depth of Excavation: 14 feet bgs

Approximate Surface Elevation 384

Compaction Method Bucket tampU

SC

S S

ymbo

l

TPSL

SM

SP-SM

REMARKS AND OTHER TESTSGra

phic

Log

MATERIAL DESCRIPTION

6" topsoil

Reddish brown silty SAND with trace gravel, loose to medium dense, moist

Becomes tan, medium dense

Gray SAND with some silt and trace gravel, medium dense to dense, moist

Becomes dense

Becomes wet

Becomes water bearing

Test Pit terminated at 14'

Dep

th (

feet

)

0

5

10

15

Sam

ple

Num

ber

Sam

ple

Typ

e

Ele

vatio

n (f

eet)

384

379

374

369

Sheet 1 of 1

The Riley Group, Inc. 17522 Bothell Way NE, Bothell, WA 98011

Page 6: March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2 MW-1 MW-2 IT-101 IT-102 TP-101 TP-102 TP-103 TP-201 IT-201 N Geotechnical Exploration

Project Name: McCormick Woods

Project Number: 2019-088B

Client: Windward

Test Pit No.: IT-201

Date(s) Excavated: 3/12/2020

Excavation Method: Test Pit

Excavator Type: Tracked Excavator

Groundwater Level: Not Encountered

Test Pit Backfill: Cuttings

Logged By ELW

Bucket Size: N/A

Excavating Contractor: Client Provided

Sampling Method(s)

Location McCormick Woods Drive SW and St. Andrews Drive SW, Port Orchard, WA

Surface Conditions: Mixed Brush/Ferns

Total Depth of Excavation: 8 feet bgs

Approximate Surface Elevation 380

Compaction Method Bucket tampU

SC

S S

ymbo

l

TPSL

SM

SP-SM

REMARKS AND OTHER TESTSGra

phic

Log

MATERIAL DESCRIPTION

6" topsoil

Reddish brown silty SAND with trace gravel, loose to medium dense, moist

Becomes medium dense

Gray SAND with some silt, medium dense to dense, moist

Large 10'X10' PIT infiltration test conducted at 8'

Dep

th (

feet

)

0

5

10

15

Sam

ple

Num

ber

Sam

ple

Typ

e

Ele

vatio

n (f

eet)

380

375

370

365

Sheet 1 of 1

The Riley Group, Inc. 17522 Bothell Way NE, Bothell, WA 98011

Page 7: March 17, 2020 Mr. James Tosti McCormick Communities 805 ... · TP-4 TP-5 TP-6 TP-7 TP-8 IT-1 IT-2 MW-1 MW-2 IT-101 IT-102 TP-101 TP-102 TP-103 TP-201 IT-201 N Geotechnical Exploration

Project Name: McCormick Woods

Project Number: 2019-088B

Client: Windward

Key to Logs

US

CS

Sym

bol

REMARKS AND OTHER TESTSGra

phic

Log

MATERIAL DESCRIPTIONDep

th (

feet

)

Sam

ple

Num

ber

Sam

ple

Typ

e

Ele

vatio

n (f

eet)

1 2 3 4 5 6 7 8

COLUMN DESCRIPTIONS

1 Elevation (feet): Elevation (MSL, feet).2 Depth (feet): Depth in feet below the ground surface.3 Sample Type: Type of soil sample collected at the depth interval

shown.4 Sample Number: Sample identification number.

5 USCS Symbol: USCS symbol of the subsurface material.6 Graphic Log: Graphic depiction of the subsurface material

encountered.7 MATERIAL DESCRIPTION: Description of material encountered.

May include consistency, moisture, color, and other descriptivetext.

8 REMARKS AND OTHER TESTS: Comments and observationsregarding drilling or sampling made by driller or field personnel.

FIELD AND LABORATORY TEST ABBREVIATIONS

CHEM: Chemical tests to assess corrosivityCOMP: Compaction testCONS: One-dimensional consolidation testLL: Liquid Limit, percent

PI: Plasticity Index, percentSA: Sieve analysis (percent passing No. 200 Sieve)UC: Unconfined compressive strength test, Qu, in ksfWA: Wash sieve (percent passing No. 200 Sieve)

MATERIAL GRAPHIC SYMBOLS

Silty SAND (SM) Poorly graded SAND with Silt (SP-SM)

Topsoil

TYPICAL SAMPLER GRAPHIC SYMBOLS

Auger sampler

Bulk Sample

3-inch-OD California w/brass rings

CME Sampler

Grab Sample

2.5-inch-OD ModifiedCalifornia w/ brass liners

Pitcher Sample

2-inch-OD unlined splitspoon (SPT)

Shelby Tube (Thin-walled,fixed head)

OTHER GRAPHIC SYMBOLS

Water level (at time of drilling, ATD)

Water level (after waiting)

Minor change in material properties within astratum

Inferred/gradational contact between strata

? Queried contact between strata

GENERAL NOTES

1: Soil classifications are based on the Unified Soil Classification System. Descriptions and stratum lines are interpretive, and actual lithologic changes may begradual. Field descriptions may have been modified to reflect results of lab tests.2: Descriptions on these logs apply only at the specific boring locations and at the time the borings were advanced. They are not warranted to be representativeof subsurface conditions at other locations or times.

Sheet 1 of 1

The Riley Group, Inc. 17522 Bothell Way NE, Bothell, WA 98011